INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

Similar documents
E S F I P D G R A DB A(3) E HNIKA RUSSIAN

Function Controller MCM-A100

Wireless Remote Controller

FH052EAMT FH070EAMT E S F I P D G R DB A(2) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH RUSSIAN E HNIKA

OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG

E S F I P D G DB A(1) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG π Ã

UH175GCM UH175GZM. Ventiltype Klimaanlage (Kühlen und Wärmen) KÏÈÌ ÙÈÛÙÈÎfi T appleô AÂÚ ÁˆÁÔ (æ ÍË Î È ÚÌ ÓÛË )

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

E XEIPI IO E KATA TA H

Type ACH1800E ACH2400E CH18ZA CH24ZA CH18CA CH24CA

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO MANUEL D INSTALLATION INSTALLATIONS-HANDBUCH

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

Safety Precautions WARNING INSTALLING THE UNIT POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL. System Air Conditioner (Cooling and Heating) Cassette Type Series CH070CAV1 CH105CAV CH140CAV DB A(1) ENGLISH ESPAÑOL

Air Conditioner. installation manual. imagine the possibilities. Wired Remote Control MWR-WE10. Thank you for purchasing this Samsung product.

Split-type Room Air Conditioner (Cool) Aire acondicionado doméstico sistema Split (Refrigeración) Climatiseur de type Séparé (Refroidissement)

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

Outdoor unit MH18AP1(P2)X MH19AP1(P2)X MH24AP1(P2)X MH26AP1(P2)X

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Wired Controller XK60

SIMPLE WIRED REMOTE CONTROLLER

SU MO TU WE TH FR SA AM PM

AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

Model name: AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH AJ007JNADCH AJ009JNADCH AJ012JNADCH

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

AIR CONDITIONER OUTDOOR UNIT INDOOR UNIT. 1. Precautions

AIR CONDITIONER TECHNICAL MANUAL CONTENTS SYSTEM TYPE. Duct. Cassette 123 MODEL IDENTIFICATION 127 SPECIFICATION 121 INSTALLATION

OnOff Controller MCM-A200DN_IB_EN_03736A(1).indd 오후 2:45:04

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATION MANUAL. Wireless Remote Controller Kit

3. INDOOR UNIT OPERATION

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

MA Remote Controller PAR-31MAA

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

AJ036JCJ5** Air Conditioner. installation manual. imagine the possibilities. Thank you for purchasing this Samsung product. EN ES FR DB A-01

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

Air Conditioner. installation manual. imagine the possibilities

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

53 KNL / 53 QNL OWNER S MANUAL

New Wide Wired Remote Controller

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

Colour Observation System

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

CAUTION. Installation Manual

USER S MANUAL AIR-CONDITIONER MANUEL DE L UTILISATEUR ANWENDERHANDBUCH ISTRUZIONI PER L USO MANUAL DEL PROPIETARIO GEBRUIKERSHANDLEIDING

Operating Instructions Air Conditioner

Operating Instructions

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

USER S MANUAL AIR-CONDITIONER MANUEL DE L UTILISATEUR ANWENDERHANDBUCH ISTRUZIONI PER L USO MANUAL DEL PROPIETARIO GEBRUIKERSHANDLEIDING

AIR CONDITIONER (SPLIT TYPE)

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

HX-80NRAM. High Mount Outdoor Detector

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

Part 3 Troubleshooting

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

AIR CONDITIONER. Model : 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

SEMTIC HEATING

DESIGN & TECHNICAL MANUAL

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Operation Manual - PC-ARF - P IMPORTANT:

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E. Model name: Slim Duct Type.

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

Installer manual AG-WL10

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

INSTALLATION MANUAL For authorized service personnel only.

SYSTEM AIR CONDITIONER

Owner s Manual. Indoor Unit MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL AIR CONDITIONER (MULTI TYPE)

OPERATING MANUAL UTY-RNNYM P/N English

Fast Track Troubleshooting

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

Wireless Remote Controller Kit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Operating Instructions

INSTALLATION MANUAL. AIR CONDITIONER INDOOR UNIT Compact Wall Mounted Type INSTALLATION MANUAL. INSTALLATIONSANLEITUNG Nur für autorisiertes Personal.

Ductless Split Air Conditioner

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Air Conditioner installation manual

AIR CONDITIONER. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5. PCB Diagram. 6.

