Inverted Bucket Steam Traps

Similar documents
CRU-S Series Stainless Steel Condensate Recovery Unit

INSTALLATION AND MAINTENANCE INSTRUCTIONS. IM US March RediHeat. Table Of Contents. I. Installation RediHeat Start-Up Procedure 4

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

PA ma Loop Powered Level Preamplifier

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

Installation and Maintenance "L" and "LS" Series

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Universal control panel incorporating SIMS TM technology HTG Installation and Maintenance Instructions

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Niles Steel Tank Hot Water Generator Installation and Operation Manual

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

13-1. Temperature Regulator

Installation and Testing of Inverted Bucket Steam Traps Manual

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION, OPERATION

INSTALLATION, OPERATION

LONGONI ENGINEERING SRL

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

User s Information Manual

205 Control Installation and Maintenance Instructions

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Series 1140 and 1141 Temperature Regulators

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Silhouette. Feedwater Heater. Boiler Feedwater

569, 570, 571, 572 Series

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

INSTALLATION & OPERATING INSTRUCTIONS

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

569, 570, 571, 572 Series

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

FT14 Ball Float Steam Trap (Screwed)

Model: 1100 Float-Controlled Condensate Trap, PN 25

Chapter 2.3: Steam System

Series B Inverted Bucket Steam Traps

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

TITAN FLOW CONTROL, INC.

User s Information Manual

Instructions for installation and use English. More documents on: H B /09

BK 45 BK 45-U BK 45-LT BK 46

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Liquid Drainers LIQUID DRAINERS

568X, 587X, 588X Series

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Proweld Equipment Owner & Maintenance Manual Maxiplast (Widos Shop 6)

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Instruction Manual. Pharma-line ESE02198-EN Original manual

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

FUN I / FUN U FUN I MCP / FUN U MCP FUN V / FUN V MCP

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

Hoffman Specialty General Catalog

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

TECHNICAL DATA. Wet 26a. February 22, 2009

INSTALLATION, OPERATION

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

EasiHeat Mechanical Installation and Commissioning Instructions

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME


AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

INFINITY FLUIDS CORPORATION

Proweld Equipment Owner & Maintenance Manual

Steam Traps and Steam Specialties

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

General safety precautions English

Transcription:

INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use / application. i) The products have been specifically designed for use on steam, air or water/condensate. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections and protective film from all name-plates, where appropriate, before installation on steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1. Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1. Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1. Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and / or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and / or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high / low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal permit to work system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post warning notices if necessary. 1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done.

1.1 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures in excess of 00 C (52 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to 'Maintenance instructions'). 1.1 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 1.1 Working safely with cast iron products on steam Cast iron products are commonly found on steam and condensate systems. If installed correctly using good steam engineering practices, it is perfectly safe. However, because of its mechanical properties, it is less forgiving compared to other materials such as SG iron or carbon steel. The following are the good engineering practices required to prevent waterhammer and ensure safe working conditions on a steam system. Safe Handling Cast Iron is a brittle material. If the product is dropped during installation and there is any risk of damage the product should not be used unless it is fully inspected and pressure tested by the manufacturer. Steam Steam Mains - Do's and Dont's: Prevention of tensile stressing Pipe misalignment: Installing products or re-assembling after maintenance: Do not over tighten. Use correct torque figures. 1 2 6 2 1 8 Flange bolts should be gradually tightened across diameters to ensure even load and alignment. 5 Prevention of water hammer Steam trapping on steam mains: 0-50 metre intervals Steam Gradient 1:100 Trap set Gradient 1:100 Trap set Trap set Steam Condensate Condensate Condensate 2

