Field Application of Advanced Residential Air Conditioning Systems

Similar documents
SERVICING S-15 CHECKING CAPACITOR

Introduction. Motor Types

Chapter-8 Capacity Control of Refrigeration Systems

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

Troubleshooting the Indoor AHU as a Standard Product

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

ECM OPERATION MANUAL

Digital Precise Air Control - DPAC

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

WCH5**4. Product Specifications

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

THE TRUSTED CHOICE IN FURNACES ENERGY-EFFICIENT GAS FURNACES

The ultimate fresh air solution.

The Housing Assistance Council is a national nonprofit organization that helps build homes and communities

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Service and Maintenance Instructions

TECHNOLOGY GUIDE :: THE DAWN OF A NEW ERA IN COMMERCIAL HVAC TECHNOLOGY. The all-new Ruud Commercial Renaissance Line featuring:

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

ECM Blower, All Hookups, WarmFlo ST/OT CFM Selection

Installation Instructions

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

Hyperion Field Reference Data TAM8

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

Product Data. Fig. 1 - Unit 50VR -A

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

AirV Standard-Profile RV Air Conditioning

Installation Guide.

Infinity 16. Air Conditioner. Energy-Efficient Air Conditioner with up to 16.0 SEER

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

ENGINEERING SPECIFICATIONS

1.0 Digital Controller

ENGINEERING SPECIFICATIONS

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Submittal Data Performance Data Electrical Data

RSMSD Technical Guide

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

COMcheck Software Version Mechanical Compliance Certificate

Promoting quality installation of central AC (and heat pump) systems

Installation Instructions

Application Engineering

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

BasicTroubleshooting Information and Guidelines

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Checking the Charge on a Heat Pump in the Winter

Dehumidification: Energy Efficiency Comparisons

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

R4H4. Product Specifications

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Advanced Installation and Configuration Instructions

Pioneer Gold Controller Technical Guide

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Ventilation in Humid Climates: Data from Field Experiments

Published by the California Building Performance Contractors Association

Installation Instructions

Trane Family of Terminal Products

OPERATION AND SERVICE for

62DA,DB,DC,DD,DE,DF07-38

Xc21 air conditioner up to seer Xc21

TSTAT0201CW Recommended (sold separately)

Installation Instructions

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

16 SEER Split System Enhanced Heat Pump 4SHP16LT. Features and Benefits WARRANTY

Installation Instructions Part No , Part No Part No

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Note: A/TZONE 950/850 communicating thermostats MUST be used for Variable Speed Outdoor units.

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Wt. Lbs Model Number (BTUH) Hz

Infinity 20. Heat Pump with Greenspeed Intelligence. Variable-Speed, Ultra High-Efficiency Heat Pump with up to 20.0 SEER and 13.

Your Home. Jacco & Assoc.

RDT Refrigeration Book

! CAUTION ! WARNING TABLE OF CONTENTS INTRODUCTION SAFETY CONSIDERATIONS

USERS INFORMATION MANUAL

14 AC x

HE PROFESSIONAL S CHOICE

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS

Transcription:

Field Application of Advanced Residential Air Conditioning Systems Presented By Greg Spencer, Residential Cooling Service Coordinator with Lennox Industries 1

How Ratings Are Established Size of Indoor Coil Type of expansion device Relative Energy Usage Indoor Outdoor Size of Outdoor Coil Efficiency of blower motor Efficiency & type of compressor 2

How Ratings Are Established Includes indoor blower energy. Default Furnace measurement generous 365 watts per 1,000 CFM (W/Mcfm) Most competitors will use default (A variable speed motor beats the default (Takes off roughly 100 W/Mcfm). There are many combinations, so a manufacturer must certify which coil combination will be the Highest Sales Volume Tested Combination (HSVTC) SEER is a system measurement carried by the condensing units & heat pumps 3

