FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Similar documents
This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FireNET Plus Wiring Instructions

FireNET Plus Analog Addressable Fire Alarm System Installation and Operation Manual

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FIRE ALARM SYSTEM. FireNET ANALOG ADDRESSABLE CONTROL PANEL. FireNET Plus ANALOG ADDRESSABLE CONTROL PANEL

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Cover Inside Front & Back

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

World Class Leaders in Fire Detection Since SYSTEMSCATALOGUE UL Fire Detection Systems

Intelligent Single Loop Fire Alarm Control Panel

Specification/ Data Sheet

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

LifeAlarm Fire Alarm Control Panels

PSN-1000 & PSN 1000(E) Installation Manual

Intelligent 2 & 4 Loop Fire Alarm Control Panels

CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM

PRODUCT BROCHURE THE WORLD S FINEST FIRE DETECTION SYSTEMS SINCE 1918 UNITED KINGDOM USA JAPAN MIDDLE EAST USA TAIWAN MEXICO INDIA THAILAND SINGAPORE

good things in small packages

ALK-V PHOTOELECTRIC SMOKE SENSOR

Addressable Fire Alarm Control Panel

Conventional Releasing Control Panel

DS7400Xi Addressable Control/ Communicator

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

DCP-FRCME - FAST RESPONSE CONTACT MODULE

30.45 Electric Release PDRP-2001

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

AND ARCHITECT SPECIFICATIONS

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA OBSOLETE

ECC-50/100C. Emergency Command Center

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

FIRE DETECTION SYSTEMS. Product Guide

FireNET Fire Alarm Control Panel Installation Manual

TrueAlarm Fire Alarm Systems

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Commercial and Light Industrial Fire Alarm Control Panel

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

AFC-1000 Fire Alarm Installation Manual

4007ES Fire Control Panels

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

INTELLIGENT FIRE ALARM CONTROL PANEL

Laptop / PC Programming Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

FIRE DETECTION SYSTEMS. Product Guide

NETWORK FIRE ALARM CONTROL PANEL. Features

Z-20 Fire Control Panels

Installation, Operating and Maintenance Manual

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

D7024 Fire Alarm Control Panel

Release Control Fire Alarm Systems

AL800ULADA. NAC Power Extender. Installation Guide

An introduction to... Sigma

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

ECC-50/100(E) Emergency Command Center

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FIRE DETECTION SYSTEMS. Product Guide

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

4007ES Fire Control Panels

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

MR-2602 Two Zone Fire Alarm Control Panel

Desigo TM Fire Safety System A comprehensive fire-protection system

TrueAlarm ES Analog Sensing

OPERATION AND INSTALLATION MANUAL

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Carbon Monoxide Transmitter

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

SALES SUPPORT DOCUMENT

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

PFC-4064 Conventional Fire Alarm Panel

Intelligent addressable fire alarm control panel

Reliably Advanced Extinguishing Control

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

AL600ULADA. NAC Power Extender. Installation Guide

CATALOG NUMBER. Features. Description

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Desigo TM Fire Safety System A comprehensive fire-protection system

LifeAlarm Fire Alarm Controls

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

4.1 Mounting the 5820 Cabinet Removing the 5820 Assembly from the Housing AC Connection Battery Connection...

4007ES Fire Control Panels

Multi-Point Peripherals

OPEN SPRINKLER SYSTEM

P/N Product Manual. Conventional Fire Alarm/Suppression System

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Transcription:

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL The FireNET 427 control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 27 devices of any combination (sensors or modules), and 27 analog sounder bases, for a possible total of 254 points. Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.25 amp power supply and has 4 on board NAC circuits. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC. The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity mode. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The Loop Explorer Windows Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto-learn feature offers the convenience for quick start applications. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value. UL 864 9th Edition Listed Seismic certified Analog design using Hochiki s advanced DCP protocol for fast and robust communication Up to 27 sensors & modules, plus 27 analog sounder bases, for a total of 254 points possible per loop Uses standard wire, no shielded or twisted pair required on SLC loops Supports Class B (style 4) and Class A (style 6 or 7) SLC loops 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps each Programmable sensitivity levels per device & automatic day/ night sensitivity modes Automatic daily calibration & drift compensation routine Large 8-line x 40-character LCD display (3 char.) 2 loop (FN-227 Series) or 4 loop (FN-427 Series) versions (800 addresses/sub-addr. max.) Dual RS-485 bus for panel network 2 built-in RS-232 interfaces for programming via a PC and serial printer interface 5 on board programmable Form C relays rated at amp at 30VDC (Fire, Fire2, trouble, supervisory, aux.) 500mA of auxiliary power available rated at 24 VDC Loop Explorer Windows configuration utility 500 network wide software zones Network capability of up to 64 panels RS485 slave bus for expansion - up to 32 FN-427-IO boards or up to 5 FN-LCD-S serial annunciators and up to 7 FN-427-IO boards Auto-learn feature Fire Drill test function Walk test function Alarm verification feature FireNET is UL listed for Central Station Service, Remote Station Service and Proprietary Service Operates on VAC or 240VAC input voltage Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including: *Cause & Effect action *Disable function configuration *Test mode configuration SIGNALING UL 864, Local Signaling Unit. Types: Automatic, manual, waterflow, sprinkler supervisory, Remote Station and Central Station Service (DACT) Non-coded signaling. S8255 NFPA 70, 72 &3 Compliant 765-040:59 303387 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F0068 03/5

