Self-regulating Roof Heat Cable

Similar documents
Toll Free:

Self-regulating Roof Heat and Gutter Trace Cable

Toll Free:

Toll Free:

PLSRR Heat Trace Cable Data Sheet

CATALOG. Toll Free:

CATALOG. Toll Free:

Principle of Operation:

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Commercial and Residential Self-Regulating Heating Products

Drexan Energy Systems Inc.

INDUSTRIAL HEAT TRACE

FTC-HST WARNING: CAUTION:

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

H908 WinterGard Plug-in Power Connection Kit with End Seal

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

Gardian W51. Approvals

Roof and Gutter De-Icing

HS-TSPLICE - HEATSHRINK TEE / SPLICE. Installation Instructions

NELSON HEAT TRACING SYSTEMS

IceStop System Installation and Operation Manual

SERGE BARIL GTKB GUT TRACE KIT BAG

Heating cable solutions for temperature-related problems

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

ComfortTile Floor Heating Systems

XL-Trace System Application and Design Guide

NELSON HEAT TRACING SYSTEMS INSTALLATION

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

C Electrical Connection Kit

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

Design Guide and Installation Details for Self-Regulating Heating Cable

F1202 TRACE HEATING. Road & Ramp

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

Fire Sprinkler Freeze Protection Design / Install Guide

Consignes d installation

NELSON HEAT TRACING SYSTEMS

C A Heating Cable Gland Kit

Toll Free:

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

The IceFree Eave System

Union County Vocational - Technical Schools Scotch Plains, New Jersey

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

RayClic Connection System

NELSON HEAT TRACING SYSTEMS

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Keep your home snow and ice free with. WARMUP Outdoor Heating Solutions. From the world s best-selling electric floor heating brand

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

NELSON HEAT TRACING SYSTEMS

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

AKOCable Heating Cable Solutions Electrical Tracing

SERGE BARIL HEAT TRACING SYSTEMS

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

NELSON HEAT TRACING SYSTEMS

AKOCABLE Heating Cable Solutions Electrical Tracing

NELSON HEAT TRACING SYSTEMS

Freezer Frost Heave Prevention

ROOF ICE MELT (RIM) SYSTEM

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

SELF-REGULATING PIPE TRACING HEATER CABLE

ROOF ICE MELT (RIM2) SYSTEM

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

XL-Trace System Installation and Operation Manual

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

EGS/Easy Heat Product Catalog

FreezGard. Self-regulating crankcase heater. Product Overview

First Trace Heating Product Details

Installation & Maintenance

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

CARAPACE. and terminating. Patents USA and Canada

Anti frost. Snow Melting USA 2012 USA 2014

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

HEATRACE. Young Chang Silicone Ltd, Co. SELF-REGULATING PIPE TRACING HEATER CABLE. Installation, Operation & Maintenance Manual

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

ADDITIONAL INFORMATION

Electric Floor Heating Cables

SEALING FIBER SEALING COMPOUND

Cable Limiters Increase System Reliability Decrease Downtime

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Documentation. Parallel Heating Cable. Type: ELP

Data Sheet. Self regulating heating tapes. RS stock numbers

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

HotEdge Rail TM

MARATHON HEATER. File # E Made in USA

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

Multi-Use Freeze Protection for Pipes, Tanks and Vessels of All Types and Sizes.

Parallel Heating Cables Standard types... 24

Transcription:

