Gfci Self Test Duplex 20A 125V WH

Similar documents
Arrow Hart specification grade GFCI receptacles

Arrow Hart hospital grade self-test GFCI receptacles

AF/GF dual-purpose receptacles

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

Tamper & Weather Resistant Receptacles

Residential Occupancy & Vacancy Sensors

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Toggle AL series dimmer

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Aspire LED, CFL & Incandescent Dimmer

SAL06PBK 300/600W 120V Dimmer. Features. Dimensions and Weight. Long Description

Smart AL series dimmers

Toggle AL series dimmer

Slide AL series dimmer

Smart AL series dimmers

Decorator AL series dimmer

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.

Aspire smart AL dimmer

Recp Duplex 20A 125V 2P3W STR Swire WH

Recp HG Dup 20A 125V 2P3W STR B/Swire WH

TAMPER & WEATHER RESISTANT RECEPTACLES

Receptacles. Wiring Devices Receptacles. Receptacle Families. Receptacle Colors. Standard Grade. Academy Series Outlets. Decorator Standard Grade

3099-2E. Technical Information

0ACDT2000MV Ultasonic/Infared Occ Sensor

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

The Safer Living Collection

AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.

Installation Instructions

Switch Toggle DP 20A 120/277V Swire Iv

The most complete line of proven safety solutions.

Gen Purpose Wiring Devices - Gen Purpose Switches

Introducing Hermaphroditic Blade and Receptacle Connector

AH8219HG Conn HG 15A 125V 2P3W STR BW

SECTION (16140) - WIRING DEVICES

Wallbox Lighting Controls Project Name:

Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles

PART GENERAL 1.01 SECTION INCLUDES

Marathon Special Products

CIRCUITPRO Self Test Ground Fault Receptacles

2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

Lighting and Fan Speed Controls

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Power Blocks - Splicer/Distribution

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

GE Industrial Solutions. Residential Electronic Circuit Interrupters

RZI06, RZE06, RZI10, RZM10

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:

GFCI Products Buying Guide

SIMPLEX WEATHERPROOF CONTROL PANELS

Introducing SlimSeal SSL Connector

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Installation and Operation Manual

T6984F,G Electronic Floating Control Thermostats

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

IllumaTech Innovations

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

DTA. Motor thermistor relay. Benefits. Description

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Wallbox Lighting Controls Project Name:

SPECIFICATION SUBMITTAL

CAUTION READ CAREFULLY

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

LED14DR5627K 14W Led 5"/6" Rec DWNLT 27K

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Ground Breaking Innovation

DETECT-A-FIRE Heat Detectors

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Remote Alarm Panels Features

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

ASCO Series 185 Power Transfer Switches

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

* Consult factory on conditions for approval acceptability

Across-the-Line SERIES MP300 Combined Manual and Automatic

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

CMD420 / CMD421 Series

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Product Name Here. SHURTrim Paraffin Block Trimmer. Operator s Manual. Histology Innovation for a NEW Generation. Catalog #s ST-120, ST-220

Model GIT 4 Gutter Snow and Ice Melting Control

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Arc-Fault Circuit Interrupters (AFCIs) Frequently Asked Questions

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

CHAPTER 20 SERVICE EQUIPMENT

Products :: Circuit Protection :: Thermal Circuit Breakers

We ve Got Panels Under Control.

Quality. Trust. Value. Safety.

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

Transcription:

SGF20W Gfci Self Test Duplex 20A 125V WH Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Description Long Description Product Type special features Manufacturer Information Brand Manufacturers Part Number sub brand SGF20W Eaton Wiring Devices Gfci Self Test Duplex 20A 125V WH N/A Wiring Devices & Data/Telecom GFCI SELF TEST DUPLEX 20A 125V WH GFCI Self Test Duplex 20A 125V WH Gfci Self Test Duplex 20A 125V WH If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. Eaton Wiring Devices SGF20W EATON Taxonomies, Classifications, and Categories Category Description Residential GFCI devices Type Self Test Duplex GFCI Packaging Carton 1 Package 10 Weight Per each 0 Uses, Certifications, and Standards Application COMMERCIAL

