OptoYag M. clear vision

Similar documents
OptoSLT M. preserve vision

clear & preserve vision OptoYag&SLT

The focused solution for YAG laser procedures

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

SURGICAL LIGHTS. Gleamer Exam Lights EQUIPMENT SURGICAL

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Human-Oriented Medical Laser Company. ELESYS Company introduction

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

WHAT IS LASER ULTRASONIC TESTING?

More Precision. thicknesssensor // The sensor for precise thickness measurements

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

LASER SAFETY PLAN OPHTHALMOLOGY

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

Laser Safety Program ELI-NP

Wavelengths: From UV to Visible and IR COBRA TM Max

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

CLEAN-LASERSYSTEME GMBH

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Phone: Fax: Web:

LM-80V , h V LM-30V h V

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Class 1 laser beam sensor safe for your eyes

Smart Fiber Lasers for Micro Machining Applications

The Optical Scattering Calibration System at SNO+ IOP 2015

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

MITSUBISHI ELECTRIC ANNOUNCES DEVELOPMENT OF 5.6 W 213 nm DEEP ULTRAVIOLET SOLID STATE LASER

CALIBRATION HOW IT WORKS

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

LASER SAFETY BARRIER

Class 1 laser beam sensor safe for your eyes

palmotdr Series Handheld OTDR

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

OWNERS MANUAL OPERATION GUIDE

High Intensity LED Strobe Light - 10 Watt - 10~30 Volts DC - Permanent Mount - 14 Strobe Patterns

Class 1 laser beam sensor safe for your eyes

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

Laser Safety Per Söderberg

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

FLX380-30x FlexTester OTDR

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Dual Laser InfraRed (IR) Thermometer

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

7680W Skid Mount LED Light Plant - (16) 480W LED Fixtures V AC 1-Phase - Crane Light

AEROSOL SPECTROMETERS

BGA Rework Station Pro-660

North Dakota State University Laser Safety

TH955. It aims high the TH955

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Heidelberger Straße Berlin Germany. phone +49(0) fax +49(0)

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Basic Laser Safety Training

IWASAKI ELECTRIC CO., LTD

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

AS/NZS IEC :2014

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

VECTOTHOR FLYING INSECT CONTROL LIGHT TRAPS

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Intrusion sensors. We listened to you

CO 2 Laser. High Reliability and Performance

Solo PIV Nd:YAG Laser System Operator s Manual

Dual Laser InfraRed (IR) Thermometer

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Product data sheet Palas Fidas 200 S

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

palmotdr Series Handheld OTDR

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Break-in Detection and Alarm System

100W Portable Explosion Proof LED Light - (2) LED Lamps - Non-Spark Aluminum Base - Inline Switch

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Specifications Wavelength Range: 190 nm to 800 nm continuous

Physics Requirements for the CXI Detector Stage

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Lasers in Veterinary Practice. Safe Use Guidelines

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Cemar Electro Inc. MAXX-606/607 Patient Positioning Laser. Installation and Set-up Manual

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

S ATION EWORK ST BGA R

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

New Standard Requirements and Possibilities using UV-LED lamps for fluorescent Magnetic- Particle- (MPI) and Penetrant Inspection (FPI) in Aerospace

Company profile and Products

Noyes OFL 250B Specs Provided by

Transcription:

