Parametric Analysis of Surface Condenser for Thermal Power Plant

Similar documents
Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

The Condensate Water Systems

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

REVIEW ON CONDENSER AIR LEAK TEST

Enhancement of COP in Vapour Compression Refrigeration System

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions

Adsorption refrigeration system using waste heat

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Performance Study of Triple Concentric Pipe Heat Exchanger

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Performance investigation of Air-conditioning system using ejector as expansion device

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

η second law = Second law efficiency

System Modeling of Gas Engine Driven Heat Pump

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Condenser Vacuum Improvement and Related Parametric Analysis: A Case Study on A 120MW Thermal Power Plant

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Solar Drying Techniques And Performance Analysis: A Review

Scientific Journal Impact Factor: (ISRA), Impact Factor: Methodology. [Yadav, 3(9): September, 2014] ISSN:

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

"A Case Study of Three Drum Parameter Control in Boiler Using Discrete PID Controller Based on Simulation"

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Compression of Fins pipe and simple Heat pipe Using CFD

A Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER USING AL 2 O 3 MICROPARTICLES

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Comparison of Energy and Cost Analysis of Two Different Industrial Corn Drying Plants Using Solid Fuel

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

AUTOMATION OF BOILERS USING LABVIEW

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

WET POSITION BOOSTER FANS FOR REDUCED POWER CONSUMPTION AND OPTIMIZED ENVIRONMENTAL PERFORMANCE OF POWER STATIONS WITH FGD AND WET STACK

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Performance Optimization of the Evaporative Condenser Design

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Solution of I Mid Term Steam Engineering 6ME5A

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Design and Development of Water Cooled Condenser for Domestic Refrigerator

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

A chimney system Re-designing to increase boiler efficiency against fouling.

Homework Chapter2. Homework Chapter3

Boiler Basics. Design and operation

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

Thermodynamics: Homework A Set 7 Jennifer West (2004)

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

MODERN EVAPORATIVE COOLER

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Experimental Study and Analysis of Condenser Performance under Dual Backpressure Operation Mode

Drying principles and general considerations

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

A Design of Thermoelectric Cooler and Optimization

STUDY OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING DOUBLE PIPE HEAT EXCHANGER

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Transcription:

Research Article International Journal of Thermal Technologies ISSN 2277-4114 2013 INPRESSCO. All Rights Reserved. Available at http://inpressco.com/category/ijtt Parametric Analysis of Surface Condenser for Thermal Power Plant Vikram Haldkar Ȧ*, Abhay Kumar Sharma Ȧ, R.K.Ranjan Ȧ and V.K.Bajpai Ḃ Ȧ Gyan Ganga Institute of Engg.& Tech., Jabalpur, M.P., INDIA Ḃ NIT Kurukshetra (Institute of National Importance), INDIA Accepted 25 November 2013, Available online 01 December 2013, Vol.3, No.4 (Dec 2013) Abstract The thermal power plants are used to generate power. The thermal power plants are designed based on required conditions (like a good quality of steam, pressure and temperature of steam etc.), but actually inlet conditions are not as per the designed conditions. In practical situations, when power plants are installed there are lots of constraints. This tends to reduce or increase output power and heat rate of thermal power plants. Due to these conditions, the designed power and heat rate are never achieved. Variations in the power outputs from plant are always a matter of disputes. So the parameters for power and heat rate are generated for different conditions of condenser pressure, flow rate of water through the condenser, Temperature difference. On the basis of site measurement and design data collection performance of the Condenser unit can be evaluated. These evaluations indicate that if operating conditions vary, then power output and heat rate also vary. This paper deals with the factors or parameters which reduced the efficiency of the condenser and power plant. Keyword: Flow rate, condenser, Power Output, Performance analysis, vacuum, energy efficiency Introduction 1 The condenser is a heat transfer device or unit used to condense a substance from its gaseous to its liquid state, typically by cooling it. In doing so, the latent heat is given up by the substance, and will transfer to the condenser coolant. Use of cooling water or surrounding air as the coolant is common in many condensers. The main use of a condenser is to receive exhausted steam from a steam engine or turbine and condense the steam. The benefit being that the energy which would be exhausted to the atmosphere is utilized.a steam condenser generally condenses the steam to a pressure significantly below atmospheric. This allows the turbine or engine to do more work. The condenser also converts the discharge steam back to feed water which is returned to the steam generator or boiler. In the condenser the latent heat of condensation is conducted to the cooling medium flowing through the cooling tubes. In practical situations, when power plants are installed there are lots of constraints. This tends to reduce or increase output power and heat rate of thermal power plants. Due to these conditions, the designed power and heat rate are never achieved. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system 86.27% and then condenser and stack gas *Corresponding author Vikram Haldkar is M.Tech. Scholar; Abhay Kumar Sharma and R.K.Ranjan are working as Associate Professors and V.K.Bajpai is working as Professor 13.73%. In addition, the calculated thermal efficiency was 38.39 % while the exergy efficiency of the power cycle was 45.85% (Ankur Geetea et al, 2013). Steam power plants use basically two types of cooling systems: open-cycle and closed cycle. Open-cycle or oncethrough cooling systems withdraw large amounts of circulating water directly from and discharge directly to streams, lakes or reservoirs through submerged diffuser structures or surface outfalls. An open-cycle system depends on the adequate cool ambient water to support the generation at full capacity. A closed-cycle cooling system transfers waste heat from circulating water to air drawn through cooling towers. Conventional wet cooling towers depend on evaporating heat exchange and require a continuous source of fresh water to replace evaporation losses. The ability of cooling towers to provide cold water to steam condensers of a thermoelectric unit decreases with increasing air temperatures and, in case of wet cooling tower, increasing humidity (Mirjana et al, 2010). Description Basically, a condenser is a device where steam condenses and latent heat of evaporation released by the steam is absorbed by cooling water. Thermodynamically, it serves the following purposes with reference to the P-v diagram shown in Figure 1. Firstly, it maintains a very low back pressure on the exhaust side of the turbine. As a result, the steam expands to a greater extent and consequently results in an increase in available heat energy. The shaded area 155

