Series 20 Dual Check Backflow Preventers

Similar documents
Flow Control for Fire Protection

Flow Control for Fire Protection

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Automatic Temperature Controller (ATC)

SECTION DOMESTIC WATER PIPING SPECIALTIES

A. This Section includes the following domestic water piping specialties:

VALVES SECTION 15100

SPEAKMAN SPEAKMAN SPECIFICATIONS

Plumbing Solutions for Agriculture and Irrigation Applications

10-MINUTE "EXPERT" dahl Edition

General System Layout Sketch

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

TABLE 1 Electrical Specifications

Thermostatic Radiator Valves (Caleffi)

2016 CASH ACME CATALOG

TABLE 1 Electrical Specifications. Phase

ASSE 1017 Point of Source Commercial. Mixing Valves. Mixing Valves. MVA (34A) Series/MVAH Hydronic Series

Engineering Specifications

Radiator Valve Program

Thermostatic mixing valves with replaceable cartridge for centralized systems

Settlement Agreement. Schedule 1: Covered Products

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

The BEST Plumbing Specialties. One Source. F 1 BRAIDED SUPPLIES

Thermostatic mixing valves with interchangeable cartridges

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

INSTANT-FLOW C-MICRO WATER HEATER

TECHNICAL. Series 18. Pump Packages

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

WATER CONTROL VALVES

INSTANT-FLOW C-MICRO WATER HEATER

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

F4060 RESILIENT SEATED GATE VALVES

UL/FM Fire Protection Products Setting the Standard

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

TANKER & STORAGE TANK PRODUCTS

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

UL/FM Fire Protection Products Setting the Standard

SECTION METERS AND GAGES FOR PLUMBING PIPING

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

BSHM ARCHITECTS, INC. 15 Central Square, Suite 300 Youngstown, Ohio 44503

CONNECTION SYSTEM JULY

Installation, commissioning and servicing instructions

Taco 00 Series Cartridge Circulators

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

CONNECTION SYSTEM AUGUST Reliance Worldwide USA

General System Layout Sketch

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

SHARKBITE CONNECTING SYSTEM

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Jabsco Marine Toilets SIMPLY RELIABLE SOLUTIONS FOR EVERY BOAT AND BUDGET

Product Specification

Home. One Source For All Your Potable Water Needs

Progressive Cavity Sewer Systems

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING

PRODUCTS THAT CONSERVE, REPAIR AND SAVE!

POULTRY MARKET CATALOG

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

4. Provide brass valve tags marked for the service. See pertinent service specification for valve type.

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

Residential Fire Meter

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

WAL-RICH CORPORATION SINCE 1950

SECTION HYDRONIC PIPING AND SPECIALTIES

TECHNICAL DATA OBSOLETE

1 Exam Prep. Questions and Answers

Installation. S Series Navigator Thermostatic Mixing Valve

C1N & C2N SERIES Fluid heating for light industrial applications

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

GE & PROFILE SmartWater Softener Systems

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Honeywell Water Solutions. Thermostatic Mixing Valves

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

freedom residential concealed pendent sprinkler VK488 (K3.0)

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

Unequaled I Unrivaled I Performance

Frequently Asked Questions

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

CESCO brass. The Power Behind The Throne

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

freedom residential concealed pendent lead free sprinkler

SENTRA Series Water Unit

HL SERIES Fluid heating for commercial applications

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

General System Layout Sketch

Viega Fire Protection Systems. Safety starts here

Transcription:

Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com

Protecting the Public Water Supply Both public water supply officials and consumers need to protect the public supply of safe drinking water. As a public water supply professional, you need to do everything in your power to prevent the reverse flow associated with: Main line flushing (maintenance) Firefighting (emergency) Main line rupture or blowout (disaster) Such activities and occurrences can siphon domestic water systems, drawing every conceivable fluid connected to the user s system back into the public water supply. Series 20 Backflow Preventers provide cost-effective backflow protection of the public water supply when used according to the local or state plumbing code requirements. As part of your comprehensive containment program, you should require the installation of a Series 20 unit as a condition for the user to receive service from the public water system. This three-step program should ideally include: The first line of defense The user certifies that his/her domestic water system complies with the local plumbing codes. The second line of defense The user installs a dual check backflow preventer at the water meter as prescribed by the supplier of safe drinking water. The third line of defense education The supplier of water provides educational material that teaches the user how to avoid contaminating or polluting the drinking water once it has entered his domestic water system. Series 20 Dual Check Backflow Preventers from Ames To ensure the safety of drinking water, there can be no room for compromise. That s why Ames provides the incomparable Series 20 Backflow Preventers with dual check security. Installed at the residential water meter or service entrance, Series 20 Backflow Preventers offer: Low pressure drop Easy maintenance and service Wide selection of types, sizes, and connections Our unique check modules put our Series 20 Backflow Preventers distinctly ahead of other residential containment devices. With their innovative design, most Series 20 models offer a full range of features, including: Chloramine resistance for long life under the harshest water conditions Complete modularity for easy maintenance Limit stops to prevent damage from thermal expansion Center and edge guides to ensure repeatable seating and minimize localized wear No exposed screws or threads to eliminate corrosion potential and improve serviceability Of course, Series 20 Dual Check Backflow Preventers embody the quality engineering of Ames, a world leader in valve technology. And you have the confidence of knowing the Series 20 are ASSE 024 Certified. So when you need to be sure you have the most reliable residential containment products, specify Ames Series 20 backflow preventers. Model/Series Features 20 L20 20S Cu20 Center Stem Guides Edge Guides Chloramine Resistant Components Modular Design Limit Stops Stainless Steel Springs Replaceable Seats No Exposed Screws Or Threads Chloramine Resistant Construction Center Stem Guide Edge Guides Series 20 Check Module Limit Stops Replaceable Seats Modular Design O-Ring Seals 2

Series 20 Dual Check Backflow Preventers Sizes: 2" 4" (5 2mm) Available with an extensive combination of inlet/outlet sizes, types of thread, and end connections including retrofit compression fittings and hose connections the Series 20 can be installed in a variety of piping configurations, and in conjunction with a wide range of meter horns, copper setters, and meter boxes. Description The straight line, poppet-type construction of the Series 20 minimizes pressure drop and provides smooth flow characteristics. It can be installed horizontally or vertically. It is not adversely affected by normal line pressure surges, will not cause water hammer, and operates without chatter or vibration. Standards Tested and certified to meet ANSI/ASSE Standard 024. Important: Inquire with governing authorities for local installation requirements. Specifications The dual check backflow preventer shall meet the domestic requirements of ANSI/ASSE Standard 024, and bear the seal of approval. It shall be bronze-bodied and include not less than one union, with the union nut drilled to accept a tamper-proofing lock wire. A brass identification tag indicating direction of flow shall be securely attached to the valve body by corrosionresistant mechanical fasteners. The dual check shall be an Ames Fire & Waterworks Series 20. (Please select the model best suited to your application.) Materials 024 Cast bronze body, durable plastic check modules, injection molded of acetyl resin and PPO, silicone discs and Buna N seals, stainless steel springs, one union and O-ring union seal. 0 5 8 2 62 9 4 6 2 0 5 69 0 5 5 ft. ± (.94m±) 2" (5mm) 4" (20mm) 0 5 0 5 20 25 0 5 gpm 9 8 57 76 95 4 lpm 0 ", 4" (25, 2mm) 5 0 5 20 25 0 5 gpm 9 8 57 76 95 4 lpm Residential In-House basement installation utilizing copper horn water meter support. Ames Series 20 Dual Check Product Availabilities Series 20: Inlet/Outlet Connections Types available, ordering code, sizes available. National Pipe Thread Female 2 2, 4, 5, 20, 25 National Pipe Thread Male 2, 4,, 4 5, 20, 25, 2 Meter Thread Female* 4 4,,, 25, 2 Meter Thread Male* 5 4,,, 25, 2 Pack Joint Female 6 Pack Joint Male 7 Female Solder 8 Male Solder 9 Female Meter Thread (Swivel) 0 4,,, 25, 2 Male Hose Thread Female Hose Thread 2 Male Meter Yoke Thread PEX 5 2, 4, 5, 20, 25 CPVC 6 2, 4, 5, 20, 25 *See How To Order" on pages 7. Union (U) Connections available on all inlet/outlet types and sizes. Pressure / Temperature Maximum Pressure: 50psi (0 bar). Working Temperature: F 40 F sustained; intermittent to 80 F (0.6 C 60 C sustained; intermittent to 82.2 C) Dimensions / Weight Flow B A B B Weight in. mm in. mm in. mm lbs. kgs. 4 8 0 2 5 6 58 4 44.75.79 A B