Portable Air Conditioner Instruction Manual

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

Transcription:

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH E XEIPI IO E KATA TA H àçëíêìäñàü èé ìëíäçéçäö Wired Remote Controller MWR-TH ENGLISH ESPAÑOL FRANÇAIS System Air Conditioner Aire acondicionado sistemático Climatiseur numérique multifonctionnel Sistema Aria Condizionata Sistema Ar Condicionado Klimaanlage System ÛÙËÌ ÏÈÌ ÙÈÛÌÔ ëëòúâïì È ÇÓÁ Û Ì È äóì ˈËÓÌÂapple RUSSIAN ITALIANO PORTUGUÊS E HNIKA DEUTSCH E S F I P D G R A DB98-577A()

Safety Precautions This installation manual indicates you to install the wired remote controller which is connected to the indoor unit. For installation of other optional accessories, see an appropriate installation manual. WARNING Read carefully this installation manual before installation and check whether the remote controller is installed correctly after installation. Do not attempt to install or repair this wired remote controller by yourself. This remote controller contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the remote controller. Ensure that the wall is strong enough to support the weight of the remote controller. Must install the remote controller with rated power supply. The remote controller must be installed according to the national electrical rules by an installation specialist. When you want to disuse the remote controller, consult authorized installation center. CAUTION Do not use inflammable gases near the remote controller. Do not install the remote controller in a location where it will come into contact with the combustible gases, machine oil, sulphide gas, etc. Avoid a location where acid/alkali solution or special spray is used. Choose a location that is dry and sunny, but not exposed to direct sunlight. Available temperature is between C and 39 C. Do not spill water into the wired remote controller. Do not give tensile strength to the cable to avoid disconnection. Do not press buttons with a pointed thing. Do not connect the power cable to the control terminal. If the remote controller is installed in a hospital or other special places, it should not affect other electronic devices. E-

Contents ENGLISH WIRED REMOTE CONTROLLER AND ACCESSORIES....... 4 DIVIDING THE COM/COM Flowchart for dividing COM/COM...................... 5 The Diagram of COM/COM........................... 6 INSTALLING TO COM(F, F) INSTALLING THE COMMUNICATION CABLE Installing the Communication cable...................... 7 Installation........................................... 8 Setting up indoor unit PCB and Wired Remote Controller Option Switches............................. 9 Examples of installing Wired Remote Controller............ The errors indicated on the Wired Remote Controller........ INSTALLING TO COM(F3, F4) INSTALLING THE COMMUNICATION CABLE Installing the Communication cable......................3 Installation...........................................4 Setting up indoor unit PCB and Wired Remote Controller Option Switches.............................5 The errors indicated on the Wired Remote Controller........6 Examples of installing Wired Remote Controller............7 The errors indicated on the GHP Wired Remote Controller... ADDITIONAL FUNCTION OF THE WIRED REMOTE CONTROLLER Assigning the indoor unit RMC with the Wired Remote Controller...............................8 Canceling the indoor unit RMC assigned with the Wired Remote Controller...............................3 E-3

Wired Remote Controller and Accessories Accessories The following accessories are supplied with the air conditioner. The number of each accessory is indicated in parentheses. Cable-tie () Cable clamp (5) M4x6 tapped screw (7) Indoor Unit Power Drawing Communication cable of the wired Wire joint () User s manual () Adjust K Cable DIP () remote controller () switch(sw3) on the PCB to the OFF position. CAUTION The wired remote controller must be installed by an installation specialist. Before installing the wired remote controller, check that you have turned off the main power. All cables should be installed according to the national wiring rules and you must install it to the wall not to be touched by users. Communication cable and power cable should be installed separately. (Connecting the power cable to communication terminal will cause serious damage to the wired remote controller. Please make sure that the power cable is connected to the appropriate power terminal to avoid serious damage.) E-4

Dividing the COM/COM ENGLISH Flowchart for dividing COM/COM Does the indoor unit support COM(F3, F4)? (Refer to the indoor unit user's manual.) No Yes Install the wired remote controller to COM. (Assign the DS switch of the PCB of the wired remote controller to SW OFF.) Install the wired remote controller to COM. (Assign the DS switch of the PCB of the wired remote controller to SW ON.) PCB of the indoor unit Wired remote controller PCB K : Adjust to OFF position. S/W NO Switch ON Switch OFF COM COM SW (F, F) (F3, F4) E-5