Self-regulating Roof Heat Cable Most roof deicing applications are best served by using Warmzone s self-regulating heat cable. The heat cable can be installed in gutters downspouts to keep structures safe from ice damage frost erosion. The self-regulating heat cable features an irradiated conductive core that increases its heat output as the ambient falls, decreases its output when the rises. Features Benefits Will not overheat or burnout when overlapped Superior quality outer jacket carbon core Features advanced technology that results in highly effective, energy efficient operation Can be cut to length in the field Fully automated Maintenance free Protects roofs by preventing ice dams ice buildup Several roof heating options are available. Warmzone roof gutter deicing systems are compatible with the following stard materials: Roof Materials: Gutter/Downspout: Shake / Shingle Metal Rubber / Tar Plastic Cable Maximum Cable Length in feet at Cable Breaker Size RHSRR-6-1 RHSRR-6-2 RHSRR-8-1 RHSRR-8-2 RHSRR-10-1 RHSRR-10-2 RHSRR-12-1 RHSRR-12-2 Startup Temp. 120 V 240 V Breaker Size 15A 20A 30A 40A 15A 20A 30A 40A 50 F (+10 C) 230 270 270 270 460 540 540 540 32 F (0 C) 230 270 270 270 460 540 540 540 14 F (-10 C) 180 210 270 270 360 420 540 540 0 F (-18 C) 140 190 270 270 285 380 540 540-20 F (-29 C) 125 165 250 270 250 330 500 540-40 F (-40 C) 110 145 220 270 220 295 440 540 50 F (+10 C) 150 200 210 210 300 400 420 420 32 F (0 C) 150 200 210 210 300 400 420 420 14 F (-10 C) 140 150 205 210 280 300 410 420 0 F (-18 C) 100 130 200 210 200 265 400 420-20 F (-29 C) 85 115 175 210 175 235 350 420-40 F (-40 C) 80 105 155 210 155 210 315 420 50 F (+10 C) 120 160 180 180 240 315 360 360 32 F (0 C) 105 140 170 180 210 280 340 360 14 F (-10 C) 95 125 165 180 190 250 330 360 0 F (-18 C) 80 110 160 180 160 215 325 360-20 F (-29 C) 70 95 140 180 145 190 285 360-40 F (-40 C) 60 85 125 170 125 170 255 340 50 F (+10 C) 80 140 150 150 160 270 310 310 32 F (0 C) 75 130 145 150 150 260 290 310 14 F (-10 C) 70 115 142 150 140 230 285 310 0 F (-18 C) 60 80 140 150 120 160 280 310-20 F (-29 C) 50 65 110 150 105 140 225 310-40 F (-40 C) 45 60 90 140 90 125 190 280 Wood / Metal Wood * Lengths may vary. Please contact a Warmzone representative for more information. Heated roof valley edges. Warmzone pre-terminated self-regulating heat cable with without a ground fault circuit interupter (GFCI). 26

Self-Regulating Heat Cable System Overview Roof Deicing Toll Free: 888.488.9276 www.warmzone.com sales@warmzone.com 27

Self-Regulating Heat Cable Comparison Warmzone self-regulating heat cable features a more flexible outer jacket more durable carbon core than other leading brs of self-reg cable. These features provide more consistent performance, longer lifespan, easier installation in cold s. Key Features of Warmzone Self-regulating Heat Cable vs. Other Cable Brs Outer Jacket Quality Typical self-regulating heat cable The outer jacket of typical self-reg cable tends to bubble or separate from the cable core when the cable is manipulated for turns. These irregularities create stress points on the cable that can result in water reaching the core, leading to erratic heating eventual cable failure. Other Leading Brs of Self-regulating Cable The outer jacket of most self-regulating heat cable separates from the core at a typical bend radius of 2 inches. Warmzone Self-regulating Heat Cable Warmzone self-regulating heat cable features a higher quality outer jacket that does not bubble. This reduces the chances of water seepage cable failure. Warmzone Self-regulating Heat Cable Warmzone self-regulating heat cable does not bubble at an even tighter bend radius of 1½ inches. Installation at Low Temperatures Typical Self-regulating Heat Cable Typical self-regulating cable has a minimum installation of 32-40 F. This is because the carbon in the cable becomes brittle can easily break when bent or manipulated at low s. The outer jacket also becomes stiff, making the securing of cable to the roof, gutter, or pipes difficult during cold weather installations. The outer jacket tends to pucker pull away from the core when making bends, compromising the cable s integrity leading to cable failure. Therefore installing most self-regulating heat cable at s below 40 F is not recommended. Warmzone self-regulating heat cable plug with GFCI. Warmzone Self-regulating Heat Cable Warmzone self-regulating cable features a higher quality carbon center that is more resilient in low s, thereby allowing the cable to be safely installed at s as low as 0 F. The higher quality outer jacket also remains flexible at low s, resulting in more reliable performance easier installation when securing to roofs, gutters, pipes. In all the years I ve been installing roof heating systems, I ve noticed that bubbles in the outer jacket of the cable almost always result in a point of failure. The superior outer jacket of Warmzone s self-reg cable helps to eliminate this problem. Eric W., Roofing Contractor 28

