Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Similar documents
icomfort Residential Communicating Control System Equipment Interface Module (EIM)

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

ELITE Series Variable Capacity

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

ELITE Series Variable Capacity

PRO Installation. Thermostat Wi-Fi

Thermostats. Thermostats

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Save energy from anywhere, easily.

CB X 32 mv

PRO Installation. Touch Wi-Fi Thermostat

Safety & Installation Instructions

PRO Installation. Touch Wi-Fi Thermostat

EL-TSTAT-8820 Safety & Installation Instructions

Safety & Installation Instructions

icomfort E30 Smart Thermostat Installation and Setup Guide Disponible en español en www. lennoxpros.com.

MISCELLANEOUS ENGINEERING DATA EXPANSION VALVE CROSS-REFERENCE DATA PRODUCT SPECIFICATIONS

Safety & Installation Instructions

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

icomfort E30 Smart Thermostat Installation and Setup Guide /2018 Supersedes Lennox Industries Inc. Dallas, Texas, USA

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

WARNING This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.

VisionPRO 8000 with Wi-Fi

RCS Residential Control Systems Inc.

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

LZP-2 ZONE CONTROL PANEL

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Installation and Setup Guide

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

! icomfort E30 Smart Thermostat. ! icomfort Wi-Fi Touchscreen Thermostat. ! icomfort S30 Ultra Smart Thermostat. ! ComfortSense 7500 Series

Daikin ENVi Thermostat installation overview

What is the Carrier Connect Wi-Fi Thermostat?

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

Thermostats and Zoning Systems

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Safety & Installation Instructions

Advanced Installation and Configuration Instructions

Thermostats Zoning Systems

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

T-32-TS Touchscreen Thermostat. Installation Manual

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

Safety & Installation Instructions

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Verasys System Operation Overview Technical Bulletin

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

What is the Carrier Connect Wi-Fi Thermostat?

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

Commercial Touchscreen Thermostat

Installation Instructions

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

1F98EZ-1421, Easy Install

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

SYST0101CW Product Specifications

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Installation, Start-Up, and Operating Instructions

Installation Instructions

essential comfort Furnaces

York 25-Ton VAV Rooftop Unit

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Product Manual SZ1009

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Safety & Installation Instructions

Installer Guide. WARNING Important Safety Information. 1 Specifications

cool and comfortable Air Conditioners

MERIT SERIES Downflow

Digi-Zone. Installation and Operating Instructions. Model MDP3. Controlling Your Comfort Room By Room

7-Day. Digital Thermostat. residential. & 2-cool

Installation, Operation, and Troubleshooting Instructions

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

HOMEOWNER S MANUAL. Harmony III Zone Control System. IMPORTANT: Read this instruction manual completely! Retain for future reference.

Table of Contents. Discharge Air Upper Limit and Differential Temp General Information... 8

Emerson Blue Easy Set 1H/1C

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

AFUE 95% Heating Input 50,000 to 200,000 Btuh

The XP21 raises the bar for efficiency and comfort.

installation and start-up instructions THERMIDISTAT CONTROL

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

up to 98.7% efficiency can save over $800 a year** The SLP98V is a choice you can feel good about.

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

Transcription:

PRODUCT SPECIFICATIONS ZONING IHARMONY Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems Bulletin No. 20663 November 207 Supersedes August 205 COMPONENTS AND EQUIPMENT CONTENTS Component Selection... 9 Damper Control Module Connections... 6 Features... 2 Sequence Of Operation... 7 System Components... 5 System Components Ordering... 8 SYSTEM OVERVIEW The iharmony Zoning System is capable of controlling up to four separate zones. Zone dampers are automatically controlled to supply air flow only to zones with a thermostat demand. Individual air volumes for heating or cooling are available to each zone. Round or rectangular dampers can be used. Zoning system allows temperature setback in unoccupied areas while maintaining comfort in occupied areas. Auto-changeover control from any zone thermostat or control heating/cooling mode to all zones from the icomfort Communicating Thermostat (Zone master). EQUIPMENT WARRANTY iharmony Damper Control Module and In-Zone Thermostats - Five year limited warranty in residential applications and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. System Components iharmony Damper Control Module (DCM) icomfort Communicating Thermostat (Zone master) In-Zone Thermostats (one per Zone, 2, 3 and 4) Motorized Zone Dampers Discharge Air Temperature Sensor (furnished) NOTE - All components must be ordered separately. Damper Control Module and Zone Dampers are powered by a separate stand-alone transformer. Outdoor Units SL8XC Single Stage Air Conditioner (two zones) SL8XP Single Stage Heat Pump (two zones) XC2 Two-Stage Air Conditioner (up to four zones) XP2 Two-Stage Heat Pump (up to four zones) XC20/XC25 Variable Capacity Air Conditioner (up to four zones) XP20/XP25 Variable Capacity Heat Pump (up to four zones) Variable Speed Furnaces EL296V Two-Stage SL280V Two-Stage SLP98V Variable Capacity Variable Speed Air Handlers CBX32MV CBX40UH NOTE - The iharmony Zoning System may be used with all icomfort Communicating indoor/outdoor units shown above. A conventional, noncommunicating outdoor unit may also be used as long as the indoor unit is one of the icomfort Communicating models shown above. NOTE - Only icomfort Communicating heat pump outdoor units may be used with a dual-fuel system.