Vikram Haldkar International Journal of Thermal Technologies, Vol.3, No.4 (Dec. 2013) shown in the P-v diagram exhibits the increase in the work obtained by fitting a condenser unit to a non-condensing unit for the same available steam properties. In the P-v diagram, line 4-5 is non-condensing line when the condenser unit is -5 notisappli condensing line when the condenser is used Secondly, the exhaust steam condensate is free from impurities. Thermal efficiency of a condensing unit is higher than that of a non-condensing unit for the same available steam properties. Figure 1: Key components of a thermal power plant working on a Rankine Cycle Literature Survey Mirjana, S LAKOVIC and Dejan D. MITROVIC in 2010 focused on impact of cooling water temperature on energy efficiency of power plant, increasing pressure in the condenser of 1 kpa, efficiency decreases to 1.0-1.5% using Simulator based on IAPWS-IF97.considering that in this particular case the reduction is 1.2%, dependence of the energy efficiency in the function of the cooling water temperature rise is obtained. The condenser heat transfer rate and pressure in the condenser are given for variable cooling water temperature and flow rate, the specific heat rate change due to the change of condensing pressure, and the specific heat rate change due to the cooling water temperature change. Finally, the energy efficiency for the reference plant is given as the function of the change in condensing pressure. Ajeet Singh Sikarwar, Devendra Dandotiya and S.K. Agrawal in 2013 Study about the factors or parameters which reduced the efficiency of condenser Using Analysis of ATPS and finalizes three causes which affecting the performance of condenser are deviation due to inlet temperature of cold water, deviation due to cold water flow, deviation due to air ingress /dirty Tube, particular in this study the efficiency of a power plant will reduce to 0.4% by these deviation in condenser. Milan V.Sanathara, Ritesh P.Oza and Rakesh S.Gupta in 2013 focused on the influence of cooling water flow rate and temperature on the condenser performance, and thus on the specific heat rate of the coal fired plant and its energy efficiency using Parametric Analysis Method. As cooling water flow decreases the vacuum inside the condenser. This increased condenser pressure will decrease the power output of LP turbine which is not advisable. From mathematical model and analysis author proved that energy efficiency of condenser reduces when cooling water inlet temperature increases. Amir vosough, Alireza falahat, Sadegh vosough, Hasan nasr esfehani,azam behjat and Roya naseri rad in 2011 to identify and quantify the sites having largest energy and exergy losses at cycle Using Energy and Exergy Analysis Method. In addition, the effect of varying the condenser pressure on this analysis will also be presented with the limits of turbine & condenser temperature and design, the minimum allowable condenser pressure should be chosen to produce maximum efficiency and output power. This pressure should be always controlled during the power plant operation. The maximum energy loss was found in the condenser where 60.86% of the input energy was lost to the environment. The exergy destruction in the condenser was 13.22% and thermal and exergy efficiency 38.39 %, 45.85. Ankur Geete and A.I. Khandwawala in 2013 used Exergy Analysis Method for create relation between correction Curves for power & heat rate are generated for different condition of condenser back pressure. Prashant Sharma, SPS Rajput and Mukesh Pandey in 2011 focused on Exergetic Optimization of Inlet Cooling Water Temperature of Cross Flow Steam Condenser, It is found that optimum cooling water temperature decrease with decrease of condenser pressure Using Exergoeconimic Analysis Method for minimized the using the Exergy method. As the upstream mass flow rate increase, the optimum coolant temperature and exergy efficiency decreases, Pressure drop is also increased with increase of cooling water flow rate using MAT Lab program. With decrease of condenser pressure from 0.18 bar to 0.10 bar optimum cooling water temperature is also decrease from 34 to 21, and exergy destruction at 21 decreases from 41755 kw to 30263 kw. Operating temperature of cooling water cannot be increased more than 34. At this temperature, exergy destruction is 27350kW and exergy efficiency is 37.1%. A.Dutta and A.K. Das in 2013 had worked upon the Loss factor and Efficiency of surface condenser and result found out At a particular load and condenser pressure, with the decrease in temperature rise in cooling water the condenser efficiency decreases. Similarly, at higher temperature rise in cooling water the condenser offers higher efficiency. At a particular load and condenser pressure, Loss Factor (LF) increases with decrease in temperature rise in cooling water. At a particular load and condenser pressure, Loss Factor decreases with increase in efficiency. It has been also noted that the efficiency is maximum when the Loss Factor equals to one. Vosough Amir and Sadegh vosough in 2011 focused on Energy and Exergy Method for power plant Efficiency In the considered power cycle, the maximum energy loss was found in the condenser. Next to it was the energy loss in the boiler system. The major source of exergy destruction was the boiler system where chemical reaction is the most significant source of exergy destruction in a combustion chamber. Exergy destruction in the combustion chamber is mainly affected by the excess air fraction and the temperature of the air at the inlet. Element of Surface Condenser The heat transfer mechanism is the condensation of saturated steam outside the tubes and the heating of the 156