Technical Data Description 2-pole, 3-wire grounding 15A, 125V/AC 20A, 125V/AC SGF20 TAMPER RESISTANT Design features Performs periodic self-tests to ensure integrity of GFCI protection Visual trip indicator light gives quick notification of a tripped or end of life condition Meets and exceeds 10 ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used Ground termination with back wire clamp provides secure wiring and reduces installation time Tamper resistant shutters help prevent foreign objects from being inserted Line side terminals are backed out and staked for fast installation Horizontal test/reset button alignment provides larger unobstructed area WEATHER RESISTANT TRSGF15 Test and reset buttons are color matched to provide superior aesthetics Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire When downstream receptacles are wired from load side, a 20A feed-through rating offers full protection Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly Tri-combo head terminal and mounting screws UL Listed, fully compliant with all latest UL943 Class A GFCI requirements WRSGF15 TWRSGF15 Tamper resistant models comply with 2014 NEC Article 406.12 Weather resistant models comply with 2014 NEC Article 406.9 that states that all receptacles installed in wet or damp locations must be weather resistant Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations Matching thermoplastic wallplate included

Technical Data Table 1. Specification grade Rating Catalog no. Description A V/AC NEMA Color suffix SGF15 Duplex GFCI, 15 125 5-15R A, B, BK, GY, SGF15 -M SGF15F WRSGF15 SGF15W-LSBU Duplex GFCI with mid-size wallplate, Duplex GFCI NAFTA compliant, Weather resistant duplex GFCI, VGF 15W 50-pack No screws & wallplates 15 125 5-15R A, LA, V, W 15 125 5-15R B, BK, GY, LA, 15 125 5-15R B, GY, V, W 15 125 5-15R SGF20 Duplex GFCI, 20 125 5-20R A, B, BK, GY, SGF20F WRSGF20 Duplex GFCI NAFTA compliant, Weather resistant duplex GFCI, 20 125 5-20R B, BK, GY, LA, 20 125 5-20R B, GY, V, W Table 2. Specification grade, tamper and weather resistant Rating Catalog no. Description A V/AC NEMA Color suffix TRSGF15 TRSGF15 -M TRSGF15F TWRSGF15 TRSGF20 TRSGF20F TWRSGF20 Tamper resistant duplex GFCI, Tamper resistant duplex GFCI with mid-size wallplate, back & side wire Tamper resistant duplex GFCI NAFTA compliant, back & side wire Tamper & weather resistant duplex GFCI, Tamper resistant duplex GFCI, Tamper resistant duplex GFCI NAFTA compliant, back & side wire Tamper & weather resistant duplex GFCI, 15 125 5-15R A, B, BK, GY, 15 125 5-15R A, LA, V, W 15 125 5-15R B, BK, GY, LA, 15 125 5-15R B, GY, LA, V, W 20 125 5-20R A, B, BK, GY, 20 125 5-20R B, BK, GY, LA, 20 125 5-20R B, GY, LA, V, W Table 3. GFCI status indicator Test indicator RED LED Test indicator AMBER LED Diagnosis Color suffix OFF OFF Device is functioning properly OR branch circuit may have no power Manually depress TEST button to trip device. Amber light should come ON If Amber light does not come ON, check if there is power to the branch If Amber light does come ON, manually depress the RESET button to restore power to the device If GFCI does not reset, replace GFCI If GFCI does reset, device is functioning properly OFF ON Device is in tripped state Manually depress the RESET button to restore power to the device If GFCI does not reset, replace GFCI Blinking OFF Device s end of life indication OR device is in reset state Blinking ON Device s end of life indication OR device is in tripped state Manually depress TEST button to trip device. Amber light should come ON If Amber light does not come ON, check if there is power to the branch If Amber light does come ON, manually depress the RESET button to restore power to the device If it does not reset, and/or the blinking continues, replace GFCI Manually depress the RESET button to restore power to the device If it does not reset, and/or the blinking continues, replace GFCI Applications are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, breakrooms and food service areas, the NEC requires. Arrow Hart are UL Listed and fully compliant with all of the latest UL943 Class A GFCI and UL498 requirements. Additionally, GFCIs incorporate lock-out functionality to protect against mis-wired line-load connections and GFCI circuitry damage. Table 4. Specifications Catalog no. GFCI 15A & 20A SGF and SGF F series GFCI 15A & 20A; TRSGF, TRSGF F, WRSGF, TWRSGF series Device type Specification grade Specification grade tamper resistant & weather resistant duplex Wiring type Back & side wire Back & side wire Testing & code compliance Environmental specifications culus Listed to UL 498 and UL 943, file no. E60120 Meets all UL 943 (GFCI), UL 498 (receptacles) and applicable CSA requirements NOM certified Flammability: Meets UL 94 requirements; V2 rated Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF) Electrical specifications Dielectric voltage: Withstands 2000V per UL 498 Current interrupting: Yes, at full-rated current Temperature rise: Max. 30ºC (86 F) after 100 cycles of overload @ 150% of rated current (DC) Trip time: 0.025 seconds (Class A) Frequency: 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A feed-through Short circuit testing: Meets and exceeds 10 ka Maximum interrupting capacity: 20 Amps Mechanical specifications Terminal accommodation: #14-10 AWG Voltage ratings: Permanently marked on device culus Listed to UL 498 and UL 943, file no. E60120 Meets all UL 943 (GFCI), UL 498 (receptacles) and applicable CSA requirements NOM certified Flammability: Meets UL 94 requirements; V2 rated Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF) Dielectric voltage: Withstands 2000V per UL 498 Current interrupting: Yes, at full-rated current Temperature rise: Max. 30ºC (86 F) after 100 cycles of overload @ 150% of rated current (DC) Trip time: 0.025 seconds (Class A) Frequency: 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A feed-through Short circuit testing: Meets and exceeds 10 ka Maximum interrupting capacity: 20 Amps Terminal accommodation: #14-10 AWG Voltage ratings: Permanently marked on device 2 EATON www.arrowhart.com

