>>> FIRE MY11 >>> ACCORDING TO VERSIONS NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS

Similar documents
FIRE MY11 - FIRE RADIO MY11 SAFETY CABINETS CERTIFIED FOR THE STORAGE OF FLAMMABLE AND RADIOACTIVE PRODUCTS

Safety cabinets for the safe storage of flammable liquids and other hazardous materials. Type 90 Type 30

Explosion-Proof Waste Chemical Storage Cabinets

Flammables Safety Cabinets

Flammable. cabinets. Corrosive. cabinets. Toxic cabinets. and multirisk. Pesticide range. Fume hoods, filtering. cabinets - Ventilation

UTILITIES SICUR WOOD 61 SICUR 63 SICUR KEM 64 SICUR SHELF 65 PHYTOSAFETY 66 DRUM STORAGE SUMPS 67 ABSORBENT PADS 68 EMERGENCY EYE AND BODY SHOWER 69

Laboratory Refrigerator/Deep Freezer TC 802

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

EN Storage of gas cylinder

5 Supply and disposal

Innovation in air purification unmatched air quality

Safety vacuum drying oven for flammable solvents

4 Storage cabinets SCALA

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Evaporators. In this section. Rotary Evaporators Crystalisation Distillation Drying Reflux Solution Concentration Volatiles Glassware

REFRIGERATOR M E D I C A L.

THE Clifton RANGE. NICKEL-ELECTRO Ltd. Manufacturers of laboratory, medical and clinical equipment. NICKEL-ELECTRO Ltd.

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Multi-Lab REFRIGERATORS Frigidere medicale

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

Accessories. Laboratory refrigerators and freezers. Accessories. Climate rating definitions. Customer service.

EDS - SPARK DETECTORS - GENERAL NOTES

Operating instructions Page 12

DOUBLE DOOR FREEZER.

Biological Incubators Biotech Ovens

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Reach-In. PLanT GROWTh. Reach-In

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

MINITOP Refrigerated Self-Service Display underneath

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Platelet bags constant shaking for long periods of time.

Technical Ventilation

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION

EC 160 CO 2. Incubator

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Vacuum drying VD VDL series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers

Direct Fired Heater Model AD Specification

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Chromatographic Air circulated Refrigerator, two-door TC 603

Roof top SPACE RPC 450Z R407C M011

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Gebrauchsanleitung Weintemperierschrank Seite 2. Operating Instructions Wine Cooler Page 14. Gebruiksaanwijzing Wijnklimaatkast Pagina 26

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

AUTOMATIC FIRE SUPPRESSION SYSTEMS

BINDER Scientific Product Catalog

Vacuum drying oven for non-flammable solvents

Operating instructions Page 6

OMNITOP Refrigerated Display with Ventilated Cooling

Flammable Liquid Storage

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

STABILITY ICH. ICH Stability Tests

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

FOGEL Caribbean Corporation

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

TCR. Features: TISSUE CULTURE

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Heated Gas Sampling Probe PSG Basic

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

700XP & 900XP accessories

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Chromatographic Air circulated Refrigerator, two-door TC 603

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

ROTATORY EVAPORATOR AND PUMPS

LYODEL FREEZE DRYING SYSTEMS

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

Refrigeration Contents

Digital incubating/ refrigerating benchtop shakers

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94


External and internal circulation with powerful pumping capability

Cat_Refrigerazione_ING MOD :17 Pagina 1 Refrigeration

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

laboratory & sterilization technology

Using the Model 1500 Portable Chilled Mirror Hygrometer

ENVIRONMENTAL HORTICULTURE: AGRISCIENCE AND BIOTECHNOLOGY September 30, 2010

Warnings, Safety Information and Guidance

gas monitoring system

Using the DewTrak II Dew Point/ Humidity Transmitter

Internet. Climate rating definitions. Customer service.