Thermal expansion: Limit rods Small Large Short distance Fixing point Axial Axial Medium distance Fixing point Limit rods Small Large Installation 1.) Before installing trap, the inlet piping should be carefully blown down to remove any existing pipe debris. CAUTION: Before Installation, inspection or maintenance, ensure that the steam inlet and outlet piping valves are closed and the trap isolated to prevent personnel injury. 2.) Check the maximum operating pressure stamped on the nameplate. If the actual system operating pressure is greater than the maximum operating pressure of the trap, a trap having a higher operating pressure must be substituted..) Depending upon the type, trap body pattern will require either horizontal or vertical piping. Install trap with bottom and/or arrow cast on trap pointing downward so that the inverted bucket can freely move in a vertical plane..) Locate the trap below and close to the drain point where it is accessible for inspection and servicing. A pipeline strainer should be fitted ahead of the trap along with isolation valves and pipe unions as required by good piping practices. 5. To prevent backflow, a check valve is recommended after the trap when condensate is elevated. With a modulating pressure condition, or on superheated steam service, a check valve should also be located ahead of the trap inlet to prevent prime loss. 6. When draining equipment controlled by modulating valves with vacuum breakers, and whenever greater air venting capability is desired, an auxiliary thermostatic air vent should be fitted in parallel above the trap.. Any bypass piping should have reduced capacity and be installed above the trap to reduce the chance of prime and steam loss. However, unless continuous service is necessary, bypass piping should be avoided whenever possible. 8. On startup, slowly open inlet valve, then outlet valve, to establish a prime or water seal around the inverted bucket inside the body. If trap does not have enough startup condensate to prime itself, shut if off and manually pour water into the body. Problems with prime loss may indicate that the trap is oversized for the load and it should be changed to a smaller size. 9.) When installed outdoors, trap will not freeze in continuous operation but can be damaged if steam pressure is lost or inadvertently turned off. To prevent freezeup damage, the body must be drained manually or can be protected automatically with a Spirax Sarco Thermoton set for 5 F opening temperature. Inspection and Maintenance Spirax Sarco Inverted Bucket Traps for horizontal piping may be inspected and cleaned without removing the trap from the line. Vertical threaded body types require a union after the outlet to permit disassembly. 1.) Flash steam - When condensate at steam temperature is discharged to a lower pressure, part of it reevaporates, forming flash steam. This should not be confused with live steam when inspecting the operation of steam traps. 2.) To clean or inspect the trap inlet port - Remove any obstruction or debris from the inlet cavity. If the trap is fitted with a strainer, make sure the screen perforations are clear and unobstructed..) To clean, inspect or replace the trap mechanism a.) Remove the cover bolts and cover. b.) Remove all dirt and incrustation from the mechanism, trap body and cover. Inspect the body and cover for condensate corrosion. c.) Inspect the valve head and seat for damage and/or signs of wear or wiredrawing, and replace is required. To remove the seat, detach the bucket arm by removing the pin and unscrew the seat. d.) Inspect the vent hole in the bucket and make sure it is clear and fully open. e.) Remove the old gasket from the cover and/or body and replace with a new gasket. f.) Reinstall the cover and mechanism to the trap body and tighten the cover bolts. It is recommended that the cover bolts be retightened after the trap has been operating for a few hours to account for gasket relaxation and thermal expansion.

Hookup for Horizontal Inverted Bucket Trap Check Valve if Condensate is to be Elevated Air Vent if Required Bypass Air Vent if Required Bypass Hookup for Vertical Inverted Bucket Trap Check Valve Required if Inlet Steam Pressure is Variable or Superheated Check Valve if Condensate is to be Elevated Hookup for SIB Bucket Trap Air Vent Head Travel When installing a bucket trap air vent, the following head travels are required when set at 0 F to 80 F ambient. The head travels are measured along the centerline of the head. The head travels are adjusted by bending the bimetallic strip. Scale Bimetal Strip B12, B22 Model Travel Tolerance B12, B22 /6 +0.000-1/6 B2 /6 ± 1/6 B2, B52 /2 ± 1/6 B2, B2, B52

1b B1, B2 1 B2, B22, B, B2 B12 B22 B, B2, B5, B52 (Optional) B2 B2 B52 5 1a Use high temperature adhesive/sealant on air vent seat threads (Ex. Loctite 22) 2 Torque Values (Ft lbs) Cover Bolts Size and Models 11-1 1/2, / B1X or B1H Series 5-9 / B2 Series 21-2 1 B Series 55-59 1-1/ B Series 80-85 2 B5 Series Valve Seats 11-1 1/2 B1X-5, 125, 180, 250 28-1 1/2, / B1H Series; / B2-125, 180, 250; 1/2, / B1X-15, 0 6-50 / B2-15, 0; 1 B-5, 125, 180 66-0 250, 1 B-15, 0 195-205 1-1/ B Series; 2 B5-5, 125, 180, 250 250-260 2 B5-15, 0 Air Vent Seats 11-1 All Models Plug 28-1/2, / B1HS Series 28- / B2S Series 5-58 1 BS Series 60-66 1-1/ BS Series 68-5 2 B5S Series Note: Traps with optional strainers use the same cover bolts and seat torque requirements (Optional) 6 Use pipe joint compound on screen plug threads Part No. Description 1 Cover 1a Cover Gasket 1b Cover Cap Screws 2 Body Air vent Complete Mechanism 5 Stn. Stl. Bucket 6 Stn. St. Strainer 5

Spirax Sarco Applications Engineering Department Toll Free at: 1-800-88-11 SPIRAX SARCO, INC. 1150 NORTHPOINT BLVD. BLYTHEWOOD, SC 29016 PHONE 80-1-2000 FAX 80-1-2200