Encyclon Inc. Cyclonic Filtration Systems

Similar documents
INSTALLATION INSTRUCTIONS

LC Series - Light Commercial Pump Station Installation and Operation Manual

OWNERS GUIDE TO INSTALLATION AND OPERATION

BLAST-IT-ALL BUMPER BLASTER

INTELLIGENT, HEALTHFUL LIVING

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

Room Air Conditioner Service and Parts Manual

690 and Power Fishing Systems

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

BLAST-IT-ALL PRESSURE BLAST CABINET

STAINLESS STEEL UNITS

Operation and Maintenance Manual 120V/60HZ

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Pump - Owner s Manual

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

TSS 15/55 Hi-Lift Vacuum

Manual for MC91 SETUP INSTRUCTIONS

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

Operation and Maintenance Manual 120V/60HZ

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

Manual for MC37/MFC3600

APW PSI PRESSURE WASHER

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Model K 240 plus Part No

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

This label warns for risk of electrical shock when failing to observe.

MODEL 7000 SUCTION UNIT

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

Model K205 M Plus Part No

690 Power Fishing System

Model K 330 M Part No

Model K 520 M Part No

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Model K 280 M Part No

CPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Manual update 2016 MC37/MFC3600

SimplyClear Pressurized Filter Product Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

K 3.97 M. Specifications or visit our website: In USA call: Part No

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

17 U.S. gallon portable low profile drain with electric pump

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Sanborn Technologies Catalog of Products

ASSEMBLY & OPERATING INSTRUCTIONS

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Two Tier Illumifalls Patio Pond

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

1700 PSI Electric Pressure Washer

SMF PUMP OWNER S MANUAL

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

Model K 3000 G Part No

SAND FILTER PUMP MANUAL

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX

SECTION 50 - CAB CLIMATE CONTROL

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

1600 Series Rotating Suction Screen

IMER USA (301) Koine 35 Quick User Guide IMER USA

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

INSTALLATION & OPERATING INSTRUCTIONS

Manual Centrifuges - Installation and Operation

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

English. Your Model Number is: HD1500 IMPORTANT

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

CAUTION UM120W (RIGHT TANK) FOR WATER BORNE PAINTS ONLY UM120W (RIGHT TANK) SECTION IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT

AllClear G2 Series Pressurized Filters Product Manual

OptiClean. U S E R S G U I D E 6 0 A 4 S E R I E S v. Product View. Assembly. Operations. Maintenance and Care.

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

Transcription:

Encyclon Inc. Cyclonic Filtration Systems INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR ENCYCLON FILTRATION SYSTEMS MODEL NO. 651SP-MWTT SERIAL NO. 20347 6705 14th Avenue PO Box 1258 Kenosha, WI 53143 P h o n e 8 0 0 / 7 6 7-3 5 5 1 2 6 2/ 6 54-0 0 3 2 F a x 2 6 2 /6 5 7-7 4 3 5 w w w. e n c y c l o n. c o m s a l e s @ e n c y c l o n. c o m

INDEX INDEX 1 PRE-TEXT & WARNINGS 2 DESCRIPTION OF THE FILTER SYSTEM 3-4 START-UP PROCEDURE 5 SYSTEM OPERATION 6 TROUBLESHOOTING & MAINTENANCE 7 FILTER CIRCUIT LAYOUT 8 REPAIR PARTS LIST & DRAWING 9-10 ELECTRICAL CONTROL HUBBELL BOOKLET FILTER PUMP- GUSHER BOOKLET CLEAN PUMP WEL-BILT BOOKLET PRESSURE WASH SECONDARY FILTER

PRE-TEXT & WARNINGS In order that this ENCYCLON filtration system may give continuous, satisfactory and safe service it is necessary that the filter be properly installed, operated and maintained. Please review this instruction book thoroughly before installation and operation of the filter. WARNINGS Caution is advised when installing this system. The hoses and piping should never be used for lifting purposes. The system should be plugged into a 120V / 1 / 60 Hz minimum 20 Amp GFCI receptacle. DO NOT service the system while in operation. DO NOT place hands in front of pump suction port while the system is running. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS PERSONAL SHOCK, INJURY OR DEATH. Page 2

ENCYCLON SYSTEM DESCRIPTION The ENCYCLON filtration system continuously cleans and filters wash water without using filter media to provide clean water for your application. The ENCYCLON hydrocyclone is the core of a continuous filtration system for water applications. The cyclone removes metallic and non-metallic particles as small as 5 microns with a specific gravity greater than 1.5. Through continuous filtration and aeration of the water by the cyclones, bacteria growth is retarded, thus preventing the water from becoming rancid. Page 3

Here s How Cyclonic Filtration Works Dirty liquid enters the cyclone at the inlet orifice (1) of the cyclonic chamber (3). The shape and tangential location of the orifice develop a downward, spiraling flow of the liquid. This is called the primary whirl (4) which follows the chamber walls downward, developing centrifugal force of up to 7500 times that of gravity. This same force spins out the solid particles to 5 microns, or.00019 diameter from the liquid. The solid particles (often referred to as swarf) strike the wall and slide down to the discharge orifice (7). A throttling effect in the lower cyclonic chamber (6) reverses the descent of the liquid but not the rotation. This forms the secondary whirl (5), a rising, spiraling flow of cleaned liquid that passes up through the primary whirl to the whirl searcher (2). The diameter of the whirl searcher is smaller than the secondary whirl, and the whirl searcher accepts only the center of the upward, secondary whirl flow. The outside portion of the secondary whirl (containing impurities missed by the primary whirl) is diverted back to the primary whirl for further cleansing. This double cleansing action is significant to the efficiency of the Encyclon Cyclonic Filtration Systems. Liquid that passes through the whirl searcher is then piped out to the clean water storage tank or can be directly used with 5 micron filtration with 98% efficiency. There are no filter media to clog or replace. Encyclon aerates water to check anaerobic bacterial growth. Page 4

