SEE DISCLAIMER ON REVERSE

Similar documents
HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

safety & regulatory information

Ion Gateway Cellular Gateway and Wireless Sensors

TEC210x-2 Series Networked Thermostats

TEC2100 Series Networked Thermostats

Long Range Radio Alarm Transmitter

Installation Instructions

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

PIR Sensor. User s Guide

PRODUCT DIAGRAM PACKAGE CONTENTS

PRODUCT DIAGRAM PACKAGE CONTENTS

Owner s Manual. PIR-1 IR Learner

ADT. Pulse 2017ADT LLC

1126 Series Ceiling Mount PIR Motion Detector

Installation Instructions

RMS/RPX Reader. User Manual

Long Range Radio Alarm Transmitter

SZ-PIR04N ZigBee Motion Detector Installation Guide

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Door/Window Sensor Installation Instructions

Optima ZigBee Thermostat

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Installer Guide smart connect

Wireless High Bay Sensor (WHS100) Installation Instructions

3M Benchtop Air Ionizer 963E. User s Guide

6 Sheet Strip-Cut Shredder for Home/Office

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

FTP-1000 Touchpad/Display Installation Manual

Installer Guide smart connect

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

TEC1100 Series Thermostats

F261 Series Fluid Flow Switches

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Towel Warmer MAKE EVERYDAY A SPA DAY

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Performance Thermal Binder

2017 EcoFactor, Inc.

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Projection Alarm Clock USER GUIDE

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Wireless Thermostat (WTS10) Keypad Operation Guide

Disclaimer. Trademarks. Copyright. Warranty

75 Sheet Micro-Cut Shredder With CD/DVD Slot

CONNEX Smart Thermostat CST R00

WatchDog Wireless Crop Monitor Operation Manual

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

ADC-T2000. Smart Thermostat v1.5

Wireless Home Appliance Timer Remote Control Kit

Wireless Outdoor Air Reset Adaptor PN:

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

POWERED ANODE SYSTEM

HSD-200Z Z-Wave Motion Sensor

External Wireless Sounder

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

SC-6 Six Supervised Control Module

Pet Immune SAW PIR Motion Sensor

EW 40 Wireless Fan Control

9000P Wireless Alarm Owner s Manual

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Network Camera. Quick Guide DC-T1233WHX. Powered by

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

4100U City and Relay Cards Installation Instructions

Homeowner s Installation Instructions & Operating Manual

Towel Warmer. Luxurious warmth for towels, robes and blankets

Responder IV Wireless Bed Interface User s Guide

P266 Series Single-Phase Condenser Fan Speed Control

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Home Doorway Alert Kit

1100D Wireless Receiver

GT-1D. Residential/Tenant Station OPERATION MANUAL

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Twin Bell Digital Clock

Wireless Driveway and Intruder Alert

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Universal Fan and Light Remote Control

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Smart Hub THERMOSTAT. Installation Manual

Safety Instructions. Be sure to observe the following instructions when using the device.

Thermometer model 02059

Transcription:

BOLTEK CORPORATION Lightning Detection GSM-1 Text Message Notification for EFM-100C Electric Field Monitor User Guide SEE DISCLAIMER ON REVERSE

BOLTEK LIGHTNING DETECTION GSM-1 Text Message Alert Dialer Disclaimer Lightning data is only approximate and should not be used for safety applications. Strike and storm locations indicated and alarm statuses may be erroneous and should not be used to safeguard personnel, equipment or data. Neither Boltek Corporation nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of use, misuse, accident, or abuse. Notwithstanding the above Boltek Corp s liability shall not exceed the purchase price of the equipment. THIS EQUIPMENT IS NOT TO BE USED FOR SAFETY PURPOSES 2017 Boltek Corporation Boltek Corporation 4 Stonebridge Dr. Unit 2 Port Colborne, ON L3K5V5 Canada Email: info@boltek.com Web: www.boltek.com Phone (905) 734-8045 Fax (905) 734-9049

FCC Compliance Statement For United States Users This equipment is tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio and television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures. Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. WARNING The connection of a non-shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment. It is the responsibility of the user to use a shielded interface cable with this device. If this equipment has more than one interface connector, do not leave cables connected to unused interfaces. Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment. For Canadian Users This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la class B respecte toutes les exigences du Règlement sur le materiel brouilleur du Canada. WARNING: LIGHTNING AND ELECTRIC FIELD DATA IS ONLY APPROXIMATE AND SHOULD NOT BE USED FOR SAFETY APPLICATIONS. ELECTRIC FIELD READINGS, STRIKE DISTANCES AND ALARM STATUSES MAY BE ERRONEOUS AND SHOULD NOT BE USED AS A PRIMARY MEANS TO SAFEGUARD PERSONS, EQUIPMENT OR DATA.