Dividing the COM/COM (cont.) The Diagram of COM/COM COM Diagram DVM Outdoor unit COM(F, F) Indoor unit MAIN RMC MAIN RMC MAIN RMC Wired remote controller COM Diagram Group control DVM PLUS Outdoor unit COM(F, F) Indoor unit COM(F3, F4) COM(F3, F4) Wired remote controller Group control E-6

Installing to COM(F, F) ENGLISH Installing the Communication cable In case of -way cassette, connect the terminal BLOCK of the opening part of the indoor unit with the main PCB of indoor unit using the indoor unit power drawing cable as shown in the picture. The wired remote controller power cable is installed in all air conditioners except -way cassette. AC Power supply Don t confuse the color. Indoor unit PCB Red Communication cable of the wired remote controller COM(F, F) Red RedP(.5 pitch) RedP (.5 pitch) Blue White Power cable of the wired remote controller Blue White Black Black WhiteP(.5 pitch) WhiteP (.5 pitch) E-7

Installing to COM(F, F) (cont.) Installation 3 Open the wired remote controller by using grooves on its top. Secure the rear cover of the wired remote controller on the wall with screws. Connect each F, F, V, V, indoor unit terminal with the wired remote controller terminal F, F, V, V. When connecting the communication cable and the power cable, don t confuse about each cable. If the cables are connected improperly, the wired remote controller will not work. 4 After checking the kind of outdoor unit, assign the DS switch SW of the indoor unit PCB to ON. If you set to COM and install it to COM, 66 of error signs is displayed on the wired remote controller. SW SW SW3 SW4 SW5 SW6 SW7 SW8 Switch No. Switch OFF Switch ON SW Cooling Only Cooling and Heating SW COM(F3, F4) COM(F, F) DS DS SW3 SW4 SW5 C The wired and wireless remote controller available F Can be used wired remote controller only Refer to the chapter Additional Function of the wired remote controller. 5 Reassemble the wired remote controller. E-8

ENGLISH Setting up indoor unit PCB and Wired Remote Controller Option switches Indoor unit PCB If you control the indoor unit with the wired remote controller, adjust K of SW4 option switch of the indoor unit PCB to OFF. If you install the indoor unit as shown in the picture, can control it with the wired remote controller. ADDRESS of the wired remote controller and RMC ADDRESS of the indoor unit should be assigned as the same. Therefore as the RMC ADDRESS is adjusted to in the picture, the indoor unit is controlled by the wired remote controller which is adjusted to. RMC SW4 Indoor unit MAIN PCB switch Wired remote controller PCB Assign the RMC ADDRESS of the wired remote controller same as the indoor unit to be controlled. DS3 ADDRESS Switch E-9

Installing to COM(F, F) (cont.) Examples of installing Wired Remote Controller Individual control : Individual control of 3 indoor units with 3 wired remote controller. Indoor unit PCB DVM Outdoor unit SW4 MAIN ADDRESS RCM ADDRESS Indoor unit MAIN RMC MAIN RMC MAIN RMC Wired remote controller E-

ENGLISH Individual & Group control : Controlling indoor unit of 3 indoor units with ADDRESS of the wired remote controller individually and controlling the other indoor units with ADDRESS of the wired remote controller as a group. Indoor unit PCB DVM Outdoor unit SW4 MAIN ADDRESS RCM ADDRESS Indoor unit MAIN RMC MAIN RMC MAIN RMC Wired remote controller Group control E-

Installing to COM(F, F) (cont.) The errors indicated on the Wired Remote Controller The errors of outdoor unit, indoor unit and optional accessories are indicated on the LCD. If the is indicated, press the button in front of the wired remote controller to display the error code. In case of displaying same error of several indoor units, the front number is displayed first. Display Explanation Remark ER ER ER ER ER ER EA EB A B C D Indoor unit Wired LCD communication error Wired LCD Indoor unit communication error EVE IN sensor separation error of the indoor unit EVE OUT sensor separation error of the indoor unit Open error of electronic expansion valve in the outdoor unit Close error of electronic expansion valve in the outdoor unit ER F EVE MID, EVE OUT sensor simultaneous separation error of the indoor unit ER ER ER ER ER ER ER ER ER ER G G G3 O Q R Y T U V SUB COOL sensor separation error of the outdoor unit Refrigerant leak of outdoor unit / Loading Failure COND MID sensor separation error of the outdoor unit Floating S/W error of the indoor unit Room sensor OPEN/SHORT error of the indoor unit EVE IN sensor OPEN/SHORT error of the indoor unit EVE OUT sensor OPEN/SHORT error of the indoor unit EEPROM inferior error EEPROM option error Fan motor moving is abnormal Indoor unit ADDRESS : E-

