Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Similar documents
Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Hoffman Specialty General Catalog

Liquid Drainers LIQUID DRAINERS

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Inverted Bucket Steam Traps

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

THERMOSTATIC STEAM TRAPS

Spirax-Sarco Industrial Thermostatic Steam Traps

STEAM TRAPS

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

STAINLESS STEEL TRAP VALVE STATION

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Silhouette. Feedwater Heater. Boiler Feedwater

UNIVERSAL STYLE STEAM TRAPS WU450 Series

LIQUIDATOR UMT-TD Series Thermodynamic

MFP14 Automatic pumps. for condensate and other industrial fluids

LIQUIDATOR 450 SERIES

Our Know-How. Your Peace of Mind. Steam Solutions

Catalog No. 108-C. Steam Traps

MFP14 Automatic pumps for condensate and other industrial fluids

THE THERMOSTATIC STEAM TRAP

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Economical and simplified solutions that offer quality and optimum steam trap service.

Thermostatic Steam Traps

MECHANICAL STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Pure Performance For Steam Mains and Tracers

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

FT14 Ball Float Steam Trap (Screwed)

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

The right trap for the right application.

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Series B Inverted Bucket Steam Traps

Chapter 2.3: Steam System

INSTALLATION, OPERATION

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Bringing Energy Down to Earth

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Installation and Maintenance "L" and "LS" Series

Hydrocarbon & Chemical Processing Solutions

THERMODYNAMIC STEAM TRAP

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Steam Traps and Steam Specialties

PF Series. Piston Actuated Valves

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

CD-33/CD-33S Controlled Disc Steam Traps

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Pump & Trap Combinations

STEAM CONSERVATION GUIDELINES

ESCO. Committed. Group of Companies. to help conserve Steam Energy

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Installation and Testing of Inverted Bucket Steam Traps Manual

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

So far 2010 is proving to be

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Disc Type Steam Trap TSD-42

Steam Trap Inspection Methods And Steam Cost Analysis

UNIFIED FACILITIES GUIDE SPECIFICATIONS

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Blowdown Separator & Aftercoolers

High Capacity Instantaneous Steam Fired Water Heater

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Thermostatic Expansion Valves Type TR 6

Documento Descargado desde:

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

PIP PNE00004 Steam Trap Guidelines

Packaged Semi-Instantaneous Steam Fired Water Heater

INSTALLATION, OPERATION

Air Vents for Hot and Chilled Water Systems

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Transcription:

Inverted ucket Steam Traps for efficient condensate drainage of industrial and HVC equipment

Inverted ucket steam traps The proper drainage of condensate is essential to efficient steam system operation. Condensate, if allowed to collect in the steam system, creates several problems: uild-up of condensate in steam mains and headers can eventually lead to water hammer which can seriously damage the steam system and create safety problems. Condensate which is not removed may eventually back up into the steam space of process equipment, consequently reducing efficiency. Inverted ucket steam traps rely on the difference in density between steam and condensate to drain condensate as it forms. This keeps the steam space free of condensate to provide maximum system efficiency. These durable traps are designed to withstand corrosion, dirt, and water hammer to provide long lasting service. On applications where air and non-condensible gases are present, an external air vent can be fitted to assist the normal operation. Spirax Sarco offers a full range of Inverted ucket steam traps to handle steam pressures up to 900 psig. How it works s condensate reaches the trap, it forms a water seal inside the body. The weight of the bucket keeps the valve off its seat so condensate can flow around the bottom of the bucket and out of the trap. Under low load or superheat conditions, the trap may need to be primed with water before system startup (1). When steam enters the underside of the bucket, the bucket becomes buoyant and rises. This positions the lever mechanism such that the main valve snaps shut (2). The bucket will lose its buoyancy as the enclosed steam condenses due to radiation losses, and steam escapes through the vent hole. Once this happens, the weight of the bucket will pull the valve off its seat and the cycle is then repeated (3). ny air reaching the trap will also give the bucket buoyancy and close the valve, preventing condensate flow. The small vent hole in the bucket will bleed air into the top of the trap. The vent hole is of small diameter to reduce steam loss and thus will vent air very slowly. Under startup conditions, this is further compounded by the low differential pressures present. This can lead to waterlogging of the plant and subsequent poor heat transfer. separate external air vent is normally required to ensure speedy and efficient startup of a steam plant. bimetal air vent assist can be added to some models to help with cold startup air. 1 2 3 2

