Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Similar documents
Installation Instructions for the 600 Series Optical Encoders

V-Basic Standard V15 Series

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Installation Instructions for the

MICRO SWITCH NT Series

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

MICRO SWITCH BAF/DTF Series

MICRO SWITCH NT Series

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

MICRO SWITCH GSX Series

MICRO SWITCH GLL Series

MICRO SWITCH E6/V6 Series

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Intrinsically Safe Transmitters, Option Code 2n

Wireless Panel-Mount Monitor

Installation Instructions for the

HIH-4000 Series Humidity Sensors

Quadrature Speed and Direction Sensors

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

HIH-4602-L Series Humidity Sensors

HFX Fiber Optic Component 50 Mbps, 650 nm LED

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

HIH-5030/5031 Series Low Voltage Humidity Sensors

MICRO SWITCH V15W Series Watertight Miniature Switches

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

General Purpose Industrial VRS Magnetic Speed Sensors

Micropower Omnipolar Digital Hall-Effect Sensor ICs

HOA6480 Series Barcode Sensor Infrared Products

High Temperature Industrial VRS Magnetic Speed Sensors

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

FEATURES AND BENEFITS

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

FSS-SMT Series. Low Profile Force Sensor

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

Potential Applications

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

MICRO SWITCH BX/BX2 Series

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet


Sensors and Switches in Commercial Traction Elevators

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Guide to Hazardous Location Approvals:

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MICRO SWITCH Cable-Pull Safety Switches CPS Series Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS

Linear Current Sensors

LCZ Series Hall-effect Zero Speed Sensors

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

WARNING MISUSE OF DOCUMENTATION

Fiber Optics and Liquid Level Sensors Line Guide

Sensor Evaluation Kit, SEK001

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HIH-4030/31 Series Humidity Sensors

Interactive Catalog Replaces Catalog Pages

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Wireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series)

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MICRO SWITCH Basic Switches Line Guide

HIH-4602 A & C Series.

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

SVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HIH-4010/4020/4021 Series Humidity Sensors

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

TruStability Board Mount Pressure Sensors

AMR 4-Pin Quadrature Sensor Integrated Circuit

Transcription:

Installation Instructions for the LM Series MCU (Microcontroller Unit) Issue 3 50082092, CAUTION Be cautious when working around and connecting to the LM Series terminals, especially those other than the positive terminal (+) as there is no electrical protection on the negative (-), reset, enable, and/or backlight terminals. INSTALLATION For specific model instructions, see steps below for model-specific processes and Figure 8 for visual aids. Diamond Shape with Bezel Mounting Process (LM-HH*) 1. Panel cut based on required mounting hole. 2. Insert product into mounting hole. 3. Insert screws into the two mounting holes. 4. From backside, fix washers and nuts on screws. 5. Torque nuts to 5 in-lb to secure hour meter to panel. WIRING INSTRUCTIONS Included with the LM Series hour meters are 16 ga, black PVC covered per GM spec 59072-R terminals wires (Honeywell part number 4685) (See Figure 4). The quantity of wires included with the LM Series hour meter is identical to the number of active terminals on the hour meter (either 2, 3, or 4). An equivalent wire may also be used. If the hour meter is mis-wired, no product damage will occur under any mis-wired condition. FIGURE 1. WIRING DIAGRAM Standard Shape Mounting Process (LM-HS*) 1. Panel cut based on required mounting hole. 2. Insert product into mounting hole. 3. From backside, push retainer into panel. Round with Bezel Shape Mounting Process (LM-HB* and LM-HW*) 1. Panel cut based on required mounting hole. 2. Insert product into mounting hole. 3. From backside, push cup retainer into the panel. 4. Torque nuts to 5 in-lb to secure hour meter to panel. Rectangle Shape Mounting Process (LM-HC*) 1. Panel cut based on required mounting hole. 2. Insert product into mounting hole. 3. From backside, push bracket into the panel. 4. From the backside, fix washers and nuts on screws. 5. Torque nuts to 5 in-lb to secure hour meter to panel. Diamond Shape with No Bezel Mounting Process (LM-HD*) 1. Panel cut based on required mounting hole 2. Insert product into mounting hole 3. Insert screws into the two mounting holes. 4. From backside, fix washers and nuts on screws. 5. Torque nuts to 5 in-lb to secure hour meter to panel. Pin + Pin - Pin E Pin R/B V+ operating voltage V - common (ground) Enable (use operating voltage to power this pin to record elapsed time) Backlight or reset to zero ACTIVATION Two-terminal hour meters will always record time once power has been applied. For LM Series hour meters with three or four active terminals, enable power on by the positive contact and the device will continuously record. Hour meters with four terminals will become backlit once the backlight terminal connects to positive contact. RESETTING THE DEVICE To reset the Honeywell s LM Series hour meter s digits to zero, connect the R terminal to positive. This action should be applied for at least one second to avoid mis-operation. Sensing and Control

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 PERFORMANCE SPECIFICATIONS Characteristic Digital range Digital height Backlight color View angle Running indicator Accuracy Operating voltage range Sealing Shock Vibration Measure 0 to 99,999.9 hours 7 mm Blue (default); other options available 12 o clock Yes ±200 ppm/hour 9 V to 64 V dc/ac (50 Hz to 500 Hz) IP67 (front); IP66 (rear) 55 g per SAE J1378 75 g per MIL-M-3917D 20 g per SAE J1378 10 g per MIL-M-3917D Humidity 95 % non-condensing at 38 C Operating temperature Storage temperature Transient immunity Power consumption Panel mounting Case sealing technique front Case sealing technique rear Start time Material case Material lens Case depth Termination -40 C to 85 C [-40 F to 185 F] -50 C to 90 C [-58 F to 190 F] Load dump yes Inductive yes EMI yes Reverse polarity yes 0.8 ma @ 12 Vdc Snap-in Ultrasonic weld Sealant on terminals <1 s; if including all 8 check, then >1 s Makroblend Lexan 1.35 in (including terminals) 1/4 in blades; 3/16 in blades 2 Honeywell Sensing and Control

