SUKI. Dehumidifier WDH-928DB -20R. User s Manual

Similar documents
SAVE. Features. Excellent drying laundry function. Powerful dehumidifying capability. Quiet operation

20L/D DEHUMIDIFIER Model Number: IG9800

DD12E DEHUMIDIFIER USER'S MANUAL CONTENTS. VOLTAGE: V~50Hz

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

12L Dehumidifier Model: HG00923

DEHUMIDIFIER USER S MANUAL CFO-12E CFO-20E

DEHUMIDIFIER USER'S MANUAL. Dry Mec 16. VOLTAGE: V~50Hz CONTENTS

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

MeacoDry ABC Range Dehumidifiers

DUE-1237 DEHUMIDIFIER Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Air Dehumidification System. Instruction Book CLI-DH8D

PORTABLE AIR CONDITIONER

Meaco 10L small home dehumidifier Instructional Manual

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

30-pint Dehumidifier User Guide

PORTABLE DEHUMIDIFIER

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

compact ceramic heater

2.9kW Portable Air Conditioner

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

2.9kW Portable Air Conditioner

OPERATING INSTRUCTIONS

20L Electronic Dehumidifier

ODE20: 20 LITRE DEHUIMIDIFIER

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Up to 60 Pint Commercial Grade DEHUMIDIFIER

GDDEM10 DEHUMIDIFIER

OPERATING INSTRUCTIONS

Operation manual. Dehumidifier CFO-20N

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Dehumidifier. User Manual

PORTABLE AIR CONDITIONER

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

Fundamental safety warnings

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Portable Dehumidifier with Internal Pump

10L Evaporative Cooler with Timer

General Care and Safety Guide

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

OPERATION MANUAL. Model: IC702/703 Ice Maker

Operating Instructions

GL-DEH Series Portable Dehumidifier Operating Instructions

IG9813 USER MANUAL. 12 Litre Dehumidifier White. Batch code:

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Dehumidifier Owner s Manual Read and save these instructions before use

Portable Dehumidifier

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Models GDNM16A5BK4AA GDNM20A5BK4AA GDNM24A5BK4AA DEHUMIDIFIER OPERATING INSTRUCTIONS

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

15,000 BTU Portable Air Conditioner

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Meaco Platinum Range Instruction Manual

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

PANEL RADIATOR. USER MANUAL HSDOnline.co.uk 2KW OIL FILLED POH04

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

6.6L Stainless Steel Urn. User Manual

Instruction Manual. Refrigerator. Model: HS-65L

Professional HEPA Air Cleaner

Please read and keep manual to ensure safe and effective use of this Appliance HOUSEHOLD USE ONLY

7Litre Evaporative Cooler With Remote

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

COMPRESSOR DIGITAL DEHUMIDIFIER

PORTABLE AIR CONDITIONER (LOCAL)

Portable Air-conditioner Use and Care Manual

5) Do not start or stop the unit by inserting or pulling out the power plug.

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

PORTABLE AIR CONDITIONER (LOCAL)

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Local Air Conditioner

Platinum Series Electronic Panel Heaters

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

Dehumidifier. Instruction Manual. Model DH-320/A

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Convection Panel Heater

READ AND SAVE THESE INSTRUCTIONS

Turbo Circulating Fan (DC)

Dehumidifier Déhumidificateur Dehumidificador

Air always contains a certain amount of water in the form of vapour. This determines the

Manual for Ceiling Patio Heater

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Premium Low Energy Compressor Dehumidifier with Digital Humidistat CD16LE 16 litres per day USER MANUAL

OWNER S MANUAL. Portable Dehumidifier: BHD-H Series BHDP-H Series R-410A

PORTABLE AIR CONDITIONER (LOCAL)

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Transcription:

SUKI Dehumidifier WDH-928DB -20R User s Manual Lion Healthcare PO Box 566, Cottesloe, WA, 6911 Phone 1800 011 653 Email sales@salinplus.com www.salinplus.com

Contents Structure and principle Features...3 Specifications... 4 How dehumidifying works... 4 Device overview...5 Operation Control panel...5 Operation instructions... 6 Continuous draining...7 Maintenance Storing the dehumidifier... 8 Important safeguards... 8 Caring for the dehumidifier... 9 Troubleshooting... 10 Warning...10 Cautions...10 Before using your dehumidifier, please read the user s manual carefully, in order to ensure correct and safe use. After reading the manual, make sure it is stored in a safe place for future reference if necessary. 2

