POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Similar documents
POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

Heliport & Helideck Lighting System. For Non Hazardous and Hazardous Locations. Option: Marine Treatment for superior corrosion protection

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Tower & Obstruction Lighting

Vigilant LED Based Obstruction Lights

Date: 3/11/2019 Initiated By: AAS-100

Vigilant LED Based Obstruction Lights

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

Vigilant LED Based Obstruction Lights

PRODUCT CATALOG HUGHEYANDPHILLIPS.COM

Airfield lighting. Product Brochure

Applications. Standard Materials

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Obstruction Lighting

Obstruction Lighting Guide

SECTION EXTERIOR LIGHTING

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

LMV Series W Low Profile - Medium Base

Tower & Obstruction Lighting Controls

Date: 9/28/2016 Initiated By: AAS-100

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Arlington. Full Cutoff. Utility Series

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

LM40 Medium Intensity Aviation Obstruction Light

Bulletin 855T 70 mm Control Tower Stack Lights

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Lantern Post Top. LED Series

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

RGL (RUNWAY GUARD LIGHT) INSTRUCTION BOOK

Date: DRAFT Initiated by: AAS-100

Washington Series LED Innovative Tradition Continues

Rugged LED shelter lighting

Installation Instruction Manual

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

OL10A & OL32 Obstruction Light

2 General Application Photoelectric Sensors

Lighting for Hazardous & Severe Environments

LED Ultrastar. trobe beacons

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) WEB: IMPORTANT!!!

2 General Application Photoelectric Sensors

T OWER L IGHTING O F T E C H N O L O G Y

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Full Cutoff. Utility Series

OPI COVER SHEET PAGE COUVERTURE DU BPR OPI COORDINATION

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Installation Instruction Manual ILS-S

FAA Obstruction Lighting Buyer s Guide

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Rating. Class I Div II

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Product Specifications MaxLumen MRI LED Diffused Lighting

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

Vanguard Red FTS 371 Medium Intensity RED LED Obstruction Lighting System Reference Manual SERIAL NUMBER. Part Number F

LED Evolution of a Classic

High-Intensity cd Aviation Light

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Post Top Full Cutoff HID

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

Notes. Custom powder coat finished are available.consult factory. To ensure the natural appearance of stainless steel,

MaxGard. Interconnection Systems. Durability. Performance. Safety

Dialight Obstruction LED Solutions

SECTION LIGHTING CONTROLS

SECTION LIGHTING

GAS RESTAURANT RANGE MODELS 24L, 36L/LC, 48L, 481L/LC, 148L/LC, 60 L/LC/LCC, 160L/LC, 260L/LC/LCC

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

STROBE POWER SUPPLIES - two outlets by Tomar Electronics

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

XLFE-4/1. Borosilicate glass globe

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Transcription:

INCANDESCENT Compliances: ETL Certified FAA L-810 per FAA AC 150/5343H at -55 deg C to +55 deg C ETL Listed to UL 1598 at -40 deg C to +55 deg C ETL Listed to CSA C22.2 No. 250.0-04 Canada ICAO Annex 14 Low Intensity Types A (10 cd) & B (32 cd) IMO 2009 MODU Code (2010) paragraphs 13.5.24 & 13.5.25 The POINTSPEC series of incandescent red aviation obstruction lights presents the highest grade technical features and the most options available in the industry. steady-burning obstruction lights are used to mark tall structures that present hazards to air navigation. Use the PPC photoelectric controller or option "-P" to provide automatic lighting activation at dusk in accordance with FAA specifications. All POINTSPEC 's include lens & cover tethers, corrosion protection, stainless steel hardware, ground wires & captive cover screws. Lamp life is 8,000 hours for the 120V and 230V screw base lamps. Point Type Color Lamp & Voltage Entries Style Options -20000 R: Red 116: 116w 120 volts See See See IR: Infrared 116A2: 116w 230 volts Table 1 Table 2 Table 3 45Q: 45w 6.6A 2-pin 1,2 Notes: 1 Limited options; contact Point Lighting See file OL190LED for the LED series of lights 2 Includes 24-inch L-823 lead/plug See file OL150SPC for specification guide FAA L-810 certified as: -20000 red with 116w FAA lamp number 32 For mounting options and plan details, see file 0MOUNTINGS All details are available as AutoCAD files for insertion in project plans -20000-R-116-34B-DJ OL-1.1.0 December, 2016

