Ultrasonic and Megasonic Cleaners

Similar documents
Operation Procedure for SMiF Wet Hoods (Solvent, Spin Coat, Acid, and Develop Hoods)

Wet Bench Standard Operating Procedures

GENERAL WET BENCH SAFETY AND USES SOP. October 2013 GENERAL SAFETY RULES

Standard Operating Manual. PEL Wet Station X Clean Organic Solvent Station

Lab Safety Plan for Optics Room (Rm117)

Application Data Sheet

Haz Waste Management

Revised: January 8, Goal: Deposit, expose, and develop standard positive photoresist films as an etch mask, liftoff mask, or sacrificial layer.

Polypro Acid Wet Bench UCLA Nanolab Yellow Room. Primary contacts: Max Ho, Wilson Lin. PREPARED BY: Steve Franz DATE Rev 2/01/12

Standard Operating Manual. Ultra Fab Wet Station F Non-standard Processing Station

Whittemore Ultrasonic Cleaner

Instructions on How to Wash and Dry Laundry

Arizona State University NanoFab PARYLENE COATER. Rev D

R I T Title: RCA Bench #2

NRF PDMS Processing SOP 2/12/18 Rev 2 Page 1 of 9. NRF PDMS Processing SOP

Contents. Manufacturing Inc.

General Acids/Bases Bench Right and Left SOP

Instruction Manual for Bench-Top Cleaning Baths

Installation, Operation and Maintenance Instructions

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Ultrasonic Cleaner 13L. Instructions. ight Laser Tool. Laser

Standard Operating Manual

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com

CNS Cleanroom Safety Orientation Form

Cavitator Ultrasonic Cleaner Instruction Manual

+ English + 1. Safety warnings

PERFORM Operating Document

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Standard Operating Manual. Ultra Fab Wet Station C Oxide/ Nitride Etch Station

Manual Ultrasonic Cleaner PCE-UC Series

Safety In Chemistry. Identified Risks and Hazards

Sharper Image. Ultrasonic Eyeglass Cleaner Item No Instructions for Use & Safety Precautions NOTE: FOR INDOOR USE ONLY

Safety Lab Goggles are required! Apron is optional!

from In this issue teamwork... OBSOLESCENCE ALERTS Product Enhancements Akrion Systems News SPECIAL OFFERS!

Teaching Lab Headway Spinner SOP

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

Liftoff/Strip Solvent Bench SOP

Precision Ultrasonic Cleaning Equipment Buyers Guide

Massachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI)

CORPORATE PROFILE CONTENTS History and Highlights 2-3. Key Products and Services 4. Key Personnel 5

Norris Upright Dishwasher

Standard Operating Manual

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

Amerimade RCA Wet Bench SOP Page 1 of 13 Rev /22/2014

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Superior Spa with Aqua-Aire

Ultrasonic Humidifier TALL. Product Manual

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

Cavitator Ultrasonic Cleaners

SAFE WORK PROCEDURE. List the Hazards and risk controls as per risk assessment. assessment reference:

Title: Nitride and Silicon Wet Etch Semiconductor & Microsystems Fabrication Laboratory Revision: I Rev Date: 01/20/2010

HydroFlux Welder Torch System T0-102 / T0-103

NANO-MASTER Single Wafer/Mask Cleaning Systems

Operating Instructions

Operation & Maintenance Manual

Task #1. Quick Overview: Wipe white residue build- up off one of the show tanks (class tank) Procedure: 10. Wash hands.

ULTRASONIC CLEANERS INSTRUCTION MANUAL MODELS

Cavitator Ultrasonic Cleaners

SS2000 Software Configuration Manual

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Operating Instructions

FROTH-PAK ULTRA Premium Foam Insulation Refill Kit and Accessories

Lock-N-Load Sonic Cleaner 2L. Instruction Manual

Best practices in Cleaning and Safety

Nu/Clean AquaBatch XL The Batch Cleaner with the HIGHEST TEMPERATURE PROCESS & the added cleaning power of STEAM!

Measurement Techniques to Characterize an Ultrasonic or Megasonic Cleaning System

BRANSONIC Bransonic Baths

JOKE Basic-Clean. Ultrasonic cleaners. Instruction Manual

Cleaning Procedures in ICP-MS Laboratories

ASPIRE Laboratory Aspirator

Lab Safety and Equipment

Polymer Characterization Facility 165 S. T. Olin Laboratory. Lab Safety Orientation

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Vision Painting Inc. Safety Management System

EPISD RISK MANAGEMENT. Custodial Safety

Bottled Water Dispenser User Manual

PDS 2010 Parylene Coater SOP

Instruction Manual. Immersible & Flange Type Transducer. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

ROTOR COATING WET BENCH OPERATING PROCEDURE

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

Safety procedures: Wear your PPE. Gloves and goggles when filling the chemical bottle, using the machine, and cleaning the machine.

UVM Cosmogenic Laboratory - Quartz Purity Testing

The Most Powerful Bench-top Ultrasonic Cleaner

Mixing Tank, 500 Gallon with Agitator

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

Symphony Plus Pressurized Water Sanitizing Kit P/N

R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008

User manual of CD-2900 ultrasonic contact lens cleaner

CALIBRATION KIT #

Science Department Safety Training Notes

SERVICE REQUIREMENTS

FC 5 FC 5 Premium. OPERATOR MANUAL Floor Cleaner...2 MANUAL DE USUARIO Limpiador de piso...22 MANUEL D UTILISATION Nettoyant pour sols...