Series L20 In-Line Testable/Serviceable Dual Check Backflow Preventers Sizes: 4" and " (20 and 25mm) Description The ideal solution for residential containment applications that require in-line testable and serviceable dual check backflow preventers. Standards Tested and certified to meet ANSI/ASSE Standard 024. 024 Important: Inquire with governing authorities for local installation requirements. 0 5 69 0 5 5 0 4" ( 20mm) " (25mm) 5 0 5 20 25 0 gpm 9 8 57 76 95 4 lpm Specifications The dual check backflow preventer shall be designed under the ASSE Standard 024. It shall be bronze-bodied with top and bottom guided plastic check assemblies. The dual check shall have three plugged test ports and shall be capable of being tested in-line. Dual check shall have two top-mounted covers for in-line service. Check assembly shall be designed without screws located within the waterway and shall be fully guided throughout its range of travel. Dual check shall be an Ames Fire & Waterworks Series L20. (Please select the model best suited to your application.) Materials Cast bronze body, plastic check assemblies, silicone discs and stainless steel springs. Product Availabilities Series L20: Inlet Connections - Types available, ordering code, sizes available Connection Sizes Available National Pipe Thread Female 2 National Pipe Thread Male Meter Thread Female * 4 Meter Thread Male * 5 Pack Joint Female 6 Pack Joint Male 7 Female Solder 8 Male Solder 9 Female Meter Thread (Swivel) 0 Male Hose Thread Female Hose Thread 2 Union Tailpiece Tailpiece Seal O-ring Pressure / Temperature Maximum Pressure: 75psi (2.06 bar). Working Temperature: F 40 F sustained; intermittent to 80 F (0.6 C 60 C sustained; intermittent to 82.2 C). * When ordering Series L20 Valves with Meter Thread Connections be sure to order the meter connections one size larger than meter. Examples: Cover Seal O-ring Covers Disk Assembles Cover Seal O-ring Body For /2" (5mm) and 5 /8" (6mm) water meter; order /4" (20mm) meter thread connection. For 5 /8" (6mm) and /4" (20mm) water meter; order " (25mm) meter thread connection. For " (25mm) water meter; order /4" (2mm) meter thread connection. Dimensions / Weight Series L20: Outlet Connections - Types available, ordering code, sizes available National Pipe Thread Female 2 Meter Thread Female 4 Female Hose Thread 2 See "How To Order" on pages 7. Flow B Union (U) Connections available on all inlet/outlet types and sizes. F A E 4 Size A B E F Weight in. mm in. mm in. mm in. mm in. mm lbs. kgs. 5 4 46 2 5 8 67 4 7 8 24 4 9 2..0 25 5 4 46 2 5 8 67 4 5 6 24 25 2..0