Transcription:

>>> FIRE MY11 NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS >>> ACCORDING TO VERSIONS WE OFFER AN INCREASED STORAGE CAPACITY OF 20/25% >>> ADVANTAGE OF PARTS REPLACEMENT IN CASE OF BODY DAMAGE >>> NEW CLOSING SYSTEM

EN >>> FIRE MY11 Type 90 NEW SAFETY CABINETS FOR THE STORAGE OF FLAMMABLE PRODUCTS WITH 90 MINUTES FIRE CLASS CERTIFIED RESISTANCE ACCORDING TO EN. Completely manufactured from 1-1,5 mm thickness steel sheet, cold pressed, epoxy coated with acid resistant epoxy powders electro-statically applied at a temperature of 200 C, which ensures a layer thickness higher than 90 microns on the whole surface of the cabinet. Special insulation with rock-wool fibers high density panels (Fiberceramic exempt) resistant to high temperatures (800 C) and panels of calcium sulphate. Internal finishing with MFC panels, resistant to acid and corrosive vapours. Certification as from last EN norm. Automatic door closure in case the ambient temperature exceeds 50 C (according to market). Lock with key and door blockage. Feet adjustment level. 90 minutes certified valves close the ventilation holes when the temperature exceeds 70 C; one is placed on the roof for extraction, one on the bottom to guarantee the extraction of heavy vapours. Air extraction duct collar 100 mm diam. placed on top of the safety cabinet. Anti-sparking hinges. 3 cm thermo-expanding gasket (DIN 1402). no. 3 epoxy coated or stainless steel shelves on stainless steel supports, height adjustable. Bottom sump with draining grid which allows a bigger storage volume. Grounding connection on top of the cabinet to prevent electrostatic charges. New closing system which allows to keep the doors open. Automatic door closing in case the ambient temperature exceeds 50 C. FIRE MY11 - Model 120 FIRE MY11 MODELS 120: TEST LAPI No. 1583.0EN100/10 FIRE MY11 MODELS 120 TYPE 90 BASIC FIRE MY11 120 Type 90 * EASY FIRE MY11 120 Type 90 * EXTERNAL INTERNAL CAPACITY No. OF 1 LITER BOTTLES EACH CABINET WEIGHT (Kg) CSF232BMY11 1200 x 600 x 1950 1095 x 446 x 1625 160 / 200 350 CSF232MY11 1200 x 600 x 1950 1095 x 446 x 1625 160 / 200 350 Add Y to the code for yellow safety cabinet. No. OF SHELVES CAPACITY (liters) No. 3 epoxy coated tray shelves, height adjustable. Certified loading capacity 80 kg 1094 x 420 x 39 - about 16 liters No. 3 stainless steel tray shelves, height adjustable. Certified loading capacity 80 kg 1094 x 420 x 39 - about 16 liters EPOXY COATED BOTTOM SUMP WITH DRAINING GRID CAPACITY (liters) 1094 x 445 x 100 about 45 liters 1094 x 445 x 100 about 45 liters 2

EN FIRE MY11 - Model 60 >>> FIRE MY11 Type 90 FIRE MY11 MODELS 60: TEST LAPI No. 1582.0EN100/10 FIRE MY11 MODELS 60 TYPE 90 BASIC FIRE MY11 60 Type 90 * ** EASY FIRE MY11 60 Type 90 * ** EXTERNAL * Add Y to the code for yellow safety cabinet. ** Add D to the code for safety cabinet with right opening. INTERNAL CAPACITY No. OF 1 LITER BOTTLES EACH CABINET WEIGHT (Kg) CSF239BMY11 595 x 600 x 1950 493 x 446 x 1625 80 / 100 210 CSF239MY11 595 x 600 x 1950 493 x 446 x 1625 80 / 100 210 No. OF SHELVES CAPACITY (liters) No. 3 epoxy coated tray shelves, height adjustable. Certified loading capacity 60 kg 493 x 420 x 39 - about 7 liters No. 3 stainless steel tray shelves, height adjustable. Certified loading capacity 60 kg 493 x 420 x 39 - about 7 liters EPOXY COATED BOTTOM SUMP WITH DRAINING GRID CAPACITY (liters) 493 x 445 x 100 about 20 liters 493 x 445 x 100 about 20 liters 3

