Guide to: 17 th Edition Consumer Units

Similar documents
Guide to sollysta Wiring Accessories

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Consumer Units for Domestic Household (and other) Premises. Amendment No. 3 BS 7671

Consumer unit replacement in domestic and similar premises

Amendment 3 Metal Cased Skeleton Consumer units for use in Meter Cabinets. Starbreaker

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Bringing power to life. TECHNICAL BULLETIN RESIDUAL CURRENT DEVICE (RCD) SELECTION

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

Requirements for Electrical Installations

Periodic inspection reporting - recommendation codes for domestic and similar electrical installations

BS Outcomes 6

An overview of the main proposals in BS th Edition. Electrical Contractors Association

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Welcome to Hager Presentation

Bringing power to life. GUIDE TO ARC FAULT DETECTION DEVICES (AFDD)

Special Types of Installation

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

Intumescents & Accessories for use in Consumer Units for Domestic Household and other Premises. Amendment No. 3 BS 7671

INTERNATIONAL STANDARD

NMFS Intumescents & Accessories for use in Consumer Units for Domestic Household Premises. Amendment No. 3 BS 7671

Information Sheet LIA IS 07 Issue 1 08/2013 Page 1 of 5 For LIA members use only

Arc Fault Detection Devices. 18th Edition - We re ready

Requirements for Electrical Installations

dhf General Information Automated Gates Guidance for enforcement bodies

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

Mains Power Filter 970MF10 970MF20. Installation Instructions

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

User Information Sheet 008 : 2010

Guide to Amendment 3. Innovators - Developers - Manufacturers Passive Fire Prevention Products

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

Guide to Condition Reports for Domestic Electrical Installations

Amendment Number 3 of BS how it might affect you

INTERNATIONAL STANDARD

Guide to condition reports for domestic electrical installations.

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AS/NZS 3190:2011 AS/NZS

INTERNATIONAL STANDARD

A guide. Part 1: Code of practice for system design, installation, commissioning and maintenance. by T.L. Journeaux

A BITESIZED GUIDE TO AFDDs AND FIRE PROTECTION

Designed & Manufactured by... A Guide to RCDs & Electrical Safety....Anything else is a compromise

SCHEDULE OF RATES SHEET PRELIMINARIES

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Ultra cold freezer storage. Risk management guide for research materials

emat Pro 100/150/200 Installation Manual

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Neil Hewitt Electrical & Air Conditioning P/L

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Managing Ex Asset Integrity

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

INSTALL AN ELECTRIC SHOWER

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

T THATCHED BUILDINGS Electrical installations in. 1 of 5. Introduction. Consultation. Assessment of general characteristics

Fire Risk Assessment

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

For use with approved Bathstore head kits. Installation guide. Viso Digital installation instructions Page 1

National Electrical Code

TAITA TAVETA UNIVERSITY P.O.BOX , VOI, KENYA Tel: TENDER NO: TTU/T/01A/

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Electrisaver User and Installation Instructions

LoadCentre KQ Distribution boards

SANS :2012 Edition 1.8

Protect Safety Alarms

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

2.8KW ELECTRIC FAN HEATER

Lighting & Controls Motion & Presence Detectors

Telecity. Table of Contents. Page. Section 3.2

MEDIUM-DENSITY HOUSING # 7. Fire safety

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CHAPTER 5 - STRUCTURAL FIRE PRECAUTIONS

Complete the table to show which size fuse, 3 A or 13 A, should be fitted to each of the appliances. Appliance Power Fuse

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

RE-PR3-E-27 3-Phase Panel Mount 27kW

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

WELSH GOVERNMENT DOMESTIC FIRE SPRINKLER PILOT STUDY. Colin Blick Building Standards Technical Manager Welsh Government

Lloyd s Register Type Approval System Test Specification Number 3

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

3KW ELECTRIC FAN HEATER

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Fire precautions in dwellings

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

Transcription:

Guide to: 17 th Edition Consumer Units

Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are safe. The introduction of the 17 th Edition of the Wiring Regulations and subsequent amendments have had major implications for all Electrical Contractors, Designers and Consultants. Several regulations have an impact upon circuit design, consumer unit layout and even the construction of the consumer unit itself. This guide will help you understand the new Wiring Regulations and current Building Regulations, providing the necessary facts to construct compliant installations including Consumer Units. If after reading this guide you would like to find out further information regarding the new regulations Hager offer tailored training courses. If you are interested in registering interest in attending one of these courses please visit www.hager.co.uk 2 Guide to 17 th Edition Consumer Units

