Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LC Duplex Adapter For LC Cutouts

Jul07 Rev C

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

/Mar/2014 Rev A

MT-RJ Optical Fiber System Field Testing

Jan05 Rev A EC

Mar11 Rev B

Jun08 Rev A

Two Circuit Heavy Duty Burner Connector

Jun08 Rev C

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

FEB. 17 Rev. A1

Mar11 Rev C

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

FiberExpress Solutions

Fibrlok II 2529 Universal Optical Fiber Splice

Cat 6 Shielded Patch cords

Special Provision No. 683S28 December 2017

/Oct/2014 Rev B

/Oct/2014 Rev E

Product Specification Qualification Test Report

Cat 6 Unshielded Patch cords

JUL 18 Rev A1

Fiber Optic Patch Cord and Pigtails

APR 17 Rev A

ITU-T L.404. Field mountable single-mode optical fibre connectors

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

HMN-D2 Insert Series

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

ETSI TS V1.2.1 ( )

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

ETSI TS V1.2.1 ( )

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

4120 Fire Alarm Network Reference

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Draft ES V1.1.1 ( )

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

Connections You Can Count On.

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

Fiber Optic Products Catalog

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

USB 3.0 Plug & Receptacle

Fibre (TIA) Field Test Specification

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

Fiber Optic Distribution Cables (6-144 Fibers)

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Qualification Test Report 1/Jul/2005 Rev. A

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Inverted Through Board Surface

EOTec 2C32 Installation Guide

Introducing SlimSeal SSL Connector

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

STANDARD CONFORMANCE

Universal Retention Modules 02 MAR 10 Rev A

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

The Rise of Tier 2 Testing

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Introducing Hermaphroditic Blade and Receptacle Connector

Application Engineering Note. Importance of Jacket Crimping

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

INTERNATIONAL STANDARD

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Figure 1 - Parts of a Fiber Optic Connector

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Applications Engineering Notes

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

NG4access ODF Platform Standard Chassis Installation Manual

Basic Professional Fiber Optic Installation

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Fiber Optic Connector Cleaning Solutions

Noyes OFL 250B Specs Provided by

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Pneumatic Flat Grips. Relevant Materials. Relevant Specimens

FIBER OPTIC CONNECTOR CLEANERS

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Transcription:

Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece housing, fiber optic connectors to determine their conformance to the requirements of the Optical Fiber Cabling Components Standard, TIA/EIA-568-B.3. This report covers the optical, environmental, and mechanical performance of LC multimode, one-piece housing, fiber optic connectors terminated to 2.0 mm jacketed 50/125 :m cable. Cable assemblies were manufactured by Tyco Electronics, Fiber Optics Business Unit. Testing was performed between 31Jan06 and 21Feb06. The test file number for this testing is B066497-006. 1.3. Conclusion LC multimode, one-piece housing, fiber optic connectors, terminated to 2.0 mm jacketed cable (as described in paragraph 1.5), meet the optical, environmental, and mechanical performance requirements of the Optical Fiber Cabling Components Standard, TIA/EIA-568-B.3 when two simplex connectors are fastened together to form a duplex connector. LC connectors terminated to cable with 62.5/125 :m fiber size are assumed to be qualified by similarity to performance of LC connectors terminated to cable with 50/125 :m fiber size. 1.4. Product Description The Tyco Electronics LC fiber optic cable assemblies consist of two simplex, epoxy, LC connectors fastened together to form a duplex connector on one end of 2.0 mm jacketed, OFNP zipcord cable, and dual FC connectors on the other end for attachment to optical measurement equipment. LC fiber optic cable assemblies are used in data communication and telecommunications networks and equipment. 2006 Tyco Electronics Corporation Harrisburg, PA All International Rights Reserved * Trademark 1 of 8 Indicates change LOC B

