Interfacing LutronR RadioRAR Systems with Honeywell Vista-8BPT Security Systems Application Note #5 Revision B June 0 RadioRAR systems are capable of direct integration with the Honeywell Vista-8BPT security panel. Integrating a RadioRAR system with a security system enables many new features beyond intrusion alert. By incorporating lighting control, shades, temperature, and small appliance control, RadioRAR systems offer energy savings, convenience, and ambiance that the homeowner can enjoy every day. Required Components In order to interface a RadioRAR system with a Honeywell Vista-8BPT security panel, you will need the following items: RadioRAR system installed RadioRAR programming software version 5.0 or higher Honeywell Vista-8BPT security panel installed and programmed - To enable the extra settings that allow integration (not covered in the Honeywell instructions) see Programming step (page ) of this document. Null m Serial Cable or Null m Adapter with a Straight-through Serial Cable General understanding of RadioRAR systems and Honeywell Vista-8BPT security panels Recommended Components VT-SERCBL Cable Technical Support 800.5.966
Programming RadioRA systems to Interface with Honeywell Vista Security Panels Programming a RadioRAR system to interface with a Honeywell Vista-8BPT security panel is done in five steps:. Install and program the Honeywell Vista-8BPT security system according to the Honeywell instructions.. Program the Honeywell Vista-8BPT security system to enable the extra settings to allow the integration, not covered in the Honeywell instructions: - Serial Programming Options for Automation Applications in the Honeywell Vista-8BPT security panel Note: The following group of fields must be set to the serial port for automation applications: *05 Enter to send System Event Messages via RS port * Enter to enable Home/Facility Automation Control Input Enter *9 to change to the next page of program fields *70 Event Log Types (Enter in each event log type, there are 5 types) *78 Extended Home Control Events (Enter for extended) *79 Home Control Event Types (Enter in each home control event type, there are 5 types) *80 Enter to send zone fault/restore messages to the RS output.. Install and program the LutronR RadioRAR system using RadioRAR programming software version 5.0 or higher.. Program appropriate phantom buttons associated with each security action, as described in the following section. 5. Wire the Honeywell Vista-8BPT security panel to the RadioRAR Main Repeater using the instructions on page 0. Programming Phantom Buttons for Security Actions in the security system will send RS commands to the RadioRAR system. Each command is associated with a specific phantom button, and each phantom button may be programmed to deliver a desired. When a command is received from the security system, the corresponding phantom button is automatically pressed. For certain buttons, a Time of Day feature has been pre-programmed so that the most appropriate action takes place. The RadioRAR Main Repeater has 00 phantom buttons available for with integration. Buttons 76-00 are configured to receive commands from the Honeywell Vista-8BPT security system. Security Actions and Associated Phantom Buttons (Partition ) This table illustrates the various possible actions from a Honeywell Vista-8BPT security system and the phantom buttons that will be activated depending on the Time of Day. The recommended phantom button name is also matched to the phantom button number. Security Action Time of Day Phantom Button(s) Activated Phantom Button Scene Name(s)* Arm Away Day 95 and 9 + Away Timeclock Night 95 and 9 + Away Timeclock Arm Stay Day Night 9 Goodnight Disarm Day 9 turned off (Away Timeclock turned off) Night 9 turned off; 9 (Away Timeclock turned off); Welcome Intrusion Day 98 and 99 Exterior Flash, Interior Full Night 98 and 99 Exterior Flash, Interior Full Emergency Day 00 and 98 Emergency, Exterior Flash Night 00 and 98 Emergency, Exterior Flash www.lutron.com