Contents Building Regulations Page 5 Requirements of the 17 th Edition Wiring Regulations Page 6 Socket Outlets Page 9 Cables Buried in the Wall Page 10 Special locations Page 12 Other Considerations Page 14 Fire Detection and Alarm Systems for Buildings Page 16 Consumer Unit Arangements Page 18 Conclusions and Training Courses Page 24 Residual Current Devices Used in Consumer Units Page 25 While the author believes that the information and guidance given in this document is correct, all parties must rely upon their own skill and judgement when making use of it. The author does not assume any liability to anyone for loss or damage caused by any error or omission in the work, whether such error or omission is the result of negligence or any other cause. Any and all such liability is disclaimed. Guide to 17th Edition Consumer Units 3

4 Guide to 17 th Edition Consumer Units

Building Regulations Since 2005 the Building regulations for England and Wales have made direct reference to electrical installations, increasing the influence on how electrical equipment is installed in buildings. Consumer Units may need to be easily reachable and be mounted with the devices at a height of between 1350mm & 1450mm above floor level Part P of the building regulations relates to the electrical safety in dwellings. The approved document prescribes that switches, sockets and consumer units in new dwellings should be easy to reach, in accordance with Part M of the building regulations. Approved Document M recommends that in new dwellings, switches, sockets and other equipment should be located between 450mm and 1200mm from finished floor level, it also suggests that consumer units are mounted so that the switches are between 1350mm and 1450mm above floor level. Height of between 1350mm and 1450mm from floor level In the case of multi-row consumer units, the bottom row of switches should be between 1350 and 1450mm so that they are out of reach of young children. Depending on the layout of the dwelling and position of the consumer unit, a flush consumer unit may be considered. Guide to 17th Edition Consumer Units 5

Requirements of 17 th Edition Wiring Regulations inc. Amd 3 The third amendment to BS 7671 :2008 has introduced a requirement for enhanced functionality of the consumer unit. The Regulation states: 421.1.201 Within domestic (household) premises, consumer units and similar switchgear assemblies shall comply with BS EN 61439-3 and shall: 1. Have their enclosures manufactured from non-combustible material, or 2. Be enclosed in a cabinet or enclosure constructed of noncombustible material and complying with Regulation 132.12. Note 1: Ferrous metal e.g. steel, is deemed to be an example of a non-combustible material. Note 2:The implementation date for this regulation is the 1st January 2016, but does not preclude compliance with the regulation prior to this date The intent of this regulation is considered to be, as far as is reasonably practicable, to contain any fire which may have started, mainly as a result of poorly installed connections within the enclosure, and to minimise flames from escaping. The enclosure is considered to be the entire unit which includes the base, cover and the door or lid. All the devices and blanks must be contained within this non-combustible enclosure. Base The consumer unit enclosure should be made of non-combustible material Door Cover 6 Guide to 17 th Edition Consumer Units

The installer would of course require access to this enclosure for cable entry. It is important that any holes made for cable entry are no larger than they need be. The cable installation entry method shall, as far as is reasonably practicable, maintain the fire containment of the enclosure. It is essential that account is taken of the manufacturer s instructions, if any. This can generally be achieved by the installer ensuring that cable access holes they make in the enclosure do not to leave gaps greater than: 1.0 mm for the horizontal top surface and 2.5 mm for all other surfaces of the enclosure that are accessible after installation. The installer could for example, select as they deem appropriate; trunking, conduit, cable gland or cable entry accessories to minimise the opening around the cables. For rear cable access, the minimum number of rear knockout(s) shall be removed to accommodate the cable(s). There is no specific requirement in regulation 421.1.201 for fire-rated cable glands or intumescent sealant to be used however, this does not preclude the installer using these or other methods, should they be considered necessary. 2.5mm 1mm 2.5mm 2.5mm 1mm Openings around cable entry should be minimized, use of trunking is one option Guide to 17th Edition Consumer Units 7

Other Enclosures As previously stated, regulation 421.1.201 includes for consumer units AND similar switchgear. In a larger dwelling there may be a requirement for a 3 phase supply. The distribution board in this instance would be required to meet the same non-combustibility requirements as a single phase consumer unit. It is important the specifier obtains information from the manufacturer of the 3 phase TP&N enclosure that this requirement is satisfied. It may not simply be the case of using a TP&N enclosure which is normally used in commercial applications as there may be some plastic components which will not meet the non-combustable criteria. Likewise this could include for:- Enclosures for building automation systems such as KNX devices One way consumer units (a double pole main switch and one outgoing way) Shower Units Garage Units Distribution Boards (with circuit breakers or fuses) Photo-voltaic combiner boxes Voltage optimisation units TP&N enclosures and other similar switchgear will also be required to be non-combustable 8 Guide to 17 th Edition Consumer Units