condenser pressure(bar) Vikram Haldkar International Journal of Thermal Technologies, Vol.3, No.4 (Dec. 2013) circulating water inside the tubes. Thus, for a given circulating water flow rate, the water inlet temperature to the condenser determines the operating pressure of the condenser. As this temperature is decreased, the condenser pressure will also decrease. As described above, this decrease in the pressure will increase the plant output and efficiency. Steam condensation enables a vacuum and non-condensable gases will migrate towards the condenser. The non- condensable gases consist of mostly air that has leaked into the cycle from components that are operating below atmospheric pressure. These gases are also formed by the decomposition of water into oxygen and hydrogen. These gases must be vented from the condenser for the following reasons: (a) The gases will increase the operating pressure of the condenser; this rise in pressure will decrease the turbine output and efficiency. (b) The gases will blanket the outer surface of the tubes. This will severely decrease the heat transfer rates of the steam to the circulating water, and pressure in the condenser will increase. (c) The corrosiveness of the condensate in the condenser increases as the oxygen content increases. Thus, these gases must be removed in order to enhance the life of components. Comparison of design and operating parameter show in table No 1 its show the various key value which effecting performance of condenser. Table No 1 Comparison between Designing & operating parameter Parameter Design Operating Condenser vacuum 694mmhg 612mmhg Condenser TTD 4.8 C 19.8 C Condenser Effectiveness 62.50% 30.76% C.T. Range 8 C 8.8 C C.T. Approach 6 C 5.5 C Effectiveness 57% 61% Evaporation losses 21.33 m³/h 20.03 m³/h Make up water consumption 4.2666 m³/h 4.006 m³/h Cooling water rate 1800 m³/h 1536.45 m³/h Turbine back pressure 0.1bar 0.21bar Turbine work 952.6kW 884.9kW Cycle Efficiency 36.70% 34% Specific steam consumption 28.08TPH 30.53TPH Steam Rate 3.77 kg/kwh 4.068 kg/kwh Heat rate of turbine 9718.3 kj/kwh 10566.22 kj/kwh fuel consumption 5805 kg/h 6300 kg/h Result and Discussion Cooling water parameters influence on the condenser performance Condenser heat transfer rate strongly depends on condens- -ing pressure, cooling water flow rate and temperature. In an ideal situation, when the venting system properly removes air from the steam condenser, the achievable condensing pressure is determined by temperature of the cooling water, as it is mentioned above. For the steam power plant with closed cycle cooling system, cooling water temperature is determined by natural water source or ground temperature. This means that cooling water temperature is changing with weather conditions in particular region, and cannot be changed in order to achieve better condenser performances (i. e. higher vacuum in the condenser). Still, cooling water temperature directly affects condenser performances. Suitable parameter for on-line control is cooling water flow rate, and it can be varied in a wide range, with appropriate circulation pumps. During plant operation the objective is to operate at the optimum cooling water flow rate, which depends on cooling water temperature and power demand. In that manner, cooling water temperature and flow rate are considered variable parameters in the simulation of the plant operating conditions. Condensing pressure and cooling water temperature With cooling water temperature rise, the mean temperature difference in the condenser decreases, and condenser heat transfer rate for the same condensing pressure will also decrease. It means that this particular condenser is designed at its maximum heat transfer rate and with increased cooling water temperature it cannot achieve required value. In this way, the question of the valid designed parameters is opened. Increasing of cooling water flow rate will increase the condenser heat transfer rate for the given cooling water temperature. Condensing pressure dependence on cooling water temperature is obtained for the given water flow rate and steam load of the condenser. Steam load is considered constant, in order to obtain a clear illustration of this dependence, as it is shown in figure 2. It is obvious that with cooling water increasing, pressure in the condenser will also increase. 0.25 0.24 0.23 0.22 0.21 0.2 0.19 0.18 0.17 0.16 0.15 29 30 31 32 33 34 35 cooling water temperature(ºc) Figure 2 variation of condenser pressure with cooling water temperature 157

