NUOS RANGE HEAT PUMP WATER HEATERS

Similar documents
Aqua 1 plus Air-water heat pumps for domestic hot water production

High performances NEW ELECTRIC STORAGE WATER HEATERS

Heat Pump Water Heater Commercial Leaflet 2012

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

ISH 2017 HOT WATER I HEATING I RENEWABLE

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

Air to water Heat Pump System

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

AQUAHEAT ADVANCE SPLIT

Air to water Heat Pump System

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

THE HEAT PUMP CHOICE OF PROFESSIONALS

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING

Natural geothermal energy

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

EVI + INVERTER MODELS A Q U A P U R A

2 - The compressor increases the pressure of the refrigerant gas which causes it to increase in temperature.

Do you want a versatile solution

SWP. Water heater with SWP heat pump Hot water finally costs less. + Efficiency + Savings + Wellbeing

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Heating in residential pools

ENERGY TOP. Condensing boiler solutions

Pool heating, efficiently

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

Efficient heating that won t cost the earth

HP WH SERIES HEAT PUMP WATER HEATER. 200l 300l HP200M1, HP250M1 / HP200M3, HP250M3, HP250M3C / HP200S1, HP300S1

PRODUCT RANGE HEAT PUMPS 2012

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Advance Split

High efficiency air to water Heat pumps LZT series

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

WHY A MHI HEAT PUMP?

For latest prices and delivery to your door visit MyTub Ltd

Technical information Master

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Tower Green HE Hybrid

and sanitary hot water Catalogue 2009

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

ROTEX HPDU monobloc Maximum efficiency in water heating

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

AHU Plus. DX Air Handling Units

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

recooler HP EQKR HEAT PUMP

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

New Panasonic Aquarea DHW. Domestic Hot Water Tanks

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

REMKO HYBRID HEAT PUMPS

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Technical description. Atec.

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Electric Water Heaters. The STRENGTHS of the product range in detail:

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

3 rd Generation of VRV. The professional solution for your professional project

Hot Water Heating Systems

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

v SELECTION GUIDELINES

NATURAL HEATING MACHINE

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Air Conditioning System

SWIMMING POOL HEAT PUMPS

DES IGN I T ALI A N O

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

MASTER VITRO - VITREOUS ENAMELLED STEEL. Models with COILS, production and efficiency! DHW PRODUCTION/STORAGE TANKS

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Conditioning your ambient, maximising your comfort.

Ciao Green Condensing Wall-Hung Boilers

AQUASNAP JUNIOR 30RHV

ONE SERIES CONDENSING WALL HUNG BOILERS. For further information visit our website ariston.com HOT WATER HEATING RENEWABLE AIR CONDITIONING

OCHSNER hot water heat pumps NATURAL HOT WATER

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

HI-WALL SPLIT SYSTEMS

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

ACCUMULATION OF EUROPEAN CLASS

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

The future is in the air

IT S NOT JUST SOLAR IT S SOLAHART

AUDAX Air-water heat pumps reversible with inverter single and three-phase

HITACHI line up: YUTAKI S 80 Very high water temperature Heat Pump

Since 1960 we have produced your hot water

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Transcription:

RANGE HEAT PUMP WATER HEATERS 1

HOW TO READ THE SYMBOLS The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning, to quickly and easily identify performance levels, understand the different ranges and evaluate purchasing criteria. SOLAR INTEGRATION Suitable for integration with solar systems. ECOLOGIC GAS R134A Thanks to the ecologic gas R134A will not damage the ozone layer. DEFROSTING SYSTEM System that prevents condensation water from freezing allowing nuos to work in heat pump function with external air at -5 C. HIGH EFFICIENCY HIGH EFFICIENCY Product characterized by high energy performance, lower energy consumption and pollutant emissions. ANTI LEGIONELLA Eliminates bacterial growth by an activation of an automatic cycle of heating the water in the kettle. SUPER SILENCE Low noise in all operation modes. IN THIS CATALOGUE WALL-HUNG HEAT PUMP WATER HEATER 16_ WALL HUNG 18_ EVO 20_ EVO SPLIT FLOOR STANDING HEAT PUMP WATER HEATER 22_ EVO SPLIT 300 24_ FLOOR STANDING 2

Efficiency is... saving and quality of life 3

The future is already here It heats the water using the air. It offers comfort respecting the environment. Ariston introduces : the wider and more complete ecological range of heat pump water heaters on the market, with high efficiency and energy saving. For many years Ariston has chosen a green path and for this reason it has been investing in the most advanced technology of its sector. Thanks to the research, we have developed the new heat pump water heaters. They are efficient and capable of heating a high quantity of water with an extremely low consumption of electricity, as they absorb the heat directly from the external air. WALL HUNG MONOBLOCK EVO 80-110 80-100-120 SPLIT EVO SPLIT 80-110 EVO SPLIT 150-200 heat pump water heater range is available both in monoblock and split version (with an external unit), and can be installed both on the wall and on the floor, with a capacity from 80 up to 300 litres. In the new buildings range can be used as an alternative to the solar thermal as renewable energy source. FLOOR STANDING 200-250-250 SOL EVO SPLIT 300 4

