Rosemount High Density Temperature Measurement Simplify Your Project
848 Balancing Project Risk is a Daunting Challenge Emerson s approach to temperature measurement can help lower the risk of budget overruns and start-up delays. Rosemount High Density transmitters reduce installation complexities, lower costs and simplify your project. 100% 75% 50% 25% T o t a l I n s t a l l a t i o n C o s t s Documentation Labor Materials 0% Conventional Temperature Products High Density Temperature Transmitters Reduce Cost with Less Wiring Wiring infrastructure such as conduit, cable trays and marshalling panels add significant cost to a project. Rosemount High Density transmitters measure multiple temperatures to reduce or eliminate wiring infrastructure and provide significant cost savings.
Traditional Transmitters TT TT TT TT High Density Transmitter Faster Start-ups with Fewer Devices Installing wiring runs for each temperature measurement is labor intensive and costly. Rosemount High Density transmitters measure more temperature points with fewer devices to reduce installation and commissioning time. Sensors to I/O Card Temperature Drift 2 C 0 C 848T Time Rosemount 848T Temperature Transmitter with Multipoint Sensor Improve Performance with Reliable Measurement Reduce Complexity with Complete Solutions Long sensor wiring runs are susceptible to drift giving unreliable information. Rosemount High Density transmitters shorten sensor wiring lengths and filter electrical noise to provide stable and accurate measurement. Managing multiple temperature vendors for a project adds complexity. Emerson manufactures transmitters and sensors globally to meet your project needs.
Implementation Made Easy Rosemount High Density transmitters simplify installation to reduce overall cost and labor effort. Scalable Architecture Add new devices to existing networks Hundreds of temperature measurements on one network Easy Access to Device Information Eliminate Individual Signal Wires Communicate with single 2-wire loop Connect without marshalling panels FOUNDATION fieldbus Evaluate, diagnose, and configure with Device Dashboards Access transmitter and sensor diagnostics Smart Wireless Gateway
Rosemount 848T Wireless Temperature Transmitter WirelessHART Network Eliminate Signal Wire Simplify installation without cable trays Install without junction boxes Connect without marshalling panels 4 Independently configurable inputs Thermocouple, RTD, ohm, mv, and 4-20 ma inputs Mounts anywhere with field hardened enclosure Intrinsically safe Power Module for easy replacement in hazardous areas Uses standard HART configuration tools to integrate into WirelessHART network Up to 400 measurements on a single Smart Wireless Gateway Mount Close to Process Shorten sensor wires to improve measurement reliability Field hardened enclosures for harsh environments Rosemount 848T Temperature Transmitter 8 Independently configurable inputs Thermocouple, RTD, ohm, mv, and 4-20 ma inputs DIN rail mounting for flexible installation practices Calculates minimum, maximum and average Up to 128 measurements on one FOUNDATION fieldbus segment
Deliver Results with Innovative Solutions From preventing unexpected shutdowns to reducing installation costs, Rosemount High Density transmitters have proven to deliver positive business results. Our customers have simplified their projects by installing Rosemount 848T temperature transmitters in their plant. Tank Temperature Measure Tank Temperature to Improve Product Quality Challenge: Maintaining tank temperature was difficult Existing measurement wired thermocouples directly to control room Drifting measurement increased risk of producing off-spec product Solution: Rosemount 848T Wireless reduced sensor wiring and eliminated drift Product quality was improved and installation costs were reduced by $5,500 per point Improve Reactor Control to Prevent Shutdown Challenge: Control of reactor during polymerization process was needed to ensure product quality Sensor wired directly to control room incurred high material and labor costs Reactor could become plugged causing a two to three week shutdown Solution: Rosemount 848T profiled 16 temperature points in reactor dome Detected a polymer buildup and prevented a costly shutdown Reactor Temperature Profiling
Prevent Compressor Failure by Monitoring Bearing Temperature Challenge: Monitoring bearing temperature to prevent gas compressor failure Local temperature monitoring did not report information to control system Gas compressor failure would cause shutdown of hydrocracker Solution: Rosemount 848T detected damage to the bearing preventing a hydrocracker shutdown Saved over 70% in wiring cost amounting to $20,000 Bearing Temperature Coke Oven Temperature Monitor Oven Temperature to Reduce Operation Costs Challenge: Difficulties monitoring and controlling coke oven temperatures Existing measurement was unreliable and operator rounds were costly Unreliable measurement risked oven collapse and energy waste Solution: Rosemount 848T Wireless provided reliable measurement ensuring proper oven temperature Eliminated operator rounds and provided access to process information To experience the Rosemount 848T visit www.rosemount.com/848t
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of the Emerson Process Management group of companies. All other marks are the property of their respective owners. 2010 Rosemount Inc. All rights reserved. Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 949 7001 Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland Tel +41 (0) 41 768 6111 Fax +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE Tel +971 4 811 8100 Fax +971 4 886 5465 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 Tel +65 6777 8211 Fax +65 6777 0947 Service Support Hotline : +65 6770 8711 Email : Enquiries@AP.EmersonProcess.com 00803-0100-4697 Rev AA, 02/10