Socket Outlets Socket outlets for general use in a domestic installation require RCD protection not exceeding 30mA The Regulations prescribe requirements regarding the use and protection of socket outlets, Regulation 411.3.3 requires that an RCD not exceeding 30mA be provided for: It is likely then that every socket outlet in a domestic installation will require protection by an RCD not exceeding 30mA. 1. Socket outlets having a rated current up to 20A 2. Mobile equipment up to 32A that is for use outdoors. Exceptions to item 1 are permitted : a. where, other than for a dwelling, a documented risk assessment determines that RCD protection is not necessary b. Specifically labelled or otherwise suitably identified socket outlets provided for a particular item of equipment. Guide to 17th Edition Consumer Units 9

Cables Buried in the Wall It is usual practice with domestic installations to install cables within the wall structure. We need therefore to consider Section 522, Selection and erection of wiring systems in relation to external influences. The particular requirements of this section apply to cables which are concealed in a wall or partition at a depth of less than 50mm, or where metal partitions are used. There are a number of options of installing cables within the wall: 1. They should be installed within designated safe zones, generally vertically or horizontally from the point, accessory or switchgear or 150mm from the top or adjoining part of the wall, or 2. Comply with 522.6.204 522.6.204 allows for the cable to: i) Incorporate an earthed metal covering which is suitable as a protective conductor. Eg SWA cable. ii) Be enclosed in earthed metal conduit, such that is suitable as a protective conductor. iii) Be enclosed in earthed metal trunking, such that is suitable as a protective conductor. iv) Be protected against damage from penetration by nails or screws. v) Form part of a SELV or PELV circuit However, where none of the items in 522.6.204 apply, then additional protection by an RCD not exceeding 30mA is required. This now applies to commercial installations as well as domestic. 10 Guide to 17 th Edition Consumer Units

Where buried cables are not mechanically protected additional protection by an RCD not exceeding 30mA must be provided Requires RCD Protection Requires RCD Protection Does Not require RCD Protection Stud Partition Brick / Block or Plaster Earthed Metal Condut Guide to 17th Edition Consumer Units 11

Special Locations: Locations Containing a Bath or Shower There are additional requirements to consider for the bath or shower room of the dwelling. Regulation 701.411.3.3 requires that all low voltage circuits within this location shall be additionally protected by an RCD not exceeding 30mA. This would mean 230V lighting, a shower circuit and bathroom heater or towel rail for example will all need RCD protection. An additional requirement in the 3rd amendment is the requirement to protect the circuit with an RCD not exceeding 30mA should the cable pass through and not feed equipment within the zones. It is important to remember the definition of Low voltage and not get it confused with Extra low voltage. Low voltage exceeds 50V and can be as high as 1000V by definition. A standard 13A socket outlet is permitted in this location provided however the socket outlet is more than 3m from the boundary of zone 1. Earlier editions of the regulations required local supplementary bonding be provided connecting together all exposed and extraneous conductive parts in the zones. This is no longer required in this location provided the following conditions are met: All final circuits of the location comply with the automatic disconnection requirements according to regulation 411.3.2. All circuits in the location are RCD protected in accordance with 701.411.3.3. All extraneous-conductive parts of the location are effectively connected to the protective equipotential bonding according to regulation 411.3.1.2. All low voltage circuits in locations containing a bath/shower shall be protected by an RCD not exceeding 30mA 12 Guide to 17 th Edition Consumer Units

Swimming Pools, Saunas & Underfloor Heating Systems Should a dwelling contain a swimming pool, sauna or have an electric underfloor heating system then these are other special locations that need to be considered by the installation designer with respect to the of the layout of the circuits within the consumer unit and the protection requirements. Swimming pools Any socket outlets or switches in zone 2 of a swimming pool location which do not meet the requirements of SELV and that are not electrically separated need to be protected by an RCD rated at 30mA or less. Saunas All circuits are required to be protected by an RCD rated at 30mA or less with the exception of the sauna heater itself unless of course this protection is recommended by the sauna heater manufacturer. Underfloor heating systems An RCD rated at 30mA or less is required to protect the heating units of such equipment. Values of leakage capacitance may need to be obtained from the manufacturer of the heating system in order to avoid unwanted tripping Guide to 17th Edition Consumer Units 13