Rules for Safe Operation

5.7 L ULTRASONIC CLEANING SYSTEM. BioSonic UC150

Ultrasound cleaning Product catalog

The PURO GRAND Condensate Cleaner Installation instructions: Maintenance instructions:

Transcription:

Ultrasonic and Megasonic Cleaners Megasonic bath with lid on Ultrasonic bath with lid on 1. Introduction There are one ultrasonic bath and two megasonic baths available in NUFAB. One megasonic bath is located in the yellow room. Sample cleaning is done in the user provided beakers (containers) with appropriate cleaning solution. The ultrasonic cleaning uses lower frequencies (40-170 khz). The megasonic cleaning uses higher frequencies (0.925 MHz). The higher frequencies do not cause violent cavitation effects found with ultrasonic frequencies. Thus megasonic cleaning significantly reduces the likelihood of surface damage to the sample being cleaned. Samples that would be damaged by ultrasonic cleaning can be cleaned in the megasonic bath using the same solution. Only DI water will be used as solution in the baths. Only trained and approved (qualified) Users may use these tools. 2. Features and Specifications Two megasonic baths and one ultrasonic bath available. Muti-frequencies available for ultrasonic bath: 40 khz, 72 khz, 104 khz, 170 khz. Power level adjustable: 0-100% of maximum power. Ultrasonic bath dimensions: 9 (length) X 9 (wide) X 9 (depth). Megasonic bath dimensions: 8 (length) X 3 (wide) X 7 (depth). Bath liquid level detection and alarm equipped. Bath liquid circulation available. Software control with touchscreen operation.

3. Safety and Precautions Never put your finger or any body part into the liquid of the ultrasonic bath and megasonic baths. Never directly fill the ultrasonic bath and megasonic baths with your cleaner solution. Never use any acid, base or any mixture of those as the cleaner solution. Only DI water will be used as solution in the ultrasonic bath and megasonic baths. All chemicals must be clearly marked with chemical name, owner s name and contact information. Get approval from a staff member first before bring in any new chemical. Only open the cap of any chemical bottle inside the hood. No waste goes down the drain. All waste must be handled according to the waste procedures. Refer to the MSDS of every chemical that is to be used before handling that chemical. Follow all chemical safety rules. PPE (Personal Protective Equipment): Wearing safety glasses or goggles all the time is required when using ultrasonic bath and megasonic baths. 4. Operating Procedure 4.1 Ultrasonic bath 1. There is a touch screen on the forehead of the hood. After a touch to the touchscreen, a screen shown in Figure 1 should be seen. If a different screen is shown, press the Back button until it goes back to this screen. Figure 1 2. Press the Operations button, a screen shown in Figure 2 will be seen. Press Tank 2 for ultrasonic bath. The Tank 2 Control screen (Figure 3) will be seen.

Figure 2 Figure 3 3. On this screen, you can select the frequency and adjust the power level from 0-100% of the maximum power 320W. In general, a higher frequency will provide a gentler cleaning to your sample. 4. Fill the ultrasonic bath with DI water to a level for your processing purpose. ONLY fill DI water into the ultrasonic bath. Put your beaker (or container), which has been filled with your cleaner solution and sample, into the ultrasonic bath. Make sure your beaker does not float on the water. Put a lid on your beaker. And put the lid of the ultrasonic bath on if it is needed. 5. There is a timer located on the top left side of the hood (Figure 4). On the timer, the red number represents how many seconds is left. And the green number represents the time setting. To set the time, press the button labeled 1, 2, 3, or 4. Changes can be seen to the green number. To start the timer, press the Timer Enable button. Once it reaches zero, a loud sound can be heard. Press the Timer Enable button again to acknowledge it.

Figure 4 6. To start the process, press the System Enable button on the touch screen. When it starts, the System Enable button should change from Off to On. And the Status button should change from Idle to Running. 7. After the cleaning process. Dump the waste to your waste container if you are using a solution other than IPA and Acetone. IPA and Acetone waste can be dumped into the carboy labeled Non-Halogenated in the hood. 8. Rinse all beakers with DI water three times. Clean the working area. 4.2 Megasonic Bath 1. There is a touch screen on the forehead of the hood. After a touch to the touchscreen, a screen shown in Figure 5 should be seen. If a different screen is shown, press the Back button on the screen you can see until it goes back to this screen. Figure 5 1. Press the Operations button, a screen shown in Figure 6 will be seen. Press Tank 1 for megasonic bath. The Tank 1 Control screen (Figure 7) will be seen.

Figure 6 Figure 7 2. On this screen, you can adjust the power level from 0 to100% of the maximum power 250 W. 3. Fill the megasonic bath with DI water to a level for your processing purpose. ONLY fill DI water into the megasonic bath. Put your beaker (or container), which has been filled with your cleaner solution and sample, into the megasonic bath. Make sure your beaker does not float on the water. Put a lid on your beaker. And put the lid of the megasonic bath on if it is needed. 4. There is a timer located on the top left side of the hood (Figure 8). On the timer, the red number represents how many seconds is left. And the green number represents the time setting. To set the time, press the button labeled 1, 2, 3, or 4. Changes can be seen to the green number. To start the timer, press the Timer Enable button. Once it reaches zero, a loud sound can be heard. Press the Timer Enable button again to acknowledge it.

Figure 8 5. To start the process, press the System Enable button on the touch screen. When it starts, the System Enable button should change from Off to On. And the Status button should change from Idle to Running. 6. After the cleaning process. Dump the waste to your waste container if you are using a solution other than IPA and Acetone. IPA and Acetone waste can be dumped into the carboy labeled Non-Halogenated in the hood. 7. Rinse all beakers with DI water three times. Clean the working area.