Product Data. FH4A Fan Unit. Sizes 001 thru 004

Similar documents
Product Data. FH4A Fan Unit. Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

Installation Instructions

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

FEM4X. Product Specifications FAN COILS /14/15

Installation Instructions

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

Product Data MECH. Mechanical Filter Air Cleaner

WAHL A Product Specifications

Installation Instructions

Product Data. HUM Humidifiers

Dimensions H x W x D in. (mm)

Installation Instructions

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

Installation Instructions

FXM4X. Product Specifications FAN COILS FXM4X

REM4P, REM4X. Product Specifications

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Product Data FE4A, FE5A EVOLUTION SERIES COMMUNICATING VARIABLE SPEED FAN COIL PURON REFRIGERANT SIZES 002 THRU 006

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

FCM4X. Product Specifications

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

INSTALLATION INSTRUCTION

HIGH EFFICIENCY AIR HANDLER

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

HIGH EFFICIENCY AIR HANDLER

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Ruud Standard Efficiency Air Handler

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Ruud Standard Efficiency Air Handler

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Standard Efficiency Air Handler

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Rheem High Efficiency Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Electric Heat Accessory Installation Instructions

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

MODELS B1PA024, 030 AND 036

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Ruud High Efficiency Air Handler

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

Rheem High Efficiency Air Handler

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Installation Instructions

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Cooling/Heat Pump Convertible Air Handlers

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Cooling/Heat Pump Convertible Air Handlers

INSTALLATION INSTRUCTION

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Installation Instructions

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

TECHNICAL SPECIFICATIONS

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Transcription:

Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install, with capacities ranging from 800 to 2000 CFM. The units are the right choice if you need versatility and affordability in a fan unit. These fan units offer an air handler for practical, no-nonsense application and outstanding performance. The multipoise units allow greater flexibility to meet your upflow, downflow, or horizontal installation requirements, and offer multiple electric entry to permit quick, hasslefree hookup (003 and 004 when coupled with coil are upflow/downflow only). All models feature the components you need and expect. Every unit comes fully equipped with solid-state cooling controls and each terminal board is prewired to accept an electronic air cleaner. The FH4A, with its 3-speed motor and field-installed heater package, provides the application versatility required for most installations. Heater packages are available from 3 through 30 kw, either fused or with a circuit breaker, or non-fused for 0 kw and less. Homeowners like the compact size and attractive finish of the units, and appreciate the low-maintenance, easyto-clean permanent filter in our multipoise units. There are plenty of reasons to choose the model FH4A fan unit just check the specifications. Copyright 996 Carrier Corporation Form FH4A-3PD

Features Prepainted galvanized sheet metal Cooling controls with every unit 3-speed motors Multipoise units Factory-supplied cleanable filter Easy access filter for cleaning no tools required Field-installed heater packages 3 30 kw (fused, circuit breaker, non-fused) Factory-supplied power plug Control board with built-in, replaceable 5-amp blade-type auto fuse Foil faced high-density, super thick R 4.2 insulation Multiple electric entry HUD approved for manufactured housing 40-va, 208/230-v transformer All models listed with UL, cul, ARI, and RADCO Model number nomenclature F H 4 A N F 00 05 AEAA F Fan Coil 4 Multipoise H Standard Fan Unit A Original Series N 208/230--60 00 800 CFM 002 200 CFM 003 600 CFM 004 2000 CFM F Single Piece Cabinet with in. Super Thick Insulation Electric Heater (kw) 003 05 005 020 008 024 009 030 00 A Common Unit E Minor Engineering Change A Standard Unit A Standard Unit UNITARY AIR CONDITIONING UNITARY HEAT PUMP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 20 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 CERTIFICATION LISTING TESTING INSPECTION CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 2

Dimensions TOP VIEW 7 8 DIA KNOCKOUTS FOR LOW VOLTAGE CONTROL WIRING 7 8 NOTE: Allow 2 In. from front for service. 22 6 5 6 5 6 C B 3 8 7 8, 3 32, 2 DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING 2 8 0 3 6 OUTLET AIR 7 8 DISCONNECT OR CIRCUIT BREAKER LOCATION 3 4 BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL ALTERNATE 7 8 DIA KNOCKOUT FOR LOW VOLTAGE ACCESS PANEL CONTROL WIRING ALTERNATE 7 8, 3 32, 2 DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE A FITTING PANEL OPENING F INLET AIR FRONT VIEW FILTER ACCESS PANEL 4 9 3 OPENING 6 INLET AIR RIGHT SIDE VIEW A95533 UNIT SERIES A B C F ACCY. COIL CONFIGURATION In. In. In. In. SLOPE A OPERATING WEIGHT (Lb) FH4ANF00 E 42-/6 4-5/6 2-7/6 2-5/6 75 FH4ANF002 E 49-5/8 7-5/8 5-3/4 5-5/8 92 FH4ANF003 E 49-5/8 2-/8 9-/4 9-/8 06 FH4ANF004 E 53-7/6 2-/8 9-/4 9-/8 4.5 3