Series 20S Residential Fire Sprinkler System Dual Check Backflow Preventers Size: " and 4" (25 and 2mm) Description Installed at the residential fire sprinkler service connection to the main, Series 20S Dual Check Backflow Preventers protect the water supply against polluted water being siphoned back from the sprinkler system. Standards Tested and certified under ANSI/ASSE Standard 024, UL Classified file # EX85, 024 and complies with NFPA Standard D for flow requirements to residential fire sprinklers. (" Size only female by female end connections.) 0 5 69 0 5 5 ", 4" (25, 2mm) 0 0 20 0 40 50 60 gpm 8 76 4 52 90 228 lpm Important: Inquire with governing authorities for local installation requirements. Specification The dual check backflow preventer shall meet the requirements of ANSI/ASSE Standard 024 and be UL Classified. It shall be bronze-bodied and feature replaceable seats and silicone seat discs. The springs shall be captured to prevent injury. The valve shall be capable of flow rate in excess of 50 gpm. Pressure drop at 0 gpm shall not exceed 6psi. An identification tag shall be securely attached to the body by corrosion-resistant mechanical fasteners and a union connection shall be provided. The dual check shall be an Ames Fire & Waterworks Series 20S. Materials Cast bronze body, durable plastic check modules, silicone discs and Buna N seals, stainless steel springs, one union and O-ring union seal. Product Availabilities Series 20S: Inlet Connections - Types available, ordering code, sizes available Meter Thread Female 4, 4 25, 2 *National Pipe Thread Female 2, 4 25, 2 To Fire Sprinklers 20S 20 20 20S Potable water Potable water To Fire Sprinklers Series 20S: Outlet Connections - Types available, ordering code, sizes available Meter Thread Male 5, 4 25, 2 National Pipe Thread Male, 4 25, 2 *National Pipe Thread Female 2 (only) 25 See How To Order on page 8. Dimensions / Weight Pressure / Temperature Maximum Pressure: 75psi (2.06 bar). Working Temperature: F 40 F sustained; intermittent to 80 F (0.6 C 60 C sustained; intermittent to 82.2 C). Maximum recommended flow: 50 gpm (90 lpm). * The " 20S is standardly supplied with female end connections. A B B Weight in. mm in. mm in. mm lbs. kgs. 6 4 7 2 6 7 2 50.6 Flow B B A 5

Series Cu20 Copper-Bodied Dual Check Backflow Preventers Sizes: 2" " (5 25mm) Description The straight line, poppet-type construction of the Cu20 minimizes pressure drop and provides smooth flow characteristics. It can be installed horizontally or vertically. The copper body of the Series Cu20 is lead free and is of a time proven durable material. All models are standardly furnished with double unions for ease of installation and repair. Standards Tested and certified to meet ANSI/ASSE Standard 024. Tested and certified to ANSI/NSF standard 6. Specifications 024 Standard 6 The dual check backflow preventer shall meet ASSE 024. The valve body shall be of copper tube construction and shall be furnished with double unions to facilitate installation. The check module shall be of a modular design and shall include limit stops to prevent over compression or damage to the check valves due to water hammer or thermal expansion. Each check valve shall be both center and edge-guided to ensure repeatable seating and minimize localized wear. The dual check shall be an Ames Fire & Waterworks Series Cu20. 0 5 8 2 62 9 4 6 2 0 5 69 0 2 5 2" (5mm) 4" (20mm) 0 5 0 5 20 25 0 5 gpm 9 8 57 76 95 4 lpm " (25, 2mm) Materials Copper body, corrosion resistant plastic check modules, silicone discs and Buna N seals, stainless steel springs. Pressure / Temperature Maximum Pressure: 50psi (0 bar) 0 5 0 5 20 25 0 5 gpm 9 8 57 76 95 4 lpm Working Temperature: F 80 F (.6 C 82 C) continuous Dimensions / Weight Product Availabilities Series Cu20: Inlet/Outlet Connections - Types available, ordering code, sizes available National Pipe Thread Female 2 2", 4"," 5, 20, 25 National Pipe Thread Male 2", 4"," 5, 20, 25 Meter Thread Female* 4 Meter Thread Male* 5 Female Solder 8 Female Meter Thread (Swivel) 0 See How to Order on pages 8. L A 2 2 Size A L Weight in. mm in. mm in. mm lbs. kg. 2 5 4 7 6 2 6 69.7.7 4 7 6 2 6 69.7.7 25 4 6 9 2 6 69 2.0 4.4 6