Primary AC Output DC Power Supply Charger Current Dimensions Weight Color Material VAC @ 2. Amps 60hz or 2VAC @.Amps 50hz 24VDC @ 5.25 Amps (4 Amps availble for system power) 5.25 Amps integrated.5 Amps max. 4.5" W x 24" H x 5" D 3 lbs. (without batteries) Red (optional gray) ABS/steel enclosure Display 8 line x 40 character LCD (3 characters total) Network Dual RS485 ports (64 panels max.) Zones 500 network wide software zones per system SLC loops 2 or 4 (class A, "style 6 or 7" or class B, "style 4") Devices per loop 27 sensors & modules, plus 27 analog sounder bases, 254 total Addresses per panel (800 addresses+sub-addresses max. per panel) NAC Outputs (4) 2.5 Amps @ 24VDC (class B) Relay Outputs (5) Form C Amp @ 30VDC Voltage Outputs Aux. Power Aux. Inputs PC Port / Printer Operating Temp. Relative Humidity (3) 500mA @ 24VDC 500mA @ 24VDC (8) digital pull downs RS232 32 F (0 C) F (49 C) 85% RH Non-Condsensing SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES MODEL CONTROL PANEL EXPANDERS FN-427-SLC Dual SLC Loop Expansion Card FN-427-NIC Network Interface Card FN-427-IO 6 Channel Input/Output Board FN-DAC Digital Alarm Communicator FN-CTM City-Tie Module (Local Energy Type) ANNUNCIATOR FN-LCD-N Network LCD Annunciator FN-LCD-S Serial LCD Annunciator SLC LOOP DEVICES ALG-V, ALK-V, ALN-V Analog Addressable Photoelectric Sensor AIE-EA Analog Addressable Ionization Sensor ATG-EA, ATJ-EA Analog Addressable Heat Sensor ACA-V, ACC-V Multi-criteria Sensor NSA-4 & NSA-6 Four Inch Sensor Base and Six Inch Sensor Base SCI-B4 & SCI-B6 Four Inch Short Circuit Isolator Analog Sensor Base & Six Inch Circuit Isolator Analog Sensor Base ASB Analog Sounder Base ASBL Analog Low Frequency Sounder Base DH-98A, DH-98AR Analog Addressable Duct Detector Unit (DH-98AR and DH-99AR DH-99A, DH-99AR have relays built-in) MS-RA, MS-RA/R, MS-KA/R Remote Test Station for DH-98AR & DH-99AR DCP-FRCME-M Contact Monitoring Module (mini w/terminal blocks) DCP-FRCME-P Contact Monitoring Module (mini w/pigtail leads) DCP-FRCME-4 Contact Monitoring Module (with faceplate/indicating LED) DCP-FRCMA, DCP-FRCMA-I Class A Contact Monitoring Module (FRCMA-I has built-in SCI) DCP-DIMM Dual Input Monitor Module (with faceplate/indicating LED) DCP-CZM Conventional Zone Module DCP-R2M Dual Relay Module DCP-R2ML/H Series Dual Relay Module (R2ML-I & R2MH-I has built-in SCI) DCP-SOM Supervised Output Module DCP-SOM-A, DCP-SOM-AI Class A Supervised Output Module (SOM-AI has built-in SCI) DCP-SOM-R Supervised Output Module for Releasing Pre-action System DCP-SCI Short Circuit Isolator Module DCP-AMS Series Addressable Manual Pull Station ACCESSORIES TCH-B00 Hand Held Programmer (portable device addresser) FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries) FNP-ETR Enclosure Trim Ring for panel flush mount FireNET ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