EN Non-sparking extraction system CSF100BPMY11 (optional) >>> FIRE MY11 Type 90 OPTIONAL ACCESSORIES DESCRIPTION PS50MY11 Door s thermal closing system CSF100BPMY11 CSEST Internal or external automatic extinguisher RIP60VMY11 Additional epoxy coated steel shelf tray for safety cabinet with 1 door 493 x 420 x 39 RIP120VMY11 Additional epoxy coated steel tray shelf for safety cabinet with 2 doors 1094 x 420 x 39 RIP60MY11 Additional stainless steel tray shelf for safety cabinet with 1 door 493 x 420 x 39 RIP120MY11 Additional stainless steel tray shelf for safety cabinet with 2 doors 1094 x 420 x 39 CSF100BPMY11 RSOL CFN ADCFNMY11 CSAS CSBE CSMP CSPF Non-sparking extraction system in metal box, with electric installation and power cable and metal case for filter Activated carbon filter alternative solution Exhaust filter/fan module according to NFX 15-211 norm Adapter for CFN cabinets MY11 Activated carbon filter for solvents (for CFN) Activated carbon filter for acid vapours (for CFN) Activated carbon filter for acid vapours and solvents (for CFN) Anti-dust pre-filter (for CFN) 270 x 260 x 430 Exhaust filter/fan module according to NFX 15-211 norm 4

FIRE RADIO Type 90 EN FIRE 60 RADIO Type 90 Code CSF239XMY11 CERTIFIED FIRE RESISTANCE 90 minutes (Type 90) STEP CLOSE Patented automatic thermal closing system when ambient T > 50 C. STANDARD ACCESSORY FOR THE WHOLE SERIES. FIRE RADIO models FIRE 60 RADIO Type 90 FIRE 60 UB RADIO Type 90 External dimensions (L x W x H) mm Internal dimensions (L x W x H) mm No. of one-litre bottles for contained in the cabinet Weight (Kg) Stainless steel shelves Steel sump grid Automatic doors closure when T > 50 C CSF239XMY11 590 x 600 x 1980 450 x 430 x 1848/1550 60/80 350 3 Yes Yes CSF606XMY11 590 x 500 x 620+80 440 x 340 x 510/345 10/12 150 NO Yes Yes SAFETYFIRECASE RADIO Type 30 CSF500X 340 x 340 x 400 200 x 200 x 265 4 45 NO Only trough Yes 5

FIRE RADIO Type 90 - Type 30 EN CERTIFIED FIRE RESISTANCE 30 minutes (Type 30) SAFETYFIRECASE RADIO Type 30 Code CSF500X Portable safety cabinet for n. 4 one-litre bottles or n.1 five-litres bottle with sump. Complete with trolley. FIRE 60 UB RADIO Type 90 Code CSF606XMY11 Optional accessories FIRE RADIO CERTIFIED FIRE RESISTANCE 90 minutes (Type 90) Dimensions (L x W x H) mm Stainless steel shelf for FIRE 60 RADIO RADIORIP60MY11 407 x 385 x 25 Non-sparking extraction system in metal box, with electric system and power cable Atex extraction system in metal box, with electric system and power cable CSF100BPMY11 270 x 260 x 430 CSF100ABPMY11 270 x 260 x 430 Filter holder box BP100 140 x 250 x 90 Activated carbon filter Daily timer Internal or external automatic extinguisher ALLARME Coldy for model FIRE 60 RADIO RSOL TIM24 ESTINTORE AT100 CSFR127 FIRE RADIO ARMADI Safety cabinets for radioactive products certified according to EN. Completely built in stainless steel with lead screening (2 mm)*. 6 * Standard, other thicknesses on request.

