KANE-ALERT-CO 2 Monitor with Temperature

Similar documents
Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

LS1. Operator Manual. Kane International Ltd

CD100A COMBUSTIBLE GAS DETECTOR

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

CO2 Monitor Operating Instructions

Oxygen Monitor Operating Manual

User's Guide. CO 2 Monitor. Model CO200

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

CDL 210. Operating manual. CO2 Logger. Best.-Nr

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

HIn3550 Magnetic Field Monitor User's Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Safe Operation Manual. Honeywell IQ Force Gas Detector

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

HOBO U14 Data Logger User Manual


ALTAIR 5X Multigas Detector Product Specification

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

ANALOX 3000 Carbon Monoxide Monitor

VALTRONICS IAQ Monitor

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

RS Pro Infrared Temperature Sensor

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

USER MANUAL Digital CO Monitor Model CO30

INSTRUCTION MANUAL for WS 9420 Digital COMFORT INDEX Thermometer-Hygrometer with Mold Alert and Dew Point Temperature P. 1

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Sirius Technologies, Inc.

EasyLog Data Logger Series

Specifications Minimum Typical Maximum Unit

INSTRUCTION MANUAL MODEL GX-82A

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

EasyLog Data Logger Series

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

Oxygen & Carbon Dioxide Analyser. Model 1737 Operators Manual

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Reference Manual. MultiVision Gas Detector

EL-USB-1-LCD Temperature Data Logger with LCD

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Issue 4 10/10/11. Part Number: 48160

APC BC300 Series 40kW 208/450/480V User Guide

WBGT Heat Stress Meter

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Operating Instructions and Maintenance Manual

aspida User Manual T: +44 (0) F: +44 (0) W: E:

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

POWER METER INSTRUCTION MANUAL

USER GUIDE Heat Index Psychrometer

INSTRUCTION MANUAL MODEL GX-82A

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

Operating Instructions

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

MK10 CO Safety System Connected to Central Unit

IMR IX176 Portable Gas Detector User Manual

SC-01 Operator s Manual

Oxygen & Carbon Dioxide Analyser. Model 1737 Operators Manual

Using the QRAE Plus personal multigas monitor

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

English US User s Manual

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Warranty Registration

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Microprocessor Digital Thermometer

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

WIRELESS COLOR FORECAST STATION

Professional Wireless Rain Guage with 4" LCD

User s Manual. MkVII CO 2 Safety System

Model 60200FR Gas Primary Control Data Sheet

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Pocket CO2 Monitor & Data Logger SAN-0001

Water Tank Level Monitor

Aspida. User Manual. Commercial in Confidence

EL-OEM-3 OEM Packaged Voltage Data Logger

For the Safety of Your

Datasheet: K-22 LO Sensor

Transcription:

KANE-ALERT-CO 2 Monitor with Temperature Operating Instructions Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277 Email: sales@kane.co.uk www.kane.co.uk Stock No: 18606-3 February 2008

This is a portable, handheld carbon dioxide (CO 2 ) monitor using NDIR technology to provide long term stability. It also measures ambient temperature. The monitor also has the following features: Data logger stores 48 sets of CO 2 and temperature readings in the last 24 hours - one log every 30 minutes. Max/Min mode records the maximum and minimum concentrations of CO 2 since the monitor was switched on. Alarm mode sounds at 1000 PPM (the ASHRAE limit) and can be turned off. RCFS Mode recovers original factory settings after the monitor is recalibrated. (Display Features and Modes) 1. Power Button 8. Function Label 2. Enter Button 9. Gas Entry Hole 3. Down Button 10. Power Inlet 4. Up Button 11. RJ45 Socket 5. Mode Button 12. Housing Stand 6. LCD Display 13. Battery Cover 7. LED Light 14. AA Batteries *4

MODE FUNCTIONS The monitor has several Modes which can be adjusted. In sequence these modes are Alti Mode, Alarm Mode, Outside Mode, Cali Mode, Datalogger Mode, MaxMin Mode and rcfs Mode. ALTI Compensates for changes in atmospheric pressure due to altitude or weather conditions. ALARM OUTSIDE Alarms when CO 2 concentration exceeds 1000 ppm. Alarm sounder can be switched on or off. Modifies the outside CO 2 concentration. The factory nominal setting is 400 ppm. CALI DATALOGGER MaxMin rcfs Allows trained service personnel to recalibrate the sensor. Take care using this function as errors can be created. Shows CO 2 and temperature records over the last 24 hours. Reading No. 1 is the most recent. Reading No. 48 is the oldest. Shows Max and Min CO 2 readings since last being switched on. These readings are cleared every time the device is switched off. Recovers the factory setting.