TABLE 1 ENTRY SELECTION -34B 3/4-inch NPT Bottom Entry -20000-R-116-34B -34S 3/4-inch NPT Side Entry -34F 3/4-inch NPT Feed-thru Entry -10B 1-inch NPT Bottom Entry -10F -M20B -SF 1-inch NPT Feed-thru Entry Note: Junction box styles only Metric Bottom Entry Slipfitter 2.375-inch (60 mm) TABLE 3 OPTIONS OPTION: P FAA PHOTOELECTRIC CONTROLLER Point Lighting PPC mounted and prewired to the to comply with FAA required footcandle specifications. The PPC uses a thermal time delay relay that prevents the accidental turn-off of the lights due to stray lighting. The unit is rated for 5000 on-off operations minimum and the plug-in photocell module is replaceable. Requires a double or single with junction box. OPTION: FF FLOOR FLANGE 5-inches (127mm) square mounting plate with 4 screw holes and 6-inches (152mm) long pipe extension. OPTION: BKT TOWER MOUNTING BRACKET L-shaped mounting plain aluminum plate with with mounting hole for light. Installer drills at site for attachment to tower. OPTION: CF[B] COMPRESSION FITTING Through holes with 1.5-inch long ¼-20 hex head stainless steel screws and sealing washers. Metal cable compression fitting for outside diameter: 12 to 18-mm (0.47 to 0.70-inch). Available for 34L unilet style single lights. OPTION: CF[C] COMPRESSION FITTING Through holes with 1.5-inch long ¼-20 hex head stainless steel screws and sealing washers. Metal cable compression fitting for outside diameter: 12 to 18-mm (0.47 to 0.70-inch). Available for all doubles and junction box style single lights. OPTION: OS OVERRIDE SWITCH For use with photoelectric controller option P. Cover mounted 3-position switch ON-OFF-AUTO. Requires a double or single with junction box. For remote override switch, add item PL40110-3. OPTION: TS TEST SWITCH Cover mounted toggle switch to simulate failure of primary lamp. Intended to demonstrate proper operation of the standby lamp. Requires a double light. Option TSR for use with a remote switch (by others). OPTION: TP TRANSIENT PROTECTION Metal oxide varistors (MOV s) are installed to provide limited protection of installed photocell and/or relay against short duration voltage spikes on the line input and load output. The number and configuration will be appropriate to the version. OPTION: MT MARINE TREATMENT The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C-490 method III, pretreated with chrome-free aluminum conversion coating per US MIL-C-5541 type II, epoxy powder base coat primer and glossy polyester powder coat finish in color RAL 6003 (FED-STD-595 color #14097) dark green. Powder coating per US Department of Defense MIL-PRF-24712A type VI and oven cured. Note: The -20000 is incandescent and, therefore, NVG (night vision) compatible due to the heat signature.

TABLE 2 STYLES Style Transfer Alarm Alarm Pilot Flashing Description Non-Isolated Isolated Light -S1 Single: lamp flashing -S2 Single: non-isolated alarm -S3 Single: cast aluminum junction box -S4 Single: isolated lamp failure alarm -DJ Double: both lamps operating -DT Double: operating lamp & standby with transfer -D1 Double: lamp transfer & pilot light -D2 Double: lamp transfer & alarm -D2.2 Double: both lamps operating & alarm -D3 Double: lamp transfer, alarm & pilot light -D4 Double: lamp transfer & isolated alarm -D4.2 Double: both lamps operating & isolated alarm -D5 Same as Style D4 with pilot light -D6 Same as Style D4 with six (6) wires -D7 Double: both lamps flashing For available options & related specifications, see file OL150SPC Specification Guide Note: The plain single does not have a suffix; a J-box version is required for any single with option P.