OPTIONAL ACCESSORIES Painted steel shelves (FIRE BASIC Type 30). Internal or external automatic extinguisher. CHEMISAFE TEMPERATURE ALARM SYSTEM. Temperature control system, alarm and phone call. The system has a digital thermostat with probe which continuously detects the temperature inside the cabinet. When the temperature is higher than the programmed one, an optical acoustic alarm starts and a telephonic device calls the predetermined phone numbers (24 numbers possible). THERMOSTAT TECHNICAL FEATURES: Measuring range: from -40 C to 99 C; Precision: +/- 1 C; Resolution: 1 C; Relay exit: 10 /240 VAC. TELEPHONIC DEVICE TECHNICAL FEATURES: 6 channels with message repetition till 5 times; Remote system questioning; 24 events non-volatile memory; Power supply 6 V c.c. or 12; IMQ approval 1 st level. Painted steel rotating shelves for FIRE 60. Anti-sparking extraction system Code CSF100 BPMY11 Optional accessories Right Step Close (patented) Left Step Close (patented) PS50MY11 PS50SMY11 Dimensions (L x W x H) mm Painted steel shelf for FIRE 120 RIP120VMY11 1094 x 420 x 39 Painted steel shelf for FIRE 60 RIP60VMY11 493 x 420 x 39 Stainless steel shelf for FIRE 120 RIP120MY11 1094 x 420 x 39 Stainless steel shelf for FIRE 60 RIP60MY11 493 x 420 x 39 Rotating shelf for FIRE 60 RIPGI 390 x 30 (Ø x A) Non-sparking extraction system in metal box, with electric system and power cable Atex extraction system in metal box, with electric system and power cable Activated carbon filter Daily timer Internal or external automatic extinguisher Alarm COLDY FOR MODEL FIRE 120 COLDY FOR MODEL FIRE 60 Wall fixing system SAFETYFIRECASE TROLLEY SAFETYFIRECASE CSF100BPMY11 270 x 260 x 430 CSF100ABPMY11 270 x 260 x 430 RSOL TIM24 ESTINTORE AT100 CSFR128 CSFR127 CSF550 CSF560 COLDY: REFRIGERATING SYSTEM (PATENTED) FOR SAFETY CABINETS FOR STORAGE OF LOW FLASH POINT PRODUCTS. The system has a cryostat unit which cools a liquid till -15 C and, through a pump, pushes it inside the cabinets with special pipes. A thermal exchanger, modular and suitable to the whole CHEMISAFE FIRE series, lowers the internal temperature with possibility to adjust it according to the special needs of the stored products. A higher safety is given by a sprinkler (1) mounted on the exchanger which, when temperature reaches 68 C, releases a liquid preventing a possible internal fire. An internal temperature control is possible through a digital thermometer (2) placed on the cabinet s door. A easy clicking system makes connections and maintenance very easy. The standard temperature is +20 C (special applications on request). 2 1 1 Higher safety given by a sprinkler which, in case of fire, releases a liquid from the exchanger. 2 Digital thermometer for monitoring internal and external temperature with COLDY. 7

INFLAMMABLE LIQUIDS STORAGE SYSTEM EN APPLICATION FOR SAFETYFIRECASE Code CSF220 Inflammable liquids storage system, directly from the safety cabinets. Connection hole REI 180. No. 4 one-litre bottles or no. 1 five-litres bottle. APPLICATION TO UB SERIES Code CSF200MY11 Inflammable liquids storage system, directly from the safety cabinets, with level control and acoustic alarm. Communication hole REI 180. No 1. twenty-litres tanks. Spare twenty-litres tanks - Code CSF210MY11 8

NEW SAFETYFIRECASE PORTABLE CERTIFIED SAFETY CABINET FOR THE STORAGE OF 4 BOTTLES OF INLAMMABLES IN ACCORDANCE WITH THE RECENT HARMONISED STANDARD BS EN (TYPE 30). SAFETY CABINETS FOR THE STORAGE OF INFLAMMABLES, CERTIFIED FIRE-RESISTANT FOR 30 MINUTES IN ACCORDANCE WITH THE RECENT HARMONISED STANDARD BS EN. SAFETYFIRECASE - Code CSF 500 Volume: 11 litres - 4 one litre bottles. External dimensions: 340x340x400 mm (W x D x H). Internal dimensions: 200x200x265 mm (W x D x H). Weight: 18 kg approx. TECHNICAL FEATURES Electro-welded, monolithic support frame in electrostatically galvanized sheet steel. Exterior finished in epoxy resin, thermo-set at more than 200 C and with average thickness not less than 90 microns. Signs according to ISO 3864. Operation and service manual according to DIN V 8418. SAFETY FEATURES Sandwich -construction thermal insulation panels with Type 30 fire resistance class according to BS EN. Fire resistance certified by an independent testing organisation after conducting a FIRE TEST performed according to the recent BS EN standard. AUTOMATIC doors closing when the room temperature exceeds 50 C. Self-sealing inlet and outlet ventilation ports with automatic closure systems. The closure systems are maintenance-free for a long working life and reliability. 30 mm wide, mineral reinforced fibre, graphite based, intumescent seals which automatically expand when the ambient temperature exceeds a safe level (DIN 4102). They are located on both the door edges and door frame to ensure excellent fireproofing. Non-sparking door hinges run along the whole length of the door and do not need adjustment. OPTIONAL ACCESSORIES Wall fixing system - Code CSF 550 Trolley - Code CSF 560 Bottom spillage trough - Code CSF 570 SAFETYFIRECASE PORTABLE, PRACTICAL, SAFE. Authorized dealer: We reserve the right to introduce technical changes to the instruments without notice, according to changes in legislation or technological improvements.