Venting of non-condensibles through the vent hole in the top of the bucket provides continuous operation. User benefits Resists water hammer with durable design. Flexible choice of connections: screwed, socket weld or flanged. Simple installation and maintenance with in-line horizontal piping connections. Compatible with a wide array of systems with pressure ranges up to 900 psig. ll working parts are stainless steel providing good resistance to corrosion and wear. odies available in cast iron, steel and stainless steel to meet specific requirements. vailable with either horizontal or vertical flow patterns for piping convenience. ecause condensate flows under the bucket, dirt is kept away from the orifice until the valve is fully open. Inverted ucket steam trap overview Model Sizes (inches) Pipe Configuration ody Material 1/2 3/4 1 1-1/4 1-1/2 2 NPT SW FLG In-line Cast Cast Stn. Horiz. Vert. Iron Steel Steel Strainer ir Vent Check Valve TIS # Series x x x x x x x x Series x x x x x x x x HM34 x x x x x x x Series x x x x x x x x 900 Series x x x x x x x x SI30 x x x x x x SI45 x x x x x x UI30 x x x x x Swivel Connector x Optional Optional 2.407 2.401 Standard 2.404 Standard 2.402 Standard 2.403 2.410 Standard 2.411 2.412 3

Typical applications for Inverted ucket steam traps High Pressure Steam Mains Instant removal of condensate prevents water hammer and improves steam quality. Steam Separator Wet steam can damage equipment and reduce process efficiency. Spirax Sarco separator efficiently knocks out condensate droplets in the steam flow. This condensate must be continuously drained from the separator to prevent it from becoming re-entrained in the steam flow. Spirax Sarco Inverted ucket steam traps discharge condensate as it forms to prevent this from happening. Laundry quipment Laundry equipment uses steam for cleaning and pressing garments. Inefficient condensate drainage will not allow the proper cleaning drying and pressing temperatures to be achieved. Spirax Sarco Inverted ucket steam traps keep the equipment operating smoothly by draining condensate as it forms. 4 Need to know 1. The steam pressure at the trap after any pressure drop through the control valve or equipment. 2. The distance the condensate must be lifted after the trap. Rule of thumb: 2 feet of lift equals 1 psi back pressure (approximately). 3. ny other possible sources of back pressure in the condensate return system. For example: Condensate taken to a pressurized deaerator tank or flash recovery vessel. Local back pressure due to discharge of numerous traps close together into an undersized return. 4. Quantity of condensate handled. Obtained from: Measurement Calculation Manufacturer s data 5. Safety Factor that is dependent upon particular application, typical examples as follows: Steam Mains 2:1 Tracers 2:1 Non-Modulating 2:1 Modulating over 30 psi 3:1 Modulating under 30 psi Steam trap selection and sizing Size trap at full load and 1/2 psi differential Rule of thumb: Use a factor of 2 on everything except Temperature Controlled ir Heater Coils and Converters, and Siphon pplications How to size The difference between the steam pressure at the trap inlet and the total back pressure, including that due to lift after the trap, is the differential pressure. The quantity of condensate should be multiplied by the appropriate safety factor to produce the sizing load. The trap may now be selected using the differential pressure and the sizing load. Note: The inlet pressure to the steam trap should never exceed the of the selected trap, regardless of differential pressure. xample steam trap is required to drain lb/h of condensate from a Unit Heater receiving steam at psig. There is a lift after the trap of 10 ft. Inlet Pressure psig Lift 10 ft. = 5 psi (approximately) Therefore, ifferential Pressure psi - 5 psi = 95 psi Quantity lb/h Safety Factor 2:1 Sizing Load 4,000 lb/h 1-1/4" 4-125 will handle 7,590 lb/h at 95 psi differential pressure.