SPECIFICATIONS SPECIFICATIONS OF COMMON VERSIONS OF INCANDESCENT OBSTRUCTION LIGHTS DOUBLE OBSTRUCTION LIGHT Description: POINTSPEC double with both lamps operating and large wiring space. No alarm function. (220-240v) double unit with both (2) lamps operating. Alarm sensing, if any, shall be remote from the light unit. There shall be a minimum of 100 cubic inches of enclosed wiring space accessible from the front of the light unit. The lenses of the L-810 light heads and the wiring access cover shall be secured to the unit with tethers. The wiring access cover shall be gasketed to be watertight and have captive screws. Ground wires shall be included. The entire light unit shall be powdercoat painted yellow for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD- 810E, Method 509.3, Procedure I. All hardware shall be stainless steel. The red glass lens shall be Fresnel military Type M-1 and shall be certified to meet U.S. military specifications MIL-L-7082D, MIL-C-7989B and the chromaticity requirements of MIL-C-25050. The aviation obstruction light shall be POINTSPEC Series -20000-R-116-34B-DJ manufactured by Point Lighting Corporation. DOUBLE OBSTRUCTION LIGHT WITH AUTOMATIC LAMP TRANSFER Description: POINTSPEC double with one lamp operating & one lamp standby. Upon failure of the operating lamp, power is transferred to the standby lamp. No alarm function. (220-240v) double unit with one lamp operating and one lamp standby. Upon failure of the operating lamp, power shall be transferred to the standby lamp by means of a current sensing encapsulated electronic module. Alarm sensing, if any, shall be remote from the light unit. There shall be a minimum of 100 cubic inches of enclosed wiring space accessible from the front of the light unit. The lenses of the L-810 light heads and the wiring access cover shall be secured to the unit with tethers. The wiring access cover shall be gasketed to be watertight and have captive screws. Ground wires shall be included. The entire light unit shall be powdercoat painted aviation yellow for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD-810E, Method 509.3, Procedure I. All hardware shall be stainless steel. The red glass lens shall be Fresnel military Type M-1 and shall be certified to meet U.S. military specifications MIL-L-7082D, MIL-C-7989B and the chromaticity requirements of MIL-C-25050. The aviation obstruction light shall be POINTSPEC Series -20000-R-116-34B-DT manufactured by Point Lighting Corporation. DOUBLE OBSTRUCTION LIGHT WITH AUTOMATIC LAMP TRANSFER & ISOLATED ALARM LINE Description: POINTSPEC double with one lamp operating & one lamp standby. Upon failure of the operating lamp, power is transferred to the standby lamp and to alarm contacts. The contacts are isolated dry (voltage free) normally open and normally closed alarm contacts. The installer must provide external power (24v, 120v, 220v, etc.) to the contact(s) which then operate independently of the line power to the lamps. (220-240v) double unit with one lamp operating and one lamp standby. Upon failure of the operating lamp, power shall be transferred to the standby lamp by means of a current sensing encapsulated electronic module. Upon lamp failure, the electronic relay module shall also activate remote alarm contacts. The contacts shall be isolated dry (voltage free). There shall be available both normally open and normally closed alarm contacts. The installer shall provide external power (specify: 24v, 120v, 220v, etc.) to the alarm contact(s) which then operate independently of the line power to the lamp. There shall be a minimum of 100 cubic inches of enclosed wiring space accessible from the front of the light unit. The lenses of the L-810 light heads and the wiring access cover shall be secured to the unit with tethers. The wiring access cover shall be gasketed to be watertight and have captive screws. Ground wires shall be included. The entire light unit shall be powdercoat painted aviation yellow for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD-810E, Method 509.3, Procedure I. All hardware shall be stainless steel. The red glass lens shall be Fresnel military Type M-1 and shall be certified to meet U.S. military specifications MIL-L-7082D, MIL-C-7989B and the chromaticity requirements of MIL-C-25050. The aviation obstruction light shall be POINTSPEC Series -20000-R-116-34B-D4 manufactured by Point Lighting Corporation.

REPLACEMENT PARTS PL10334 Relay, 120/230v PL10001T * Red Lens & Tether PL10455-1 Relay, Alarm 120v Styles S2, D2-D6 PL10491T ** Infrared Lens & Tether PL10455-2 Relay, Alarm 230v Styles S2, D2-D6 PL10024-116 Lamp 116w, 120v PL10494 Gasket, Cover for All Doubles PL10025-116 Lamp 116w, 230v PL10496 Cover & Tether Styles S1-S4 PL10049 O-Ring Seal PL10462 Cover & Tether Double All Styles PL10076-S *** Lamp Socket PL10606-A-120 Pilot Light 30mm, Amber 120v PL10611 Lamp, Pilot Light 120v PL10236-120 Photoelectric Subassembly 120v PL10039 Clamp Band PL10236-230 Photoelectric Subassembly 230v PL10692 Flasher Module 120v PL10237 Photoelectric Socket PL10692-1 Flasher Module 230v * NSN 6220-01-536-1611 ** NSN 6220-01-536-1606 *** NSN 6250-01-536-1597 WEIGHT, DIMENSIONS & SHIPPING DATA inches (mm) Multi-Pack Carton Weight Height Width Depth Qty Weight Dim (inches) Standard Single: 3 lbs 1.4 kg 8.4 (214) 5.0 (127) 5.0 (127) 32 99 lbs 45 kg 22 x 22 x 22 POINTSPEC Single: 7 lbs 3.2 kg 13.9 (353) 6.0 (152) 5.0 (127) 9 66 lbs 30 kg 18 x 18 x 18 POINTSPEC Double: 10 lbs 4.5 kg 13.3 (338) 14.9 (378) 5.0 (127) 3 39 lbs 18 kg 18 x 18 x 19 Wind Loading: Effective Projected Area (EPA) for POINTSPEC Double 0.69 square feet P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 06070 Plant: West Dudley Town Rd, Bloomfield, CT Tel 01 860.243.0600 USA Fax 01 860.243.0665 email: Info@PointLighting.com website: www.pointlighting.com