Technical Data Table 5. Materials Catalog no. GFCI 15A & 20A SGF and SGF F series GFCI 15A & 20A; TRSGF, TRSGF F, WRSGF, TWRSGF series Top housing Thermoplastic, polypropylene Thermoplastic, polypropylene; except WR: nylon 6/6 Bottom housing Thermoplastic, PVC Thermoplastic, PVC Strap 0.047 thick steel, zinc-plated 0.047 thick steel, zinc-plated; WR & TWR: nickel-plated Line contacts 0.030 thick brass 0.030 thick brass Terminal & ground screws #8-32 steel, brass-plated; neutral screw nickel-plated, ground screw green Terminal: Brass/nickel-plated steel; WR & TWR brass/nickel-plated stainless steel; Ground: ground screw green on all models, WR and TWR stainless steel Terminal clamps 0.070 thick steel Brass-plated steel; WR & TWR nickel-plated steel Table 6. Color ordering information For ordering devices, include Cat. no. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD (Red), V (Ivory), W (White) A B BK GY LA RD V W Almond Brown Black Gray Lt. Almond Red Ivory White Product dimensions Figure 1. SGF15, SGF15-M & SGF15F Line art with dimensions Figure 2. TRSGF15, TRSGF15-M & TRSGF15F Line art with dimensions EATON www.arrowhart.com 3

Technical Data Product dimensions Figure 3. WRSGF15 Line art with dimensions Figure 4. TWRSGF15 Line art with dimensions 1.26 (32mm) Figure 5. SGF20 & SGF20F Line art with dimensions Figure 6. TRSGF20 & TRSGF20F Line art with dimensions 4 EATON www.arrowhart.com

Technical Data 1.26 (32mm) Figure 7. WRSGF20 Line art with dimensions Figure 8. TWRSGF20 Line art with dimensions Certifications & compliances Catalog no. SGF15 SGF15-M SGF15F TRSGF15 TRSGF15-M TRSGF15F WRSGF15 TWRSGF15 SGF15W-LSBU SGF20 SGF20F TRSGF20 TRSGF20F WRSGF20 TWRSGF20 KEY: culus NAFTA NOM Arrowlink Build-To-Spec ROHS Parts are manufactured and designed in accordance with article 4 of the European Union s RoHS2 directive 2011/65/EU Build-To-Spec Customizable Devices EATON www.arrowhart.com 5

Technical Data Electrical Sector 203 Cooper Circle Peachtree City, GA 30269 United States Eaton.com Cooperwiringdevices.com Electrical Sector Canada Operations 5925 McLaughlin Road Mississauga, Ontario, L5R 1B8 Canada EatonCanada.ca Cooperwiringdevices.com Electrical Sector Mexico Operations Carr. Tlalnepantla - Cuautitlán Km 17.8 s/n Col. Villa Jardín esq. Cerrada 8 de Mayo Cuautitlán, México CP 54800 México Eaton.mx Cooperwiringdevices.com Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2015 Eaton All Rights Reserved Printed in USA Publication No. TD610009EN June 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.