FEATURES IHARMONY DAMPER CONTROL MODULE (DCM) Microprocessor controlled panel contains all necessary relays and controls to operate the system. Automatic reset in case of operation error or power failure. Diagnostic codes are sent to and stored directly on the icomfort Communicating Thermostat and are displayed on the Alerts screen. If a zoning-related alert occurs the system defaults to Zoning Off mode (all dampers open). LEDs on control indicate RSBus communication (green), status (green), In-Zone thermostat communication (green), damper closed operation (red), Zoning Off operation (red) and pressure switch open (red). Transformer jumper allows the use of an external transformer (DMPR XFMR) to power the Damper Control Module (DCM), In-Zone Thermostats and Zone Dampers, or use the system transformer on the indoor unit (SYS XFMR) to power only the Damper Control Module (DCM) and In-Zone Thermostats. Default setting is the external transformer (DMPR XFMR). TRANSFORMER JUMPER SETTINGS Component Power DMPR XFMR (external-default) SYS XFMR (indoor unit) Damper Control Module Yes Yes In-Zone Thermostats Yes Yes Zone Dampers Yes No Power to zone dampers must be supplied by a separate external transformer. Terminal (G) for continuous IAQ blower operation. Adjusts the indoor blower air volume from continuous blower speed to the correct zone heating or cooling blower speed when any zone has a heating or cooling demand. Built-in time delay function (5 minutes) prevents short cycling of system. 3A (slow-blow) fuse protects panel from short circuits in the thermostat and damper field wiring. Cabinet and removable cover constructed of high impact plastic. Holes for mounting are furnished and electrical inlets are provided in cabinet. Dimensions (H x W x D): 0-/2 x 5 x -5/8 in. (267 x 27 x 4 mm). Shipping weight: 2 lbs. Power requirements: 24VAC (8-30VAC). DISCHARGE AIR TEMPERATURE SENSOR (furnished) Field installed in supply air plenum. Senses discharge air temperature to control system. Relays information through the Damper Control Module to icomfort Communicating Thermostat to control first and second stage heating and cooling based on discharge air temperature. The temperature settings are controlled by the icomfort Communicating Thermostat. ICOMFORT THERMOSTATS icomfort S30 Ultra-Smart Thermostat (part of the icomfort Residential Communicating Control System) The icomfort S30 Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7 in. high definition color display (measured diagonally). Works with Amazon Alexa-enabled products. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S30 Thermostat Product Specifications bulletin in the Controls section for more information. iharmony Zoning System / Page 2

