THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

Similar documents
Thermometers Installation, Operation and Maintenance WINTERS INSTRUMENTS. MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

Blue Ribbon Corporation

B. Product Certificates: For each type of meter and gage, from manufacturer.

SECTION METERS AND GAGES FOR PLUMBING PIPING

A99B Series Temperature Sensors

SECTION METERS AND GAGES FOR HVAC PIPING

Mounting and Operating Instructions EB 2231 EN

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

. ECTION METERS AND GAGES

POWERS TM Controls HU 186 Room And Duct Hygrostats

PROJECT REFERENCE LIST

BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermometers Thermowells

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

CORALAIS BODYSPA BATH AND SHOWER FAUCET

1SC-SSC Splice Connection Kit Installation Instructions

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

OPERATION MANUAL MODEL & ACCELEROMETER

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Autocalibration Systems for In Situ Oxygen Analyzers

KOBOLD PSR/PS FLOW SWITCH

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

! WARNING. Before using product, read and understand instructions.

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

! WARNING. Before using product, read and understand instructions.

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

PROJ. NO SECTION METERS AND GAGES FOR HVAC PIPING

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

Installation Instructions

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

XT Series Thermostats

Series 1140 and 1141 Temperature Regulators

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

918 Clock Gauge Installation, Operation, and Maintenance Instructions

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

E.2 series high efficiency circulator. Installation and operating instructions

TECHNICAL INSTRUCTIONS

13-1. Temperature Regulator

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

Installation and operating instructions. E.2 Series high efficiency circulator

Installation of Glass Lined Equipment

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers

SOLARLOK Interconnection System Installation Manual

OPERATION MANUAL Model 8011 & mA

! WARNING. Before using product, read and understand instructions.

Powers TM Controls TH 188 Unit Mounted Thermostat

! WARNING. Before using product, read and understand instructions.

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Installation and Operating Instructions

Installation, Operation and Maintenance Instructions

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

VACUUM VALVES AND HOSES

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:


KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Fisher ENVIRO-SEAL Bellows Seal Bonnets

The Time & Temperature Company Company

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

OWNERS MANUAL FOR MEC 300E ATA

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

MINIATURE THERMOSTATIC VALVE

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

TECHNICAL INSTRUCTIONS

M7100 Pressure Transducer

INSTALLATION INSTRUCTIONS

TK-1001, 1101, 1201, 1301, 1601

TECHNICAL INSTRUCTIONS

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK

P/N CC-100. Coolant Circulator. Operation manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

MODEL 4000A & 4001A ACCELEROMETER

INSTALLATION INSTRUCTIONS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

ATTIAS MANUFACTURERS OF ATTIAS DOUGH MIXERS 265 BOWERY NEW YORK, N.Y TEL: (212) FAX: (212) COMMERCIAL DOUGH MIXERS

SKYL-TECH, INC. a world leader in validation technology. validation assemblies. thermocouples. feedthrus. consulting

FSW300 Series Flow Switch

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Experience In Motion. DEF Product Support Catalog

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

SECTION METERS AND GAGES

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Sprinkler Identification Numbers

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Transcription:

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

Bi-Metal Thermometers Bi-Metal Thermometers (TBM, TNR) Winters bi-metal thermometers are direct sensing instruments that are hermetically sealed and thus completely waterproof and dustproof. For accurate temperature readings, the stem should be immersed past the groove on the lower portion of the stem. All bi-metallic thermometers are of 304 stainless steel construction to protect against corrosive conditions. An external adjustment screw is conveniently located on the bottom of each case for easy field recalibration of thermometers, which may have shifted out of accuracy. Installation of Bi-Metal Thermometers Location Vibration and extreme ambient temperatures can affect the dial reading. These areas should be avoided as much as possible. Vibration effects can be minimized by the use of a dampening liquid such as glycerin or silicone. If vibration is extreme, then a remote reading filled thermometer should be considered. Mounting A suitable thread sealant is required for NPT threads such as pipe dope or Teflon tape. Never use any part of the thermometer other than the hex nut that is on the stem of the thermometer just above the NPT threads for installation. Always tighten with a wrench on the hex nut. Failure to do so will severely damage the thermometer. Typically, bimetal thermometers are connected to the process through a thermowell. This allows for the removal and testing, calibration or replacement of the instrument without affecting the process operations. The selection of thermowell material and stem lengths is critical in order to properly monitor the temperature of the process. Operation and Maintenance of Bi-Metal Thermometers Disassembly and Assembly / Spare Parts It is not recommended to disassemble the thermometer for any reason. If the thermometer is not functioning properly or if the lens is broken, the thermometer should be replaced. Please contact Winters for this. Inspection Frequency These thermometers are ruggedly constructed to give a reliable process temperature reading. The frequency of inspection is dependent on how critical the reading is at that point in the process. The inspection frequency can range from monthly to annual basis. Over Range Protection Over range protection allows the thermometer to function within its designed parameters even when the media temperature may intermittently exceed the thermometer range. The over range protection is 50% for ranges up to 500 F (260 C) and 10% above ranges of 500 F (260 C). Recalibration A master thermometer with a high degree of accuracy should be used for calibration. Immerse the bi-metal thermometer along side the master thermometer into an agitated liquid for at least three minutes and compare temperature readout. Note that both thermometers must be immersed at the same level. An external adjustment screw is conveniently located on the bottom of the case for easy field calibration. Winters can recalibrate and provide test certification. Please contact us for more details. Storage Store in a dry area at ambient temperatures not exceeding the indicator range. For example, if the indicator range is 0 C to 300 C, then the storage temperature should not exceed 300 C. Teflon is a registered trademark of DuPont Corporation 2 Tel: 1-800-WINTERS / www.winters.com