Inverted ucket steam trap range Series The Series Inverted ucket steam traps are traditional cast iron, horizontal flow products. The stainless steel bucket and valve are resistant to corrosion and water hammer. pressures are available up to 250 psig with capacities to 20,000 lb/hr. Series nother traditional cast iron product, the Series utilizes the popular bottom in/top out flow pattern. The stainless steel bucket and valve are resistant to corrosion and water hammer. pressures are available up to 250 psig with capacities to 20,000 lb/hr. Series Model 1H 2 3 4 5 Size 1/2", 3/4" 3/4" 1" 1-1/4" 2" ody Material Cast Iron NPT Piping Configuration In-Line Horizontal Strainer, ir Vent TIS# 2.407 250 psig Series Model 211 212 213 215 216 Size 1/2" 3/4" 1" 1-1/2" 2" ody Material Cast Iron NPT Piping Configuration In-Line Vertical N/ TIS# 2.401 250 psig Top plug not provided on 1H, 12H, 2, 22, 5, 52. C,C1 C Series imensions (nominal) in inches Size C Weight 1/2" 6.4 4.3 7.0 2.6 6.25 lb 3/4" 7.9 5.3 9.0 3.7 11.5 lb 1" 10.6 7.4 11.0 4.5 27.0 lb 1-1/2" 14.4 9.4 15.0 5.5 59.0 lb 2" 17.0 11.3 18.5 7.2 96.0 lb 20,000 10,000 5,000 3,000 Series imensions (nominal) in inches Size Type C C1* Weight 1/2", 3/4" 1H 5 4 3.3 3.8 3 1.4 6.2 lb 3/4" 2 6.6 5.3 3.5 4.0 4.1 1.9 12.5 lb 1" 3 7.9 5.9 4.4 4.4 4.8 2.2 19.5 lb 1-1/4" 4 9.3 7 5.6 5.4 7.4 2.3 40 lb 2" 5 11.2 8.8 6.3 6.6 10.7 3.4 75 lb *C1 imension for traps supplied with bi-metal air vents (12H, 22, 32, 42, 52) 5-15 4-15 3-15 2-15 1H-15 Series Capacities -125-125 -180-180 -125-180 -125-180 -125-180 20,000 15,000 10,000 7,000 5,000 3,000 1,500 700 500 150 Series Capacities 216, 226 215, 225 213, 223 212, 222 211, 221 24 16 36 12 48 40 32 28 24 28 20 16 12 14 12 22 20 18 10 8 7 10 8 7 6 1 10 125 180 250 8 10 15 20 30 50 70 150 250 5

Inverted ucket s HM34 UI30/UI30H The steel construction of the HM34 makes it a logical choice for systems up to 465 psig. vailable in 1/2" through 1" with threaded or socket weld connections. The stainless steel bucket and valve are resistant to corrosion and water hammer. HM34 Size 1/2", 3/4", 1" ody Material Steel NPT, SW Piping Configuration In-Line Horizontal Strainer is Standard TIS# 2.404 464 psig The UI30 is a sealed inverted bucket steam trap complete with Spirax Sarco s versatile swivel connector for installations requiring horizontal or vertical flow. The swivel connector is ideal for maintaining the proper trap operation. The two-bolt connector design simplifies maintenance and reduces downtime. C (Connector of choice sold separately) F G 500 110 HM34 Withdrawal istance H 1/2 HM 34/6 HM34 imensions (nominal) in inches Size C F G H Weight 1/2" 4.7 4.1 4.0 2.6 3.5 2.6 5.8 lb 3/4" 4.7 4.1 4.0 3.5 4.2 2.6 8.9 lb 1" 7.1 6.3 6.3 5.7 4.7 3.4 22.9lb HM34 Capacities 1 HM 34/12 1 HM 34/10 3/4 HM 34/10 1/2 HM 34/8 3/4 HM 34/8 1 HM 34/8 1 HM 34/5 1/2 HM 34/5 1/2 HM 34/4 1 HM 34/6 3/4 HM 34/7 1/2 HM 34/7 3/4 HM 34/6 8 10 20 30 40 50 60 80 120 170 290 3/4 HM 34/5 UI30 / UI30H imensions (nominal) in inches Size C Weight 1/2" 2.4 3.4 4.9 1.3 3.1 4.8 lb 3/4" 2.9 3.3 4.9 1.3 3.1 4.9 lb 1" 3.5 3.4 4.9 1.3 3.1 5.2 lb UI30 / UI30H Size 1/2", 3/4", 1" ody Material Stainless Steel NPT, SW Piping Configuration In-Line, Swivel Connector Check Valve is Standard TIS# 2.412 Model 30/8 30/7 30/6 30/5 30/4 58 123 174 290 435 psig psig psig psig psig Model 30H/10 30H/8 30H/6 30H/5 58 123 290 435 psig psig psig psig 900 700 500 UI30 / UI30H Capacities UI 30H/10 UI 30/8 UI 30/7 UI 30/6 8 10 20 30 40 5860 80 125 175 290 /8 /6 UI 30/5 /5 UI 30/4 6