RHSRL Heat Trace Cable Data Sheet Warmzone s RHSRL self-regulating heat cable is the cable of choice for roof heating gutter trace applications. The UL listed cable features a flexible outer jacket durable carbon core, providing consistent performance, long lifespan, easy installation in cold s. Technical Data for RHSRL Heat Cable Power Output Curves Watts per Foot vs. Temperature 25.0 Service voltage 110-120V, 220-277V Maximum maintain or continuous exposure (power on) Maximum intermittent exposure 1000 hours (power on/off) Minimum installation +149 F (65 C) +185 F (85 C) -40 F (-40 C) Power Ouput (W/FT) 20.0 15.0 10.0 5.0 RHSRL-6 PLSRL-6 RHSRL-8 PLSRL-8 RHSRL-10 PLSRL-10 RHSRL-12 PLSRL-12 Protective braid resistance Bus wire gauge Approvals <.006Ω/ft. 16AWG cul, ATEX, IECEx 0.0-40 -22-4 14 32 50 68 86 104 122 140-40 -30-20 -10 0 10 20 30 40 50 60 Temperature (F C ) Warranty 2 years (Not prorated) RHSRL Cable Dimensions Type Dimensions Minimum Bend Radius RHSRL-CR 10.9 x 6.0mm 1.4 inches (36mm) Maximum Length (feet) vs Circuit Breaker Size Cable Startup Temp. 120 V 240 V RHSRL-6-1 RHSRL-6-2 RHSRL-8-1 RHSRL-8-2 RHSRL-10-1 RHSRL-10-2 RHSRL-12-1 RHSRL-12-2 Breaker Size 15A 20A 30A 40A 15A 20A 30A 40A 50 F (+10 C) 230 270 270 270 460 540 540 540 32 F (0 C) 230 270 270 270 460 540 540 540 14 F (-10 C) 180 210 270 270 360 420 540 540 0 F (-18 C) 140 190 270 270 285 380 540 540-20 F (-29 C) 125 165 250 270 250 330 500 540-40 F (-40 C) 110 145 220 270 220 295 440 540 50 F (+10 C) 150 200 210 210 300 400 420 420 32 F (0 C) 150 200 210 210 300 400 420 420 14 F (-10 C) 140 150 205 210 280 300 410 420 0 F (-18 C) 100 130 200 210 200 265 400 420-20 F (-29 C) 85 115 175 210 175 235 350 420-40 F (-40 C) 80 105 155 210 155 210 315 420 50 F (+10 C) 120 160 180 180 240 315 360 360 32 F (0 C) 105 140 170 180 210 280 340 360 14 F (-10 C) 95 125 165 180 190 250 330 360 0 F (-18 C) 80 110 160 180 160 215 325 360-20 F (-29 C) 70 95 140 180 145 190 285 360-40 F (-40 C) 60 85 125 170 125 170 255 340 50 F (+10 C) 80 140 150 150 160 270 310 310 32 F (0 C) 75 130 145 150 150 260 290 310 14 F (-10 C) 70 115 142 150 140 230 285 310 0 F (-18 C) 60 80 140 150 120 160 280 310-20 F (-29 C) 50 65 110 150 105 140 225 310-40 F (-40 C) 45 60 90 140 90 125 190 280 ORDERING INFORMATION RHSRL- o - o - o For example: RHSRL-6-2-CR Outer jacket CR=Thermoplastic Supply Voltage 1=110-120VAC; 2=208-277VAC Output Power (at 40 F) Example: RHSRL-6-2-CR = 6 watt, 208-277V, Thermoplastic outer jacket Approvals: Warmzone selfregulating heat cable.