condenser pressure (bar) condenser TTD Vikram Haldkar International Journal of Thermal Technologies, Vol.3, No.4 (Dec. 2013) Steam load of the condenser With cooling water temperature increasing, in order to maintain designed heat transfer rate of the condenser, condensing pressure will increase. As this plant is working under turbine-follow mode, the turbine governor will increase the throttle and exhaust flows in order to set the generated power at the designed level, but with increasing of heat rate, Those results are identical to experimental results for similar plant given in literature (Mirjana et al, 2010), the steam load of the condenser dependence on condensing pressure, at a constant cooling water temperature as for different values of cooling water flow rate. Condenser operating conditions influence on the plant performances After data analysis result is show that with increasing of condensing pressure and flow rate of the cooling water, steam flow through the condenser, and thus through the low-pressure turbine is increasing. This will increase net power output. This increasing of the net power output, however, is correlated to the increasing of the heat rate. Specific heat rate of 0.11bar, efficiency decreases to 2.0-2.7% and considering that in this particular case the reduction is 2.7%, dependence of the energy efficiency in the function of the cooling water temperature rise is obtained and is shown in figure- 3. Cooling water temperature rise causes the reduction of energy efficiency and power of steam power plants. The problem is more severely set for plants with closed-cycle cooling system in comparison to the plant with an open cycle cooling system. Dry bulb temperature, the wet bulb temperature, the atmospheric pressure, flow rate of the circulating water, the characteristic of cooling tower fill, the resistance coefficient of the parts in a tower, and the working condition of a water distribution system and so on, can affect the outlet water temperature of the cooling tower(mirjana et al, 2010). It means that cooling water temperature is changing in a much wider range in one day in comparison to once-through cooling system. Condenser TTD and cooling water temperature The analysis is show that condenser TTD is function of water temperature, in the figure-4 show that the condenser TTD is increase with increasing the temperature of inlet cooling water in condenser and reduce the condenser performance. Specific heat rate change due to condensing pressure change, those results are identical to experimental results for similar plant given in literature (Mirjana et al, 2010). With decreasing of the pressure in the condenser, specific heat rate decreases. With pressure decreasing to bellow the point where the exhaust annulus becomes choked, excessive condensate sub-cooling will result, tending to reduce the improvement in heat rate resulting from the lower condensing pressure. Condensate sub-cooling is defined as the saturation temperature corresponding to the pressure in the condenser minus the condensate temperature in the hot well. 25 20 15 10 5 0 29 30 31 32 33 34 35 cooling water temperature(ºc) Energy efficiency 0.25 0.2 0.15 0.1 0.05 0 33.5 34 34.5 35 35.5 36 36.5 37 cycle efficiency % Figure 3 variation of cycle efficiency with condenser pressure Using the known assumption, from the literature (Mirjana et al, 2010), that with increasing pressure in the condenser Figure 4 variation of condenser TTD with cooling water temperature Conclusion In this paper, causes which effecting the performance of condenser are deviation due to cooling water inlet temperature, deviation due to water flow rate and deviation due to condenser pressure in energy efficiency of plant is consider.eventually this paper find the total efficiency of a power plant will reduce 2.7% by all these deviation in the condenser and by overcome these three reasons, the performance of power plant can be rises with a good level. References Mirjana,S LAKOVIC and Dejan D. MITROVIC (2010), Impact of the Cold End Operating Conditions On Energy Efficiency Of The Steam Power Plants, Vol. 14, Suppl., pp. S53-S66 158

