DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS REVOLUTION L-360-CD & L-420-CD SERIES If for any reason, you cannot follow these instructions, FOR ANY REASON WHATSOEVER, just return the product to your dealer, and the dealer will refund your money. PLEASE do not use this product if you cannot follow these instructions. GENERAL INFORMATION BEFORE YOU BEGIN! READ THE HEARTH KIT INSTRUCTION MANUAL, FURNISHED WITH THE APPLIANCE. FOLLOW ALL SAFETY AND SET UP PROCEDURES! These instructions are intended as a general guide and do not supersede national or local codes in any way. State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes. Authorities having jurisdiction should be consulted before installation.!!! IMPORTANT!!! Read these instructions carefully before installing or operating this gas appliance. These instructions should be left with the homeowner for future reference. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.!!! WARNING!!! If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 15LP ANSI Z21.11.2 (2002) STANDARD FOR GAS-FIRED UNVENTED ROOM HEATERS (US ONLY) & ANSI Z21.60 - (2003) / CGA 2.26 - (2003) STANDARD FOR DECORATIVE GAS APPLIANCES FOR INSTALLATION IN SOLID-FUEL BURNING FIREPLACES (US & CANADA). 15LP!!! WARNING!!! Failure to position the parts in accordance with all included pictures, diagrams, and drawings, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. DO NOT apply any extra material or gas logs not furnished with this appliance.!!! WARNING!!! The position of the gas logs is critical to the safe and clean operation of this appliance. Sooting and other problems may result if the gas logs are not properly, and firmly positioned on the appliance.!!! IMPORTANT!!! This appliance is supplied with nine ( 9 ) decorative gas logs. Handle all gas logs with care and, it is our recommendation that you use gloves during the set up procedures. 1
L-360-CD & L-420-CD DECORATIVE GAS LOG SERIES INDIVIDUAL LOGS LOG # IFG-2401-CD LOG # IFG-2405-CD LOG # IFG-2406-CD LOG # IFG-2402-CD OR # IFG-3002-CD LOG # IFG-2407-CD LOG # IFG-2403-CD OR # IFG-3003-CD LOG # IFG-2408-CD LOG # IFG-2404-CD LOG # IFG-2409-CD L-360-CD & L-420-CD DECORATIVE GAS LOG SERIES ACCESSORY ADD LOGS FG-HAK ACCESSORY ADD LOGS FG-LAK ACCESSORY ADD LOGS 2
FG-HAK DECORATIVE GAS LOG ACCESSORY INDIVIDUAL ADD LOGS FG-LAK DECORATIVE GAS LOG ACCESSORY INDIVIDUAL ADD LOGS HAK-01 LAK-01 LAK-02 HAK-02 HAK-03 LAK-03 LAK-04 HAK-04 3
L-360-CD SERIES SHOWN WITH ACCESSORY ADD LOGS L-360-CD SERIES SHOWN WITH FG-HAK ADD LOGS L-360-CD SERIES SHOWN WITH FG-LAK ADD LOGS!!!WARNING!!! FG-LAK & FG-HAK add logs, may be placed anywhere within the fireplace enclosure, EXCEPT DIRECTLY IN THE FIRE. DO NOT PLACE THE ADD LOGS DIRECTLY IN THE FIRE! 4
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD 1- Place Log # IFG-2401-CD, along the left side of the grate/burner assembly, making sure to index the bottom of the log, along the grate tine. 5
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 2- Place Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ) along the rear of the grate/burner assembly, making sure to index the locator on Log # IFG-2401-CD, and the grate tine, on the right rear of the appliance. 6
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 3- Place Log # IFG-2404-CD on the front right side of the grate/burner assembly, making sure to index the front, right two ( 2 ) grate tines, and the valve mounting bracket. 7
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 4- Place Log # IFG-2403-CD ( Log # IFG-3003-CD for 420 series ) diagonally across the center of the set, making sure to index the locator on Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ), and the top of the grate leg and tine on the front left of the appliance. 8
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 5- Place Log # IFG-2406-CD on the top right side of Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ) and Log # IFG- 2404-CD, making sure to index the log, to the locators on the two ( 2 ) base logs. 9
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 6- Place Log # IFG-2405-CD across the center of the set, making sure to index the locators on rear Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ), center crossing Log # IFG-2403-CD ( Log # IFG-3003-CD for 420 series ), and the tip of front right Log # IFG-2404-CD. 10
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 7- Place Log # IFG-2409-CD on the top left side of the set, making sure to index the far left grate tine, and the top of rear Log # IFG-2402-CD ( Log # IFG-3002-CD for 420 series ). 11
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 8- Place Log # IFG-2407-CD along the front, lower, left side of the burner, making sure to index the rear of the log, to the corner of the burner. 12
PROPER INSTALLATION SEQUENCE: L-360-CD & L-420-CD continued 9- Place Log # IFG-2408-CD along the front, lower, right side of the burner, making sure to index the rear of the log, to the corner of the burner. 13