Other Considerations There are additional Regulations and Codes of Practice that need to be considered during the design of an installation. These will affect the choice of consumer unit. Division of Installation Section 314 calls for the installation to be so divided to: clearly inconvenient for the user of the building Careful consideration of which circuits are connected to a single RCD is required a. Avoid hazards and minimize inconvenience in the event of a fault. b. Reduce the possibility of unwanted tripping of the RCD due to excessive protective conductor currents. To comply with these requirements the installation designer should consider which circuits are connected to a single RCD. For instance it probably not be suitable to connect all the lighting to a single RCD as any fault on any circuit connected to this RCD would lead to the loss of all the lighting circuits, 14 Guide to 17 th Edition Consumer Units

Consumer Unit Standards A consumer unit by definition in BS 7671 is: A particular type of distribution board comprising a typetested and co-ordinated assembly for the control and distribution of electrical energy, principally in domestic premises, incorporating manual means of double-pole isolation on the incoming circuit(s) and an assembly of one or more fuses, circuit-breakers, residual current operated devices or signalling and other devices proven during the type-test of the assembly as suitable for such use. The standard for a consumer unit suitable for use in the UK is BS EN 61439-3 including Annex ZB. This standard prescribes the consumer unit is tested by the manufacturer using specific devices which would usually be from the same manufacturer. It is critical therefore to understand, that any modifications and installation of devices / components other than those approved by the original Consumer Unit manufacturer (including installing devices e.g. MCBs of a different brand from the Consumer Unit), invalidates any testing, certification and warranty. Devices within the consumer unit must be approved by the manufacturer Guide to 17th Edition Consumer Units 15

BS 5839-6:2004 Fire Detection and Alarm Systems for Buildings All new dwellings are required to be provided with a fire detection and alarm system. This is a safety service and is covered in chapter 56 of BS7671:2008. However further reference for dwellings is made to BS5839-6:2004 Fire detection and Fire alarm systems for buildings. Consideration needs to be given to the supply for this circuit. 16 Guide to 17 th Edition Consumer Units

In a standard house, a grade D, category LD3 system is required. This is a mains powered alarm having an integral standby supply. Such a system is required to be either: a. Permanently wired from an independent circuit at the distribution board, or b. Be supplied from a local, regularly used lighting circuit. (there being a means of isolating the supply to the alarms without affecting the lighting). Another consideration is that where, unusually, there is a Grade B* or E** fire alarm and detection system. In this case, account needs to be taken of clauses 15.3(d) and 15.6(c), respectively, of BS 5839-6. Both of these clauses recommend that the circuit serving the fire alarm system should preferably not be protected an RCD, but if RCD protection is required for electrical safety reasons then either: * A Grade B fire detection and fire alarm system comprises fire detectors (other than smoke alarms and heat alarms), fire alarm sounders, and control and indicating equipment meeting specified requirements given in BS 5839 6. This may be required for a large house. ** A Grade E fire detection and fire alarm system comprises one or more mains-powered smoke alarms and possibly heat alarms, with no standby supply. Where RCD protection is needed for smoke detector circuits one option is to supply that circuit only The RCD should serve only the circuit supplying the fire detection and alarm system, or The RCD protection of the fire detection and alarm system circuit should operate independently of any RCD protection for circuits supplying socket outlets or portable equipment. Smoke Guide to 17th Edition Consumer Units 17

Consumer Unit Arrangements The following options, each with their own benefits, can be considered by the installation designer. A consumer unit with a 30mA RCD main switch is likely to be unsuitable for the following reasons: Smoke Lights Lights Sockets Sockets Cooker Shower The cumulative effects of electronic equipment in the modern home, is such that some current is likely to flow in the protective conductor. A 30mA RCD will trip between 15-30mA. This could cause unwanted tripping, regulation 314.1 (iv) refers. Any fault would result in the loss of all the lighting, this could in itself cause a hazard and the lack of power to the fridge / freezer circuit for example would be very inconvenient. Regulation 314.1 (i) asks the designer to consider this eventuality. A consumer unit with a 30mA RCD main switch is unlikely to be suitable to protect all the circuits 18 Guide to 17 th Edition Consumer Units

Option 1 Main Switch with RCBO s On All Circuits Smoke Lights Lights Sockets Sockets Cooker Shower A standard main switch disconnector controlled consumer unit could be used with every circuit having individual RCD protection at 30mA. This could be achieved by selecting RCBO s for every outgoing circuit instead of the usual MCB s. A fault on any circuit would not affect other circuits and hence all relevant regulations would be met by such a design. This arrangement is particularly suitable for installations connected to a TT earthing system. Selecting RCBO s for every outgoing circuit meets all relevant regulations Guide to 17th Edition Consumer Units 19