Vikram Haldkar International Journal of Thermal Technologies, Vol.3, No.4 (Dec. 2013) Ajeet Singh Sikarwar, Devendra Dandotiya, Surendra Kumar Agrawal (2013), Performance Analysis of Surface Condenser under Various Operating Parameters, International Journal of Engineering Research and Applications, Vol. 3, Issue 4,pp. 416-421 Milan V. Sanathara, Ritesh P. Oza, Rakesh S. Gupta (2013), Parametric Analysis of Surface Condenser for 120 MW Thermal Power Plants, International Journal of Engineering Research & Technology,Vol. 2 Issue 3,pp.1-8 Amir vosough, Alireza falahat, Sadegh vosough,hasan nasr esfehani,azam behjat and Roya naseri rad(2011),improvement Power Plant Efficiency with Condenser Pressure, International Journal of Multidisciplinary Sciences and Engineering, Vol. 2, No. 3, pp.38-43 Ankur Geetea and A. I. Khandwawala (2013), Exergy Analysis of 120MW Thermal Power Plant with Different Condenser Back Pressure and Generate Correction Curves, International Journal of Current Engineering and Technology,Vol.3, No.1,pp.164-167 Prashant Sharma, SPS Rajput and Mukesh Pandey (2011),Exergetic Optimization of Inlet Cooling Water Temperature of Cross Flow Steam Condenser, Emerging Technologies 2(1): 144-147 ISSN No. (Online):2249-3255 Hardik.B.Patel, N.S.Mehta Optimum Inlet Temperature in Shell and Tube Condenser Using Exergy Method, Advanced Engineering Research and Studies E-ISSN2249 8974 A.Dutta, A. K. Das, S. Chakrabarti (2013), Study on the effect of cooling water temperature rise on loss factor and efficiency of a condenser for a 210 MW Thermal power Unit, Vol 3, Special Issue 3: ICERTSD 2013, pages 485-489 Vosough Amir and Sadegh vosough(2011), Consideration the Important Factor to Power Plant Efficiency, International Journal of Multidisciplinary Sciences and Engineering,Vol. 2, No. 9,pp.56-59 Prashant Sharma, SPS Rajput, Mukesh Pandey (2012), Energy destruction analysis of X-type shell and tube single segmental baffle steam condenser with various operating conditions, International Journal of Latest Research in Science and Technology, Vol.1, Issue 1,pp.49-54 159