FEATURES ICOMFORT THERMOSTATS (continued) icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or e-mail. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7-inch color screen (measured diagonally). Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. Outdoor Temperature Sensor Used with the icomfort Communicating Thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for dual-fuel and Humiditrol applications. NOTE - The outdoor sensor is furnished as standard with icomfort Communicating outdoor units, optional for conventional units. IN-ZONE THERMOSTATS Auto-changeover control from any In-Zone Thermostat if icomfort Communicating Thermostat is set to auto-changeover for that zone. Programming for each zone is configured and controlled by the icomfort Communicating Thermostat. E Ink display with white LED front light. Displays current zone temperature in center of screen and current operating mode setpoint (COOL TO / HEAT TO) at top or bottom of screen. Fahrenheit or Celsius display depending on settings at the icomfort Communicating Thermostat. Push buttons (Up/Down arrows) on case allow user to adjust zone temperature setpoints (in increments) directly from the In-Zone Thermostat. Buttons are illuminated when pressed to show cooling (blue) or heating (red) mode. Pressing both buttons simultaneously switches between heating and cooling mode if master thermostat (icomfort Communicating Thermostat) is set for Heat or Cool for that zone. Pressing both buttons for 0 seconds briefly displays zone address. When zone is in Away Mode (icomfort Communicating Thermostat setting) the screen display is reversed (light characters/dark background). Temperature measurement range: 32 to 99 F. Rotary DIP switch on back of thermostat sets zone address (2 to 4 only). Zone address is set with plastic screwdriver furnished with Damper Control Module (DCM). In-Zone Thermostats operate on 2VDC. Dimensions (H x W x D): 3 x 3 x 5/8 in. (76 x 76 x 6 mm). Friction lock wiring connections. Connects directly to the Damper Control Module (RSBus) using standard 4-wire, 8-gauge thermostat wiring (field supplied), or with furnished 4-wire, 22-gauge solid-wire extensions secured to the In-Zone Thermostat and connected to standard thermostat wiring with supplied wire nuts. Metal thermostat baseplate furnished with wall anchors and screws for mounting. Zone thermostat is easily removed from baseplate. Thermostat mounting plate (with wall anchors and screws) is furnished to cover an existing opening or mount the thermostat directly to a single-gang junction box in either vertical or horizontal orientation. iharmony Zoning System / Page 3

FEATURES ADDITIONAL CONTROLS Freezestat Only required for small zones with minimal airflow. Installed on indoor coil. High Pressure Switch A high pressure switch is required for applications with a heat pump. Guards against high head pressures during first- and second-stage heating. Transformer 24VAC transformers are required for operation of the Damper Control Module, In-Zone Thermostats and Zone Dampers. The Damper Control Module requires 6VA and the In- Zone Thermostats require 3VA. These can be powered by a separate external transformer or the system (indoor unit) transformer. Transformer size is determined by the total power requirements of the Damper Control Module, In-Zone Thermostats and Zone Dampers. Zone Dampers will require a separate 24V transformer. Additional (extended) zone dampers require additional transformers. Zone Damper VA can vary from 6 to 2VA each. See damper manufacturer s specifications to determine total VA required. See page 8 for transformer ordering information. DAMPERS Zone Dampers Any style 24VAC damper is compatible with the iharmony Zoning System. Spring-open/power-close dampers are the preferred, however, power-open/springclose and power-open/powerclose dampers can be used. NOTE - Modulating dampers may not be used. At least one damper per zone is required. Up to 5 dampers per zone may be connected in parallel to the iharmony Damper Control Module, not to exceed a total of six dampers for entire system. If additional dampers are required, refer to the special wiring diagram in the Installation Instructions for additional information about extended dampers, transformers and zone relays. iharmony Zoning System / Page 4

SYSTEM COMPONENTS icomfort Smart Hub Controller icomfort S30 High Definition Color Display with Mag-Mount Mounting System (Master Zone ) icomfort S30 Web and Mobile Apps RSBus icomfort Communicating Air Conditioner or Heat Pump (or conventional non-communicating outdoor unit, not for Dual Fuel Systems) High Pressure Switch (Heat Pump Only) Conventional Wiring Freezestat (Indoor Coil) RSBus Discharge Air Temperature Sensor (DATS) Damper Control Module (DCM) RSBus icomfort Communicating Furnace or Air Handler LEGEND RSBus Conventional Wiring Zone Damper Extended Zone Dampers Zone 2 Damper Extended Zone 2 Dampers Zone 3 Damper Extended Zone 3 Dampers Zone 4 Damper Extended Zone 4 Dampers 24V Transformer (See System Components Ordering) Zone 2 In-Zone Thermostat Conventional Wiring Zone 3 In-Zone Thermostat RSBus Zone 4 In-Zone Thermostat Additional 24V Transformers for Extended Zone Dampers iharmony Zoning System / Page 5

DAMPER CONTROL MODULE CONNECTIONS Discharge Air Temperature Sensor Pressure Switch Freezestat IAQ Damper Transformer Not used Blower Transformer Jumper Indoor Unit (RSBus) RSBus LED LEDs (Status, Central, PSW) Fuse Damper LEDS (one per zone) (future use) In-Zone Thermostats (Zones 2, 3, 4) (RSBus) Zone Dampers and 2 Zone Dampers 3 and 4 In-Zone Thermostats LED Component Type Type of Connection Damper Transformer (DMPR XFMR) 2-wire R C Power Common Discharge Air Temperature Sensor (DATS) 2-wire C Sense Common Sensor Freezestat 2-wire Sense 24VAC Sensor Power IAQ Blower (G) 2-wire Sense 24VAC Sensor Power (not used) In-Zone Thermostats RSbus (4-wire) PWR D+ D C Power RSBus Data Send RSBus Data Receive Common Indoor Unit (INDOOR) RSbus (4-wire) R I+ I C Power RSBus Data Send RSBus Data Receive Common Pressure Switch (PRESSURE SW) 2-wire Sense 24VAC Sensor Power ZONE DAMPERS (Zones - 2) (Zones 3-4) 2-wire DCOM NC NO Common Normally Closed Normally Open (Zones 2, 3 and 4) iharmony Zoning System / Page 6 Terminal Designation Terminal Description