Energy Guide Labels (www.eere.energy.gov) What is ENERGY GUIDE? Federal law requires the Energy Guide labels be placed on central air conditioners and heat pumps. Energy Guide labels feature energy use and operating cost information to help shoppers compare appliance models. ENERGY STAR labels marks appliances with superior energy efficiency. ENERGY STAR label may appear on the Energy Guide label if a particular model qualifies. 4

Energy Guide Labels Top You ll find the manufacturer name, model number, type of appliance, and capacity. 5

Energy Guide Labels Middle The label shows how a particular model compares in energy efficiency with other models on the market of comparable size and type. Using a line scale, the label indicates where the model falls within a range of most and least efficient units. 6

Energy Guide Labels Middle Central air conditioners and heat pumps list Seasonal Energy Efficiency Rating (SEER) or other similar efficiency measures. 7

Energy Guide Labels Bottom An estimate of annual operating costs will appear for appliances that are rated by annual energy consumption. This estimate is based on a recent national average of energy prices and assumes typical operating characteristics. 8

Energy Star Program (www.energystar.gov) What is Energy Star? Voluntary product labeling program from the U.S. Environmental Protection Agency and the Department of Energy. To earn the Energy Star, products must meet strictly established energy efficiency standards. Includes new homes, buildings and over 35 product categories, including HVAC. Label is recognized by over 40% of U.S. consumers. 9

Energy Star Program Why? Government-backed symbol Provides unique third-party credibility Enhances the trust factor with consumers. Major HVAC manufacturers currently participate as ENERGY STAR Partners. Wealth of consumer information. Specific resources for HVAC contractors. 10

Three Cooling System Loading Conditions Full System Load (System working at design conditions Designed sensible load) Part System Load (Minimum to maximum cooling loading Reduced latent reduction due to run times) No System Loading (No sensible cooling requirements could be need for latent but no sensible loading ) 11

Full System Loading System Load Calculation (Manual J Version 8) Equipment Selection & SEER (ARI or manufacturer product catalogs) Duct Sizing, Layout and system air balance (Manual D) Proper install equipment per installation instructions Proper equipment Set up per installation instructions 12

Equipment Installation Different configurations Proper installation and set up Correct sized metering device, 13

Equipment Installation Fixed Orifice metering device 14

Equipment Installation No metal to metal rubbing, proper refrigerant pipe routing, proper clearances around unit. 15

Equipment Set up (Indoor Blower) 16

Equipment Set up (Indoor Blower) Proper blower speed setting Balanced distribution system Latent heat air adjustments 17

Equipment Set up (Charging) Several different ways of charging or checking charge in air conditioners and heat pumps in the installation instructions and service manuals. Always use more than one method to charge or check charge in system. Weigh in Sub-cooling Superheat (Fixed Orifice, piston, flow-meter) Approach 18

Equipment Set up (Charging) Fixed orifice charging by superheat Under part load conditions, the fixed orifice will provide reduced latent capacity as compared to a TXV. 19

Equipment Set up (Charging) 20

SL Temperature minus - SL Pres. To Saturation equals = 60 45 15 Superheat Sub-cooling & Superheat Calculation Explained 220# 76# Indoor Coil Outdoor Coil Superheated Vapor Saturated Vapor Low Pres. Liquid Sensible Latent Sensible Latent Sensible High Pressure, High Temperature Vapor Saturated Vapor High Pressure, Subcooled Liquid LL Pres. to Saturation 108 Basic Refrigeration Circuit Properly Charged Unit LL Temperature minus - equals = 98 10 Sub-cooling

SL Temperature minus - SL Pres. To Saturation equals = 60 45 15 Superheat Sub-cooling & Superheat Calculation Explained 290# 76# Indoor Coil Outdoor Coil Superheated Vapor Saturated Vapor Low Pres. Liquid Sensible Latent Sensible Latent Sensible High Pressure, High Temperature Vapor Saturated Vapor High Pressure, Subcooled Liquid LL Press. to Saturation 128 Basic Refrigeration Circuit Over Charged Unit LL Temperature minus - equals = 108 20 Sub-cooling