FireNET Plus - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL The FireNET Plus 27 series control panel is an analog addressable fire alarm panel with build options containing or 2 SLC loops, a Digital Alarm Communicator/Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 27 devices of any combination (sensors or modules), and 27 analog sounder bases, for a possible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communication for peripheral devices. The RS-232 interface allows the convenience of programming via a PC. The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The Loop Explorer Windows Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn feature offers the convenience for quick start applications. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value. Analog design using Hochiki s advanced DCP protocol for fast communication Up to 27 sensors & modules, plus 27 analog sounder bases, for a total of 254 points possible per loop Uses standard wire, no-shielded or twisted pair required on SLC loops Integrated digital alarm communicator (DACT) with Contact ID and SIA reporting formats Programmable sensitivity levels by device Alarm verification feature Automatic daily calibration & drift compensation routine Large 8-line x 40-character LCD display (3 char.) or 2 loop (option) RS-485 bus for panel network (option) Built-in RS-232 interface for programming via a PC 3 on board programmable Form C relays rated at amp at 30VDC 2 auxiliary power outputs, each rated 360mA at 24 VDC Loop Explorer Windows configuration utility Auto-learn feature 500 network wide software zones Network capability of up to 64 panels (option) Built in help and alarm information screens 2 on-board Class B (style Y) NAC circuits rated at 2.3 amps each (special application) and.6 amps each (regulated continuous) Gentex, System Sensor, Wheelock, and Amseco NAC sync protocol built-in Automatic day/night sensitivity modes Fire Drill test function Walk test function Powerful & versatile Cause & Effect wizard including: *Cause & Effect action *Disable function configuration *Test mode configuration Seismic certified SIGNALING UL 864, Local Signaling Unit. Types: Automatic, manual, waterflow, sprinkler supervisory, Remote Station and Central Station Service (DACT) Non-coded signaling. S6468 NFPA 70, 72 &3 Compliant 765-040:80 303873 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F0087 03/5

Primary AC Output DC Power Supply Charger Current Dimensions Weight Color Material VAC @ 2. Amps 50/60hz or 2VAC @.Amps 50/60hz 24VDC @ 5.25 Amps 4 Amp integrated.25 Amps max. 4.5" W x 9" H x 3.5" D lbs. (without batteries) Red (optional gray) ABS/steel enclosure Display 8 line x 40 character LCD (3 characters total) Network Dual RS485 ports (64 panels max.) Zones 500 network wide software zones per system SLC loops or 2 (class A, "style 6 or 7" or class B, "style 4") Devices per loop 27 sensors & modules, plus 27 analog sounder bases, 254 total Addresses per panel 800 addresses+sub-addresses max. per panel NAC Outputs (2) class B, 2.3 Amps (special application).6 Amps Regulated (continuous) Relay Outputs (3) Form C Amp @ 30VDC Aux. Power 2 outputs, 360mA @ 24VDC each PC Port / Printer RS232 DACT Formats Contact ID and SIA FNP-27-SLC FN-427-NIC FN-427-IO FN-LCD-S FNP-LED MODEL ALG-V, ALK-V, ALN-V AIE-EA ATG-EA, ATJ-EA ACA-V, ACC-V NSA-4 & NSA-6 SCI-B4 & SCI-B6 ASB ASBL DH-98A, DH-98AR DH-99A, DH-99AR MS-RA, MS-RA/R, MS-KA/R DCP-FRCME-M DCP-FRCME-P DCP-FRCME-4 DCP-FRCMA, DCP-FRCMA-I DCP-DIMM DCP-CZM DCP-R2M DCP-R2ML/H Series DCP-SOM DCP-SOM-A, DCP-SOM-AI DCP-SOM-R DCP-SCI DCP-AMS Series TCH-B00 FN-ACC FNP-ETR SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES CONTROL PANEL EXPANDERS SLC One Loop Expansion Card Network Interface Card 6 Channel Input/Output Board ANNUNCIATOR Serial LCD Annunciator Graphix Display SLC LOOP DEVICES Analog Addressable Photoelectric Sensor Analog Addressable Ionization Sensor Analog Addressable Heat Sensor Multi-criteria Sensor Four Inch Sensor Base and Six Inch Sensor Base Four Inch Short Circuit Isolator Analog Sensor Base & Six Inch Circuit Isolator Analog Sensor Base Analog Sounder Base Analog Low Frequency Sounder Base Analog Addressable Duct Detector Unit (DH-98AR and DH-99AR have relays built-in) Remote Test Station for DH-98AR & DH-99AR Contact Monitoring Module (mini w/terminal blocks) Contact Monitoring Module (mini w/pigtail leads) Contact Monitoring Module (with faceplate/indicating LED) Class A Contact Monitoring Module (FRCMA-I has built-in SCI) Dual Input Monitor Module (with faceplate/indicating LED) Conventional Zone Module Dual Relay Module Dual Relay Module (R2ML-I & R2MH-I has built-in SCI) Supervised Output Module Class A Supervised Output Module (SOM-AI has built-in SCI) Supervised Output Module for Releasing Pre-action System Short Circuit Isolator Module Addressable Manual Pull Station ACCESSORIES Hand Held Programmer (portable device addresser) Battery/Accessory Enclosure (houses up to 33AH size batteries) Enclosure Trim Ring for panel flush mount FireNETPlus ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