SEQUENCE OF OPERATION When power is first applied, the green Status LED will flash, indicating that the Damper Control Module (DCM) is functioning normally. When the control is first powered on, there is a 5-minute minimum off-time delay during which only the fan output will respond. HEAT/COOL CHANGEOVER When a demand for heating or cooling exists in one zone and an opposing demand is made from another zone, a 20-minute time period is initiated. If the original demand is not satisfied within the 20-minute time period, the original demand will be interrupted, turning the equipment off and initiating a 5 minute time delay to allow system temperatures and pressures to stabilize. The opposing demand will then be initiated. This cycle will continue until there are no simultaneous opposing demands. DAMPER OPERATION Cooling Operation Conventional Heat/Cool and Heat Pump Systems When an In-Zone Thermostat makes a demand for cooling, the zone damper opens and cooling operation begins. Cooling demand is terminated when:. All zone demands for cooling are satisfied. 2. The demand has exceeded the heat/cool changeover time limit (20 minutes) while a heating demand exists. When cooling demand is terminated, a 5-minute minimum off time delay is initiated. Second-stage cooling is energized when the discharge air temperature is 7 F higher than the setpoint of the cooling stage temperature setpoint on the icomfort Communicating Thermostat. Heating Operation Conventional Heat/Cool and Heat Pump Systems When an In-Zone Thermostat makes a demand for heating, the zone damper opens and heating operation begins. Heating demand is terminated when:. All zone demands for heating are satisfied. 2. The demand has exceeded the heat/cool changeover time limit (20 minutes) while a cooling demand exists. When heating demand is terminated, a 5 minute minimum off time delay is initiated. Second-stage heating is energized when the discharge air temperature is lower than the setpoint of the heating stage temperature setpoint on the icomfort Communicating Thermostat. DUAL-FUEL OPERATION NOTE - Only icomfort Communicating heat pump outdoor units may be used with a dual-fuel system. When a gas furnace and a heat pump are both present in the system, the icomfort Communicating Thermostat uses the balance point settings to determine which source to use for heating. When the outdoor temperature is above the low balance point, heat pump operation is always initiated first before gas furnace operation. In order to use the gas furnace as a primary heating source (not defrost tempering) when the outdoor temperature is between the high and low balance points, the following conditions must occur: Heat pump operation must occur for a minimum of 30 minutes. Temperature in the zone must not increase by more than 0.5 F. Heat pump has not entered defrost mode in the 30 minute period. If any single-zone is satisfied at the specified conditions, heat pump operation will stop and the gas furnace will be used to satisfy all heating demands for the next duration of the parameter heat pump lockout time. After the heat pump lockout has expired, the heat pump is again used as the primary heat source on the next demand after the equipment has stopped. Emergency Heat Operation Heat Pump Systems When emergency heat is enabled on the icomfort Communicating Thermostat the indoor unit satisfies all heating demand with electric backup heat (gas heat if a dual fuel system is used). When the Emergency Heat setting is OFF, the heat pump is used to satisfy heating demands. Humiditrol Whole Home Dehumidification Operation The Humiditrol Whole-Home Dehumidification System can be used with the iharmony Zoning System. When a Humiditrol is installed it is enabled through the icomfort Communicating Thermostat. See the icomfort Communicating Thermostat Product Specifications for details. iharmony Zoning System / Page 7