This arrangement provides a dedicated RCBO for the smoke detector circuit Option 2 Split Load Twin RCCB plus Dedicated RCBO Lights Sockets Cooker Lights Sockets Shower Smoke This arrangement provides a dedicated 30mA RCBO for the smoke detector circuit, but combines the rest of the circuits across two further 30mA RCCB s. Careful arrangements of the circuits can reduce the likelihood of nuisance tripping, thereby limiting the inconvenience or potential hazards that a loss of supply can cause by limiting the number of circuits affected. 20 Guide to 17 th Edition Consumer Units

Option 3 Split Load 3 RCCB Board This arrangement provides an RCD for the smoke detector circuit which could also supply other circuits e.g. lighting Lights Smoke Lights Sockets Shower Sockets Cooker This arrangement provides a 30mA RCCB for the smoke detector circuit which could also supply other circuits e.g. lighting, and combines the rest of the circuits across two further 30mA RCCB s. Careful arrangements of the circuits can reduce the likelihood of unwanted tripping, thereby limiting the inconvenience or potential hazards that a loss of supply can cause by reducing the number of circuits affected. Guide to 17th Edition Consumer Units 21

Careful design of circuits to ensure nuisance tripping is unlikely Option 4 Split Load Twin RCCB Smoke Lights Shower Lights Sockets Sockets Cooker This arrangement provides two separate 30mA RCCBs with the circuits spread across both. The design of the circuit arrangements need to ensure that unwanted tripping is unlikely, thereby limiting the inconvenience or potential hazards that a loss of supply can cause. However with several circuits being supplied from on RCD, certain compromise must be accepted. 22 Guide to 17 th Edition Consumer Units

If the smoke alarm circuit is not to be protected by an RCD it must be installed using a method from 522.6.204 Option 5 Split Load Twin RCCB plus Unprotected Circuit Under the 17 th Edition requirements it is still possible to install some circuits in domestic premises that are not fed via an RCD. Different wiring systems would need to be used. The cost of installation could rise considerably if most circuits were installed using armoured cable or earthed metal conduits. Lights Sockets Cooker Lights Sockets Shower Smoke The smoke alarm circuit could be installed in such a way to negate the need for RCD protection, this may be possible by using one of the wiring methods described in 522.6.204 for the length of run that the cable is in the wall (use of earthed metal conduit for example). Or depending on the layout of the property there maybe an attached garage for example where surface wiring might be possible. The requirements of that regulation are therefore not applicable. The level of compliance with the Regulations would therefore be the same as option 2 Split Load Twin RCCB plus dedicated RCBO. Guide to 17th Edition Consumer Units 23

Conclusions Training Courses It is clear that domestic installations conforming to the 17 th Edition of the Wiring Regulations are likely to require increased use of RCD (Residual Current Devices) and careful consideration from designers and installers is required to meet the requirements of the regulations. Hager runs an on-going programme of training courses targeted towards wholesale trade partners, specification engineers and installation contractors. Hager training courses satisfy the Continuing Professional Development - CPD, requirements of the major engineering institutions. To register yourself on to one of our training courses in your area please visit our website www.hager.co.uk and click on the services section. 24 Guide to 17 th Edition Consumer Units

Residual Current Devices used in Consumer Units RCD - Residual Current Device A generic term for devices providing earth fault protection. RCBO - Residual Current Operated Circuit-Breaker with Integral Overcurrent Protection A mechanical switching device designed to make, carry and break currents under normal service conditions and to cause the opening of the contacts when the residual current attains a given value under specified conditions. In addition it is designed to give protection against overloads and/or short circuits and can be used independently of any other overcurrent protective device within its rated short circuit capacity. RCCB - Residual Current Operated Circuit-Breaker without Integral Overcurrent Protection A mechanical switching device designed to make, carry and break currents under normal service conditions and to cause the opening of the contacts when the residual current attains a given value under specified conditions. It is not designed to give protection against overloads and/or short circuits and must always be used in conjunction with an overcurrent protective device such as a fuse or circuit-breaker. Consumer Unit RCCB MCB RCBO Guide to 17th Edition Consumer Units 25

Hager Ltd. Internal Sales Hotline: 01952 675612 Hortonwood 50 Internal Sales Faxline: 01952 675645 Telford Shropshire Technical Helpline: 01952 675689 TF1 7FT Technical Faxline: 01952 675557 www.hager.co.uk technical@hager.co.uk Hager Ltd. Northern Ireland Tel: 028 9077 3310 Unit M2 Northern Ireland Fax: 028 9073 3572 Furry Park Industrial Estate Swords Road Republic of Ireland Tel: 1890 551 502 Santry Republic of Ireland Fax: 1890 551 503 Dublin 9 www.hager.ie Ireland