Installing to COM(F3, F4) ENGLISH Installing the Communication cable If the indoor unit is a -way cassette, connect the indoor unit PCB to the terminal block within the indoor unit using the power cable of the wired remote controller as shown in the first picture. All other indoor units except the -way cassette have the power cable installed. Connector type cable connection AC Power supply Indoor unit PCB White Don t confuse the color. White White P(.5 pitch) White P (.5 pitch) F3 Black Red Power cable of the wired remote controller Black Red F4 Blue Communication cable of the wired remote controller COM(F3, F4) Blue Blue P(.5 pitch) Blue P (.5 pitch) Terminal type cable connection AC Power supply Indoor unit PCB White Don t confuse the color. White White P(.5 pitch) White P (.5 pitch) Black Red Power cable of the wired remote controller Black Red Blue Communication cable of the wired remote controller COM(F3, F4) Blue Blue P(.5 pitch) Blue P (.5 pitch) E-3

Installing to COM(F3, F4) (cont.) Installation Open the wired remote controller using the grooves on the top. Secure the rear cover of the wired remote controller on the wall with screws. 3 Connect V, V with the wired remote controller terminal V, V. 4 After checking the kind of outdoor unit, assign the DS switch SW of the indoor unit PCB to OFF. If you set to COM and install it to COM, EA communication error sign is displayed on the wired remote controller. F3 F4 Housing Tighten the cable with the wire joint (accessories) tightly. Indoor unit 5 6 Connect the indoor unit housing with the wired remote controller housing or connect the F3, F4 terminal of the wired remote controller to the F3, F4 terminal of the terminal block depending on the indoor unit type. Reassemble the wired remote controller. Cables (purchased on the spot) Cables (purchased on the spot) Wired remote controller Indoor unit Wired remote controller CAUTION Install the wired remote controller of GHP in the same way. The wired remote controller must be installed by an installation specialist. Before installing the wired remote controller, check that you have turned off the main power. All cables should be installed according to the national wiring rules and you must install it to the wall not to be touched by users. Communication cable and power cable should be installed separately. (The wired remote controller can be operated abnormally due to electric trouble.) E-4

ENGLISH Setting up indoor unit PCB and Wired Remote Controller Option Switches Indoor unit PCB Adjust the K switch(sw4) - option switch of the indoor unit PCB - to OFF, which is to be controlled by the wired remote controller. Adjusting of the K switch(sw4) means the use of wired remote controller. DS DS DS3 The back of the wired remote controller Wired remote controller PCB Connect the wired remote controller with the indoor unit to be controlled. (You don t have to assign the ADDRESS.) Refer to the following option table to assign the switch according to the user s situation. Switch No. SW Switch OFF Cooling Only Switch ON Cooling and Heating DS3 SW COM(F3, F4) COM(F, F) SW3 C F SW4 Wired and wireless remote controller available Can be used wired remote controller only ADDRESS Switch SW5 Refer to the chapter Additional Function of the wired remote controller. E-5

Installing to COM(F3, F4) (cont.) The errors indicated on the Wired Remote Controller The error of outdoor unit, indoor unit and optional accessories is indicated on the LCD. If the is indicated, press the button in front of the wired remote controller to display the error code. In case of displaying same error of several indoor units, the front number is displayed first. Note -remote controller controls the indoor unit individually connected with the COM regardless of setting the indoor unit RMC ADDRESS. Display Explanation Wired remote controller Indoor unit communication error Master wired remote controller Slave wired remote controller COM/COM cross-installed error Remark When using -remote control E-6

ENGLISH Examples of installing Wired Remote Controller Individual control : Individual control of indoor unit wired remote controller Wired remote controller PCB Indoor unit PCB Outdoor unit COM COM Indoor unit COM COM COM Wired remote controller DS3 Don t change the default settings of the wired remote controller. Note Don t change the DS3 switch of wired remote controller PCB from the default settings when the outdoor unit is shipped from the factory. (If you change the default settings, the communication error is displayed and the wired remote control doesn t operate normally.) The wired remote controller controls the indoor unit individually connected with the COM regardless of the set RMC ADDRESS of the indoor unit. E-7

