Sound Cover [ , , , ]

Similar documents
Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

GETZ MANUFACTURING PART # CYLINDER DRYER

User s Manual and Operating Instructions

MaxLite LED MICRO-T PANEL

20 High velocity Air

SYSTEM CONTROL KIT Model: CK-41P

Industrial Vacuums, Inc

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

COMBUSTION AIR SYSTEM

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

User s Manual and Operating Instructions

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Air Pump Up to 800 gallons

Mold Alert... Operation Manual P0270

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

TrueClean ToteCleaner

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

No Touch Door Release Exit Sensor ACA-NTEB

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

installation instructions Fan Tray System FTA-3/FTA-6

FLCH4R Garage and Utility Electric Heater

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Service Parts, Kits and Accessories

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

TrueClean ToteCleaner

Manual Parts Washer. Operating Instructions & Warranty Information

200/2000 Series Casework

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

18 INCHES, OSCILLATING STAND FAN

MODEL # PUMA G, 3-SPEED TRANSPORTABLE AIR MOVER

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

INSTRUCTION MANUAL HS-229G

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL


Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

PowerMax Diesel Upgrade For PowerStroke Engines

Specifications. Dimensions 32" x 10" x 15" Cage Wire Thickness 3 / 16 " Page 2 For technical questions, please call

Patent Pending invent for New Construction

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

User s Manual and Operating Instructions

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

120 VAC SYSTEM CONTROL KIT

REPLACEMENT PARTS LIST WARNING

Heater Installation Kit

6-Gallon Carpet Extractor Series

Prime Chiller Mini-Chillers

MaxLite LED High Bay Fixtures

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

CC Series VACUUM PUMPS

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation and Maintenance "L" and "LS" Series

Fly / Rear Deltoid. Owners Manual

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

120 VAC SYSTEM CONTROL KIT Model: CK-63

Instruction Manual for the Globe Mixer. Model SP8-RL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

55-Gallon Dispenser Package

Owner s Manual & Safety Instructions

Installation Instructions / Warranty

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

A2Z Ozone, Inc. PRODUCT MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Owner Instructions. Warning! Read instructions before using the machine. Model: SSS 1500C Back Pack Vacuum

(HSTAT Series) Instruction Manual

16 Stand Fan with Remote Control Model No: FS3-40R-30

Instruction Leaflet. Read instructions before operating. Retain for future reference.

STACK-AND-SHRED100X&100M SHREDDERS start here

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

PEDICUTE PORTABLE SPA

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

MIXERS SMX10-1, SMX20-1, SMX20-2, SMX30-1 INSTRUCTION MANUAL

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

ion Genesis Pump Controller

Service & Parts Manual

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

GL-DEH Series Portable Dehumidifier Operating Instructions

55-Gallon Dispenser Package

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Humidity Monitor model 01080

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

Installation Instructions / Warranty. Metris 31060XX XX XX1

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Panel Mounted Heat Exchangers by Dantherm, Inc.

Digital Refrigerator/Freezer Thermometer model 00986

Transcription:

Sound Cover [77001603, 77001604, 77001605, 77001606] Intended Use: To provide lower sound (dba) levels for Midmark PowerAir Compressors. Requirements / Restrictions: After cover is mounted to compressor, verify fans have 6 inches of clearance so air flow is not restricted. Components: End Panels... 2 Back Panel with Wire Harness... 1 Front Removable Panel... 1 Top Removable Panel... 1 Truss Head Screws #10-24 x 3/8.. 8 Kit 77001605 & 77001606 use Hex Head Bolts 3/8 x 5/8 LG... 4 Lock Washers 3/8... 4 Kit 77001603 & 77001604 use Hex Head Bolts 5/16 x 5/8 LG... 4 Lock Washers 5/16... 4 Equipment Alert PowerAir Compressors are equipped with a thermal switch which will shut down the compressor in the event of a high temperature condition due to a fan failure or blockage. The compressor will automatically restart when the temperature lowers inside the cover. To speed the cooling process, the top panel may be temporarily removed until service is preformed or the situation is corrected. Verify hoses and wires are routed so they are not touching compressor heads. Remove Access Panel Bolts and Washers Screws... 4 Washers... 8 Nuts... 1 Actuator... 1 Capacitor... 1 Cover... 2 Step 2: Disconnect power to compressor. Mount end panels to compressor. Note: Install bolts loosely, do not tighten. AA216700 Step 1: Equipment Alert - Earlier Versions Only Remove access panel to increase air flow, so unit does not overheat. Remove access panel. AA193700 Midmark Corporation 2007 1 10541800 Rev. D

Step 4: Tighten end panel bolts. Route and secure fan wires with clips along left end panel. Connect fan plug. Step 3: Assemble back panel to end panels. Clip Bolt Fan Plug Models P21, P22, P32 Clips are on Top. Models P52 & P72 Clips are on bottom. Clip #10-24 Truss Head Screws (8) AA193600 AA193900 Midmark Corporation 2007 SF-1905 2

Earlier Versions Equipment Alert Hoses resting against compressors head could melt if not positioned away from heads. P21, P22 & P32 Models Only... Step 5: Pull air hoses out through bottom of sound cover. Bend air hoses up and away from heads. Bend Hose to Allow Clearance Away From Head Current Versions Pull Hoses Out Through Bottom of Sound Cover AA218500 AA217000 P52 & P72 Continue with Step 6 Midmark Corporation 2007 3

P21 & P22 & P32 Continue with Step 7 Equipment Alert Hoses resting against compressors head could melt if not positioned away from heads. P52 & P72 Models Only... Step 6: Route hoses through hanging clips with cable ties and out through triangular hole in bottom corners of sound cover. Route Hoses To Clips Without Resting on Heads As Shown Top View-P52 Hanging Clip Top View-P72 Bring Hoses Out Through Opening In Corners On Earlier Version Models Current Version Hoses Are Attached to Manifold Located in the Center AA218600 Midmark Corporation 2007 SF-1905 4

Step 7: Install removable panels. Bottom Screws Are 1/2 Turn Only Step 8: Connect power to compressor. Note: Fans will not operate until temperature inside sound cover is approximately 95 degrees Fahrenheit. AA193800 Note Periodically, check to make sure fans spin freely and vacuum dust from fan openings. Midmark Corporation 2007 5

LIMITED WARRANTY SCOPE OF WARRANTY Midmark Corporation ( Midmark ) warrants to the original purchaser its Air and Vacuum accessories (except for components not warranted under Exclusions ) manufactured by Midmark to be free from defects in material and workmanship under normal use and service. Midmark s obligation under this warranty is limited to the repair or replacement, at Midmark s option, of the parts or the accessories the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of installation for the original user, shall be: Midmark Air and Vacuum Accessories: 90 Days EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following: (1) repairs and replacements because of misuse, abuse, negligence, alteration, accident, freight damage, or tampering; (2) products which are not installed, used, and properly cleaned as required in the Midmark Installation manual and/or Maintenance guide for this applicable product; (3) products considered to be of a consumable nature; (4) accessories or parts not manufactured by Midmark; (5) charges by anyone for adjustments, repairs, replacement parts, installation, or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark. EXCLUSIVE REMEDY Midmark s only obligation under this warranty is the repair or replacement of defective parts. Midmark shall not be liable for any direct, special, indirect, incidental, exemplary, or consequential damages or delay, including, but not limited to, damages for loss of profits or loss of use. NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products. THIS WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. Midmark Corporation For contact information, go to: www.midmark.com Midmark Corporation 72007 SF-1905 6