FNP-LED - GRAPHIX LED DISPLAY Available in red and gray Available in 3 different size enclosures LED's comes in 3 different colors: red, green, or yellow FNP-LED can be easily upgraded onsite with minimal cost and effort The FNP-LED system uses flexible, optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added onsite without the need for any wiring. All indicators can be configured to operate upon any event type and at point, zone or group level via the powerful and intuitive Loop Explorer configuartion tool. The FNP-LED can be supplied with or without optional LED's and controls. Optional LED's indicate Power On, Fire, Trouble and Disablements and optional controls are for Alarm Silence, Buzzer Silence, Lamp Test, and Reset. Housed in an attractive, slimline enclosure to match FireNET Plus Fire Alarm Panels. High quality, full color floor plans provide a clear and geographical indication of event activation, which enables fast identification of the Fire Alarm source. Operating Voltage Maximum Current Wire Size Communication Method Max. Wiring Distance Avalible Dimensions Color Material Max. LED's Operation Temperature Cabinet Lock Type SIGNALING S5694 2-30VDC 360mA 2AWG to 22AWG RS485 3900ft. (0m) AM2: 4.50"W x 2.25"H x 3.50"D AM3: 4.50"W x 8.90"H x 4.25"D AM4: 4.50"W x 24.25"H x 4.25"D Red (optional gray) ABS/Steel Enclosure AM2: 40 LEDs AM3: 72 LEDs AM4: 88 LEDs F (-6 C) to F (49 C) CAT 30 Key 7-040:8 303873 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F002 03/5

HCVR-3 CONVENTIONAL RELEASING FIRE ALARM CONTROL PANEL The HCVR-3 is a 3 zone conventional releasing fire alarm control panel that is UL Listed and FM Approved for releasing. The HCVR-3 can be configured to activate releasing by a single zone or combination of any two zones. The LCD display is used to show the countdown timer during activation of the releasing sequence. The HCVR-3 is fully programmable using simple menu options. The panel is a single board construction which provides an easy replacement solution. It is also compatible with a wide range of devices. UL 864 Listed and FM Approved Three detection zones Any single zone or any combination of zones can be configured to release Fully programmable using simple menu options Simple, single board construction Installer friendly Compatible with wide range of detection devices Configurable first stage NAC delays Configurable detection delays Built-in Manual Release switch and separate circuit Compatible with FirePro Xtinguish Compatible with various releasing valves Configurable releasing delays up to 60 seconds in 5 second intervals Configurable releasing duration up to 5 minutes in 5 second intervals Releasing countdown timer displayed on the LCD Supports up to seven HCVR-SDU or HCVR-AB Built-in relays for Fire, Trouble, Stage, Stage 2, Extract and Local Fire SIGNALING S6468 765-040:06 3046396 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F054 04/5

