Wiring the fan correctly...

Similar documents
Wiring the fan correctly...

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Thank you for choosing EnviroVent

HOTLINE:

November This product has been reconfigured Please read these instructions

HOTLINE:

Thank you for choosing EnviroVent

ECo 2 Wall USER GUIDE FOR RESIDENT

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Thank you for choosing EnviroVent

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Watch the heatsava video

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Filterless Extract Fan. WC, Bathroom + Kitchen

Introducing the RetroVent

Cyclone 7 Designed to Perform. Built to Last. WC. Bathroom & Kitchen

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen

condensation mould high humidity

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

KUDOS. Instruction leaflet

CLASSIC-100. Instruction leaflet. Instruction leaflet

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

ECO dmev Decentralised MEV

UBBU60LFA. Built-under Fridge Manual for Installation, Use and Maintenance IM UBBU60LFA_

Dust Mites. You are sharing your bed with thousands of them! Virus. Mould / Fungi. Mites. Allergy / Asthma. Tracheal Infection. Chemical Reactions

GUH90 90 cm Canopy Hood

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

60cm Integrated Turbo Extractor

Lo-Carbon SELV Tempra

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

FWC153, FWC304, FWC604 & FWC624

GUH52SD 52 cm GUH75 75 cm Canopy Hood

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

The Range Condensation Control Systems. Positive Input Ventilation

EZT90BL Extractor. Installation, Use and Maintenance.

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra Centrifugal Fan

Purge Ventilation Unit. Product Manual. ventilation systems TP625

55CM Wide Freestanding Under Counter Freezer Instruction Manual

ECHK90 & ECPK90 Extractors Manual for Installation, Use and Maintenance

EVP61/91/101/121. Extractor. Installation, use and maintenance.

FWC860 Wine Cooler Installation, Use and Maintenance

Lo-Carbon Quadra SELV

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

100cm Chimney Hood GB IE

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

EDD61 & EDD91 Extractors

Chmney Hood - Model: H91PK H91PX H101PK H101PX. COOKER HOOD - User instructions

Warnings, Safety Information and Guidance

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Stainless Steel Chimney Extractor

EZA60BL & EZA90BL Extractors

Stainless Steel Chimney Extractor

60cm Chimney Extractor

INSTALLATION & USER INSTRUCTIONS

Cooker Hood. CHX60BK / CHX60SS / CHX90SS -Version 04. WARNING: Read the instructions before using the appliance.

60cm Canopy Extractor

What is PIV? Positive Input Ventilation

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Personal Blender User guide

Installation and Operating Instructions

Cooker Hood Instruction Manual

IMPORTANT: RETAIN FOR FUTURE REFERENCE

ART cm Island Curved Glass

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Manual for installation, use and maintenance MEH & MEP. Chimney Extractors. year. parts + 1 year labour guarantee.

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Simply Silent Contour 4 (100mm) Axial Extraction Fan

LUCCI WHITEHAVEN DC CEILING FAN

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

Cooker Hood Instruction Manual

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

IMPORTANT: RETAIN FOR FUTURE REFERENCE

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

QUALITY SPACE HEATERS

EH0533 Indoor Climate Control

Turbo Vac Pro 18V 2 in 1 Cordless Cleaner

BLOW DRY & GO HAIR KIT

Stainless Steel and Glass Angled Extractor

22.2V Turbo Lite Ultra Cordless Handheld Vacuum

CG60/ 70/ 80/ 90/ 100 SS/BK

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Transcription:

You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore ensure that this product is treated with care and installed properly i.e. for the life of the building. If the unit is mishandled you might break it! This invalidates the warranty. And remember, if you have any problems please call our dedicated Technical Team. We are always pleased to help and in an emergency will come out to site quickly, completely free of charge. Wiring the fan correctly... 1 The connection into the fan MUST be a flexible cable and NOT solid core twin and earth, if the fan is mishandled or a solid core twin and earth cable is forced into the terminals you WILL break it, this will invalidate the warranty. 2 If it is necessary to use twin and earth you must not take it into the fan. Use a terminal block to make the connection between the flexible cable supplied with the fan and your solid core twin and earth cable. 3 Place the cables inside the void in the back of the back carcass next to the cable gland and secure the fan to the wall securely. IMPORTANT: The black grommets and sticky pad provided must be fitted in this unit. Not using these items will jeopardise both the IP rating and the warranty. Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.