Bi-Metal Thermometers Head Rotation NOTE: The bi-metal thermometer head can be rotated as illustrated only when in back connection position. Never rotate the thermometer head when it is in the angled position. A To rotate thermometer head up to 360, make certain thermometer is in back connected position. Loosen two screws on both sides (A) until harness revolves freely. Now hold thermometer head and adjustable harness and rotate head to desired position. Retighten screws (A). Angle Positioning B To tilt thermometer head up to a 90 angle or straighten it, loosen single screw (B) by 1 /2 turn only. B Tilt to desired angle or straighten. Retighten screw (B). Tel: 1-800-WINTERS / www.winters.com 3

Liquid-in-glass Thermometers Liquid-in-glass Thermometers (TAG, TAS, TIM, TSW) Liquid-in-glass thermometers have a glass tube in front of a metal scale. It extends into a metal chamber and has a glass bulb attached. This tube is completely sealed and the bulb contains a predetermined amount of liquid which, on expanding and contracting caused by temperature changes, will indicate the temperature for a given temperature range. Installation of Liquid-in-glass Thermometers NOTE: Make sure that while connecting the thermometer to the process, the sensitive portion of its stem (the last 2½ from the end) is located well within the flow of the medium being measured for temperature. This will ensure accurate readings with minimal response time. 2 ½ minimum immersion Accuracy Inaccuracy may be caused by a broken tube, scale shifting in slots from original position, liquid separation, sensitive bulb not fully immersed in the media, or by poor circulation. Poor circulation can be explained as follows: If there is poor agitation in a fluid, the temperature stratifies or has hot or cold spots. The thermometer will read only the temperature in which the sensitive bulb is immersed. It is, therefore, important to locate on installation the sensitive bulb in the correct position. Corrosion The use of separate sockets of special material is recommended for corrosive or highly abrasive service. Location Care should be taken to locate the instrument on the equipment where vibration is at a minimum. Thermowell Connection Remove the thermowell from the thermometer if supplied with it. Install this thermowell in the pipeline or service as required. Insert the stem of the thermometer through the thermowell. Position thermometer for best reading position and tighten down. If the thermowells are purchased separately from the thermometers, then a suitable temperature transfer medium must be added to the well to properly conduct the temperature to the thermometer bulb. A mixture of graphite and oil, heat transfer paste, or even a light oil will suffice. Union Bushing (Hub) Connection Remove the union bushing from the thermometer if supplied with it. Install this union bushing in the pipeline or service as required. Insert the stem of the thermometer through the union bushing hole, engaging stem coupling nut with union bushing threads. Position thermometer for best reading position and tighten down coupling nut. 4 Tel: 1-800-WINTERS / www.winters.com

Liquid-in-glass Thermometers Liquid-in-glass Separation All liquid-in-glass thermometers are subject to separation of the liquid column. When this occurs, the thermometer will not read correctly. Some ranges and types are more readily susceptible to separation than others. Causes of Separation 1. Rough handling in shipment causes most separations. If the thermometer is given a sudden jar, the weight of the liquid column in the bore has sufficient inertia to separate the column. 2. If the thermometer with an expansion chamber at the top of the tube (away from the bulb) is accidentally overheated, some of the liquid is driven into the expansion chamber. As the thermometer later cools, the liquid column recedes towards the bulb. If the thermometer is left in a horizontal or inverted position while cooling, part of the liquid will remain in the expansion chamber. This would cause separation of the liquid column. How to Re-unite Separated Liquid Column When the reservoir or expansion chamber is at top of the tube (away from the bulb) / ranges below 550 F Heat the bulb of the thermometer slowly, observing the rise of the liquid in the tube. The point of separation should be driven into the expansion chamber. Take care that the chamber never becomes completely filled or the internal pressure will cause the tube to break. After the separation enters the expansion chamber, put the thermometer in an upright position. Give the tube a slight jar so that the particles of entrapped gas will rise above the liquid. When the liquid recedes, the column will be joined. When there is no reservoir at the top of the tube / ranges above 550 F Put the thermometer bulb in dry ice, so as to draw all the liquid into the tube. Tap the bulb gently on a hard surface with the thermometer held in an upright position, bringing the liquid together. When gradual heat is applied and the liquid rises, the column will be joined. Scale Rotation Grasp connection end firmly. Rotate locking nut by hand. Vari-angle Adjustment A A Loosen single screw (A). Tilt to desired angle. Tighten screw (A) to secure the angle. Tel: 1-800-WINTERS / www.winters.com 5