Features Powerful dehumidifying capability The dehumidifier powerfully removes excess moisture from the air creating a drier, healthier home environment. Excellent drying laundry function The dehumidifier dries laundry quickly. This can prevent laundry and furniture from becoming damp and musty in a rainy season. Quiet operation The dehumidifier is suitable for over night operation. Drainage tank with a large capacity 4.8 litre capacity water tank means the dehumidifier requires emptying less often. Using refrigerant for protecting environment The dehumidifier uses no CFC refrigerant therefore protecting the environment. Modern Design The dehumidifier is compact with a streamlined appearance and modem design. The castors at the bottom allow easy mobility. Saving energy The power consumption is low. SAVE 3

Specifications MODEL WDH-928DB -20R Power Supply 220 240V ~ 50Hz Moisture removal 10 L/D (27 o C 60%RH) 20 L/D (30 o C 80%RH) Power input 340W Dehumidification Size of shell (W x H x D) 390 x 610 x 274mm Weight 15kg Operating temperature Water tank 5 o C ~ 35 o C 4.8 litres If the power cord on this unit is damaged it must be replaced by the manufacturer, its service agent or qualified persons in order to avoid a hazard. This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. How Dehumidifying Works If you pour cold water into a cup, the air around the cup is cooled, and drops of water form on the surface of the cup. The dehumidifier takes advantage of this phenomenon to remove moisture. Moist air Compressor Cooling unit Re-heating unit Dried air Drainage tank It draws in room air, cools it with a cooling unit, and changes the humidity to drops of water. The drops of water fall into a drainage tank. The dehumidified air is re-heated by a heating unit and discharged. Steps,,and are repeated to remove humidity from the room. After the air passes through the re-heating unit, its temperature will rise a little, so that the temperature of the room will rise by 2 to 4 o C. This is normal operation. 4

Device Overview OUTLET FOR DEHUMIDIFIED DRY AIR HANDLE CONTROL PANEL AIR FILTER DRAIN BUCKET TURNING WHEEL CONTINUOUS DRAINAGE HOLE Control panel 5

Operation Instructions START OPERATION 1. Make sure the plug is firmly plugged into the wall socket. 2. Make sure the device water tank is placed in its correct position. (After powering on the device for the first time, if the full tank light lights up, just pull out the water tank then push it back to the proper position). WHEN FULL TANK LIGHT IS ON When the water tank is full, the indication light will light up, the device will stop operating. Remove the water in the tank, then place the water tank back in it s proper position, the device will start operating again. Remove the water in the water tank with two hands HUMIDITY SETTING When device is turned on the screen will show room humidity and the humidity setting on the tube shaped icom. If the tube shape icon shows a setting at 70% and you want the RIH down to 40% or 50% press the down arrow head until the tube shaped icon shows 40% or 50%. The device will now continue working until the area has reached the desired humidity. If you want more moisture out lower the RIH setting. TIMER OPERATION The timer can be used to turn the device ON or OFF when you are away from the premises. On a 12Hr cycle.to turn the device on. With the cable connected into the socket (DO NOT START THE DEVICE) press timer button to the amount of hrs when you want the device to start (shown on the screen) it is now set to come on automatically. To set time to turn off. With the device running press timer button to the amount of hours when you want the device to automatically stop. HEATER FUNCTION Heater function can work independently or in conjunction with dehumidifying. To work both heating and dehumidifying at the same time press the heater button on when in dehumidifying mode. To use the heater only turn device on and heater button on, on the humidity setting tube icon set this to a high humidity 80% if the humidity in the area is lower than 80% the compressor will shut down and the fan and heater will only function. If you decide at any time you want the dehumidifyer function to come on lower the humidity level by pressing the downward arrow head until you hear the compressor start. DEFROST When operating in low temperatures (less than 12 o C) the surface of the evaporator will accumulate frost and effect the efficiency of the dehumidifier. When this happens the device will go into periodic defrost mode automatically. This is quite normal. Defrost light will come on. The device will operate in temperatures down to 5 o C in the area it is being used. Defrost times may vary. If the dehumidifier freezes up turn the device off and let ice melt then turn the device back on. If the device freezes up again it may be that the temperature is lower than 5 o C, if it is, then you should not run the device until the temperature rises. If the device continues to freeze up it may need looking at, return it to the place of purchase to be sent back for service. 6