Installing to COM(F3, F4) (cont.) Group control : Controlling more than indoor units with a wired remote controller Wired remote controller PCB Indoor unit PCB Outdoor unit COM COM COM Indoor unit COM COM Wired remote controller E-8

ENGLISH Group control : The outdoor unit controls different indoor units simultaneously with a wired remote controller. (Except the GHP model) Wired remote controller PCB Indoor unit PCB Outdoor unit Indoor unit Outdoor unit Wired remote controller Indoor unit Note The wired remote controller controls the indoor units together connected with the COM regardless of setting the indoor unit RMC ADDRESS. E-9

Installing to COM(F3, F4) (cont.) -remote controller control : -remote controller means wired remote controllers control indoor unit. Set the DS3 switch of the wired remote controller PCB as shown in the picture. Wired remote controller PCB Indoor unit PCB Outdoor unit COM COM Indoor unit Wired remote controller(master) Wired remote controller(slave) DS3 DS3 (Set to ) (Set to ) E-

ENGLISH The errors indicated on the GHP Wired Remote Controller The error of outdoor unit, indoor unit and optional accessories is indicated on the LCD. If the is indicated, press the button in front of the wired remote controller to display the error code. In case of displaying same error of several indoor units, the front number is displayed first. Display Remote Outdoor unit PCB controller code Sub code # # Explanation Communication error between the wired remote controller and indoor unit The same ADDRESS errors Trouble After communication between the wired remote controller and indoor unit more than once and communication cuts off for minutes continuously The same ADDRESS of the indoor unit Examination frquency (times) Indoor and outdoor unit connection error No outdoor unit which is correspond to the indoor unit Indoor and outdoor unit communication error Communication error between the indoor unit and centralized controller - Communication error after communication between wired remote controller and indoor unit more than once - Error is displayed from the indoor unit during operation - Communication error after communication between wired remote controller and indoor unit more than once - Error detected from the outdoor unit (6 seconds during operation, 5 seconds during off) The self - transmission data is not received After communication between wired remote controller and centralized controller more than once and cut off for minutes continuously # is indicated according to the unit ADDRESS (~F). E-

Installing to COM(F3, F4) (cont.) Display Remote Outdoor unit PCB controller code Sub code # Explanation Indoor unit fan motor error Trouble The fan doesn t operate in set speed or is stopped Examination frquency (times) # Indoor unit EEPROM error - Record of the data is forbidden during power failure - Discord between a record data and call data # Manual ADDRESS of the indoor unit is mixed up Communication discord with the indoor unit Manual ADDRESS of the outdoor unit is mixed up Communication discord with the outdoor unit EEPROM error Indoor unit connection exceeds Discord between indoor and outdoor unit EEPROM error More than 6 indoor unit is connected with the outdoor unit Discord between indoor and outdoor unit Abnormal ventilation temperature Ventilation temperature is over 66 C during engine operation for more than 3 seconds Communication error between indoor and outdoor unit Induction temperature sensor of the compressor is disconnected After communication between indoor and outdoor unit more than one time and the communication among indoor units is cut off for minutes continuously Induction temperature sensor of the compressor : detects lower than -39 C for minute continuously Induction temperature sensor of the compressor : detects lower than -39 C for minute continuously 3 Induction temperature sensor of the compressor (SHORT) Induction temperature sensor of the compressor : detects higher than 9 C for minute continuously Induction temperature sensor of the compressor : detects higher than 9 C for minute continuously # is indicated according to the unit ADDRESS (~F). E-

ENGLISH Display Remote Outdoor unit PCB controller code Sub code 3 4 5 Explanation Starter error Outdoor air temperature sensor is disconnected Outdoor air temperature sensor (SHORT) Outdoor air temperature sensor is abnormal Accumulator outlet temperature sensor is disconnected Accumulator outlet temperature sensor is disconnected Accumulator outlet temperature sensor (SHORT) Accumulator outlet temperature sensor (SHORT) Accumulator outlet temperature sensor is safe Accumulator outlet temperature sensor is safe Outdoor heat exchanger temperature sensor is disconnected Outdoor heat exchanger temperature sensor (SHORT) Engine water temperature sensor is disconnected # is indicated according to the unit ADDRESS (~F). Trouble Detects higher than 5V for 3 seconds of the starter voltage during off Detects the outdoor temperature lower than -39 C for minute continuously Detects the outdoor temperature higher than 9 C for minute continuously Detects outdoor air temperature sensor disconnection or short circuit for minutes continuously Accumulator outlet temperature sensor is disconnected Accumulator outlet temperature sensor is disconnected Accumulator outlet temperature sensor (SHORT) Accumulator outlet temperature sensor (SHORT) Accumulator outlet temperature sensor is safe Accumulator outlet temperature sensor is safe Detects outdoor heat exchanger temperature sensor lower than -39 C for minutes continuously Detects outdoor heat exchanger temperature sensor higher than 9 C for minutes continuously Detects engine water temperature sensor during engine operation lower than C for 3 minutes continuously Examination frquency (times) (5 minutes) (5 minutes) E-3