Table of Contents Introduction... 1 Installing SIM Card... 2 Setup Instructions... 3 Dialer Configuration... 4 Adding Numbers... 4 Alert Messages... 5 Specifications... 6 GSM-1 Hardware Specifications... 6

CHAPTER 1 - SETUP Chapter 1 Introduction T he GSM-1 Text Message Dialer provides automatic text message notification as lightning activity approaches. Your GSM-1 package should contain: 1 GSM Cellular Dialer (with cellular antenna) 1 ERL-10 Programmable Output Relay Module 1 EPM-1 Power Module or EFA-21 Power/Data Module 1 AC wall adapter, 120VAC to 12VDC for North America/Japan Or 120V/220V AC to 12VDC Universal Power Adapter 1 External cellular antenna 1 Enclosure (Rated IP68) 1 USB Flash Drive with Windows software and Drivers 1 User Manual Unpack your GSM-1 and check that all parts are included. 1

CHAPTER 1 - SETUP Installing SIM Card 1) Detach GSM-1 from the DIN Rail by pushing up then pull top towards you then pull off the rail. 2) Remove the four screws on the back of the GSM-1 using No.1 Philips screwdriver 3) Insert SIM card with contacts facing down and angled corner to the top. 4) Reattach GSM-1 case with the four screws and place back on the DIN Rail 2

CHAPTER 1 - SETUP Setup Instructions 1) Install EFM-100 (and LD-250 if purchased). Please refer to user manuals of each detector for installation details. 2) Connect EFM-100 Cat5e cable to EPM-1/EFA-21 RJ45 connector. 3) Connect (optional) DB9 cable from LD-250 to ERL-10 RS232 connector 4) Connect the USB cable from your computer USB port to the USB connector of your ERL-10. 5) Plug in the AC power adapter into the lead of the EPM-1 and into an AC outlet. The EFM-100, ERL-10 and GSM Dialer will all power up. All of the LEDs on the ERL-10 will illuminate the indicator lights for 2 seconds then the EFM Data LED will start blinking. If the fault LED stays on, check EFM-100 power and connection or refer to Fault Code chart listed in Appendix A 6) After the ERL-10 is powered up, the USB drivers should automatically install if there is an active internet connection on the computer. If there is no internet connection, the USB driver install program can be found on the Boltek USB Flash Drive in the ERL-10 folder. 7) Run the ERL-10 program executable on the USB Flash Drive to install the Configuration, Monitor, and Data Viewer applications. 8) After installation has completed, run the Config application to set alarm parameters and click Write config to ERL-10 to save settings to the ERL-10. Note: The GSM-1 only works with the Yellow and Red alarm, the All Clear, and the Fault relays. 9) If viewing alarm status on a PC or Laptop, run the Status Monitor software to view active alarms/all clear status. Unless changed, once the ERL-10 is powered up, it goes into Survey Mode for a default time of 20 minutes. If no lightning activity is detected, then the All Clear status light will illuminate and normal operation of the device will begin. 3

CONFIGURATION Chapter 2 Dialer Configuration Adding Numbers All of the numbers can be stored by sending text message commands to the GSM-1 dialer. The commands are not case sensitive, so any case can be used when sending commands. In order to add text numbers, at least one Master number needs to be setup first before adding other numbers. The command for adding a Master number is Master<space>number. Ex: Master 15551234567. To add a text number to the GSM-1, use the command Textnum<space>number. This is independent from the master number, so it will also need to be added as a separate Text number by using this command as well to receive the text message alerts. Ex: Textnum 15551234567. To remove a number from the dialer, use the command Remove<space>number. sent from a master number that is stored in the dialer. Ex: Remove 15551234567 To view a list of the numbers stored on the dialer, use the command List M beside the number will indicate it is a master number T beside the number will indicate it is a text number. 4

CONFIGURATION Alert Messages The messages listed in the table below have all ready been pre-programmed into the dialer: Status Message Modify Command All Clear ALL CLEAR CUSTOMCL Fault Clear EFM FAULT CLEAR CUSTOMDL Fault Active EFM FAULT CUSTOMDH Red Alarm Active WARN CUSTOMAL Red Alarm Clear WARN CLEAR CUSTOMAH Yellow Alarm Active CAUTION CUSTOMBL Yellow Alarm Clear CAUTION CLEAR CUSTOMBH To change the message, send the modify command listed with the corresponding status followed by the message and a full stop. To customize an alert message, send the following command: CUSTOM<A/B/C/D><L/H><space><message>. Ex: CUSTOMAL RED ALARM IS ACTIVE. The maximum length of the message is 127 characters and must end with a full stop. Use only text or number characters in the message, and do not place a full stop in the middle of the message as the rest of characters after the first full stop will be ignored. 5

SPECIFICATIONS Appendix A Specifications GSM-1 Hardware Specifications Power Supply Voltage: GSM-1 Dimensions: GSM-1 Weight: Enclosure Dimensions: Enclosure Weight: (With GSM-1, ERL-10, EPM-1) 11.8-18 VDC, 0.8 Amp 5 3/8 " x 2 3/8 " x 1 1/4 " (135 x 60 x 30 mm) 0.2 lbs (100 gm) 12 1/2 " x 12" x 6" (318 x 305 x 152 mm) 5.0 lbs (2.26kg) Software Specifications Operating Systems: Alarm Distance Ranges: (non Coincidence mode) Alarm Distance Ranges: (Coincidence mode): High Field Alarm Ranges: Windows 10, 8, 7, Vista (32/64 bit), 2000, XP, 98, 95 0 to 20 mi (0 to 32 km) 0 to 40 mi (0 to 64 km) 0 to 20 kv/m 6

Notes 7