Heat pump technology range uses a thermodynamic cycle to heat the water inside the storage tank through the air sucked by the thermal group inverting the heat natural flow. A refrigerant fluid (R134A), through status changes, compression and expansion cycles, withdraws the heat in the air at low temperature and gives it to domestic water at a higher temperature. This is the reverse mechanism to the one used in refrigerators. The product electric consumption is only the one necessary to let the fan (that captures the air) and the compressor (that allows the refrigerant fluid to circulate in the system) work. ENERGY FORMULA electrical energy 100 = 25+75 renewable energy Hot water Electrical energy Air heat heat transferred to the water THERMODYNAMIC CYCLE A-B External air is aspirated inside the heat pump thanks to a fan; when passing through the fins of the evaporator, the air gives its heat and lose 10 C approx. Finally it is expelled. B compressor 1-2 The refrigerant fluid goes through the evaporator and absorbs the heat given by the air.during this process it changes its physical status and evaporate, keeping temperature and pressure almost constant. (0 C ; 5 bar). fan 2 3 hot water 2-3 The refrigerant fluid crosses the compressor and experiences a pressure rising which involves an increase of temperature. At the end of the process the fluid is overheated vapor and its temperature and pressure are 70 C and 20 bar respectively. evaporator 1 4 condenser 3-4 Within the condenser, the refrigerant fluid gives its heat to the water which warms up. By doing this, the refrigerant condensate at constant pressure (20 bar) and then experiences a significant reduction of temperature. (70 >40 C). 4-1 The refrigerant fluid passes through the lamination valve, suddenly loose both pressure and temperature and partially evaporate thus returning to the initial conditions of temperature and pressure. (40 >0 C; 5 bar). The thermodynamical cycle can now start over. air A thermal expansion valve tank heat generated by electricity heat generated by renewable source cold water 5

lots of advantages for you and for the environment RENEWABLE ENERGY The biggest innovation are usually hidden in what sorrounds us everyday. Air, for example, is rich in heat, a free and renewable energy directly coming from the sun. manages to extract this clean energy from the air and to use it to heat water. In this way, the electric consumption decreases and your comfort is guaranteed while the environment is protected. : ECOWATER EFFICIENT PRODUCT electric energy Nuos only uses 1/3 of the electric energy necessary to heat water compared to a traditional water heater. The C.O.P. (Coefficient Of Performance) defines the efficiency of the heat pump throught the ratio between the energy obtained and the energy given. This parameter is high above one, showing a great advantage in using. For every 100 units of heat given to the water, only 30 units of electric energy are required while the other 70 units are freely taken from the air. C.O.P. > 3 heat transferred to the water air s heat FLEXIBLE INSTALLATION has a wide range of air accessories that can fit any installation need. Whether you re planning to install a wall-hung or a floor-standing model, with or without canalization, has the perfect accessory to match your needs. Beside that, applied ecological technology results in one more positive aspects: air outcoming from the heat pump aid the natural ventilation of the room and increase air quality producing a pleasant refreshing and dehumidifying effect. : A BREATH OF FRESH AIR 6

heat pump: more than just a water heater WORKING PRINCIPLE The heat pump is a device which is used to transfer heat from the heat source at lower temperature to the heat source at higher temperature; this process is not spontaneous but requires a pumping work from the machine itself. An heat pump works like an hydraulic pump which, thanks to a certain amount of mechanical energy, moves the water from a lower level to an upper level, disregarding the normal laws of nature. THERMODINAMICAL HEAT PUMPS Expansion valve 1 4 Refrigerant fluid at liquid state Air outlet Renewable energy Air inlet Evaporator Compressor Electric energy Condenser 2 3 DHW inlet Total calorific energy DHW outlet Refrigerant fluid at gaseous state There are many physical principle thanks to which it is possible to perform the pumping of the heat: gas compression, Peltier s thermoelectric effect and the refrigeration cycle with phase change. In the case of an heat pump with phase change, a fluid evaporates and condensates at different temperature in a thermodynamical cycle, thanks to expansion and compression processes. When evaporating, the fluid subtracts heat from the source at lower temperature while when condensating the fluid gives back the heat to the source at higher temperature. The most important part of this machine is therefore a compressor driven by an electric motor. REFRIGERANT FLUID The thermodynamic characteristics of the fluid are a primary aspect to take into consideration for the proper working of the process. If, for example, heat is taken from a source at 10 C (i.e. external air) to be given to a source at 40 C (i.e. domestic hot water), the fluid evaporation has to take place at a temperature lower than 10 C and its condensation at temperature above 40 C. This fluids are called refrigerant fluid. The fluid used in heat pump water heater is R134A; it is harmless to the ozone layer, it does not contain chlorine, damaging for the environment, it is not toxic or flammable, all advantages for both the users and the installers safety. The R134A gas, thanks to high thermodynamic features, guarantees high efficiency. C.O.P. The C.O.P. (Coefficient Of Performance) shows the efficiency of this kind of machines as the ratio between total thermal Energy given and electric Energy absorbed. HIGH EFFICIENCY The heat pumps can use the free thermal energy of the surrounding environment. The quantity of free energy is much higher than the quantity of electric energy consumed, therefore the COP is generally higher than 2 and can reach values up to 6. 7

range Monoblock or Split? SPLIT MONOBLOCK Ariston offers a complete range of split and monoblock heat pump water heaters Integration with internal rooms The internal unit is more compact because it doesn t have the refrigeration unit The gas connections have extremely limited dimensions The condensate discharge is not necessary Architectonic integration The monoblock heat pump outside needs only discharge grates that don t have any visual impact. Air treatment The monoblock product allows to use the cold and dehumidified air for cooling the internal rooms through appropriate canalizations. Sound emission Fan and compressor are the main responsible for the sound emission in an aerothermal heat pump. Thanks to the external unit, the product doesn t cause any noise inside the installation room Trasport It is usually easier to transport two smaller and lighter parcels (internal and external unit). Installation The external unit installation needs minimum wall works. It is enough ø50 mm hole for the refrigerant gas pipes. Initial start-up The initial start-up is immediate as it is a plug&play product. The operator doesn t need refrigerator technician s skills and equipment. Maintenance The ordinary maintenance main operation of an aerothermal heat pump consists in cleaning the evaporator. This operation is easier in the external unit (if it is in a place easy to reach). 8