The Cyclone 7 is a major advancement in extract fan technology, designed to deliver high performance in controlling humidity levels in kitchens, bathrooms and utility rooms using the lowest energy consumption. The Cyclone 7 also incorporates patented BioCote antibacterial protection to inhibit the growth of bacteria, microbes and mould on the surface of the fan by up to 99.9%. HOW IT WORKS The Cyclone 7 works in a constant trickle mode to create background ventilation to maintain a healthy environment. Vapour tracking As standard the unit is fitted with vapour tracking. The fan senses the amount of moisture being created in the room which causes the fan to increase in speed to match the rising humidity and reduce in speed to match falling humidity. This intelligent function reduces your energy costs, wear and tear on the motor and ensures a long quiet life. Pullcord All units are fitted with a pullcord override for odour control (if remote see below). In the event that you wish to activate the fan to full power in conditions of low humidity simply pull on the pullcord and the fan will boost to maximum extraction rate. OPTIONS Remote control Remote control override for odour control. In the event that you wish to activate the fan to full power in conditions of low humidity simply press the remote control boost switch and the fan will boost to the maximum extraction rate for 3 to 4 minutes before returning to the trickle extract rate. N.B: When battery requires changing, unscrew the switch front cover. The battery is located on the back of the cover (CR2032) lithium coin battery). Switch will remain paired with the fan even after battery replacement. ENERGY USE The Cyclone 7 uses ultra Low Watt Motor Technology to achieve the lowest running costs of any domestic extract fan. It uses only a minimal amount of electricity whilst eliminating stale and moist air from the home. This gives an annual running cost of only 1.97 based on an electricity cost of 0.15 per unit (KWH), and a two hour boost per day. Household Appliance Cyclone 7 Fridge Freezer Time required to consume 1.97 of electricity 1 Year 6 and a half days 21 Television (viewing time) 5 and a half days 100W Light Bulb Home Computer Games Console Iron 5 and a half days 1 and a half days 1 and a half days 13 Hours Remote Switch Wire The unit is available with a remote switch wire. On these units the boost switch may be located up to 3 meters away from the unit. Tumble Dryer Coldfill Dishwasher 5 and a quarter hours 7 Full Loads

INSTALLATION INSTRUCTIONS IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current IEE Wiring Regulations 17th edition (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. DO NOT WIRE THROUGH A LIGHT SWITCH This is a constant trickle fan which requires permanent electrical supply. DO NOT REMOVE OR TAMPER WITH ELECTRONIC CIRCUIT BOARD This is not a user function. This appliance can be used by children aged from 8 and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. CYCLONE 7 COMPONENTS Central cartridge Front cover Back Carcass (Permanent fixture - DO NOT REMOVE ONCE INSTALLED) Impeller

INSTALLATION INSTRUCTIONS 1. Loosen the two plastic screws and remove front cover. (Fig 1.) Fig.1 2. Carefully withdraw central cartridge from the carcass. Disconnect green male/female connector. (Fig 2.) 3. Drill Ø107mm hole in chosen position ensuring clearance around fan. Insert ducting to suit (not supplied). 4. Use back carcass as a template, mark fixing holes, drill, plug and screw back carcass with screws provided (4x 8x 1.5 ). Fit the 3 blanking plugs into holes in top chamber. (Fig 3.) 5. Please note that a suitable isolation switch or fuse spur rated at 3amp should be used in the fixed wiring. Fig.2 SELV Version (if installing 230V please see page 5) 6. This fan must be installed by a competent person. Complete electrical wiring of fan. Tighten cable gland. Low voltage requires connection via power supply provided. Ensure red to red and check mains connection in fused spur (3amp fuse only). 7. Offer up the central cartridge join green male/ female connector (12V DC) and carefully insert central cartridge into back carcass. Insert four silver screws to fix central cartridge in place. N.B. Take care not to trap cables. (Fig 4.) Cable gland NO CABLES Avoid cable entry into shaded areas Fig.4 Alternative fixings (blansk to be used) 100mm ducting (Ø106) 125mm ducting (Ø131) Wall fixings Fig.3