OPERATION INSTRUCTIONS Power On Press Power button (1) to turn on the monitor after placing 4 AA batteries into the battery compartment (take care to observe correct polarity) or AC adapter plug into the DC socket. CO 2 readings will show after 15 seconds of warm up. WarmUp This lasts approximately 1 min before WARMUP disappears; none of the functions will respond during warm up. Normal Operation After warm up, the monitor stabilizes and displays CO 2 readings on its Upper Display which remain visible at all times. Temp and Ventilation Rates (Lower Display) Use the Up/Down button to scroll through Temperature and Ventilation Modes. When pressing the Up button, the lower display goes through the following sequence: Temp C-> Temp F-> Vent Rates lps-> Vent Rate cfm/p *Note: lps refers to Litres Per Second Per Person; cfm/p refers to Cubic Feet Per Minute Per Person This function assumes that each person exhales 300 cc of CO 2 every minute and calculates the rate of ventilation of external air required to achieve equilibrium at the measured CO 2 level.

Adjusting Modes 1. ALTI Mode Setting the altitude at which you are using the monitor 1.1. Press Mode until ALTI flashes 1.2. Press Mode to alter between m (meters) and ft (feet) 1.3. Press Up/Down to adjust the altitude (Step=100m/500ft) 1.4 Press Enter to save the setting or leave the ALTI Mode, return to UserMode. 2. ALARM Mode Switching On or Off the Audible Alarm 2.1. Press Mode until ALARM flashes 2.2. Press Enter until ALARM speaker icon flashes Press Up/Down to turn the ALARM On or Off 2.3. Press Enter to save the setting and return to UserMode. 3. OUTSIDE Mode Setting the outside level of CO 2 if known **Note: Ventilation Rate Ventilation rate represents how much air is introduced into the indoor space from the outside. Low levels indicate low ventilation rates and potentially poor air quality. High levels indicate excessive ventilation and potential excessive energy usage. To obtain an accurate measurement, readings should be taken 2~3 hours after occupancy has stabilized in a space or at a peak in daily CO 2 concentrations. In indoor air quality control, CO 2 value is an indicator of ventilation rate. 400ppm (Parts Per Million) is the default CO 2 concentration outside (according to ASHRAE: American Society of Heating, Refrigeration and Air-conditioning Engineers). 3.1. Press Mode until OUTSIDE flashes 3.2. Press Enter until OUTSIDE, CO 2 and PPM flash Press Up/Down to adjust the reading 3.3. Press Enter to save the setting and return to UserMode After modification, the VENT Rate will change.

4. CALI Mode Recalibrating the CO 2 sensor 4.1. The monitor is pre-calibrated in the factory and should only be recalibrated with a certified test gas in a controlled test chamber. This mode should only be accessed by trained service personnel. 5. DATA LOGGER Mode Viewing data recorded over the previous 24 hours The monitor s internal Datalogger records CO 2 and temperature readings every 30 minutes over the past 24 hours. 5.1. Press Mode until DATALOGGER flashes 5.2. Press Enter until CO 2 and Temperature are displayed Press Up/Down to PAGE UP/DOWN readings 5.3. Press Enter to return to UserMode 6. MaxMin Mode Viewing Maximum and Minimum values The monitor s MaxMin Mode displays the maximum and minimum CO 2 readings since the monitor was last switched on. 6.1. Press Mode until MAX MIN flashes 6.2. Press Enter to alternate between MAX and MIN CO 2 readings 6.3. To clear the memory, press UP or DOWN until CLR flashes. Press Enter to CLEAR the MAX and MIN record 6.4. Press Mode or Enter to return to UserMode 7. rcfsmode If the CO 2 sensor is incorrectly re-calibrated, the monitor s factory setting can be recovered. 7.1. Press Mode until rcfs flashes on the lower display 7.2. Press Enter until no shows on the upper display 7.3. Press Up/Down to change to yes Press Enter, Factory Setting will reload 7.4. Press Mode to return to UserMode