, the product range that fits any need 80-100-120 EVO 80-110 EVO SPLIT 80-110 EVO SPLIT 150-200 200-250-250 SOL EVO SPLIT 300 Guide to the choice by application New Single and Two family house New Multi-family house Exiting Single and Two-family house Existing Multi-family house Shop typical and advisable application possible application range for all the applications 9

and the market A record-proof quality! Through the experience and its continuous research, Ariston has developed the new range of water heaters, using advanced technologies. Both split and monoblock EVO models have in common some technical aspects that are absolutely innovative and make their characteristics unique on the market. COP* from 2.6 to 3,1* (air 7 C) from 3 to 3.7* (air 20 C) EVO can be applied as renewable source in the new buildings THE MOST EFFICIENT ON THE MARKET External air minimum working temperature - 5 C EVO guarantees the maximum saving also during the winter and in the coldest regions MAXIMUM EFFICIENCY IN COLD REGIONS Condenser External coil EVO guarantees the maximum safety and hygiene of the domestic water THE SAFEST ON THE MARKET Anode Double Electronic Pro-tech + Magnesium EVO guarantees the maximum protection and reduces the maintenance costs THE MOST RESISTANT ON THE MARKET Heating element Double in steatite** EVO allows to replace or inspect the heating element without emptying and it reduces the maintenance costs THE FASTEST MAINTENANCE ON THE MARKET 10 (*) according to the models and to EN 255-3 standard with water set-point temperature at 15-55 C ** Only for products with capacity higher than 120 litres

Heat pump water heater: very low energy consumption, high quantity of hot water. A PROFITABLE AND VERSATILE TECHNOLOGY By absorbing the free and ecologic heat directly from the air, the heat pumps are the best example of technology in complete harmony with the environment. The advantages of a heat pump water heater EVO concern not only the ecology but also the lower buying and installation costs, also compared to the solar thermal. For these reasons, today EVO is a really future-proof investment. However, our versatile technology offers also the possibility to integrate, with 250 SOL model, the solar thermal in the heat pump most advanced system. Can you imagine something more efficient, convenient and green? Something more than a green choice! 11

SINGLE-family solutions Domestic hot water from renewable source with heat pump water heater Heating with condensing wall-hung boiler up to 300 m 2 up to 8 people Also for big systems Easy to install No visual impact Component Range Heat pump water heater Condensing boiler wall-hung from 80 to 120 lt wall-hung split from 80 to 200 floor-standing from 200 to 250-250SOL floor-standing split 300 lt 12 kw 18 kw 24 kw 30 kw Legend Real simulation case study: 2 1 1 2 3 Heat pump Mixed wall-hung boiler Outdoor probe Basic condition 150 sm house in D class, in Rome. Gas conventional boiler 25 kw 3 4 5 High temperature zone Room sensor zone 1 Renewable solution sizing - Heat pump water heater 200 litres - Condensing boiler 24 kw A Domestic hot water outlet Results 5 B Cold water inlet 4 Total annual Gas saving 23% Annual CO2 avoided: kg 389 Equivalent trees: 32 B A Arrange an appropriate hydraulic safety group Results calculated by energy certification software 12

MULTI-family solutions Domestic hot water from renewable source with individual wall-hung heat pump water heater Centralized heating system with condensing boilers up to 80 flats No visual impact outside Comfort maximum control A low cost renewable solution Component Heat pump water heater Range wall-hung from 80 to120 split from 80 to 200 floor-standing from 200 to 250 Condensing boiler 45-65 kw 85-100 kw 4 Legend Real simulation case study: 6 7 1 2 3 4 Heating unit Kit ISPESL Cascade control unit Heat pump flat 1 Basic condition Block of 12 flats of 80 sm in D class, in Rome Centralized gas conventional boiler 45 kw A B 3 1 5 Circulation pump flat 1 6 High temperature zone flat 1 7 8 Timer-thermostat flat1 Heat pump flat 2 Renewable solution sizing - Heat pump water heater 80 litres - Condensing boiler Genus Premium HP 45 kw + kit ISPESL 4 5 9 Circulation pump flat 2 Results 11 9 10 High temperature zone flat 2 11 Timer- thermostat flat 2 Total annual gas saving 26% 10 2 Annual CO2 avoided: kg 2.402 Equivalent trees: 200 A B A Domestic hot water outlet B Cold water inlet Arrange appropriate hydraulic safety group Results calculated by energy certification software 13

Family feeling and functionality just one language with 1 ON/OF 2 Display 3 Knob 4 Smile LED 5 Mode 1 2 3 4 5 Just one user interface on all models. A great functionality with an easy and intuitive control panel. GREEN MODE Function that maximizes the energy saving. works only in heat pump mode heating the water up to 62 C. BOOST MODE Function that minimizes the heating time thus increasing the comfort. works at the same time with the heat pump and the heating element, speeding the water heating up. Once exceeded the maximum working temperature of the heat pump, the heating element keeps heating until the water set-point temperature. AUTO MODE Function that guarantees the best compromise between comfort and saving. Nuos optimizes the switching logic of the heat pump and heating element. ANTILEGIONELLA FUNCTION This function consists in an automatic disinfection cycles. Every month, carries out a control and, if necessary, it heats the water up to 65 C, keeping this temperature for a period of time long enough to destroy a possible proliferation of bacteria in the storage tank. PROGRAMMING It is the function that allows to set the time and water temperatures as you want. The device will reach the selected temperature at the set time (you can set up to two hours). The process will give priority to the heating by heat pump and, only if necessary, through the heating elements. 4,00 3,50 Energy consumption with water 15-55 C (EN 255-3) Traditional electric water heater (1200W) 05:16 04:48 Heating time with water 15-55 C (EN 255-3) Consumption (kwh) 3,00 2,50 2,00 1,50 1,00 BOOST mode GREEN mode Time (h,min) 04:19 03:50 03:21 02:52 02:24 01:55 BOOST mode GREEN mode Traditional electric water heater (1200W) 0,50 01:20 0,00-5 0 5 10 15 20 25 30 35 40 45 Room temperature ( C) 00:57-5 2 7 20 30 42 Room temperature ( C) 14

