MAKING MODERN LIVING POSSIBLE. Check valve for EVRA, EVRAT and PM valves in liquid lines type NRVS. Technical brochure

Similar documents
Thermostatic expansion valves for ammonia Type TEA

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Check valve Types NRV and NRVH

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Quick closing oil drain valve QDV

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

General information on refrigerant controllers

2,500 tons CO2 emission reductions 20% Application guide to CO2 secondary coolant systems

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Liquid Distributor Type RD

Refrigerant Valves/Accessories

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

OIL SEPARATORS APPLICATIONS

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

For more Parts Information:

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Tube-in-tube heat exchanger Type HE

Tube-in-tube heat exchanger Type HE

food-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Electromechanical cold controls for refrigerators and freezers MAKING MODERN LIVING POSSIBLE. Type description

Liquid Drainers LIQUID DRAINERS

Menu operation via AKM ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

Typical Piping Diagram

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

Thermostatic Expansion Valves Type TR 6

MODEL URS-1: FACTORY RETROFIT PROGRAM

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Operation Manual R205BV, R209BV

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Industrial Refrigeration systems in Potentially Explosive Atmospheres (Hazardous area) ATEX 94/9/EC Directive [ATmosphères EXplosives]

SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel)

The full range of Evaporator Controls from ADAP-KOOL

Installation, Operation, and Maintenance Information

PULSE WIDTH MODULATING VALVES

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

Capacity controller for water chiller AK-CH 650

PWM expansion valves 2028

One. Save time and money Streamline your heat pump business! makes a difference.

CABINET PARTS For Models: KSBP25FKSS01 (Stainless Steel)

Technical data. Danfoss DHP-A

CABINET PARTS For Models: KSCS25FKSS00 (Stainless Steel)

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

CABINET PARTS For Model: KBLC36FTS06 (Stainless Steel)

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

Measure Guidelines. for EnergySmart Grocer (ESG)

2.0 VISIT TO SITE. It was immediately evident entering the boiler house that there are several issues with the existing installation.

SCE170 SERVICE PARTS

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

F Series - Refrigeration dryers

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

RNC Series SCFM Global Air Treatment

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

JCseries EVAPORATIVE CONDENSER. engineering data

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

SIDE BY SIDE REFRIGERATOR MODELS: WRS325FDAW04 (White) WRS325FDAB04 (Black) WRS325FDAT04 (Biscuit) WRS325FDAM04 (Monochromatic Stainless)

Installation Instructions NEMA-3R Cover Kit for D1h D2h VLT FC Series FC 102, FC 103, FC 202, and FC Description. 1.

Repair Parts List REFRIGERATOR MODEL NUMBER GT15B83V. When requesting service or ordering parts, always provide the following information:

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

SIDE BY SIDE REFRIGERATOR MODELS: WRS325FDAW04 (White) WRS325FDAB04 (Black) WRS325FDAT04 (Biscuit) WRS325FDAM04 (Monochromatic Stainless)

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

25 CUBIC FOOT SIDE BY SIDE REFRIGERATOR MODELS: WRS325FDAW02 (White) WRS325FDAB02 (Black) WRS325FDAT02 (Biscuit) WRS325FDAM02 (Stainless)

SECTION REFRIGERANT PIPING

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

CABINET PARTS For Model: KBFC42FTS03 (Stainless Steel)

CABINET PARTS. For Models: KBLC36FMS00 (Stainless Steel) 9 05 Litho In U.S.A. (kdj) Part No " BOTTOM MOUNT BUILT IN REFRIGERATOR

CABINET PARTS For Model: KBLC36FMS02 (Stainless Steel)

The DC-3 is a revolutionary system which will redefine our industry with a plug and play solution for walk in/reach in cool rooms.

RNC Series SCFM Global Air Treatment

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Industrial Refrigeration Defrost Solutions TM Package. Brochure R-222

Accumulators - Suction Line

CMS1402 SERVICE PARTS

Pressure switch KPU. Data sheet

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

DTI Kenneth Bank Madsen Global Application Expert Food Retail

Menu operation via AKA 21 ADAP-KOOL. Controller for controlling evaporators AKC 114D, 115D and 116D. Software version 1.5x

TURBOIL (welded) / TURBOIL-F (flanged)

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

AIR COOLED CONDENSING UNIT

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Guide Specifications

Ammonia. Background on ammonia as a refrigerant

Condensing Unit Installation and Operating Instructions

VCBF136RSS3 : CABINET [1/9]

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

CABINET PARTS For Model: KBLC36FTS04 (Stainless Steel)

Transcription:

MAKING MODERN LIVING POSSIBLE Check valve for EVRA, EVRAT and PM valves in liquid lines type NRVS Technical brochure

Introduction NRVS NRVS mounted on PM and EVRA valve Check valve type NRVS has no damping feature and therefore can only be used for liquid line applications. NRVS is designed to be mounted directly to PM or solenoid valves EVRA/EVRAT. Features Ensures correct direction of flow Applicable to all common non flammable refrigerants including R717 and non corrosive gases/liquids dependent on sealing material compatability. Technical data Temperature of medium: 50 C +140 C Maximum working pressure PS = 28 bar/406 psig Materials Valve housing made of Stainless Steel Gaskets are non-asbestos 2 DKRCI.PD.FI0.A3.02 / 520H2617 Danfoss A/S (AC-AKC /frz), 07-2009