HOW TO ORDER Ames Dual Check Backflow Preventers can be specified in many different combinations of connection types, sizes, and union options. See ordering example below. Specify Specify U if union Specify inlet Specify U if union Specify outlet Specify inlet Specify outlet Series No. inlet is desired connection code outlet is desired connection code connection size connection size - 20 U 2 U 2 4" (20mm) 4" (20mm) X Series 20: Inlet/Outlet Connections Types available, ordering code, sizes available. Series 20 20U2-2 4" (20mm) x 4" (20mm) shown * When ordering Series 20 Valves with Meter Thread Connections, be sure to order connection size one size larger than meter thread. Examples: Meter Size Order /2" (5mm) and 5 /8" (6mm) /4" (20mm) 5 /8" (6mm) and /4" (20mm) " (25mm) " (25mm) /4" (2mm) National Pipe Thread Female 2 2, 4, 5, 20, 25 National Pipe Thread Male 2, 4,, 4 5, 20, 25, 2 Meter Thread Female* 4 4,,, 25, 2 Meter Thread Male* 5 4,,, 25, 2 Pack Joint Female 6 Pack Joint Male 7 Female Solder 8 Male Sweat 9 Female Meter Thread (Swivel) 0 4,,, 25, 2 Male Hose Thread Female Hose Thread 2 Male Meter Yoke Thread PEX 5 2, 4, 5, 20, 25 CPVC 6 2, 4, 5, 20, 25 Union (U) Connections available on all inlet/outlet types and sizes. 20 - " X " Series L20: Inlet Connections - Types available, ordering code, sizes available Series L20 L20U2-2 " (25mm) x " (25mm) shown * When ordering Series L20 Valves with Meter Thread Connections, be sure to order connection one size larger than meter thread. Examples: Meter Size Order /2 " (5mm) and 5 /8" (6mm) /4" (20mm) 5 /8 " (6mm) and /4" (20mm) " (25mm) " (25mm) /4" (2mm) National Pipe Thread Female 2 National Pipe Thread Male Meter Thread Female * 4 Meter Thread Male * 5 Pack Joint Female 6 Pack Joint Male 7 Female Solder 8 Male Solder 9 Female Meter Thread (Swivel) 0 Male Hose Thread Female Hose Thread 2 Series L20: Outlet Connections - Types available, ordering code, sizes available National Pipe Thread Female 2 Meter Thread Female 4 Female Hose Thread 2 Union (U) Connections available on all inlet/outlet types and sizes L20 U - (N/A) " X " 7

Series 20S Series 20S: Inlet Connections - Types available, ordering code, sizes available Meter Thread Female 4, 4 25, 2 National Pipe Thread Male 2, 4 25, 2 Series 20S: Outlet Connections - Types available, ordering code,sizes available 20SU4-4 " (25mm) x " (25mm) shown Meter Thread Male 5, 4 25, 2 National Pipe Thread Male, 4 25, 2 Union (U) Connections available on all inlet/outlet types and sizes 20S - /4" x /4" (2m) (2m) Series Cu20 Series Cu20: Inlet/Outlet Connections - Types available, ordering code, sizes available Cu20 4" (20mm) x "(25mm) shown * When ordering Series Cu20 Valves with Meter Thread Connections, be sure to order connection one size larger than meter thread. Examples: Meter Size Order 2" (5mm) and 5 8" (6mm) 4" (20mm) National Pipe Thread Female 2 2", 4", " 5, 20, 25 National Pipe Thread Male 2", 4", " 5, 20, 25 Meter Thread Female* 4 Meter Thread Male* 5 Female Solder 8 Female Meter Thread (Swivel) 0 Cu20 U - U " x " 5 8" (6mm) and 4" (20mm) " (25mm) A Division of Watts Regulator Company www.amesfirewater.com 427 North Market Blvd. Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 F-A-20 0550 Ames Fire & Waterworks. 2005