SL Temperature minus - SL Pres. To Saturation equals = 68 26 42 Superheat Sub-cooling & Superheat Calculation Explained 182# 50# Indoor Coil Outdoor Coil Superheated Vapor Saturated Vapor Low Pres. Liquid Sensible Latent Sensible Latent Sensible High Pressure, High Temperature Vapor Saturated Vapor High Pressure, Subcooled Liquid LL Press. to Saturation 95 Basic Refrigeration Circuit Under Charged Unit LL Temperature minus - equals = 95 0 Sub-cooling

Part and No System Loading Maximize amount of dehumidification done during cooling cycle.(coldest coil) Prevent any re-evaporation of condensation back into the supply air system. (Cycle indoor supply fan, condensate management) Us of exhaust fans when high humidity is being added to home Proper venting of appliances (Ex:dryer) Elimination of moisture sources. 24

Reduction Measures 25

Dehumidification Control Room thermostat with dehumidification features. Indoor blower speed option setting Outdoor fan motor option setting Hot gas bypass Reheat Stand alone dehumidifiers 26

Cooling call No cooling call Room thermostat with dehumidification features Integrated with a reheat system 27

Equipment Set up (Indoor Blower) GE ECM 2.3 or 2.5 Premium ECM X13 Standard ECM Motor can be programmed to have dedicated dehumidification speed taps. 28

Feature Benefit Comparison Feature PSC X13 ECM 2.3/2.5 Input Voltages 120 or 240 120 or 240 120/240 Power Connection Relay Constant Constant Control Signals High voltage Low voltage 24VAC / PWM / DSI Settings 2 to 5 2 to 5 Variable Airflow Control Speed Torque Constant Speed Range 800-1100 600-1100 200-1300 Off Delay - Slew with external timer off delay - slew programmable On Delay - Slews with external timer slew programmable Output channel none none programmable Bearings SB or BB BB BB Control Replacement Motor Motor Modules 29

Airflow (CFM) 1400 1350 1300 1250 1200 1150 1100 1050 1000 X13 Airflow Example (300) (318) (324) (332) (338) (237) (247) (255) Low Speed Pressure (264) (263) High Speed (348) (363) (372) Airflow (CFM) 1400 1350 1300 1250 1200 1150 1100 1050 (Watts) 1000 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Low Speed (Watts) PSC Airflow Example (535) (462) (523) (427) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Pressure (502) (406) (475) (396) High Speed (466) (385) (454) (417) (390) Airflow (CFM) 1400 1350 1300 1250 1200 1150 ECM 2.3 Airflow Example Constant CFM (215) (253) (282) (314) (348) (362) (409) (426) 1100 1050 1000 (Watts) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Pressure 30

The interface board (tap board) functions may be on a separate circuit board or built into the OEM s main circuit board*. Discrete field selection of airflow settings and comfort options. Cooling Airflow Heating Airflow Trim/Adjust Multipliers OR Climate (delay) Profiles Humidistat Option Connect to Connect to 2.3 or 2.5 31

Thermostat Mode (model 2.3) Most widely used method of control for residential systems A 24vac thermostat can communicate directly to the motor or through an interface board (tap board). ECM 2.3 Motor Control Control (male) Pin number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Common C1 W/W1 Common C2 Delay tap select Cool tap Select Y1 Adjust tap select Output - Return valve (heat pump only) Humidistat (BK) Heat tap select 24 VAC (R) 2 nd stage heat (EM/W2) 2 nd stage cool (Y/Y2) Fan (G) Output + 32