INSTALLATION INSTRUCTIONS 230V Version 6. This fan must be installed by a competent person. Offer up the central cartridge join green male/female connector (230V) and carefully insert central cartridge into back carcass. Insert four silver screws to fix central cartridge in place. N.B. Take care not to trap cables. (Fig 4.) 7. This fan is factory set to kitchen duty with humidity tracking function. If two speed or bathroom option is required, commission fan by setting slider switch as appropriate (Fig.5a/5b). Fix supplied gasket over selector switches. Fig.5a Fig.5b SELV SLIDER 1. LEFT - Humidity Tracking RIGHT - Two Speed 2. SLIDER NOT USED 230V SLIDER 8. Check impeller is fitted correctly - ensure click action engaged cleanly. (Fig. 6) 9. F i x f ro n t c o v e r. E n s u re p u l l c o rd n e s t l e s i n t o g ro o v e. N.B. Fan will not operate unless front cover is in position. (Fig. 7) place. 1. LEFT - Humidity Tracking RIGHT - Two Speed 2. LEFT - Kitchen RIGHT - Bathroom Fig.6 Fig.7 OTHER APPLICATIONS/VARIATIONS For recessed only installations we can supply a bezel. COMMISSIONING: This fan is factory set to kitchen duty with humidity tracking function.

MAINTENANCE All repair, maintenance and component replacement is carried out simply and quickly by exchanging the plug out/plug in central cartridge. The worn out cartridge can then be returned to the EnviroVent factory to be recycled/reworked. This when necessary cartridge exchange with re-worked components will ensure that the basic fan installation will remain intact throughout the repair cycle of the dwelling, eliminating the wasteful disposal of plastic and other non biodegradable material to landfill sites. CLEANING Your Cyclone 7 has been designed for easy safe cleaning. ISOLATE THE UNIT FROM ELECTRICAL MAINS SUPPLY BEFORE REMOVING ANY COVER, OR SERVICING THE UNIT. 1. Loosen the two plastic screws underneath the fan.(fig.1) 2. Pull the front cover towards you from the bottom. It will pull towards you with a slight hinge action from the top. (Fig.2) Fig.1 Fig.2

MAINTENANCE 3. Push the impeller clips together with forefinger and thumb and pull impeller towards you. (Fig.3) 4. Wash the cover and impeller in warm, soapy water. Dry and replace, as above in reverse. (Fig.4) N.B. Use a damp, soapy cloth to clean scroll (NO SOLVENTS) Fig.3 Fig.4 IQ CONTROL (OPTIONAL) Remote Control Boost Switch The Cyclone 7 operates continuously at a low rate known as trickle, to ensure that your kitchen or bathroom is ventilated at the appropriate level. The Cyclone 7 will automatically vary its extract rate when it senses an increase in the moisture level running through the fan. By pressing the button once on the remote control boost switch, the green LED will illuminate and the unit will go into boost mode. The boost time is set to 3.5 minutes.

TECHNICAL SPECIFICATIONS Duty (l/s) Power (W) Sound db(a) @ 3M 15 2 30.8 35 7 36 60 25 46.2 Airflow (l/s) TROUBLESHOOTING Check feed/power supply. Have you checked connections? - (Green male/female connector; SELV red wire to plus symbol / blue wire to minus symbol). Have you removed printed circuit board for any reason? Cartridge correctly seated (no stray wires trapped)? Does impeller spin freely? - Check click Is the front cover in place? Does pull cord activate freely?

GUARANTEE The EnviroVent Cyclone 7 is covered by a full 7 year warranty which will benefit the occupier over many years. The unit will be set according to the size of the property and will operate continuously. There is no requirement for any maintenance within the 7 year period. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your Cyclone 7 is not working correctly, you can telephone (operational from 8:00am to 5:00pm Monday to Friday), and ask for technical assistance. You will either be given guidance over the telephone, or an arrangement will be made for an engineer to visit. In any event, please have the following information ready. This will enable your call to be dealt with quickly and efficiently. Serial number of the unit: We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. However, it is important that you register your purchase. This will ensure the prompt and efficient handling of any communication in the event that your unit requires attention during the 7 year warranty period. Your warranty covers any defect or break down that arises due to faulty materials or construction. WARRANTY CONDITIONS AND EXCLUSIONS The system must be correctly installed and operated according to the instructions contained in the user guide supplied. The warranty will be rendered invalid if the system has been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by EnviroVent Ltd. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The guarantee will only be honoured from approved suppliers (i.e. not ebay or similar), and proof of purchase must be provided.

Please read carefully to ensure simple installation and a long trouble free life for the user. AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER - DO NOT THROW AWAY EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA T 0345 27 27 807 F 01423 301 022 E enquiries@envirovent.com www.envirovent.com E&OE MKT ENV284-V4-24.02.16 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.