Continuous Drainage CONTINUOUS DRAINAGE OPTION 1. Ready to drain out the water using PVC hose not supplied (inside dia.13mm). 2. Take out the water tank and use tool to open the closed hole on the side of casing to place the hose on the water outlet drain point. Continuous drainage hole 3. Place the PVC hose through the hole and onto the drain outlet point. Have the hose on a downward angle for the water to run free. 4. Place the water tank firmly back into position. THE PROPER WAY TO PLACE THE WATER DRAINAGE PVC HOSE When using continuous drainage, the PVC hose must be placed below the drainage hole. Avoid uneven ground and kinking drainage hose. 7

Storing the Dehumidifier When the device is not to be used for a long period of time 1. Fold up the power supply cord. 2. Discard any water left in the drainage tank and wipe away any remaining drops with a cloth. 3. Clean the air filter. 4. Store the device. Package the device to keep it free of dust, and keep it upright and store it in a cool, dry place. Important Safeguards Please note the following safety precautions when using the unit: 1. When the dehumidifier is used in the laundry, ensure there is adequate clearance between any clothes and the device to prevent water dripping on the unit. 2. Before cleaning the device or when it is not in use for a long period of time, unplug the power cord. 3. Do not use the dehumidifier in the immediate surroundings of a bath, shower, or swimming pool. 4. Do not place the device close to a heater, or any appliance which will have a high temperature. 5. Do not place any objects into the air inlet or outlet. 6. Do not sit or stand on the unit. 7. Discard water that has collected in the tank regularly. 8. Do not place the dehumidifier in an enclosed area, ie. closets, which will prevent air circulation. 9. Do not use the dehumidifier for any purpose other than for which it was originally intended. 10. Install the external drain piping on a downhill gradient to ensure that condensed water can be drained continuously. 11. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid hazard. 12. The device is not intended for use by young children without supervision. 8

Caring for your Dehumidifier Before cleaning your dehumidifier, first ensure that the device is disconnected from power supply. 1. Outer case: Wipe the shell with a soft, slightly damp cloth. Do not immerse in any liquid. Dry with a dry cloth. Do not use harsh abrasives or solvents. 2. Air filter cleaning: For best results, clean your air filter regularly, as it will become clogged with dust over time. To remove the filter, remove the water bucket and tip the appliance towards the rear at an angle of approximately 15 degrees. The filter is located behind the front grill and should be pulled downwards to remove. Pull out the filter gently. To clean the air filter, run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is very dirty, wash it with warm water and a neutral cleaning solvent and dry it thoroughly. 3. Insert to its original position. Troubleshooting In case your dehumidifier shows any abnormality, please check the items mentioned below first: Problem Possible cause Solution Both fan and compressor not working. No power to unit. Check power to socket. Check power switched on. Compressor or fan not working. Motor failure. Faulty electronics. Return for service. Not collecting water. Air intake filter blocked. Refrigerant is low. Temperature and humidity are too low. Clean filter. Return for service. Normal function. Noisy unit. Floor uneven. Place on a level surface. Condenser frozen. Filter is dirty. Temperature is too low. Clean filter. Switch off and wait for temperature to rise. Leaks. Bucket not installed properly. Micro switch failure. Unit has frozen. Fit properly. Return for service. Unplug and allow ice to melt. 9

Warning Do not fold or knot the power cord as shown below! Make sure the plug is inserted firmly and properly into the outlet! Do not insert multiple plugs into the electrical socket as shown below! Make sure the plug is clean! After turning off the device, unplug the power cord! Do not plug in the power cord if hands are wet! Cautions Do not place anything on top of the control panel! Do not cover the device s air vents! Do not allow children to climb on or play with the device! Do not wet the device or control panel! Keep flammable materials away from the device! Contact a professional for service repair! 10

Cautions Do not pull the power cord as shown. Do not spray any aerosols near the device. Ensure the device is placed on a flat surface. Always keep the device at least 20 cm away from the wall to allow heat to dissipate properly. Hang clothing at least 50 cm above the device. Do not insert anything into the device. For best results close all windows and doors. Keep the device away from all sources of heat. When moving or storing the device, do not place it sideways or upside down. 11