Dimensions continued * HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM, HOLES PROVIDED.36 IN. DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. 3 6 AIRFLOW 7 6 TYP (4 PLACES)* TYP (2 PLACES)* 2 5 6 2 3 6 TYP (2 PLACES)* 7 8 HORIZ LEFT UPFLOW AIRFLOW 2 3 6 TYP (2 PLACES)* 5 6 TYP (2 PLACES)* 7 6 TYP (4 PLACES)* DOWNFLOW 3 6 2 HORIZ RIGHT 2 7 8 A95534 4

Dimensions continued POWER ENTRY OPTIONS FIELD SUPPLIED SUPPLY DUCT LOW VOLT ENTRY OPTIONS 24-IN. FRONT SERVICE CLEARANCE UNIT FH4A00,002 FH4A003,004 A 2 In. 7 In. 2 9 2 2 A FIELD MODIFIED SIDE RETURN LOCATION FOR SLOPE COIL UNITS ONLY FIELD SUPPLIED RETURN PLENUM A95590 *Side Return not compatible when used in conjunction with accessory cooling coil. Fig. 4 Field Modified Side Return Location 5

Physical data UNIT SIZE 00 002 003 004 FAN Air Discharge Cfm (Nominal) Motor Hp (PSC) 850 /4 FILTER 2-/2 x 3 2-/2 x 6-3/8 2-/2 x 9-7/8 300 /3 700 3/4 2000 3/4 Performance data SIZE FH4A00 FH4A002 FH4A003 FH4A004 FH4A FAN UNIT AIRFLOW* EXTERNAL STATIC PRESSURE (IN. WC) BLOWER 0.0 0.20 0.30 0.40 0.50 0.60 SPEED 208 230 208 230 208 230 208 230 208 230 208 230 HIGH 73 270 35 225 090 70 045 26 993 058 925 98 MED 900 025 875 99 847 963 80 922 768 869 695 802 LOW 579 687 560 663 537 639 505 60 45 554 384 467 HIGH 630 84 605 798 567 748 525 696 480 629 45 560 MED 244 438 225 407 90 383 70 342 4 308 00 265 LOW 00 72 985 47 955 6 930 094 908 062 850 024 HIGH 28 2060 2202 949 206 853 989 MED 757 206 745 206 734 985 76 943 686 890 624 802 LOW 290 535 286 535 28 528 277 55 263 467 245 43 HIGH 2257 2235 288 23 2336 MED 930 225 94 296 887 263 838 206 787 2047 LOW 620 88 620 870 63 864 607 853 594 836 562 802 * With factory approved filter, 0-kw elec heat 00 and 002 sizes, 5 kw elec heat 003 and 004 sizes 230-volt. MODEL AND SIZE FH4A00 WITH KFAEC00024 FH4A002 WITH KFAEC020036 FH4A003 WITH KFAEC030048 FH4A004 WITH KFAEC040060 BLOWER MOTOR SPEED AIRFLOW PERFORMANCE WITH ACCESSORY COIL EXTERNAL STATIC PRESSURE (IN. WC) 0.0 0.20 0.30 0.40 0.50 0.60 208 230 208 230 208 230 208 230 208 230 208 230 HIGH 945 975 900 930 840 870 780 805 695 725 560 595 MED 835 900 795 855 745 800 690 740 60 650 470 50 LOW 605 695 575 665 530 625 485 580 425 50 340 395 HIGH 485 550 425 490 365 420 300 350 230 275 50 90 MED 235 380 200 325 60 265 0 20 055 40 985 070 LOW 035 85 00 50 980 5 940 070 890 00 825 935 HIGH 880 935 785 830 700 735 65 645 520 555 430 460 MED 740 840 660 750 585 660 50 575 435 485 350 390 LOW 425 605 395 555 360 495 35 430 255 360 70 270 HIGH 245 2245 2085 285 2030 25 965 2045 905 975 830 895 MED 2025 275 970 20 95 2050 860 990 805 905 740 830 LOW 680 895 655 855 625 80 595 765 555 705 500 645 NOTES:. Airflow based upon dry coil at 230v with factory approved accessory filter and electric heater (0 kw electric heat, sizes 00 and 002; 5 kw electric heat, sizes 003 and 004). 2. Not recommended for use above 0.60 in external static pressure. Airflows in this region have the potential for condensate to blow out of the drainpan. If usage in this region is desired, consult duct static pressure graph for allowable return and supply duct static pressures. Airflows in this region are outside recommended airflow for all applications. Usage at these airflows could result in condensate blowing out of the drainpan. FILTER STATIC PRESSURE DROP CFM UNIT SIZE 400 600 800 000 200 400 600 800 2000 00 0.044 0.075 0.0 002 0.072 0.00 0.30 003 0.092 0.20 0.52 004 0.20 0.52 0.87 6