RHSRR Heat Trace Cable Data Sheet RHSRR is self-regulating heat cable that can be used for roof / gutter heating pipe tracing applications. The cable features a flexible, UV stabilized thermoplastic elastomer overjacket that protects the durable carbon core for wet applications exposure to the sun. The parallel heating cable is designed for a variety of industrial applications environments, including explosion-hazardous nonhazardous areas, can be used for plastic or metal pipe freeze protection maintenance of pipes, tanks, valves. The cable includes a NON-PRORATED 10-year warranty. Technical Data for RHSRR Heat Cable Service voltage 110-120V, 220-277V Maximum maintain or continuous exposure (power on) Maximum intermittent exposure 1000 hours (power on/off) Minimum installation Protective braid resistance Bus wire gauge Approvals Warranty Certifications +149 F (65 C) +185 F (85 C) -40 F (-40 C) <.006Ω/ft. 16AWG culus, hazardous, CSA, ATEX, IECEx 10 years (Not prorated) Class I, Div.2 Groups A, B, C, D Class II, Div.2 Groups E, F, G Class III Maximum Length (feet) vs Circuit Breaker Size Power Output Curves Watts per Foot vs. Temperature Power Ouput (W/FT) 22.0 20.0 18.0 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 0.0-40 -22-4 14 32 50 68 86 104 122 140-40 -30-20 -10 0 10 20 30 40 50 60 Temperature (F C ) RHSRR Cable Dimensions Type Dimensions Minimum Bend Radius PLSRR-6 RHSRR-6 PLSRR-8 RHSRR-8 PLSRR-10 RHSRR-10 PLSRR-12 RHSRR-12 RHSR-CR 12.6 x 6.0mm 1.4 inches (36mm) Cable RHSRR-6-1 RHSRR-6-2 RHSRR-8-1 RHSRR-8-2 RHSRR-10-1 RHSRR-10-2 RHSRR-12-1 RHSRR-12-2 Startup Temp. 120 V 240 V Breaker Size 15A 20A 30A 40A 15A 20A 30A 40A 50 F (+10 C) 230 270 270 270 460 540 540 540 32 F (0 C) 230 270 270 270 460 540 540 540 14 F (-10 C) 180 210 270 270 360 420 540 540 0 F (-18 C) 140 190 270 270 285 380 540 540-20 F (-29 C) 125 165 250 270 250 330 500 540-40 F (-40 C) 110 145 220 270 220 295 440 540 50 F (+10 C) 150 200 210 210 300 400 420 420 32 F (0 C) 150 200 210 210 300 400 420 420 14 F (-10 C) 140 150 205 210 280 300 410 420 0 F (-18 C) 100 130 200 210 200 265 400 420-20 F (-29 C) 85 115 175 210 175 235 350 420-40 F (-40 C) 80 105 155 210 155 210 315 420 50 F (+10 C) 120 160 180 180 240 315 360 360 32 F (0 C) 105 140 170 180 210 280 340 360 14 F (-10 C) 95 125 165 180 190 250 330 360 0 F (-18 C) 80 110 160 180 160 215 325 360-20 F (-29 C) 70 95 140 180 145 190 285 360-40 F (-40 C) 60 85 125 170 125 170 255 340 50 F (+10 C) 80 140 150 150 160 270 310 310 32 F (0 C) 75 130 145 150 150 260 290 310 14 F (-10 C) 70 115 142 150 140 230 285 310 0 F (-18 C) 60 80 140 150 120 160 280 310-20 F (-29 C) 50 65 110 150 105 140 225 310-40 F (-40 C) 45 60 90 140 90 125 190 280 ORDERING INFORMATION RHSRR- o - o - o (RHSRR-8-2-CR) Approvals: Outer jacket CR=Thermoplastic Supply Voltage 1=110-120VAC; 2=208-277VAC Output Power (at 40 F) Example: RHSRR-8-2-CR = 8 watt, 208-277V, Thermoplastic outer jacket