The ecological evolution is a cost benefit for everybody Considering the European Standard withdrawal profiles, the yearly energy consumption dedicated to the domestic hot water production is established to be equal to 1.550 kwh/ year for a family of 3 people. EVO average efficiency, estimated by evaluating its efficiency with an average annual temperature of the inlet air equal to 15 C, allows to save up to 1352 kwh/year compared to a traditional water heater with the same capacity. A visible and tangible saving on the electricity bill. consumption 250 W 2,5X100 W SMART INVESTMENT Rapid return on investment Efficiency means lower consumption: the heat pump water heater ensures an energy and cost saving that has a very short payback period, comparing its performances to those of an electric water heater with the same capacity. Considering the growing cost of electricity, efficiency will play more and more a primary role in the purchasing of a water heater: in this scenario represent the smartest investment. 15

WALL HUNG 80-100-120 Wall-hung heat pump water heater ECOLOGIC GAS R134A ANTI legionella COP 3,0 WITH AIR TEMPERATURE AT 20 C (EN 255-3) WORKING RANGE IN HEAT PUMP MODE WITH AIR TEMPERATURES FROM 10 TO 37 C. ECOLOGIC GAS R134A ALLOWS TO REACH WATER TEMPERATURES UP TO 55 C IN HEAT PUMP MODE BOILER IN TITANIUM ENAMELLED STEEL INTEGRATED HEATING ELEMENT ANTI-CORROSION DOUBLE ANODE IN MAGNESIUM DIGIT DISPLAY WITH TOUCH CONTROL ECO, FAST, AUTO, ANTILEGIONELLA FUNCTIONS AND TIME SETTING OF THE WITHDRAWALS Wall-hung installation. Available in 80, 100 and 120 litres. Technical data 80 100 120 COP air 20 C water 15-55 C (EN 255-3) 3,0 3,0 2,6 Min/max air temperature C 10/37 10/37 10/37 Air thermal power at 20 C (*) W 930 930 810 Average absorbed power (*) W 310 310 310 Air heating time at 20 C (*) H/min 4,05 5,40 7,48 Max. quantity of hot water at 40 C (*) lt 110 141 150 Storage tank capacity lt 80 100 120 Thermal losses in 24h W 0,64 0,64 0,68 Max. operating pressure bar 8 8 8 Voltage/ max. power consumption (*) V / W 220/1510 220/1510 220/1510 Heating element power W 1200 1200 1200 Standard air flow rate m3/h 150 150 150 Min. volume of the installation room (**) m3 20 20 20 Sound pressure level at 1 m db(a) 38 38 38 Weight when empty kg 42 46 51 Protection rating IPX4 IPX4 IPX4 Insulation thickness mm 45 45 45 Diameter of hydraulic connections 1/2M 1/2M 1/2M Min. temperature of the storage tank room C 1 1 1 (*) Water temperature 15-55 C with air at 20 C (EN 255-3) (**) Room minimum volume in case of installation without canalization MODEL 80 100 120 CODES 3210011 3210012 3210013 16

COMPRESSOR AIR FAN EVAPORATOR EXPANSION VALVE Time [hh.mm] 4,50 4,30 4,10 3,90 3,60 3,30 NOUS 80 COPt 3,60 3,40 3,20 3,00 2,80 2,60 3,00 2,40 10 15 20 25 30 35 40 Air temperature ( C) Time [hh.mm] COPt NOUS 100 6,50 3,80 6,30 3,60 6,00 3,40 5,70 3,20 5,30 3,00 5,00 2,80 4,70 2,60 4,30 2,40 4,00 2,20 10 15 20 25 30 35 40 Air temperature ( C) Water temperature 15-55 C (EN 255-3) Water temperature 15-55 C (EN 255-3) CONDENSER Time [hh.mm] 9,00 8,60 8,30 8,00 7,60 7,30 NOUS 120 COPt 3,20 3,00 2,80 2,60 2,40 2,20 7,00 2,00 10 15 20 25 30 35 40 Air temperature ( C) Water temperature 15-55 C (EN 255-3) Dimensions 80 100 120 a mm 1130 1280 1440 b mm 384 536 696 497 140 Ø125 525 156 Ø125 292 240 30 30 B A 300 OUT IN 497 G1/2 100 104 C Ø10 134 IN cold water inlet G 1/2 OUT hot water outlet G 1/2 C Discharge of condensate 17

EVO 80-110 Wall-hung heat pump water heater HIGH EFFICIENCY HIGH EFFICIENCY ECOLOGIC GAS R134A ANTI legionella COP 3,4 WITH AIR TEMPERATURE AT 20 C (EN 255-3) COP 2,6 WITH AIR TEMPERATURE AT 7 C (EN 255-3) WORKING IN HEAT PUMP MODE WITH AIR TEMPERATURES FROM - 5 TO 42 C. ECOLOGIC GAS R134A ALLOWS TO REACH WATER TEMPERATURES UP TO 62 C IN HEAT PUMP MODE CONDENSER COILED AROUND THE BOILER (NOT IMMERSED IN THE WATER) LOW NOISE (SILENT FUNCTION) BOILER IN TITANIUM ENAMELLED STEEL ADDITIONAL HEATING ELEMENT ACTIVE ANODE (PROTECH) + MAGNESIUM ANODE LCD DISPLAY GREEN, BOOST, AUTO, ANTILEGIONELLA FUNCTIONS AND TIME SETTING OF THE WITHDRAWALS Wall-hung installation. Available in 80 and 110 litres. Super compact, renewable product Technical data EVO 80 110 COP air 20 C water 15-55 C (EN 255-3) 3,4 3,4 COP air 7 C water 15-55 C (EN 255-3) 2,6 2,6 COP according to EN 16147 2,7 2,7 Min/max air temperature C -5/42-5/42 Air thermal power at 20 C (*) W 850 850 Average absorbed power (*) W 250 250 Air heating time at 20 C (*) h/min 4,15 6,30 Air heating time at 7 C (*) h/min 5,30 8,20 Max. quantity of hot water at 40 C (**) lt 113 169 Storage tank capacity lt 80 110 Thermal losses in 24h W 0,46 0,5 Maximum operating pressure bar 8 8 Voltage/ max. power consumption (*) V / W 220/1460 220/1460 Heating element power W 1200 1200 Standard air flow rate m3/h 100-200 100-200 Min. volume of the installation room (***) m3 20 20 Sound pressure level at 1 m db(a) 35 35 Weight when empty kg 50 55 Protection rating IPX4 IPX4 Insulation thickness mm 41 41 Diameter of hydraulic connections 1/2M 1/2M Min. temperature of the storage tank room C 1 1 (*) Water temperature 15-55 C with air at 20 C (EN 255-3) (**) Water temperature 15-62 C with air at 20 C (EN 255-3) (***) Minimum room volume in case of installation without canalization MODEL EVO 80 EVO 110 CODES 3603543 3603545 18