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 FIGURE 2. LM SERIES DIAMOND-SHAPED DIMENSIONS AND MOUNTING (LM-HH*) 1.755 in 1.745 in 1.455 in 1.445 in #6-32 X.50 -REF ROUND HEAD MACHINE SCREW CLASS 2 THREAD #6 INTERNAL SHAKEPROOF TYPE 12 #6-32 NC2B THREADS NUT 2X Ø 0.150 in ±0.005 in HOLES 0.955 in 0.945 in 0.480 in 0.470 in MOUNTING HOLES R 0.030 in ±0.005 typ. LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER, PRODUCING AREA SHOULD BE PRINTED ON LABEL. LENS: BACKGROUND BLACK WITH WHITE LETTERING 2.13 in 1.75 in 0.957 in LOGO 0.08 in 1.35 in 0.79 in 0.75 in 0.14 in 0.22 in ±0.02 in 10 1.25 in (0.33 in) (0.89 in) 0.18 in 2X Ø 0.15 in BENDING TERMINAL (OPTIONAL,CUSTOMER DEFINE) (1.41 in) CASE TERMINAL TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT. Honeywell Sensing and Control 3

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 FIGURE 3. LM SERIES STANDARD-SHAPED DIMENSIONS AND MOUNTING (LM-HS*) RETAINER 1.455 in 1.445 in 4X R 0.030 in ±0.005 in 0.955 in 0.945 in MOUNTING HOLE LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER, PRODUCING AREA SHOULD BE PRINTED ON LABEL. 1.79 in 1.60 in (0.957 in) 0.10 in 0.79 in 0.75 in 0.22 in ±0.02 in 10 1.44 in max. 0.88 in (0.44 in) (0.18 in) 1.08 in (0.330 in) 0.94 in max. 0.36 in BENDING TERMINAL (OPTIONAL, CUSTOMER DEFINE) TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT. STANDARD GEOMETRY FIGURE 4. LM SERIES TERMINAL CONNECTOR WIRE (Honeywell Part number: 4685) Terminal/connector 16 Ga. wire, black, PVC covered per GM spec 59072-R 4 Honeywell Sensing and Control

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 FIGURE 5. LM SERIES ROUND-SHAPED DIMENSIONS AND MOUNTING (LM-HB* and LM-HW*) Ø 2.00 in 0.12 in 0.30 in 1.33 in 0.98 in 0.73 in CUP RETAINER & HEX NUT & LOCKWASHER 1.44 in max. LOGO Ø 2.27 in (0.18 in) Ø 2.41 in 0.94 in max. BEZEL DIAL CASE 0.88 in (0.44 in) LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER, PRODUCING AREA SHOULD BE PRINTED ON LABEL. TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT 2.00 in ±0.005 in MOUNTING HOLE Honeywell Sensing and Control 5

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 FIGURE 6. LM SERIES RECTANGLE-SHAPED DIMENSIONS AND MOUNTING (LM-HC*) BRACKET (50067657-001) NUT (50067656-001) LOCK WASHER (50067695-001) 1.902 in 1.291 in 1.768 in 0.957 in 0.87 in 0.157 in 0.72 in LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER, PRODUCING AREA SHOULD BE PRINTED ON LABEL. 1.77 in 0.88 in R 0.047 MOUNTING HOLE RECTANGLE GEOMETRY 6 Honeywell Sensing and Control

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 FIGURE 7. LM SERIES DIAMOND-SHAPED (NO BEZEL) DIMENSIONS AND MOUNTING (LM-HD*) #6-32 X.50 -REF ROUND HEAD MACHINE SCREW CLASS 2 THREAD #6 INTERNAL SHAKEPROOF TYPE 12 #6-32 NC2B THREADS NUT OPTIONAL DELUXE BEZEL (GASKET FLANGE) 4X R 0.03 0.95 in 0.48 in 2 X Ø 0.150 in holes 1.45 in 1.75 in MOUNTING HOLES LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER,PRODUCING AREA SHOULD BE PRINTED ON LABEL. BACKGROUND BLACK WITH WHITE LETTERING 2.05 in 1.75 in (0.957 in) 1.35 in 0.79 in 1.44 in max. 0.75 in (0.88 in) 0.22 in 0.10 in ±0.02 in (0.44 in) 10 0.18 in 1.03 in (0.330 in) TERMINAL 0.94 in max. BENDING TERMINAL (OPTIONAL, CUSTOMER DEFINE) 2 X Ø 0.150 in holes CASE- BLACK TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT Honeywell Sensing and Control 7

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 FIGURE 8. LM SERIES MOUNTING 8 Honeywell Sensing and Control

LM Series MCU (Microcontroller Unit) ISSUE 3 50082092 WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: sensing.honeywell.com Phone and Fax: USA/Canada +1-800-537-6945 International +1-815-235-6847; +1-815-235-6545 Fax PERSONAL INJURY WARNING DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 50082092-3-EN IL50 GLO September 2013 2013 Honeywell International Inc. All rights reserved.