Phantom Buttons and Recommended Programming This table provides the recommended programming for each phantom button associated with security on the Main Repeater. The Time of Day, when various actions will take place, is also specified. Phantom Button Security System Partition Button Type Recommended Scene Recommended Programming Shades HVAC Plug-in Modules Time Clock 00 All Single/Multiroom Emergency 99 All Security Interior Full 98 All Security Exterior Flash 97 All Reserved for future 96 All Reserved for future 95 Single/Multiroom 9 Single/Multiroom 9 Single/Multiroom 9 Timeclock Welcome Goodnight Away Timeclock 9 Reserved for future 90 Single/Multiroom 89 Single/Multiroom 88 Single/Multiroom 87 Timeclock Welcome Goodnight Away Timeclock 86 Reserved for future Interior lights at 5% Open Interior lights Open at 00% Exterior lights flash off (delayed off on exit pathway) Entry, foyer, kitchen lights on to 75% Evening light levels Close Close Set Set Away off (delayed off on exit pathway) Entry, foyer, kitchen lights on to 75% Evening light levels Close Close Set Set Away (continued on next page) Technical Support 800.5.966
Phantom Buttons and Recommended Programming (continued) Phantom Button Security System Partition Button Type Recommended Scene Recommended Programming Shades HVAC Plug-in Modules Time Clock 85 Single/Multiroom 8 Single/Multiroom 8 Single/Multiroom 8 Timeclock Welcome Goodnight Away Timeclock 8 Reserved for future 80 Single/Multiroom 79 Single/Multiroom 78 Single/Multiroom 77 Timeclock Welcome Goodnight Away Timeclock 76 Reserved for future off (delayed off on exit pathway) Entry, foyer, kitchen lights on to 75% Evening light levels Close Close Set Set Away off (delayed off on exit pathway) Entry, foyer, kitchen lights on to 75% Evening light levels Close Close Set Set Away www.lutron.com
Security Programming Timelines When configured according to this application note, the RadioRAR system will automatically respond to commands from the security keypad as outlined in the tables below. Key Arm Action Initiated Disarm Action Initiated Bold Active Events Gray Inactive Events RadioRA Action Daytime + hr Security Interior Full Security Exterior Flash Welcome Scene INTRUSION ALARM DISARM (Nighttime Welcome Scene) Sunrise Daytime + hr + hr 6 PM 7 PM 8 PM 9 PM 0 PM PM 6 AM 7 AM Interior Cancel Full on Full Exterior Flash Cancel Flash and Entry Overnight Arm Stay and Disarm Example RadioRA Action Daytime + hr Normal Time Clock Away Time Clock Goodnight Scene Welcome Scene + hr + hr Overnight Sunrise Daytime 6 PM 7 PM 8 PM 9 PM 0 PM PM 6 AM 7 AM, Foyer Kitchen ARM STAY (Nighttime Goodnight Scene) Bedroom Evening lighting T-stat adjusted; Shades lowered, Plug-in appliance modules Kitchen Dim Dim, Bedroom, Foyer Dim (nightlight), Foyer DISARM (Daytime No Action) (continued on next page) 5 Technical Support 800.5.966
Security Programming Timelines (continued) Arm Away and Disarm Example Key Arm Action Initiated Disarm Action Initiated Bold Active Events Gray Inactive Events RadioRA Action Daytime + hr Normal Time Clock Away Time Clock Welcome Scene Goodnight Scene ARM AWAY DISARM (Nighttime Welcome Scene) Sunrise + hr + hr PM 5 PM 7 PM 8 PM 9 PM 0 PM PM 6 AM T-stat set back Inside (0 min delay on exit pathway) Shades lowered, Plug-in modules, Foyer Kitchen Bedroom and Entry Kitchen Dim Dim, Bedroom, Foyer Dim (nightlight) Overnight, Foyer Note: if the Honeywell Vista-8BPT system has no partitions, phantom buttons associated with partition. See Phantom Buttons and Recommended Programming (page ) for the phantom button to partition mapping. 6 www.lutron.com