Supply Voltage Power Supply DC Rating Mains Supply Fuse Dimensions Weight Color Material Max. Battery Size RS-485 Serial Bus Trouble Contact Rating Local Fire Contact Rating Fire Contact Rating st Stage Contact Rating 2nd Stage Contact Rating EXTING Contact Rating EXTING Contact Rating NAC Output Rating Detection Zone End of line resistor NAC Output Stand by Current Alarm Current Operating Humidity Operating Temperature 5VAC (50hz/60hz) or 230VAC (50hz/60hz) 24VDC 3 Amps total including battery charging.6 Amps 250VAC, slow-blow, 5 x mm 5.2" (385mm)W x 2.2" (30mm)H x 3.5" (90mm)D 2.3 lbs. Red or gray.2mm mild steel 7Ah 2V (2 per panel) Maximum line impedance Ohms 30VDC Amp 30VDC Amp 30VDC Amp 30VDC Amp 30VDC Amp 30 VDC Amp contacts for (NO) and (C) 8 to 28VDC Amp max load for 5 minutes and voltage reversing DC 0.5 Amp per output 6K8 Ohms 5% resistor 0K Ohms 5% resistor 86 ma 6 ma 93% (non condensing) -5 C to +40 C HOCHIKI AMERICA COMPATIBLE DEVICES MODEL MAX PANEL ACCESSORIES HCVR-SDU Remote Status Display Unit 7 HCVR-AB Ancillary Board 7 HCVR-SQA Sequential Activator HCVR-DS Disconnect Switch SLR-24H DETECTORS Photoelectric Smoke Detector w/heat SLR-835 Photoelectric 8-35V Smoke Detector SLR-835/-835W Photoelectric 8-35V Smoke Detector SLR-835-BH-2W Photoelectric 8-35V Smoke Detector w/heat SLV-24V/-24/-24N Photoelectric Smoke Detector SIJ-24 Ionization Smoke Detector DCD-35 35 Fixed Temperature Rate of Rise Heat Detector DCD-90 NS6-2 NS4-2 90 Fixed Temperature Rate of Rise Heat Detector BASES 6" base, 43mA draw, 24V 4" base, 43mA draw, 24V PULL STATION/ABORT SWITCH HPS-SAK/HPS-DAH/HPS-SAH/HPS-DAK Conventional Manual Pull Station HCVR-AS Abort Switch RELEASING VALVES HV285328 ASCO Solenoid 8G7 ASCO Solenoid 60 Viking Solenoid 602 Viking Solenoid 592 Viking Solenoid 59 Viking Solenoid 596 Viking Solenoid 595 Viking Solenoid 2823A-2NB-A4F6 Snap-tite Solenoid EA45 (50006) Sevo Systems Solenoid K-45-807 Kidde Solenoid (equivalent to 486500-0) B6793-859 Kidde Solenoid (equivalent to 8-00000-00) 753-E Series Victaulic Solenoid 305350 Ci IS8B Fire Eater Solenoid 30545 Ci IS8B Fire Eater Solenoid CONVENTIONAL FIRE ALARM CONTROL PANEL

HCVR-AS ABORT SWITCH UL Listed and FM Approved Capable of aborting releasing operation Available in red or gray Includes a back box for surface mount HCVR-AS is a single action push button abort switch. HCVR-AS is compatible with the HCVR-3 fire alarm control panel. HCVR-AS is connected via terminal block connections. Models Switch Rating Dimension HCVR-AS-R (red) HCVR-AS-G (gray) A @ 30VDC 3.8" W x 3.8" H x 2.32" D SIGNALING S6468 7300-040:07 3046396 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F055 04/5

HCVR-DS DISCONNECT SWITCH UL Listed and FM Approved Physical switch provides NFPA-compliant disconnect solution for releasing service Includes a back box for surface mount HCVR-DS is a disconnect switch used to disable a releaing circuit for system testing or maintenance. HCVR-DS is compatible with the HCVR-3 Conventional Releasing Fire Alarm Control Panel. Models Switch Rating Dimension HCVR-DS-R (red) HCVR-DS-G (gray) A @ 30VDC 3.8" W x 3.8" H x 2.32" D SIGNALING S5694 7300-040:07 3046396 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F097 04/5

HCVR-SQA SEQUENTIAL ACTIVATOR UL Listed and FM Approved Capable of releasing two aerosol generators or canisters Includes a back box for surface mount LED indicates for output supervision trouble HCVR-SQA is a sequential activator that is used to operate fixed condensed aerosol generators or canisters for extinguishing fire in a confined space. COMPATIBILITY LIST CANISTER TYPE FNX-00S FNX-0S FNX-500S FP-00S FP-0S FP-500S GENERATOR TYPE HOCHIKI AMERICA FNX-000 FNX-00 FNX-3000 FNX-5700 FIREPRO FP-000 FP-00 FP-3000 FP-5700 Models HCVR-SQA Supply Voltage 24VDC Average Current Consumption ma Maximum Output Current A @ 24VDC Material Mild Steel Dimension 3.58" W x 3.58" H x.6" D SIGNALING S6468 7300-040:07 3046396 705 Village Drive, Suite 00 Buena Park, CA 9062-2268 Phone: 74/522-2246 Fax: 74/522-2268 F067 04/5

WIRING DIAGRAM HCVR-SQA