AIR FAN COMPRESSOR EXPANSION VALVE EVAPORATOR Time [hh.mm] EVO 80 08:38 07:26 06:14 05:02 03:50 02:38 02:26-5 2 7 20 42 Air temperature ( C) Water temperature 15-55 C (EN 255-3) COPt 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 CONDENSER Time [hh.mm] EVO 110 11:31 10:19 09:07 07:55 06:43 05:31 04:19-5 2 7 20 42 Air temperature ( C) Water temperature 15-55 C (EN 255-3) COPt 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 100 Dimensions 80 110 a mm 1171 1398 b mm 515 515 c mm 890 1117 184 IN OUT B C 380 99 A 152 535 145 99 IN Cold water inlet G 1/2 OUT Hot water outlet G 1/2 506 19

EVO SPLIT 80-110 Wall-hung heat pump water heater HIGH EFFICIENCY HIGH EFFICIENCY ECOLOGIC GAS R134A ANTI legionella Super silence COP 3,5 WITH AIR TEMPERATURE AT 20 C (EN 255-3) COP 2,9 WITH AIR TEMPERATURE AT 7 C (EN 255-3) WORKING RANGE IN HEAT PUMP MODE WITH AIR TEMPERATURES FROM - 5 TO 42 C. ECOLOGIC GAS R134A ALLOWS TO REACH WATER TEMPERATURES UP TO 62 C IN HEAT PUMP MODE CONDENSER COILED AROUND THE BOILER (NOT IMMERSED IN THE WATER) LOW NOISE (EXTERNAL UNIT) BOILER IN TITANIUM ENAMELLED STEEL ADDITIONAL HEATING ELEMENT ACTIVE ANODE (PROTECH) + MAGNESIUM ANODE LCD DISPLAY AUTO, BOOST, GREEN, VOYAGE, ANTILEGIONELLA FUNCTIONS AND TIME SETTING OF WITHDRAWALS Wall-hung installation. Available in 80 and 110 litres. Super compact and silent. Renewable product Technical data EVO SPLIT 80 110 COP air 20 C water 15-55 C (EN 255-3) 3,5 3,6 COP air 7 C water 15-55 C (EN 255-3) 2,9 2,9 COP according to EN 16147 2,61 2,61 Min/max air temperature C -5 / 42-5 / 42 Air thermal power at 20 C (*) W 1750 1750 Average absorbed power (*) W 510 510 Air heating time at 20 C (*) h/min 2,00 3,00 Air heating time at 7 C (*) h/min 2,45 3,42 Max. quantity of hot water at 40 C (**) lt 113 169 Storage tank capacity lt 80 110 Thermal losses in 24h W 0,46 0,5 Max. operating pressure bar 8 8 Voltage/ max. power consumption V / W 220/1950 220/1950 Heating element power W 1200 1200 Weight when empty kg 32 38 Protection rating IPX4 IPX4 Insulation thickness mm 41 41 Diameter of hydraulic connections 1/2M 1/2M Min. temperature of storage tank room C 1 1 EXTERNAL UNIT Diameter of refrigerant connections 1/4-3/8 flare type Weight when empty kg 27 Standard air flow rate m3/h 1100 Sound power db(a) 55 Sound pressure level at 5 m db(a) 39 Max. pressure of refrigerating circuit (low-pressure side bar 12 Max. pressure of refrigerating circuit (high-pressure side) bar 27 Protection rating IPX4 Max. distance between storage tank and external unit m 6 Max. height difference between storage tank and external unit m 3 (*) Water temperature 15-55 C with air at 20 C (EN 255-3) (**) Water temperature 15-62 C with air at 20 C (EN 255-3) MODEL EVO SPLIT 80 EVO SPLI T 110 PRODUCT CODE (storage tank + external unit) 3603546 3603547 Storage tank code 3603533 3603535 External unit code 3603536 20

CONDENSER Time [hh.mm] EVO SPLIT 80 5.02 4.33 4.04 3.36 3.07 2.38 2.09 1.40 1.12-5 2 7 20 30 42 Air temperature ( C) Riscaldamento da 15 a 55 C Water temperature 15-55 C (EN 255-3) COPt 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 EVAPORATOR AIR FAN EXPANSION VALVE COMPRESSOR Time [hh.mm] EVO SPLIT 110 7.12 6.00 4.48 3.36 2.24 1.12-5 1 7 20 30 42 Air temperature ( C) Water temperature 15-55 C (EN 255-3) COPt 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 502 204 Dimensions 80 110 a mm 858 1085 533,4 183,9 OUT IN OUT GAS IN GAS A 240 100 OUT IN 700 769 542 IN GAS OUT GAS IN cold water inlet G 1/2 OUT hot water outlet G 1/2 IN GAS gas inlet G 1/4 OUT GAS gas outlet G 3/8 321 254 534 83 21