0.6 0.5 TOO HIGH TOTAL STATIC PRESSURE (AIRFLOW TOO LOW) SUPPLY STATIC PRESSURE, IN.W.C. 0.4 0.3 0.2 ACCEPTABLE RANGE TOO HIGH RETURN STATIC PRESSURE (DIFFICULT TO MAKE TRAP) 0. TOO HIGH AIRFLOW* (WATER MAY BLOW OUT OF PAN PRIOR TO MAKING TRAP] 0 0 0. 0.2 0.3 0.4 0.5 0.6 RETURN STATIC PRESSURE, IN.W.C. A96027 ACCEPTABLE DUCT CONDITIONS For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the Acceptable Range illustrated above. These acceptable duct conditions apply to FH4 units used with accessory evaporator coils. * Operation in this Too High Airflow range (below.2 supply static) do not apply to the FH4. 7

Accessory electric heaters ELECTRIC HEATERS * Field convertible to phase. Field convertible to 3 phase. Approved for Canadian application. ** Blower motor heat not included. Electrical data SMART HEAT FAN COIL ELECTRICAL DATA (Units Without Electrical Heat) INTERNAL CIRCUIT PROTECTION HEATER PART NO., @ 240V VOLTS/PHASE / STAGE FAN COIL SIZE USED WITH KFAEH00N03 3 230/ 3 00 9,400 KFAEH020N05 5 230/ 5 00, 002 5,700 KFAEH030N08 8 230/ 8 00 004 25,00 KFAEH040N0 0 230/ 0 00 004 3,400 KFAEH060F20 20 230/ 0, 0 002 004 62,800 KFAEH08035 5 230/3 5, 0 002 004 47,00 KFAEH09038 8 230/3 6, 6, 6 003, 004 56,500 KFAEH00F24 24 230/3* 8, 8, 8 003, 004 75,300 KFAEH0F30 30 230/3* 0, 0, 0 003, 004 94,00 KFAEH30C05 5 230/ 5 Circuit Breaker 00, 002 5,700 KFAEH40C08 8 230/ 8 Circuit Breaker 00, 002 25,00 KFAEH50C0 0 230/ 0 Circuit Breaker 00 004 3,400 KFAEH70C20 20 230/ 0, 0 Circuit Breaker 002 004 62,800 KFAEH90S20 20 230/ 0, 0 002 004 62,800 KFAEH250N09 9 230/ 3, 6 002 004 28,200 KFAEH260F5 5 230/ 5, 0 00 004 47,00 KFAEH270S5 5 230/ 5, 0 00 004 47,00 KFAEH280C5 5 230/ 5, 0 Circuit Breaker 00 004 47,00 INTERNAL CIRCUIT PROTECTION * Use copper wire only. 75 C must be used in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60 C conductors, instead of wire sizes shown in table above per NEC 993 Article 336-26. Length shown is as measured way along wire path between unit and service panel for a voltage drop not to exceed 2%. FLA Fuill Load Amps ELECTRIC HEATER INTERNAL PROTECTION HEATING CAP. ** @ 230V HEATER PART NO., @ 240V VOLTS/PHASE / STAGE FAN COIL SIZE USED WITH KFAEH220H0 0 230/ 4, 6 00, 002 3,400 KFAEH230H5 5 230/ 3, 8, 4 00 003 47,00 KFAEH240H20 20 230/ 5, 0, 5 002 004 62,800 HEATING CAP. ** @ 230V BRANCH CIRCUIT MIN Max Wire VOLTS CKT Min Wire Length (Ft) UNIT SIZE ( PHASE) FLA AMPS Size AWG* 208v 230v Amps 00 208/230 2.0 2.5 4 250 275 5 002 208/230 3.2 4.0 4 50 75 5 003 208/230 5.5 6.9 4 90 00 5 004 208/230 5.4 6.8 4 90 00 5 HEATER PHASE FUSES QTY/SIZE CKT BKR QTY/SIZE 3 5 2/60 8 2/60 0 2/60 5 4/60 4/60 20 4/60 4/60 24 3/ 0 30 3/ 0 9 /3 5 3 8 3 8

ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT HEATER PART NO. KFAEH00N03 KFAEH020N05 KFAEH30C05 KFAEH030N08 KFAEH40C08 KFAEH250N09 KFAEH040N0 KFAEH50C0 KFAEH260F5 KFAEH270S5 KFAEH280C5 KFAEH08035 KFAEH09038 KFAEH060F20 KFAEH70C20 KFAEH90S20 * 240V 208V 3 2.3 5 3.8 5 3.8 8 6.0 8 6.0 9 6.8 0 7.5 0 7.5 5.3 5.3 5.3 5.3 8 3.5 20 5.0 20 5.0 20 5.0 PHASE 3 3 3 INTERNAL CIRCUIT PROTECTION Ckt Bkr Ckt Bkr Ckt Bkr Ckt Bkr Ckt Bkr CIRCUIT 0.9/2.0 8./20.0 8./20.0 28.9/32.0 28.9/32.0 8.8/20.8 54.2/59.9 54.2/59.9 3.3/34.6 37.6/4.5 72.3/79.9 72.3/79.9 HEATER AMPS L, L2 L3, L4 8./20.0 8./20.0 8./20.0 CIRCUIT L, L2 L3, L4 6.2/7.5 3.2/33.5 3.2/33.5 43.0/46.9 43.0/46.9 30.4/32.9 52.2/56.9 52.2/56.9 74.7/8.8 74.7/8.8 46.0/50.2 53.9/58.8 97.3/06.8 97.3/06.8 MIN AMPACITY ** 52.2/56.9 22.7/25.0 52.2/56.9 22.7/25.0 52.2/56.9 22.7/25.0 52.2/56.9 52.2/56.9 52.2/56.9 45.3/50.0 45.3/50.0 45.3/50.0 MIN WIRE SIZE (AWG) CIRCUIT L, L2 L3, L4 2/2 4/4 4/4 8/6 3/2 3/2 0/0 0/0 0/0 MIN GND WIRE SIZE CIRCUIT L, L2 L3, L4 2/2 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 FUSE/CKT BKR AMPS CIRCUIT L, L2 L3, L4 9 6.8 32.8/36.0 47.9/5.9 0/0 50/60 94/96 20/20 40/40 40/40 45/50 45/50 35/35 60/60 60/60 80/90 80/90 50/50 60/60 00/0 00/0 60/60 25/25 60/60 25/25 60/60 25/25 60/60 50/50 60/60 60/60 50/50 50/50 MAX. WIRE LENGTH (FT) CIRCUIT L, L2 L3, L4 63/65 5 5 2 2 08/ 86/87 86/87 7/2 94/95 84/06 84/06 58/58 58/58 58/58 KFAEH00F24 KFAEH0F30 24 8.0 24 8.0 30 22.5 30 22.5 3 3 50./55.4 86.7/95.5 62.9.2 09.0/ 20.0 69.5/76.2 6.0/27.0 85.2/93.4 43.0/ 57.0 4/4 / 3/3 0/00 80/80 25/50 90/00 50/75 6/7 2/3 20/2 4/45 SMART HEAT ELECTRICAL DATA BRANCH CIRCUIT HEATER PART NO. KFAEH220H0 KFAEH230H5 KFAEH240H20 240V 208V PHASE 0 7.5 32.5/35.9 5.3 54.2/59.9 39.7/43.9 4.4/6.0 20 5.0 INTERNAL CIRCUIT PROTECTION CIRCUIT 72.3/79.9 HEATER AMPS L, L2 L3, L4 CIRCUIT L, L2 L3, L4 44.6/48.9 74.6/8.7 49.7/54.9 24.9/26.8 97.3/06.8 MIN AMPACITY ** 52.2/56.9 45.3/50.0 MIN WIRE SIZE (AWG) CIRCUIT L, L2 L3, L4 4/4 0/0 3/2 0/0 0/0 0/0 MIN GND WIRE SIZE CIRCUIT L, L2 L3, L4 0/0 0/0 FUSE/CKT BKR AMPS CIRCUIT L, L2 L3, L4 50/50 80/90 50/60 30/30 00/0 60/60 50/50 0/02 90/9 9/9 69/70 84/06 MAX. WIRE LENGTH (FT) CIRCUIT L, L2 L3, L4 58/58 FIELD MULTIPOINT WIRING OF 24- AND 30- PHASE HEATER PART NO. KFAEH00F24 KFAEH0F30 HEATER AMPS MIN AMPACITY MIN WIRE SIZE (AWG) MIN GND FUSE/CKT BKR AMPS MAX. WIRE LENGTH ** WIRE SIZE (FT) 240V 208V PHASE L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L6 24 8.0 30 22.5 28.9/32.0 28.9/32.0 28.9/32.0 43.0/46.9 52.2/56.9 36./40.0 45./50.0 36./40.0 45./50.0 0/0 0/0 45/50 60/60 40/45 50/60 40/45 50/60 2 73/73 58/58 73/73 58/58 * ** Field convertible to 3 phase. Field convertible to phase, single or multiple supply circuit. Approved for Canadian application. Includes blower motor amps of largest fan coil used with heater. Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). Length shown is as measured way along wire path between unit and service panel for a voltage drop not to exceed 2%. NOTE: Single circuit application of F5 and F20 heaters requires single-point wiring kit accessory. A96053 9