Self-Regulating Roof Heating Cable Above: Example of gutter damage caused by heavy ice buildup. Right: House with roof deicing system installed at roof s edge. RHSR RoofHeat Cable Accessories JSR14 - Roof clips A Roof clips - 50 per bag JSR12 - End seal kit A Heat shrinkable tubes (2) C Heat shrink end caps (2) B Woven braids (2) JSR15 - Downspout hanger kit A Hanger bracket B Clamp ties JSR10 - Splice / tee kit A B C D E F Clamp tie Mastic strips (1½ long x 1 wide) Heat-shrinkable tube (8 long x 1 diameter) Heat-shrinkable tube (1 long x ⅛ diameter) Heat-shrinkable tube (1 long x ½ diameter) Uninsulated braid crimp G H I J K Cable ties Insulated bus wire crimps Black cloth tape (6 long) Heat-shrinkable cap Heat-shrinkable tube for ground JSR00 - Power connection kit - with single end seal kit (JSR12) A B C D E F G Black cloth tapes (6 long x 1 width) H Plug-in ground-fault equipment protection device I Black heat-shrinkable tube (8 long x ¾ diameter) J Black heat-shrinkable tube (5 long x ¾ diameter) K Black heat-shrinkable tube (1 long x ⅛ diameter) L Black heat-shrinkable tube (1 long x ½ diameter) M Black heat-shrinkable tube (1½ long x ⅓ diameter) Toll Free: 888.488.9276 Uninsulated braid crimp Uninsulated bus wire crimps Mastic strips Clamp ties Warning labels Deicing/snowmelt equipment labels www.warmzone.com sales@warmzone.com 35 Roof Deicing Warmzone roof deicing systems can save you money in the long run be eliminating costly roof repairs water damage. Warmzone s self-regulating heat cable low-voltage systems are easy to customize install.

Self-Regulating Heat Cable Specs Technical Data Service voltage Maximum maintain or continuous exposure (power on) Maximum intermittent exposure 1,000 hours (power on or off) Minimum installation Protective braid resistance Bus wire gauge Approvals Certifications 110-120, 208-277 V 149 F (65 C) -40 to 185 F (-40 to 85 C) -40 F (-40 C) < 18.2Ω/km 16 AWG CSA; ordinary hazardous Class I, Div.2 Groups A,B,C,D Class II, Div.2 Groups E,F,G Class III For information about Warmzone roof heating cable accessories, refer to the information on the previous page. For additional information, please contact a Warmzone representative at 888.488.9276. RHSR Cable Accessories Controls Item Number JSR00-Roof JSR03-Aluminum JSR03-Fiberglass Description Power connection kit Aluminum application tape Fiberglass application tape JSR08 Plug-in cord set, 120 V GFCI, 125 ft. maximum run length JSR10 Splice / tee kit JSR12 End seal kit JSR12L End seal with light (can be used at beginning or end) JSR14 Roof clips - 50/bag JSR-14IR Insulated roof clips - 50/bag JSR15 Downspout hanger kit WS-115 Air sensing NEMA 4 outdoor thermostat 120/240 V WS-115R Surface sensing NEMA 4 outdoor thermostat WS-8C Aerial mounted snow switch with remote moisture sensor (30 amps; 120-277 V) WARMZONE ROOF HEATING CABLE ORDERING INFORMATION Pre-Terminated Self-Regulating Cable (Pipe, Roof Gutter) Item Code Description Length (feet) Output @ 50 F Voltage RHSR-120-50 Pre-terminated self-regulating heat cable 50 6W/ft. 120 RHSRT-120-75 Pre-terminated self-regulating heat cable 75 6W/ft. 120 RHSRT-120-100 Pre-terminated self-regulating heat cable 100 6W/ft. 120 RHSRT-120-50 GF Pre-terminated self-regulating heat cable 50 6W/ft. 120 with ground fault protection RHSRT-120-75 GF Pre-terminated self-regulating heat cable 75 6W/ft. 120 with ground fault protection RHSRT-120-100 GF Pre-terminated self-regulating heat cable with ground fault protection 100 6W/ft. 120 Self-Regulating Cable (Pipe, Roof Gutter) RHSR-120-5 Self-regulating heat cable 250 /500 /1000 ft. 5W/ft. 120 RHSR-120-8 Self-regulating heat cable 250 /500 /1000 ft. 8W/ft. 120 RHSR-120-10 Self-regulating heat cable 250 /500 /1000 ft. 10W/ft. 120 RHSR-120-12 Self-regulating heat cable 250 /500 /1000 ft. 12W/ft. 120 RHSR-240-5 Self-regulating heat cable 250 /500 /1000 ft. 5W/ft. 208-277 RHSR-240-8 Self-regulating heat cable 250 /500 /1000 ft. 8W/ft. 208-277 RHSR-240-10 Self-regulating heat cable 250 /500 /1000 ft. 10W/ft. 208-277 RHSR-240-12 Self-regulating heat cable 250 /500 /1000 ft. 12W/ft. 208-277 *Cut fee *Cut fee for non 250/500/1000-foot rolls 36