EVO SPLIT 150-200 Wall-hung heat pump water heater HIGH EFFICIENCY HIGH EFFICIENCY ANTI legionella Super silence DEFROSTING SYSTEM ECOLOGIC GAS R134A COP 3,7 WITH AIR TEMPERATURE AT 20 C (EN 255-3) COP 2,9 WITH AIR TEMPERATURE AT 7 C (EN 255-3) COP WITH AIR TEMPERATURE AT 20 C (EN 16147) COP WITH AIR TEMPERATURE AT 7 C (EN 16147) WORKING RANGE IN HEAT PUMP MODE WITH AIR TEMPERATURES FROM - 5 TO 42 C. ECOLOGIC GAS R134A ALLOWS TO REACH WATER TEMPERATURES UP TO 62 C IN HEAT PUMP MODE CONDENSER COILED AROUND THE BOILER (NOT IMMERSED IN THE WATER) LOW NOISE (EXTERNAL UNIT) BOILER IN TITANIUM ENAMELLED STEEL HEATING ELEMENT IN DOUBLE POWER STEATITE ACTIVE ANODE (PROTECH) + MAGNESIUM ANODE LCD DISPLAY AUTO, BOOST, GREEN, VOYAGE, ANTILEGIONELLA FUNCTIONS AND TIME SETTING OF THE WITHDRAWALS Wall-hung installation. Available in 150 and 200 litres. Renewable product Technical data EVO SPLIT 150 200 COP air 20 C water 15-55 C (EN 255-3) 3,6 3,6 COP air 7 C water 15-55 C (EN 255-3) 2,9 2,9 COP according to EN 16147 2,61 2,7 Min/max air temperature C -5/ 42-5/ 42 Air thermal power at 20 C (*) W 2450 2450 Average absorbed power (*) W 680 680 Air heating time at 20 C (*) h/min 2,35 3,30 Air heating time at 7 C (*) h/min 3,25 4,35 Max. quantity of hot water at 40 C (**) lt 230 318 Storage tank capacity lt 150 200 Thermal losses in 24h W 0,49 0,52 Max. operating pressure bar 6 6 Voltage/ max. power consumption (*) V / W 220/2500 220/2500 Heating element power W 1500+1000 1500+1000 Weight when empty kg 60 65 Protection rating IPX4 IPX4 Insulation thickness mm 55 55 Diameter of hydraulic connections 3/4M 3/4M Min. temperature of storage tank room C 1 1 EXTERNAL UNIT Diameter of refrigerant connections 1/4-3/8 flare type Weight when empty kg 32 Standard air flow rate m3/h 1300 Sound power db(a) 60 Sound pressure level at 5 m db(a) 42 Max. pressure of refrigerating circuit (low-pressure side) bar 12 Max. pressure of refrigerating circuit (high-pressure side) bar 27 Protection rating IPX4 Max. distance between storage tank and external unit m 6 Max. height difference between storage tank and external unit m 3 (*) Water temperature 15-55 C with air at 20 C (EN 255-3) (**) Water temperature 15-62 C with air at 20 C (EN 255-3) MODEL EVO SPLIT 150 EVO SPLI T 200 PRODUCT CODE (storage tank + external unit) 3069412 3069413 Storage tank code 3069405 3069404 External unit code 3603528 22

CONDENSER Time [hh.mm] 4.33 4.04 3.36 3.07 2.38 2.09 1.40 1.12 EVO SPLIT 150-5 1 7 20 30 42 Air temperature ( C) Water temperature 15-55 C (EN 255-3) COPt 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 EVAPORATOR AIR FAN EXPANSION VALVE COMPRESSOR Time [hh.mm] EVO SPLIT 200 7.12 6.00 4.48 3.36 2.24 1.12-5 1 7 20 30 42 Air temperature ( C) Water temperature 15-55 C (EN 255-3) COPt 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Dimensions Ø 56 150 200 a mm 1150 1476 b mm 500 80 c mm 750 1050 604 OUT GAS IN GAS 80 175 385 15 A 832 762 C OUT IN B IN GAS OUT GAS 31 52 250 269 321 540 111 IN OUT IN cold water inlet G 1/2 OUT hot water outlet G 1/2 IN GAS gas inlet G 1/4 OUT GAS gas outlet G 3/8 In case of a not solid wall, it is advisable to use the tripod support code 3078042 23

FLOOR STANDING 200-250 - 250 sol Floor standing heat pump water heater HIGH EFFICIENCY HIGH EFFICIENCY ANTI legionella SOLAR INTEGRATION DEFROSTING SYSTEM ECOLOGIC GAS R134A COP 3,7 WITH AIR TEMPERATURE AT 20 C (EN 255-3) COP 3,1 WITH AIR TEMPERATURE AT 7 C (EN 255-3) WORKING RANGE IN HEAT PUMP MODE WITH AIR TEMPERATURES FROM - 5 TO35 C. ECOLOGIC GAS R134A ALLOWS TO REACH WATER TEMPERATURES UP TO 62 C IN HEAT PUMP MODE CONDENSER COILED AROUND THE BOILER (NOT IMMERSED IN THE WATER) BOILERIN TITANIUM ENEMELLED STEEL HEATING ELEMENT IN DOUBLE POWER STEATITE ACTIVE ANODE (PROTECH) + MAGNESIUM ANODE LCD DISPLAY FUNZIONI ANTILEGIONELLA, GREEN, BOOST, AUTO FUNCTIONS AND TIME SETTING OF THE WITHDRAWALS COIL AND PROBE-HOLDER FOR SOLAR AND/OR BOILER INTEGRATION INTEGRATED MULTI-DIAMETER AIR OUTLET SPLITTER INTEGRATED TRANSPORT STRAPS Display easy to use, -5 C inlet air min. temperature. Renewable product Dati tecnici 200 250 250 SOL COP air 20 C water 15-55 C (EN 255-3) 3,7 3,7 3,7 COP air 7 C water 15-55 C (EN 255-3) 3,1 3,1 3,1 COP according to EN 16147 2,61 2,8 2,8 Min/max air temperature C -5/ 35-5/ 35-5/ 35 Air thermal power at 20 C (*) W 2775 2775 2775 Average absorbed power (*) W 750 750 750 Air heating time at 20 C (*) h/min 3,30 4,03 4,03 Air heating time at 7 C (*) h/min 5,12 6,04 6,04 Max. quantity of hot water at 40 C (**) lt 348 435 435 Storage tank capacity lt 200 250 250 Thermal losses in 24h W 0,6 0,65 0,65 Max. operating pressure bar 6 6 6 Voltage/ max. power consumption (*) V / W 220/2500 220/2500 220/2500 Heating element power W 1500+1000 1500+1000 1500+1000 Standard air flow rate m3/h 300-500 300-500 300-500 Minimum volume of installation room (***) m3 20 20 20 Sound pressure level at 1 m db(a) 54 54 54 Weight when empty kg 90 95 110 Protection rating IPX4 IPX4 IPX4 Insulation thickness mm 50 50 50 Diameter of hydraulic connections 3/4M 3/4M 3/4M Min. temperature of storage tank room C 1 1 1 (*) Water temperature 15-55 C with air at 20 C (EN 255-3) (**) Water temperature 15-62 C with air at 20 C (EN 255-3) (***) minimum volume of installation room, for installation without canalizations MODEL 200 250 250 SOL CODE 3210031 3210017 3210018 24