FIREGEAR L-360-CD & L-420-CD SERIES PARTS LIST Attention: When ordering Parts, it is important that you have the correct part number and description. COMMON PART L-360-CD - Bottom Left Log L-360-CD - Back Log L-360-CD - Crossover Log L-360-CD - Front Right Log L-360-CD - Top Center Log L-360-CD - Top Right Log L-360-CD - Left Ember Twig L-360-CD - Right Ember Twig L-360-CD - Top Left Log L-420-CD - Bottom Left Log L-420-CD - Back Log L-420-CD - Crossover Log L-420-CD - Front Right Log L-420-CD - Top Center Log L-420-CD - Top Right Log L-420-CD - Left Ember Twig L-420-CD - Right Ember Twig L-420-CD - Top Left Log PART NUMBER IFG-2401-CD IFG-2402-CD IFG-2403-CD IFG-2404-CD IFG-2405-CD IFG-2406-CD IFG-2407-CD IFG-2408-CD IFG-2409-CD IFG-2401-CD IFG-3002-CD IFG-3003-CD IFG-2404-CD IFG-2405-CD IFG-2406-CD IFG-2407-CD IFG-2408-CD IFG-2409-CD FG-LAK - ADD LOGS FG-LAK - Log One FG-LAK - Log Two FG-LAK - Log Three FG-LAK - Log Four LAK-01 LAK-02 LAK-03 LAK-04 FG-HAK - ADD LOGS FG-HAK - Log One FG-HAK - Log Two FG-HAK - Log Three FG-HAK - Log Four HAK-01 HAK-02 HAK-03 HAK-04 HOW TO ORDER REPAIR PARTS Parts may be ordered only, through your service person or dealer. For the best results, the service person or dealer should order parts through the distributor. Parts may be shipped directly to the service person/dealer. All parts listed in the PARTS LIST have individual PART NUMBERS and descriptions. When ordering parts, first obtain the Model Number from the name plate on your equipment; then determine the PART NUMBER (not the Index Number) and the part description of each part from the parts list. Be sure to include all of this information. Appliance/Heater Model Number Type of Gas: NG LP Appliance/Heater Serial Number Part Description Part Number DO NOT order bolts, screws, washers or nuts. These are standard hardware items that may be purchased at any local hardware store. Shipments are contingent upon strikes, fires, and any circumstance, beyond the control of firegear. firegear LLC Attention: Customer Service Department 38236 Abruzzi Dr. Westland, MI 48185 Telephone: 734-595-3550 Fax: 734-595-3512 14
This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, vandalism, improper installation or improper maintenance or service, or failure to perform normal and routine maintenance. Deterioration, discoloration due to heat, or damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due to exposure to chemicals ( including salt ), either directly or in the atmosphere, or very high humidity, is not covered by this Limited Warranty. LIMITED WARRANTY firegear hereby warrants to the ORIGINAL PURCHASER of this firegear Decorative Gas Log Set, that it will be free from defects in material and workmanship from the date of purchase as follows: Refractory Gas Logs Revolution Burner Grate 5 years 2 years 5 years All other parts ( safety pilots, valves, regulator, etc ), are warranted by the original manufacturer. When assembled and operated in accordance with the accompanying printed instructions. firegear may require reasonable proof of your date of purchase. YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE AND RETURN THE WARRANTY REGISTRATION CARD WITHIN 10 DAYS OF PURCHASE. This Limited Warranty shall be valid and limited to, the original purchaser only, within the confines of the original site installation. WARNING: Any modification to this heater or its controls will void the warranty! There are no other express warranties except as set forth herein and any applicable implied warranties of merchantability and fitness are limited in duration to the period of coverage of this express written Limited Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you. firegear is not liable for any special, indirect or consequential damages. firegear s liability is limited to the purchase price of this firegear Decorative Gas Log Set. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you. firegear does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such representations are binding on firegear. This Warranty applies only to products sold at retail and manufactured by: firegear, LLC 38236 Abruzzi Dr. Westland, MI 48185 734-595-3550 734-595-3512 fax website www.firegearusa.com This Limited Warranty shall be limited to the repair and/or replacement of parts that prove defective under normal use and service and which on examination shall indicate, to firegear s satisfaction, that they are defective. Before returning any parts, contact firegear Customer Service Center. If firegear confirms the defect and approves the claim, firegear will replace such parts without charge. If you are required to return defective parts, transportation charges must be prepaid. firegear will return parts to the purchaser, freight or postage prepaid. 15
www.firegearusa.com L360CD420CD 3.1 16