Remote Reading Thermometers Remote Reading Thermometers (THR, TRR) Remote reading thermometers are instruments used to measure temperature from a remote source. By means of a capillary tube with a sensing probe at one end and an indicating dial on the other, temperatures can be determined from a source that is up to 30 (100 m) away. Remote reading thermometers are filled with either gas or vapour depending on the specification. As temperature changes, the gas or vapour expands/contracts, creating pressure that is measured by a bourdon tube. Installation of Remote Reading Thermometers Accuracy The thermometer will read only the temperature in which the sensitive bulb is immersed. It is important to place at least 2 ½ of the sensitive bulb in the media to ensure reading accuracy. 2 ½ minimum immersion Corrosion The use of separate sockets of special material is recommended for corrosive or highly abrasive service. Capillaries are available in copper braided and stainless steel (with or without flexible armor), in an assortment of lengths. Winters recommends using a stainless steel bulb and capillary for all process temperatu res above 500 F (260 C). Location These thermometers offer the advantage of taking temperature readings away from locations that have heavy vibration or are possibly dangerous. Each thermometer with a front or back flange will have three mounting holes for securing the thermometer to a panel. Alternatively, u-clamps are available. Thermowell Connection Remove the thermowell from the thermometer if supplied with it. Install this thermowell in the pipeline or service as required. Insert the stem of the thermometer through the thermowell. Position thermometer for best reading position and tighten down. If the thermowells are purchased separately from the thermometers, then a suitable temperature transfer medium must be added to the well to properly conduct the temperature to the thermometer bulb. A mixture of graphite and oil, heat transfer paste, or even a light oil will suffice. Union Bushing (Hub) Connection Remove the union bushing from the thermometer if supplied with it. Install this union bushing in the pipeline or service as required. Insert the stem of the thermometer through the union bushing hole, engaging stem coupling nut with union bushing threads. Position thermometer for best reading position and tighten down coupling nut. 6 Tel: 1-800-WINTERS / www.winters.com

10 Remote Reading Thermometers Gas-filled Thermometers Gas-filled thermometers are designed for industrial applications requiring accurate and uniform response over the entire range. The entire system is filled under pressure with inert gas for positive movement, accuracy and sensitivity. The accuracy delivered by this system is +/-0.5% of the full scale value. We recommend the operating temperature range fall in the upper half of the dial. 40 50 60 Optimal operating temperature range 20 30 80 60 100 120 140 160 180 70 80 0-7 40 20 www.winters.com 220 F 200 C 100 90 Vapour-filled Thermometers Vapour-filled thermometers have non-linear scales (non-equal graduations across the entire scale). To ensure exceptionally close readings, the operating temperature should fall in the 2 /3 of the scale. The accuracy delivered by this system is +/-2% of the full scale value. Optimal operating temperature range 30 50 70 60 150 120 80 20 0 80 180 220 F 200 90 C 100 www.winters.com 7 Tel: 1-800-WINTERS / www.winters.com

MANUFACTURER OF INDUSTRIAL INSTRUMENTATION is a global manufacturer of premium quality pressure and temperature instrumentation, with distribution partners in over 90 countries. Please contact us for your nearest Regional Manager. Corporate 121 Railside Road Toronto, Ontario M3A 1B2 Tel: 416-444-2345 1-800-WINTERS Fax: 416-444-8979 sales@winters.com Asia - Shanghai Shanghai WitHub Hi-Tech Business Center Suite 308 No. 333 Hongqiao Road Shanghai 200030 China Tel: 86-21-6104-2610 Fax: 86-21-6104-2615 asiasales@winters.com www.wintersasia.com Canada - Calgary 3125-16 Street NE Calgary, Alberta T2E 7K8 Tel: 403-723-6645 1-800-WINTERS Fax: 403-723-6647 calgary@winters.com Asia - Beijing Rm. 1403, No. 36 Longbao Building, Maizidian Street Chaoyang District Beijing 100125 China Tel: 86-10-8773-1315 Fax: 86-10-8773-1315 asiasales@winters.com www.wintersasia.com USA - Buffalo 455 Cayuga Rd., Suite 650 Buffalo, New York 14225 Tel: 716-874-8700 Fax: 716-874-8800 1-800-WINTERS usasales@winters.com Latin America Albarellos 1916 1 Piso E1 B1640BIN, Martinez Buenos Aires, Argentina Tel: 54-11-4733-3003 Fax: 54-11-4733-0572 latinsales@winters.com www.winters.com.ar USA - Houston 5400 W. Sam Houston Parkway N. Houston, Texas 77041 Tel: 281-880-8607 1-800-WINTERS Fax: 281-880-8614 usasales@winters.com Middle East - North Africa 6WBB G50 Dubai Airport Free Zone Dubai, United Arab Emirates Tel: 971-4295-9177 Fax: 971-4295-9177 menasales@winters.com Distributed by: Download Winters literature at www.winters.com is ISO 9001:2008 Registered 11/16