COMPRESSOR EXPANSION VALVE AIR FAN EVAPORATOR CONDENSER Time [hh.mm] 200 8.24 7.12 6.00 4.48 3.36 2.24-5 0 7 10 15 25 35 Air t temperature( C) Water temperature 15-55 C (EN 255-3) COPt 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 SOLAR COIL Time [hh.mm] 250 09:36 08:24 07:12 06:00 04:48 03:36 02:24-5 0 7 10 15 25 35 Air temperature ( C) Water temperature 15-55 C (EN 255-3) COPt 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Dimensions 200 250 (SOL) H mm 568 820 G mm 1478 1738 L mm 1700 1960 ø 150 ø 160 ø 200 B 330 620 E D C A H G L ø 150 ø 160 ø 200 30 600 344 160 105 A Pipe Ø 3/4 cold water inlet B Pipe Ø 3/4 hot water outlet C Condensate discharge connection Ø 1/2 F D Pipe Ø 3/4 solar circuit inlet (250 SOL) E Pipe Ø 3/4 solar circuit out 600 25

EVO SPLIT 300 Floor-standing heat pump water heater HIGH EFFICIENCY HIGH EFFICIENCY ANTI legionella DEFROSTING SYSTEM ECOLOGIC GAS R134A Super silence COP 3,7 WITH AIR TEMPERATURE AT 20 C (EN 255-3) COP 2,9 WITH AIR TEMPERATURE AT 7 C (EN 255-3) WORKING RANGE IN HEAT PUMP MODE WITH AIR TEMPERATURES FROM - 5 TO 42 C. ECOLOGIC GAS R134A ALLOWS TO REACH WATER TEMPERATURES UP TO 62 C IN HEAT PUMP MODE CONDENSER COILED AROUND THE BOILER (NOT IMMERSED IN THE WATER) LOW NOISE (EXTERNAL UNIT) BOILER IN TITANIUM ENAMELLED STEEL HEATING ELEMENT IN DOUBLE POWER STEATITE ACTIVE ANODE (PROTECH) + MAGNESIUM ANODE LCD DISPLAY ANTILEGIONELLA, GREEN, BOOST, AUTO FUNCTIONS AND TIME SETTING OF THE WITHDRAWALS Super silence, -5 C inlet air min. temperature. Renewable product Technical data EVO SPLIT 300 COP air 20 C water 15-55 C (EN 255-3) 3,6 COP air 7 C water 15-55 C (EN 255-3) 2,9 COP according to EN 16147 2,7 Min/max air temperature C -5/ 42 Air thermal power at 20 C (*) W 2450 Average absorbed power (*) W 680 Air heating time at 20 C (*) H/min 5,30 Air heating time at 7 C (*) H/min 7,15 Max. quantity of hot water at 40 C (**) lt 549 Storage tank capacity lt 300 Thermal losses in 24h W 0,63 Max. operating pressure bar 6 Voltage/ max. power consumption (*) V / W 227&2500 Heating element power W 1500+1000 Weight when empty kg 87 Protection rating IPX4 Insulation thickness mm 50 Diameter of hydraulic connections 3/4M Min. temperature of storage tank room C 1 EXTERNAL UNIT TECHNICAL DATA Diameter of refrigerant connections 1/4-3/8 flare type Weight when empty kg 32 Standard air flow rate m3/h 1300 Sound power db(a) 60 Sound pressure level at 5 m db(a) 42 Max. pressure of refrigerating circuit (low-pressure side) bar 12 Max. pressure refrigerating circuit (high-pressure side) bar 27 Protection rating IPX4 Max. distance between storage tank and external unit m 6 Max. height difference between storage tank and external unit m 3 (*) Water temperature 15-55 C with air at 20 C (EN 255-3) (**) Water temperature 15-62 C with air at 20 C (EN 255-3) MODEL EVO SPLIT 300 PRODUCT CODE (storage tank + external unit) 3069414 Storage tank code 3069403 External unit code 3603528 26

CONDENSER Time [hh.mm] 10.48 9.36 8.24 7.12 6.00 4.48 3.36 2.24 EVO SPLIT 300-5 1 7 20 30 42 Air temperature ( C) COPt 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Water temperature 15-55 C (EN 255-3) EVAPORATOR AIR FAN EXPANSION VALVE COMPRESSOR 30 Dimensions 300 H mm 1820 ø mm 634 1820 832 762 IN 366 IN GA OUT G ø 600 540 111 IN GAS 542 634 80 OUT GAS OUT IN Cold water inlet G 3/4 OUT Hot water outlet G 3/4 IN GAS Gas inlet G 1/4 OUT GAS Gas outlet G 3/8 45 269 321 27