START-UP PROCEDURE 1. Locate the ENCYCLON system as close as possible to the below grade sump. 2. Fill the Clean Tank (Front) first, then the Dirty Tank (Rear) and then the Swarf Container with clean water up to the overflow fittings. 3. Prime both pumps by removing the plugs on the impeller housings. Open 1-1/2 Ball Valve leading to the Cyclone Pump. Open 1 Ball Valve leading to the Clean Pump. DO NOT open 1 Ball valves attached to the drain of each tank as these are only used for drainage of the tanks. 4. Attach the supplied 1 hose to the 1 fitting on top of the Dirty Tank and the other end to the below grade Sump Pump supplied by others. 5. The Dirty Tank 2 overflow hose, and the 1-1/2 overflow hose from the Swarf Container should be directed towards the wash pad or below grade sump. 6. Make sure the ON / OFF rotary control for both pumps is in the OFF position. Plug shore cord into a minimum 120 Volt / 1 / 60 Hz, 20 Amp outlet. 7. Turn Cyclone Pump ON, Turn Clean Pump ON using the rotary switch. The Clean Pump has a separate ON/OFF rocker switch which is in the ON position from the factory. The Clean Pump will not function without the Cyclone pump running. 8. Connect pressure washer to hose bib and open valve. Page 5

SYSTEM OPERATION 1. Both tanks and the swarf container should be filled up to the overflow fittings. 2. Make sure the below grade sump is filled up to the height of the return from the wash pad. Connect the Sump Pump to the supplied 1 hose, and then connect the other end to the 1 fitting on top of the dirty tank. 3. Connect the power washer hose to the hose bib on the trailer and open the valve. 4. The ENCYCLON filter system is now ready to operate. During the wash operation, the ENCYCLON system should be run continuously and can be run after the wash operation is shut down if further filtration is desired or required. 5. Turn ON /OFF control to ON position for the Cyclone Pump. Inlet pressure to the cyclone should be 25 40 P.S.I. and the outlet pressure should be less than 10 P.S.I. 6. When mud appears on the surface of the swarf container, it must be emptied to prevent swarf from re-entering the below grade sump. 7. Keep water levels in all tanks up throughout the washing operation. 8. Cyclone Pump can run continuous as it is set up for closed loop operation, and the Clean Pump can run continuous as a pressure switch is used. 9. Make sure the Sump Pump does not send more liquid to the Dirty Tank than 20 GPM. This can be controlled with a ball valve on the Sump Pump. The Dirty Tank has an overflow to return excess water back to the sump. 10. The system will have a running water level of approximately 120 gallons in the Clean Tank and a running level in the Dirty Tank of approximately 110 gallons. The 2 overflow line should be directed back to the sump. 11. If the pressure washer is pulsing purge the secondary filter by opening the red valve for a few seconds to clear it. NOTE: Cyclone pump must be ON before the clean pump can be turned ON. Finally the pressure washer can be turned ON. Page 6

TROUBLESHOOTING & MAINTENANCE Normally the ENCYCLON system needs no maintenance. However, there are some things to watch for. Most problems can be detected by monitoring the pressure gauges mounted on the cyclone manifold assembly. 1. Low Cyclone In pressure below 25 P.S.I. gauge A. Disassemble and check for obstruction in suction line from the dirty tank to the pump. B. Disassemble and check for obstructions in pump casing and impeller. C. Disassemble and check for obstructions in pressure line. 2. High Cyclone Out pressure above 10 P.S.I. gauge A. Check for obstruction in the piping from the cyclone to the clean tank. B. Check for clogged cyclone assembly. 3. Clogging of nozzles A. Stop pump motor and unscrew the cap nut that secures the ceramic nozzle. B. The cleaning of the nozzle and the conical part of the cyclone is done with a wire of about 1/8 inch in diameter rounded off at the end, so that there is no damage done to the inside cone surface. C. Reassemble nozzle after cleaning by reversing above step. 4. Clean pump surging A. Purge the secondary filter by opening the red valve while the clean pump is running for a few seconds to clear the filter. Page 7

Page 8

RECOMMENDED REPAIR PARTS When ordering repair parts the following should be given to assure delivery of proper parts for your filter system. 1. Model No.: 2. Serial No.: 3. Part No.: 4. Quantity: 5. Description: 6. Send Order To: Encyclon, Inc. 6705 14 th Avenue Kenosha, WI 5314 800-767-3551 262-657-7435 Fax Part No. Qty. Description Page 650-023 1 Pressure Gauge 0-30 N/A 650-024 1 Pressure Gauge 0-60 N/A 274-125 1 90 degree Hose 10 200-002 4 Hose Clamp 10 601-001 1 Inlet Nozzle 10 957-003 1 2-1/2 O Ring 10 602-001 1 Cone Shaped Casing 10 957-002 1 1 O Ring 10 603-001 1 Cap Nut 10 604-001 1 Ceramic Nozzle 10 605-001 1 Spray Protector 10 282-125 1 Straight Hose 10 800-117 1 Filter Pump / Gusher 2 H.P. N/A RH30425 1 Pump Mechanical Seal N/A 61051-EPDM 1 Pump Housing Gasket N/A 800-123 1 Clean Pump WEL-BILT N/A Page 9