1.5. Test Specimens Test specimens were manufactured using normal production means. Specimens consisted of two duplex cable assemblies mated to form an LC duplex connector pair, and the following supplies outlined below. Component Test Group Description 1 2 3 Fiber size (microns/microns) 50/125 Cable Type 2.0 mm OFNP Zipcord Cable Assembly PN (See Note (a)) 1918191-5 Connector Type (See Note (b)) Simplex LC Coupling Receptacle PN 1754683-1 Test Specimens Required (See Note (c)) 8 (duplex) 8 (duplex) 8 (duplex) Control Cable Required Yes No No NOTE (a) Cable assembly consists of two simplex LC connectors, PN 1918267-1, terminated to cable PN 6457471-2. (b) Two simplex LC connectors are fastened together with LC duplex clip PN 1754371-1 to form a duplex specimen. (c) Two duplex cable assemblies and one duplex adapter were used to form one mated connector pair (test specimen). 1.6. Qualification Test Sequence Test Groups (a) Test or Examination 1 2 3 Test Sequence (b) Visual and mechanical inspection 1 1 1 Attenuation (insertion loss) 2 2 2 Return loss 3 3 3 Low temperature 4 Temperature life 5 Humidity, steady state 6 Strength of coupling mechanism 4 Cable retention, 0 degrees 5 Cable retention, 90 degrees 6 Flex 7 Twist 8 Impact 4 Durability 5 NOTE (a) See paragraph 1.5. (b) Numbers indicate sequence in which tests are performed. Rev A 2 of 8

2. SUMMARY OF TESTING 2.1. Visual and Mechanical Inspection - All Test Groups All specimens submitted for testing were manufactured by Tyco Electronics, and were inspected and accepted by the Product Assurance Department of the Fiber Optics Business Unit. Specimens are assumed to be compliant with FOCIS dimensions from Tyco Electronics First Article approval, which included verification of product drawings per the dimensions specified in TIA/EIA-604-10A. 2.2. Initial Optical Performance - All Test Groups All attenuation and return loss measurements met the specification requirements. Attenuation and return loss were measured at 850 nm and 1300 nm wavelengths for all test groups. Attenuation (Insertion Loss) and Return Loss - Requirements for New Product (db) Performance Requirements Test Groups (1-3) 850 nm 1300 nm Maximum allowed attenuation for any individual specimen 0.75 0.75 Minimum allowed return loss for any individual specimen 20 20 Attenuation (Insertion Loss) and Return Loss - Actual for New Product (db) Maximum and Median Minimum and Median Test Attenuation Values Return Loss Values Group 850 nm 1300 nm 850 nm 1300 nm 1 2 3 0.23 Max 0.10 Med 0.34 Max 0.18 Med 0.60 Max 0.21 Med 0.16 Max 0.06 Med 0.26 Max 0.12 Med 0.43 Max 0.16 Med 28.7 Min 30.4 Med 26.5 Min 27.3 Med 26.5 Min 28.7 Med 31.3 Min 32.9 Med 30.8 Min 32.3 Med 31.4 Min 36.5 Med Rev A 3 of 8

2.3. Attenuation, Change in Attenuation, Attenuation Increase and Return Loss - All Test Groups Test Group 1 2 3 All attenuation, change in attenuation, attenuation increase and return loss measurements met the specification requirements. All measurements were recorded at 850 nm and 1300 nm for 50/125 :m fiber size. Values shown in the table below represent maximum attenuation, maximum change in attenuation, maximum attenuation increase and minimum return loss. Attenuation, Change in Attenuation, Attenuation Increase and Return Loss Results (db) Condition Low temperature Requirements (850 and 1300 nm) Actual (850 nm) Actual (1300 nm) Before During After Before During After Before During After IL )IL IL,RL,IL8 IL )IL IL,RL,IL8 IL )IL IL,RL,IL8 0.75(IL) Temperature life 0.75 NA 0.22 NA 0.3 0.23 0.07 Humidity, steady state 0.4 0.24 0.14 Strength of coupling mechanism 0.75IL Cable retention, 0 degrees 0.75(IL) Cable retention, 0.75 NA 0.5(IL8) 90 degrees 0.32 0.42 0.40 Cable flexing 0.75(IL) 0.40 Twist 0.47 Impact 0.60 0.75(IL) 0.75 NA Durability 0.61 NA NA 0.22(IL) 28.8 (RL) 0.23(IL) 29.1(RL) 0.17(IL) 29.1(RL) 0.32(IL) 0.42(IL) 0.02(IL8) 0.39(IL) 0.01IL8) 0.41(IL) 0.47(IL) 0.59(IL) 26.6(RL) 0.62(IL) 27.2(RL) 0.16 0.04 0.15 NA 0.16 0.11 0.24 0.31 0.33 0.31 0.36 0.43 0.43 NA NA 0.15(IL) 31.7 (RL) 0.16(IL) 32.1(RL) 0.10(IL) 32.1(RL) 0.23(IL) 31.4(RL) 0.31(IL) 31.2(RL) 0.01(IL8) 0.33(IL) 31.3(RL) 0.01(IL8) 0.31(IL) 31.4(RL) 0.37(IL) 31.3(RL) 0.42(IL) 31.3(RL) 0.45(IL) 32.6(RL) NOTE (IL) - Insertion Loss (Attenuation) ()IL) - Change in Insertion Loss (Attenuation) (IL8) - Insertion Loss (Attenuation) Increase (RL) - Return Loss 2.4. Low Temperature - Test Group 1 There was no evidence of physical damage to the connector or cable and no change in optical performance beyond the specified limit during low temperature exposure. All attenuation and return loss measurements met requirements before and after test. Optical performance was measured at 850 and 1300 nm. 2.5. Temperature Life - Test Group 1 There was no evidence of physical damage to the connector or cable after temperature life. All attenuation and return loss measurements met specified limits before and after test. Optical performance was measured at 850 and 1300 nm. Rev A 4 of 8