clear vision OptoYag M

clear vision OptoYag M The OptoYag M utilizes a combination of latest innovations in Nd:YAG laser technology and highly efficient e-slitlight LED slit lamp. Compact design, 30 energy levels in the range of 0.5 10 mj, dual red aiming beam allowing precise focusing of the treatment beam, and built-in safety features guarantee the impeccable performance of the laser system. The OptoYag M is therefore a system of choice for fast, effective and safe capsulotomy and iridotomy procedures. STREAM OF TECHNOLOGIES FOR SUPERIOR EFFECTIVENESS Optotek has listened very carefully to those who use photodispruptor on a daily basis, paying special attention to YAG laser effectiveness. The OptoYag M is a synergy of optimized focusing optics, high accuracy and precision of the aiming beam system, and clean and stable Gaussian laser beam profile. Having excellent photodisruptor capability, the OptoYag enables best treatment results using lower energy and fewer shots. 1e-SlitLight HIGH POWER LED ILLUMINATION SYSTEM Tired of replacing slit lamp bulb? Want to have a brighter light? The e-slitlight LED slit lamp offers thousands of hours of bright white light originating from the solid state LED light source. The LED illumination enhances color, detail and contrast and therefore significantly improves imaging. Additionally, its minimal heat emission makes the treatment comfortable even for dry eye patients.

2FES - Fine Energy Setting FOR UNMATCHED PRECISION Advanced technical solutions and sophisticated electronics incorporated into the OptoYag M allow for a precise adjustment of energy in order to match the specific needs of the therapy or the patient. Fine energy setting buttons are conveniently located just next to a joystick, offering a physician easy and accurate adaptation of energy to the patient s eye response. This means the physician has 30 energy levels to choose from unique feature making OptoYag M a top class in photodisruption. 3PPS - Pulse to Pulse Stability FOR ADVANCED SAFETY Optotek has spent extra time and effort to ensure highest reliability and safety of the system. The OptoYAG M incorporates a PPS technology for delivering stable output energy far exceeding current industry standards. Enhanced accuracy and stability of energy provide the highest degree of safety and assure effective and efficient eye treatments. Output energy conventional laser technology PPS technology Pulses

4Treatment at 3 Hz FOR HIGHER PERFORMANCE The OptoYag M with newly designed laser cavity and optimized system configuration features repetition rate at 3 Hz. Faster treatment shifts physician s productivity and patient s comfort to a completely new level. 5Easy-to-move System Convenient portable design allows ophthalmologists to change location with ease. Having electronics box underneath the table, the system can be moved freely to another worktop and therefore instantly ready for use.

clear vision OptoYag M TECHNICAL SPECIFICATIONS LASER Laser Source Q-switched Nd:YAG Wavelength 1064 nm Energy 0,5 to 10 mj per pulse in 30 steps Spot Size < 10 μm Cone Angle 16 Offset Selectable: 150µm anterior; 0; 150, 300 µm posterior Pulse Rate Up to 3 Hz Burst Mode 1, 2 and 3 pulses Pulse Duration 4 ns (typical) Aiming Beam Red dual diode; 650 nm; continuously adjustable intensity (635, 670 nm optionally) Laser Trigger Cooling System Joystick (footswitch optionally) Air convection SLIT LAMP Type Illumination Source Magnification TABLE Type Dimensions SYSTEM DIMENSIONS YAG Laser Dimensions Total System Height WEIGHT Total Net Weight ELECTRICAL REQUIREMENTS Power Supply ACCESSORIES Optional Accessories e-slitlight White LED 10x, 16x, 25x (6x, 10x, 16x, 25x, 40x optionally) Central mounted 600 x 480 mm 125 x 257 x 68 mm 650 mm 21 kg 100-240 V, 50-60 Hz, 1,1 A MAX Motorized lifting mechanism, Footswitch, Elbow support, Beam splitter with co-observation tube, Warning light, Magnification changer (5x) Specifications are subject to change without notice.

Design by: Ana Vedlin, Photo: Aleksander Lilik, June 2013 With many years of experience in ophthalmic lasers, Optotek has a clear vision of its mission to deliver the innovative tools and solutions to the ophthalmologists worldwide. Designing and manufacturing User-friendly, Safe, Effective, and Reliable products is a key element of Opototek s corporate philosophy. www.optotek.si OPTOTEK d.o.o. Tehnološki park 21, 1000 Ljubljana, Slovenia T: +386 1 620 46 00, F: +386 1 620 46 01, E: optotek@optotek.si