Possibility of air canalization The air can be canalized both at the inlet and at the outlet in order to direct the flow appropriately in many different situations. range has many air accessories that can fit any installation need. WALL-HUNG MONOBLOCK 80-100-120, EVO 80-110 FLOOR-STANDING MONOBLOCK 200-250-250 SOL EVO 80-110 Maximum duct length 10 m (duct ø 125 mm) 28 Maximum duct length 10 m (duct ø 150 mm)and 25 m (duct ø 200 mm)

Installation flexibility WALL-HUNG SPLIT EVO SPLIT 80-110-150-200 FLOOR-STANDING SPLIT EVO SPLIT 300 Max. linear distance 8 m between the storage tank and the eternal unit. Max. height difference 3 m between the storage tank and the external unit. 29

ACCESSORIES Canalization ø 125 mm Code EVO 80-110 EVO SPLIT 80-110 EVO SPLIT 150-200 80-100-120 EVO SPLIT 300 200-250- 250SOL Perimeter wall air kit Kit made by: ABS connection for pipe ø 125 mm; 1 m.l. PVC round pipe ø 125 mm and flexible grates with ø 186 mm springs and hole from ø100 to 160 mm; 15 mm thickness. Perimeter wall air kit Kit made by: ABS elbow for pipe ø 125 mm; 1 m.l. PVC round pipe ø 125 mm and flexible grates with ø 186 mm springs and hole from ø 100 mm to 160 mm; 15 mm thickness. Inner wall air kit Kit made by: ABS vertical elbow from ø 125 mm to rectangular mm 150x70; 1,5 m.l. PVC rectangular pipe 150x70 mm; ABS horizontal connection from ø 125 mm to rectangular 150x170 mm; 1 m.l. PVC round pipe ø 125 mm; flexible grates with ø 186 mm springs and hole from ø 100 to 160 mm; 15 mm thickness and 2 wall brackets for pipe 150 x 70 mm with screws 5 x 45 and nylon plugs. 3208052 3208092 3208053 PVC pipe ø125 mm and 1,5 m.l. length 3208036 PVC pipe ø 125 mm and 1 m.l. length 3208037 ABS connection for ø 125 mm round pipe 3208038 Flexible connection ø 125 mm 3208039 ABS 90 elbow f.f. ø 125 mm 3208040 Wall brackets for pipe ø 125 mm with screws 5x45 and nylon plugs 3208041 ABS cover 190x160 mm for round pipes ø 100-125 3208049 ABS vertical elbow from ø 125 mm to rectangular 150x70 mm 3208042 ABS horizontal connection from Ø 125 mm to rectangular 150x70 mm 3208043 PVC rectangular pipe 150x70mm and 1,5m.l. length 3208044 ABS connection for rectangular pipe 150x70 mm 3208045 ABS vertical elbow for rectangular pipe 150 x 70 mm 3208046 ABS horizontal elbow for rectangular pipe 150 x 70 mm 3208047 2 wall brackets for pipe 150 x 70mm with screws 5 x 45 and nylon plugs 3208048 Flexible grates with ø 186 mm springs, hole from ø 100 to 160 mm, 15 mm thickness 3208050 30

ACCESSORIES Canalization ø 150 mm Code EVO 80-110 EVO SPLIT 80-110 EVO SPLIT 150-200 80-100-120 EVO SPLIT 300 200-250- 250SOL AIR KIT WITH RIGID PIPE Ø150 (2,5M) The kit consists of flexible grate with springs, two rigid pipes (1 and 1,5 m) and a connector. AIR KIT WITH RIGID PIPE Ø150 (2,5M) The kit consists of flexible grate with springs, two rigid pipes (1 and 1,5 m) and an elbow. 3208061 3208093 AIR KIT WITH FLEXIBLE PIPE Ø150 The kit consists of flexible grate with springs, a flexible pipe (1m), two rigid pipes (0,1 and 1 m), 3 wall brackets 3208062 Pipe ø150 1 m 3208063 Pipe ø150 1,5 m 3208064 Pipe ø150 0,1 m 3208065 Connection ø150 3208066 90 elbow ø150 3208067 2 wall brackets for pipe ø150 3208068 Flexible pipe ø150 1 m 3208069 Canalization ø 200 mm Code EVO 80-110 EVO SPLIT 80-110 EVO SPLIT 150-200 80-100-120 EVO SPLIT 300 FS 200-250- 250SOL AIR KIT WITH RIGID PIPE Ø200 The kit consists of flexible grate with springs, two rigid pipes (1 and 2 m) and a connector. 3208071 Pipe ø200 1m 3208072 Pipe ø200 2m 3208073 Connection ø200 3208074 90 elbow ø200 3208075 45 elbow ø200 3208076 2 wall brackets for pipe ø200 3208077 Flexible grate with springs ø165-200 3208078 Silencer ø200 3208085 Installation accessories Code EVO 80-110 EVO SPLIT 80-110 EVO SPLIT 150-200 80-100-120 EVO SPLIT 300 FS 200-250- 250SOL Flexible connection 3208051 Safety hydraulic group ½ 877084 Safety hydraulic group ¾ 877085 Siphon 1 877086 External unit wall support 704101 External unit floor support 3380020 Tripod support 3078042 31

Ariston Thermo Group disclaims all responsabilty for possible printing or transcription mistakes of this catalogue. Furthermore, it reserves the right to change, without notice, the specifications and information of the products contained herein. ARISTON THERMO GROUP Ariston Thermo SpA Viale A. Merloni, 45 60044 Fabriano (AN) - ITALY Fax: 0732 602416 www.ariston.com