2.6. Humidity, Steady State - Test Group 1 There was no evidence of physical damage to the connector or cable and no change in optical performance beyond the specified limits during steady state humidity. All attenuation and return loss measurements met requirements before and after test. Optical performance was measured at 850 and 1300 nm. 2.7. Strength of Coupling Mechanism - Test Group 2 There was no evidence of physical damage to the connector. Attenuation and return loss measurements met the specified limits before and after strength of coupling mechanism test. Optical performance was measured at 850 and 1300 nm. 2.8. Cable Retention, 0 Degrees - Test Group 2 There was no evidence of jacket pullout, or other damage to the connector or cable and no change in optical performance beyond the specified limits after cable retention test. Optical performance was measured at 850 and 1300 nm. 2.9. Cable Retention, 90 Degrees - Test Group 2 There was no evidence of jacket pullout, or other damage to the connector or cable and no change in optical performance beyond the specified limits after side pull test. Optical performance was measured at 850 and 1300 nm. 2.10. Flex - Test Group 2 There was no evidence of physical damage to the connector or cable. Attenuation and return loss measurements met the specified limits before and after flex test. Optical performance was measured at 850 and 1300 nm. 2.11. Twist - Test Group 2 There was no evidence of physical damage to the connector or cable. Attenuation and return loss measurements met the specified limits before and after twist test. Optical performance was measured at 850 and 1300 nm. 2.12. Impact - Test Group 3 There was no evidence of physical damage to the connector or cable. Attenuation and return loss measurements met the specified limits before and after impact test. Optical performance was measured at 850 and 1300 nm. 2.13. Durability - Test Group 3 There was no evidence of physical damage to the connectors or adapter. Attenuation and return loss measurements met the specified limits before and after durability test. Optical performance was measured at 850 and 1300 nm. Rev A 5 of 8

3. TEST METHODS The multimode environmental facility is an automated, FOTP-20 compliant test system with initial specimen installation performed according to FOTP-171 procedures. Following the installation of the specimens, the sequential testing was performed. For mechanical tests, optical measurements were obtained using manually operated FOTP-20 compliant test equipment. Initial specimen installation was performed according to FOTP-171 procedures. Following the installation of the specimens, the sequential testing was performed. 3.1. Visual and Mechanical Inspection Product drawings and inspection plans were used to examine the specimens. They were examined visually and functionally. 3.2. Attenuation (Insertion Loss) All multimode attenuation was measured in accordance with FOTP-171, method D1 processes, except that the launch was part of the specimen under test and was not reference quality. The initial optical power through each launch connector fiber path was measured. The connector assembly was then mated and optical power measured from the receive side cable assembly. Attenuation was calculated by taking the difference between these two measurements. The receive side cable assembly was then connected to the optical test equipment. Optical power was recorded as a reference to calculate change in attenuation during/after subsequent tests. Optical power readings were compensated by changes in a source monitor cable. In cases where a control cable was also used and exceeded limits stated in the specification, the change in the control cable was also factored into the loss. 3.3. Change in Attenuation The initial optical power (dbm) through the specimens was recorded before the test using an optical source and detector. Relative optical power (db) through the fiber was measured during and after each test as applicable. Change in attenuation was calculated by taking the difference between the initial measurement and the during/after measurements and recording the maximum range of all values for a specimen. Optical power readings were compensated by changes in the source monitor cable. In cases where a control cable was also used and exceeded limits stated in the specification, the change in the control cable was also factored into the loss. 3.4. Attenuation Increase Increase in attenuation was calculated by taking the difference between the initial measurement and the measurement after each test. Attenuation increase represents a change in attenuation that results from a decrease in optical power (degraded performance). Optical power readings were compensated by changes in the source monitor cable. 3.5. Return Loss Return loss was measured in accordance with FOTP-107. A single measurement was recorded for return loss. Return loss was measured initially and after each test evaluation. 3.6. Low Temperature Mated specimens were subjected to 0/C for a period of 96 hours (4 days). Optical performance for each specimen was recorded before and after exposure with the specimens in place in the test chamber and at 15-minute intervals throughout the exposure. Final optical performance was recorded after specimens returned to ambient conditions. Rev A 6 of 8