SPECIFICATIONS Display LCD Independent CO 2 and Temperature readings Calculates and Displays Ventilation Rates Sample Method Diffusion CO 2 Specification Measurement Range Display Resolution Accuracy Repeatability Temperature Dependence Pressure Dependence Response Time 0-3,000 ppm display 1ppm from 0~1,000ppm; 5ppm, from 1,000~2,000ppm; 10ppm from 2,000~3,000ppm over 3000 ppm display shows "Hi" ±50 ppm, or ±5% of reading ±20 ppm ±0.1% of reading per C or ±2 ppm per C, whichever is greater, referenced to 25 C 0.13% of reading per mm Hg (Corrected via user input for altitude) <2 min for 63% of step change Warm-Up Time <60 seconds at 22 C Calibration Interval 12 months.

Temperature Specification Temperature Range 0 to 50 C / 32 o F to 122 F Display Resolution Display Options Accuracy Response Time Calibration Interval 0.1 o C / 0.1 F C / F, or off. Set with Up/Down button ±1 o C / ±2 F 20-30 minutes (case must equilibrate with environment) 12 months Power Supply Battery type: Alkaline, 4 x AA cells give approx. 80 hours operation. External: 6 VDC from external AC/DC adapter supplied as standard. Note: charger is designed for indoor use only. Power Requirement 160 ma Peak, 15 ma average from 6V General Operating Conditions Operating Temperature: 0-50 C / 32-122 F 0-95% RH Non-condensing Storage Temperature: -20 to 60 C / -4 to 140 F LCD ERROR MESSAGES The monitor has 3 visual diagnostic messages as follows:

The monitor is measuring temperature outside its measurement range. These are displayed when it is necessary to reset the monitor. To reset, switch off the monitor, remove its batteries and wait for a minimum of one minute, reinsert batteries and switch on. If either error message remains please contact our Service Department for further assistance. Warranty: 12 months parts and labour.

ELECTROMAGNETIC COMPATIBILITY European Council Directive 89/336/EEC requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation. Specific standards applicable to this analyser are stated below. As there are electrical products in use pre-dating this Directive, they may emit excess electromagnetic radiation levels and, occasionally, it may be appropriate to check the analyser before use by: Use the normal start up sequence in the location where the analyser will be used. Switch on all localized electrical equipment capable of causing interference. Check all readings are as expected. A level of disturbance is acceptable. If not acceptable, adjust the analyser s position to minimize interference or switch off, if possible, the offending equipment during your test. At the time of writing this manual (Nov 2007) Kane International Ltd are not aware of any field based situation where such interference has occurred and this advice is only given to satisfy the requirements of the Directive. This product has been tested for compliance with the following generic standards: EN 61000-6-3 EN 61000-6-1 and is certified to be compliant Specification EC/EMC/KI/ALERT-CO2 details the specific test configuration, performance and conditions of use. Please Note: Batteries used in this instrument should be disposed of in accordance with current legislation and local guidelines. At the end of the product's life it should be re-cycled in accordance with current legislation and local guidelines.

ANNUAL RECALIBRATION AND SERVICE There are no user serviceable components in this product. Although sensor life is typically more than five years the analyser should be recalibrated and serviced annually to correct for any long-term sensor or electronics drift or accidental damage. Local regulations may require more frequent re-calibration. APPENDIX Recommended Carbon Dioxide Levels: British Standards BS6896, BS6230 and BS5990 confirm CO 2 concentration should not exceed 2800ppm where people are working. HSE Regulation EH40 sets the maximum occupational exposure limit at 5000ppm. BSRIA recommend a maximum of 800ppm over an eight hour time weighted average. ASHRAE (62/99) recommends a maximum level of 1000ppm. Data on ambient CO 2 : NOAA observatory (US. National Oceanic and Atmospheric Administration) http://www.cmdl.noaa.gov/ccgg/insitu.html http://www.cmdl.noaa.gov/ccgg/iadv/

Thank you for buying this instrument. Before use, please register on our website www.kane.co.uk to start its 1 year warranty.