Capacities Location of valve in system (marked with grey) Hot gas by-pass & defrost line Low pressure liquid line Dry suction line Wet suction line Discharge line NRVS Liquid line without phase change Liquid line with or without phase change Valve combination EVRA/EVRAT 10 + NRVS 15 EVRA/EVRAT 15 + NRVS 15 EVRA/EVRAT 20 + NRVS 25 EVRA + NRVS 25 k v (m 3 /h) 1.4 2.2 4.1 7.0 Evaporating temperature T e 40 C 30 C 20 C 10 C Pressure p (bar) Capacities (kw) Q 0 at circulation rate 1 R717 0.15 172 270 504 960 0.25 222 349 650 1110 0.30 243 382 713 1216 0.40 281 441 823 1405 0.50 314 493 920 1570 0.15 167 262 489 835 0.25 215 338 631 1078 0.30 236 371 691 1180 0.40 273 428 798 1363 0.50 305 479 893 1524 0.15 161 254 473 808 0.25 208 327 610 1042 0.30 228 359 669 1142 0.40 264 414 772 1319 0.50 295 463 863 1475 0.15 156 245 456 780 0.25 201 316 589 1005 0.30 220 346 645 1102 0.40 254 399 745 1271 0.50 284 447 833 1422 Note: The capacities in the table must be divided by the actual circulation rate, or the evaporator capacities must be multiplied with the actual circulation rate. Solution 290 4 = 1160 kw EVRAT 25 + NRVS 25: Q 0 = 1180 kw, at p = 0.3 bar is chosen. Minimum opening differential pressure: EVRA/EVRAT 10-20 + NRVS EVRA/EVRAT 25 + NRVS 0.07 bar 0.11 bar Precise valve capacities can be calculated for various refrigerants by using the DIRcalc (Danfoss Industrial Refrigeration calculation programme). Example An application has the following operating conditions: Refrigerant:...R717 Evaporating temperature:... 30 C Evaporator capacity (Q 0 ):...290 kw Circulation rate:... 4 p 0.3 bar Danfoss A/S (AC-AKC/frz), 07-2009 DKRCI.PD.FI0.A3.02 / 520H2617 3

Capacities (continued) Location of valve in system (marked with grey) Low pressure liquid line Hot gas by-pass & defrost line Wet suction line Dry suction line Discharge line NRVS Liquid line without phase change Liquid line with or without phase change PM 15 PM 20 PM 25 Valve combination NRVS 25 NRVS 25 NRVS 25 k v (m 3 /h) 4.0 6.0 7.5 Evaporating temperature T e 50 C 40 C 30 C 20 C 10 C Pressure p (bar) Capacities (kw) Q 0 at circulation rate 1 R717 0.25 653 979 1224 0.30 715 1072 1340 0.40 825 1238 1547 0.50 923 1384 1730 0.25 635 951 1188 0.30 695 1043 1303 0.40 803 1204 1506 0.50 897 1346 1683 0.25 615 922 1152 0.30 675 1011 1265 0.40 779 1169 1460 0.50 871 1306 1632 0.25 595 894 1114 0.30 653 979 1224 0.40 753 1130 1412 0.50 852 1264 1580 0.25 575 862 1075 0.30 629 944 1180 0.40 727 1090 1362 0.50 812 1219 1523 Note: The capacities in the table must be divided by the actual circulation rate, or the evaporator capacities must be multiplied with the actual circulation rate. Minimum opening differential pressure: PM + NRVS will be fully open at p = 0.25 bar. Precise valve capacities can be calculated for various refrigerants by using the DIRcalc (Danfoss Industrial Refrigeration calculation programme). 4 DKRCI.PD.FI0.A3.02 / 520H2617 Danfoss A/S (AC-AKC /frz), 07-2009

Ordering Check valve Flanges, gasket and bolts 1 ) Valve type Code. no. For valve type Code no. Weight 2 ) [kg] Flange type Connection size NRVS 15 020-2032 EVRA/T 10, EVRA/T 15 027N1255 0.7 3 / 4 in. NRVS 25 020-2033 EVRA/T 20, EVRA/T 25, PM 15, PM 20, PM 25 027N1254 1.1 1 in. Flanges,gaskets and bolts for NRVS stand alone 3) Code no. Weight 2) [kg] Flange type Connection size 027N1256 0.256 3 / 4 in. 027N1257 0.443 1 in. 1) Consists of one standard and one special flange, one gasket and 2 bolts. 2) Flange and bolts only. 3) Consist of flanges, gaskets, bolts and nuts only. One standard flange and one special flange, two gasket, 2 bolts and 2 nuts. Dimensions and weights NRVS on valve NRVS stand alone Type L mm B mm Weight 1) kg NRVS 15 47.5 78.0 0.1 NRVS 25 60.5 96.0 0.25 1) NRVS without flanges and bolts Type L mm B mm Weight 1) kg NRVS 15 78 80 0.1 NRVS 25 98 96 0.25 1) NRVS without flanges and bolts Danfoss A/S (AC-AKC/frz), 07-2009 DKRCI.PD.FI0.A3.02 / 520H2617 5

6 DKRCI.PD.FI0.A3.02 / 520H2617 Danfoss A/S (AC-AKC /frz), 07-2009

Danfoss A/S (AC-AKC/frz), 07-2009 DKRCI.PD.FI0.A3.02 / 520H2617 7

8 DKRCI.PD.FI0.A3.02 / 520H2617 Danfoss A/S (AC-AKC /frz), 07-2009