team trap range SI30 / SI30H / SI45 The SI30 and SI45 Inverted ucket steam traps are sealed for tamper-proof operation. The all stainless steel construction is highly resistant to corrosion and water hammer. pressures up to 652 psig are available with sizes ranging from 1/2" through 1" and either threaded or socket weld end connections. SI30 / SI30H / SI45 Model SI30 / SI30H SI45 Size 1/2", 3/4" 3/4", 1" ody Material Stainless Steel NPT, SW Piping Configuration In-Line Horizontal Check Valve is Standard (SI45 only) TIS# 2.410 2.411 435 652 psig psig SI30 SI45 C C SI30 imensions (nominal) in inches Size C Weight 1/2" 4.3 3.0 4.9 5.6 3.3 lb 3/4" 4.3 3.0 4.9 5.6 3.3 lb SI30H imensions (nominal) in inches Size C Weight 1/2" 4.3 3.0 6.3 7.0 3.9 lb 3/4" 4.3 3.0 6.3 7.0 3.9 lb SI45 imensions (nominal) in inches Size C Weight 3/4" 4.3 3.3 6.9 7.8 6.5 lb 1" 4.3 3.3 6.9 7.8 6.5 lb Condensate lb/hr 0 Condensate lb/hr Condensate lb/hr 700 500 0.5 770 662 441 221 188 176 154 132 SI45 Capacities ifferential Pressure barg 0.8 1 2 3 4 5 6 8 10 20 30 45 45/10 50 8 10 20 30 40 50 60 80 500 ifferential Pressure psig SI30/12 SI30/12 SI30/10 SI30/10 SI30/8 110 50 7 15 29 44 58 73 116 145 290 435 ifferential Pressure psig 770 662 441 SI30 45/8 SI30/7 SI30/6 45/6 ifferential Pressure barg SI30/8 SI30/7 SI30/6 0.5 1 2 3 4 5 8 10 20 30 SI30H SI30H/12 SI30/12 SI30H/10 ifferential Pressure barg SI30/10 SI30/8 SI30/7 SI30H/7 SI30H/8 SI30/5 SI30H/6 SI30/5 SI30/4 SI30/6 SI30H/5 45/5 SI30/4 350 90 80 70 60 SI30/5 0.5 1 2 3 4 5 8 10 20 30 450 221 188 176 154 132 110 90 80 70 60 50 7 15 29 44 58 73 116 145 ifferential Pressure psig 290 435 Condensate kg/hr 80 70 60 Condensate kg/hr. Condensate kg/hr. 7

Inverted ucket steam trap range /900 Series The and 900 Series of Inverted ucket steam traps are designed for high pressure steam systems with operating pressures available up to 900 psig. The robust forged steel construction with stainless steel internals are resistant to corrosion and water hammer. C Series 900 Series Withdrawal istance Withdrawal C istance Series imensions (nominal) in inches Size C Weight 1/2" 10.6 7.3 8.0 4.7 1.1 40 lb 3/4" 10.6 7.3 8.0 4.7 1.1 40 lb 1" 12.0 8.0 9.0 5.1 1.4 65 lb 1-1/2" 15.8 9.8 12.0 6.6 1.8 110 lb 2" 17.4 11.9 13.0 8.4 2.1 175 lb 900 Series imensions (nominal) in inches Size C Weight 1/2" 12.1 8.0 9.0 5.1 1.4 65 lb 3/4" 12.1 8.0 9.0 5.1 1.4 65 lb 1" 16.1 9.8 12.0 6.6 1.8 110 lb 1-1/2" 16.1 9.8 12.0 6.6 1.8 110 lb 2" 17.7 11.9 13.0 8.4 2.1 175 lb Series Model 621 622 623 625 626 Size 1/2" 3/4" 1" 1-1/2" 2" ody Material Steel Flanged Piping Configuration In-Line Vertical Check Valve is Standard TIS# 2.402 psig 900 Series Model 921 922 923 925 926 Size 1/2" 3/4" 1" 1-1/2" 2" ody Material Steel Flanged Piping Configuration In-Line Vertical Check Valve is Standard TIS# 2.403 900 psig Series Capacities 900 Series Capacities 10,000 8,000 6,000 4,000 3,000 626/32 625/22 625/14 NORTHST Nigel Sewell Columbus, Ohio Hub Office 7760 Olentangy River Road Suite 120 Columbus, OH 43235 Phone: (614) 436-8055 Fax: (614) 436-8479 80 621/12 622/12 621/10 622/10 621/8 622/8 621/7 622/7 626/24 626/20 625/18 626/18 623/16 625/12 623/12 623/10 623/8 8 10 20 30 40 5060 120 450 10,000 8,000 6,000 4,000 3,000 926/18 926/16 923/925/12 923/925/10 921/922/8 8 10 20 30 40 60 80 8 Spirax Sarco, Inc. 1150 Northpoint lvd. lythewood, SC 29016 Phone: (803) 714-0 Fax: (803) 714-2222 www.spiraxsarco.com/us Printed in US 11/04. Copyright 4 Spirax Sarco, Inc.