HEATER ELEMENTS ELECTRIC HEATER STATIC PRESSURE DROP FH4A00, 002 FH4A003, 004 EXTERNAL STATIC PRESSURE CORRECTION EXTERNAL STATIC PRESSURE CORRECTION HEATER ELEMENTS 0 0 +0.02 0 0 +0.04 3, 5 +0.0 2 8, 0 +0.02 2 8, 0 0 3 9, 5 0 3 9, 5 0.02 4 20 0.02 4 20 0.04 6 8, 24, 30 0.0 The airflow performance data was developed using fan coils with 0-kw electric heaters (2 elements) in the 00 and 002 units and 5-kw heaters (3 elements) in the 003 and 004 size units. For fan coils with heaters of a different number of elements, the available external static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. Carrier accessories ACCESSORY PART NO.* SIZE USED WITH Disconnect Kit KFADK00DSC Cooling Controls and Heaters 3 kw Through 0 kw Downflow Base Kit KFACB00CFB 00 KFACB020CFB 002 KFACB030CFB 003, 004 Downflow Conversion Kit KFADC020SLP Slope Coil Units 00, 002 KFADC040ACL A-Coil Units 003, 004 Single-Point Wiring Kit KFASP00SPK 5 and 20 kw Filter Kit (2 pack) KFAFK02SML 00 KFAFK022MED 002 KFAFK032LRG 003, 004 Required for Operation Without Electric Heat KFAPP025PLG All Sizes Evaporator Coil KFAEC050024 00 KFAEC060036 002 KFAEC030048 003 KFAEC040060 004 Accessory Kits Description Suggested and Required Use. Evaporator Coil Kit The kit contains a heating/cooling coil and drain pan. SUGGESTED USE: Accessory coil used with FH4A fan unit. 2. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: FK4, FC4, FB4, FA4, and FH4 units for 3kw through 0kw electric resistance heaters and cooling controls. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils. REQUIRED USE: This kit must be used whenever FK4, FC4, FB4, FA4, and FH4 fan coils are used in downflow applications. 4. Downflow Base Kit This kit is designed to provide a in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap free seal with the floor. REQUIRED USE: This kit must be used whenever FK4, FC4, FB4, FA4, and FH4 fan coils are used in downflow applications. 5. Single Point Wiring Kit The single point wiring kit acts as a jumper between L and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy-gage, high-voltage wires into the fan coil rather than 4 light-gage, high-voltage wires. SUGGESTED USE: FK4, FC4, FB4, FA4, and FH4 fan coils only with 5kw and 20kw heaters. 6. Fan Coil Filter The kit consists of 2 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system. SUGGESTED USE: To replace the filters in FK4, FC4, FB4, FA4, and FH4 fan coils. 0

Matched system HEAT PUMP HUMIDIFIER FAN COIL AIR FLOW ELECTRONIC AIR CLEANER A93474

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG -800-962-922 [ ] Packaged Service Training [ ] Classroom Service Training A94328 Printed on recycled paper. Carrier Corporation Syracuse, New York 322 3-96 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 4 Page 2 Catalog No. 92-32FH-4A3C Printed in U.S.A. PC 0 Form FH4A-3PD Tab 3d 2e Replaces: FH4A-2PD