3.7. Temperature Life Mated specimens were subjected to 60/C for a period of 96 hours (4 days). Optical performance for each specimen was recorded before and after exposure with the specimens in place in the test chamber. Final optical performance was recorded after specimens returned to ambient conditions. 3.8. Humidity, Steady State Mated specimens were subjected to 40 ± 2/C at 90 to 95% RH for a period of 96 hours (4 days). Optical performance for each specimen was recorded before and after exposure with the specimens in place in the test chamber and at 15-minute intervals throughout the exposure. Final optical performance was recorded after specimens returned to ambient conditions. 3.9. Strength of Coupling Mechanism A duplex connector was mated to a duplex adapter which was secured to the test fixture. A 33 N [7.4 lbf] tensile load was applied at a rate of approximately 25.4 mm [1 in] per minute to the coupling mechanism by using a nylon string wrapped around the duplex connector clip. The load was sustained for a minimum of 5 seconds. Optical performance was measured before and after test with the load removed. 3.10. Cable Retention, 0 Degrees Duplex specimens were subjected to a sustained load of 50 N [11.24 lbf] for a minimum of 5 seconds. A nylon string wrapped around the duplex connector clip was used to secure the connector. The tensile load was manually applied by wrapping the jacketed cable around a 7.5 cm [3 in] diameter mandrel at a point 25.4 cm [10 in] from the connector. Optical performance was measured before and after test with the load removed. 3.11. Cable Retention, 90 Degrees Duplex specimens were subjected to a sustained load of 19.4 N [4.4 lbf] for a minimum of 5 seconds. An adapter was secured to the test fixture. The load was manually applied at a 90 degree pull angle by wrapping the jacketed cable around a 7.5 cm [3 in] diameter mandrel at a point 25.4 cm [10 in] from the connector. Optical performance was measured before and after test with the load removed. 3.12. Cable Flexing 3.13. Twist Duplex specimens were subjected to 100 cycles of fiber flexing. Specimens were tested at a rate of 25 cycles per minute. A brass block cable clamp was used to apply a tensile load of 0.5 Kg [1.1 lbf] to jacketed cable at a point approximately 25.4 cm [10 in] from the connector. The flex arc was ± 90 degrees from a vertical position. Optical performance was measured before and after test with the load removed. Duplex specimens were subjected to 10 cycles of twist. Specimens were manually tested at a rate of approximately 3 cycles per minute. A 7.5 cm [3 in] diameter mandrel was used to apply a tensile load of 15 N [3.4 lbf] to jacketed cable at a point approximately 25.4 cm [10 in] from the connector. The twist motion for each cycle was ± 2.5 revolutions about the axis of the fiber. Optical performance was measured before and after test with the load removed. Rev A 7 of 8

3.14. Impact An unmated duplex connector assembly, with protective cap over the ferrule, was dropped in random orientations from a height of 1.8 m [70.9 in] onto a concrete slab. The impact exposure was repeated 8 times. Initial optical performance was recorded before the specimen was unmated and exposed to testing. After completion of the 8 impacts, each connector was inspected, cleaned and re-mated before recording final optical measurements. 3.15. Durability The duplex connector on one end of each mated specimen was subjected to 500 cycles of durability. Specimens were manually cycled at a rate not in excess of 300 cycles per hour. The connector and adapter were cleaned as specified every 25 cycles during test. Optical performance was measured before and after test. Specimens were unmated, cleaned, inspected, and re-mated before final optical measurements. Rev A 8 of 8