PWM (Pulse Width Modulation) Mode (model 2.3) Best suited for commercial systems although some OEM s have, and are currently using it in residential applications Controlled by an external PWM (pulse width modulated) signal Suitable for fully variable speed systems (EX: Zoning) PWM simply uses two signals, a start/stop signal and a PWM signal PWM (Duty Cycle) D % Demand = x 100 T (in torque or airflow) +23 V +9 V D 0 V T 33

PWM (Pulse Width Modulation) Mode Cont. Pin number OR ECM 2.3 Motor Control 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Connected to PWM common NC* Connected to PWM common NC* NC* NC* NC* NC* NC* PWM signal NC* NC* NC* NC* Start/Stop signal: 33VAC or 23VDC NC* * Not Connected 34

DSI (Digital Serial Interface) Mode (model 2.5) Next generation serial communicating systems Controlled by Digital Bus System Controller Digitally communicates with the motor: Speed, Airflow, Starts, Stops 2 leads for power (12 VDC) 2 leads for communication Control Board Connection Communication Example Command Pin 1 12 VDC 2 GND 3 Transmit/Receive 4 Transmit/Receive 16 pin connector on motor 12 V 0 V 1000001 0011100 0001110 0.3 sec 35

X13 Feature Set Fully encapsulated electronics (all conductive surfaces potted) 3 Phase Brushless DC (single phase AC input) Ball Bearing construction Integral control module FCC B EMI filter Approx 1 inch shorter than current Premium ECM 2.3/2.5 36

Power X13 Harness Schematic Options (AC Low Voltage Control) System Control Board L N G L N G Signal (1 to 5 + common) Low voltage C T1 T2 T3 T4 T5 C G W Y NC * NC * GE Customer 37 * Could eliminate leads * Optional Cooling Selections

Power X13 Harness Schematic Options (DC Low Voltage Control) System Control Board L N G L N G Signal (1 to 5 + common) Low voltage C T1 T2 T3 T4 T5 Return Fan Heat Cool GE Customer 38

Outdoor fan motor option setting Motor can be programmed to have dedicated dehumidification speed taps. Inputs can be sent to the motor to vary or change speeds depending on demands 39

Other Residential HVAC ECM Motor Applications Outdoor Condenser (ECM 142) Similar to the 2.3/2.5 construction Constant speed instead of constant airflow 240vac power input Optional Remote Mounting 24vac Control Inputs 1/3 Hp 40

Two Power Inputs - Line voltage and 24vac inputs Outdoor Condenser (ECM 142) Repair - One piece motor replacement - Form drip loops and mount per OEM specifications (center on stator area) Y1 --------- Y2 --------- 41

Compressor option (Two stage) Humidity Control (67% Part Load Capacity) Simpler Design Scroll Design No Shutdown To Change Capacity Less Applied Components 42

Compressor option (Two stage) Bypass Ports Closed Bypass Ports Open 43

Compressor option (Two stage) Modulation Ring/Bypass Seals Solenoid Actuator Coil Solenoid Return Spring 44

Hot gas bypass 45

Reheat 46

47

Reports on Dehumidification 48

Report on Dehumidification 49

Report on Dehumidification System research took 20 homes in the Houston area to evaluate the humidity control performance and operating cost of six different integrated dehumidification and ventilation systems 50

Report on Dehumidification 51

Stand Alone Dehumidifier 52

Stand Alone Dehumidifier 53

UltraAire System 54

UltraAire System 55

Filter-Vent System 56

Filter-Vent System 57

ERV System 58

ERV System 59

ECM fan & Thermidistat 60

ECM fan & Thermidistat 61

Conclusions All of the systems with dehumidification of re-circulated air, separate from the cooling system, exhibited much better humidity control than those with dehumidification of ventilation air only (ERV) and those with dehumidification only as part of the cooling system. 62

Training Information Lennox, Carrier and Trane all offer classroom or on line training. Air Conditioning Contractors Association www.acca.org (Manuals and CDs) Air Conditioning and Refrigeration Institute www.ari.org - CoolNet for Certified Products and Ratings 63