SYSTEM COMPONENTS ORDERING icomfort S30 Thermostat (Zone Master) icomfort Wi-Fi Thermostat (Zone Master) Description Catalog No. 2U67 0F8 Optional Outdoor Air Temperature Sensor X2658 Damper Control Module (DCM) (Discharge Air Temperature Sensor furnished) In-Zone Thermostat - One per zones 2, 3 and 4 0C6 0C7 Transformers 20/208/240V primary / 24V secondary - 40VA (3 dampers) 0P7 20/208/240V primary / 24V secondary - 50VA (4 dampers) 20/208/240V primary / 24V secondary - 75VA (6 dampers) 0P87 2P6 4 in. square Electrical Box 83P74 2 High Pressure Switch - Heat Pump only 27W3 Freezestats - For use with Humiditrol system 3/8 in. (Open 29 F / Close 58 F) 93G35 Dampers Zone Control Power Close / Spring Open Round - Two Wire Rectangular Bottom Mount - Two Wire Rectangular Side Mount - Two Wire 6 in. Round X4207 0 in. Round X42 7 in. Round X4208 2 in. Round X423 8 in. Round X4209 4 in. Round X424 9 in. Round X420 6 in. Round X425 8 in. x 0 in. X4252 0 in. x 8 in. X4263 8 in. x 2 in. X4253 0 in. x 20 in. X4264 8 in. x 4 in. X4254 0 in. x 22 in. X4265 8 in. x 6 in. X4255 0 in. x 24 in. X4266 8 in. x 8 in. X4256 2 in. x 4 in. X4267 8 in. x 20 in. X4257 2 in. x 6 in. X4268 8 in. x 22 in. X4258 2 in. x 8 in. X4269 8 in. x 24 in. X4259 2 in. x 20 in. X4270 0 in. x 2 in. X4260 2 in. x 22 in. X427 0 in. x 4 in. X426 2 in. x 24 in. X4272 0 in. x 6 in. X4262 8 in. x 8 in. X426 20 in. x 0 in. X4233 0 in. x 8 in. X427 22 in. x 0 in. X4234 2 in. x 8 in. X428 24 in. x 0 in. X4235 4 in. x 8 in. X429 26 in. x 0 in. X4236 6 in. x 8 in. X4220 30 in. x 0 in. X4238 8 in. x 8 in. X422 2 in. x 2 in. X4239 20 in. x 8 in. X4222 4 in. x 2 in. X4240 22 in. x 8 in. X4223 6 in. x 2 in. X424 24 in. x 8 in. X4224 8 in. x 2 in. X4242 26 in. x 8 in. X4225 20 in. x 2 in. X4243 28 in. x 8 in. X4226 22 in. x 2 in. X4244 30 in. x 8 in. X4227 4 in. x 4 in. X4246 0 in. x 0 in. X4228 6 in. x 4 in. X4247 2 in. x 0 in. X4229 8 in. x 4 in. X4248 4 in. x 0 in. X4230 20 in. x 4 in. X4249 6 in. x 0 in. X423 22 in. x 4 in. X4250 8 in. x 0 in. X4232 24 in. x 4 in. X425 The Optional Outdoor Air Temperature Sensor may be used with an icomfort Communicating outdoor unit for a secondary (alternate) sensor reading. Optional Outdoor Air Temperature Sensor may also be ordered for use with a conventional outdoor unit. 2 Required for Heat Pump applications. iharmony Zoning System / Page 8

COMPONENT SELECTION START INDOOR UNITS Lennox icomfort Communicating Thermostat Indoor Unit equipped with Variable Speed Blower (Gas Furnace with Indoor Coil or Air Handler Unit) OUTDOOR UNITS Two Zones Lennox icomfort Communicating Single-Stage Air Conditioner or Heat Pump Outdoor Unit (For system with two equal size zones) OUTDOOR UNITS Two, Three or Four Zones Lennox icomfort Communicating Variable Capacity or Two- Stage Air Conditioner or Heat Pump Outdoor Unit (For two, three or four zone systems) In-Zone Thermostat (0C7) (one per zone) icomfort S30 (0F8) or icomfort WI-FI (2U67) Communicating Thermostat (Zone Master) High Pressure Switch (Heat Pump applications only) R-40A - (27W3) iharmony Damper Control Module (0C6) with Discharge Air Temperature Sensor (furnished) Zone Dampers (at least one per zone) Transformer 20/208/240V primary/ 24V secondary 40VA (0P7) 50VA (0P87) 75 VA (2P6) Freezestats 3/8 in. (93G35) STOP A conventional, non-communicating outdoor unit may also be used as long as the indoor unit is icomfort Communicating. NOTE - Dual Fuel Systems - Only icomfort Communicating heat pump outdoor units may be used with a dual fuel system. iharmony Zoning System / Page 9

REVISIONS Sections Document Description of Change Revised icomfort -enabled to icomfort Communicating. icomfort -enabled no longer means communicating with the advent of the E30 and M30 thermostats. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 207 Lennox Industries, Inc.