Programming the Phantom Buttons For more in-depth programming instructions, a corresponding Security Training Module can be found online at http://resi.lutron.com/radiora by following the RadioRAR Software line Training Modules link. ce the project has been designed in the RadioRAR programming software,. Select the Program tab.. Find the Main Repeater using the Selected Device Location drop-down menu. (continued on next page) 7 Technical Support 800.5.966
Programming the Phantom Buttons (continued). Select the desired button from the Phantom Button drop-down menu. (continued on next page) 8 www.lutron.com
Programming the Phantom Buttons (continued). Choose the appropriate Selected Button Type. 5. Program Devices and Levels. - Repeat steps -5 to program any remaining buttons Note: You must also complete the activation and transfer steps for the programming to take effect. 5 9 Technical Support 800.5.966
Application Note #5 Wiring Wire the Honeywell Vista-8BPT security panel to the RadioRAR Main Repeater using one of the following methods: Recommended Option:. P urchase the VT-SERCBL cable, which adapts the 0-pin header (J9) on the Honeywell Vista-8BPT security panel to a standard DE9M serial connector. Attached to (J9) 0-Pin header on the Honeywell VISTA-8 BPT panel USB Main Repeater Repeater Status M Communication RF Setup Wired Test COM MUX MUX 9V N/C Power Repeater Link Add Integrate RadioRA Main Repeater Program / Integrate Ethernet RS VT-SERCBL Cable 9V Ethernet RS RS85 Null m Adapter NULL MODEM Honeywell VISTA-8 BPT Security System Straight-through Serial Cable OR Alternate Option:. C onnect serial cable wires #, #, and #5 directly to the terminal block (TB) on the Honeywell Vista-8BPT circuit board. USB Main Repeater Repeater Status M Communication RF Setup Wired Test Add Integrate TxD T x D - Pin RxD R x D - Pin DTR No Connect DSR No Connect GND GND - Pin 5 Honeywell VISTA-8 BPT Security System COM Main Repeater MUX Vista 8BPT MUX 9V N/C Power Repeater Link 9V RadioRA Main Repeater Program / Integrate Ethernet RS Ethernet RS RS85 6 7 8 9 5 RS Pin # TxD RxD GND 5 Note: N ormally RS connections would be wired with TXD connected to RXD. In this case TXD is wired to TXD and RXD to RXD so that a Null m adapter is not needed. 0 www.lutron.com
Lutron, ) and RadioRA are registered trademarks and RadioRA is a trademark of Lutron Electronics Co., Inc. 0 Lutron Electronics Co., Inc. Lutron Contact Numbers WORLD HEADQUARTERS USA Lutron Electronics Co., Inc. 700 Suter Road Coopersburg, PA 806-99 TEL: +.60.8.800 FAX: +.60.8. Toll-Free:.888.LUTRON Technical Support:.800.5.966 intsales@lutron.com North & South America Technical Hotlines USA, Canada, Caribbean:.800.5.966 Mexico: +.888.5.90 Central/South America: +.60.8.670 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd. 6 Sovereign Close London, EW JF United Kingdom TEL: +.(0)0.770.0657 FAX: +.(0)0.780.6899 FREEPHONE (UK): 0800.8.07 Technical Support: +. (0)0.7680.8 lutronlondon@lutron.com ASIAN HEADQUARTERS Singapore Lutron GL Ltd. 5 Hoe Chiang Road #07-0, Tower 5 Singapore 0896 TEL: +65.60.666 FAX: +65.60. Technical Support: 800.0.9 lutronsea@lutron.com Asia Technical Hotlines Northern China: 0.800.7.56 Southern China: 0.800.0.56 Hong Kong: 800.90.89 Indonesia: 00.80.0.99 Japan: +8..5575.8 Macau: 0800.0 Taiwan: 00.80.7.77 Thailand: 00.800.0.66585 Other Countries: +65.60.666 Lutron Electronics Co., Inc. 700 Suter Road Coopersburg, PA 806-99 U.S.A. 06/0 P/N 085 Rev. B