Installing to COM(F3, F4) (cont.) Display Remote Outdoor unit PCB controller code Sub code Explanation Engine oil pressure switch is disconnected Trouble - Before turning the starter ON, detects engine oil pressure switch OFF for 5 seconds continuously - After detecting first times, operate engine for 3 seconds and stops for 6 seconds - Stops operating after detecting 3 times Examination frquency (times) 6 8 4 Engine room temperature sensor is disconnected Engine room temperature sensor (SHORT) Ventilation temperature sensor is disconnected Engine room temperature sensor error High pressure sensor error Shortage of the number of engine rotations Engine rotations control error # is indicated according to the unit ADDRESS (~F). Detects engine room temperature lower than -3 C for minutes continuously Detects engine room temperature higher than 9 C for minutes continuously Detects ventilation temperature lower than 5 C for 4 minutes continuously when operating more than compressor during engine operation Detects disconnection or short circuit of room temperature sensor for minutes continuously - Stops when the high pressure more than.9mpa refrigerant is abnormal if the compressor turns on - Detects high pressure more than 3.Mpa when operating of next term - Stops for 5 seconds when the high pressure lower than.mpa when the compressor turns on - Detects high pressure lower than.mpa when operating of next term After turning the starter on, rotation pulse is less than 4 5 seconds after connecting with the compressor, one of the following error is detected - Detects the engine rotation is lower than RPM for 6 seconds continuously - Detects the engine rotation is lower than 8RPM for seconds continuously (5 minutes) 3 (5 minutes) E-4

ENGLISH Display Remote Outdoor unit PCB controller code Sub code 6 7 3 4 5 Explanation Engine rotations control error Engine rotations hunting error Electronic gas valve error Engine stop Low voltage of lighter Detection circuit of voltage is disconnected High voltage of lighter High pressure switch is disconnected - Discharge temperature of the compressor is not risen - Discharge temperature of the compressor (SHORT) # is indicated according to the unit ADDRESS (~F). Trouble - The engine rotation frequency detects that ordered rotation frequency that is lower than ±3RPM for 6 seconds continuously 5 seconds after connecting with the compressor, one of the following error is detected - Detects the engine rotation is lower than RPM for 6 seconds continuously - Detects the engine rotation is lower than 8RPM for seconds continuously - The engine rotation frequency detects that ordered rotation frequency that is lower than ±3RPM for 6 seconds continuously Continuous output of gas valve or for 3 seconds continuously except for the timer of gas valve operation Detects the engine rotation frequency is lower than 65RPM for second continuously Detects the voltage of lighter lower than 9V for minute continuously Detects the voltage of lighter lower than.5v for minute continuously Detects the voltage of lighter higher than 7V for 3 seconds continuously Detects OFF of the high pressure switch for 3 minutes continuously if you stop operating or during initial operation (Detects only when the transmitter is ON) Detects the outlet temperature lower than 5 C when the compressor is on for minutes continuously Detects the outlet temperature lower than 5 C when the compressor is on for minutes continuously Detects the outlet temperature 3 lower than 5 C when the compressor 3 is on for minutes continuously Detects the outlet temperature 4 lower than 5 C when the compressor 4 is on for minutes continuously Examination frquency (times) 3 (5 minutes) 3 (5 minutes) 4 (5 minutes) 3 (5 minutes) (5 minutes) (5 minutes) (5 minutes) (5 minutes) E-5

Installing to COM(F3, F4) (cont.) Display Remote Outdoor unit PCB controller code Sub code 3 4 Explanation Engine water temperature is overheated Engine water temperature sensor SHORT Shortage of cooling water of the engine Engine oil pressure error Engine rotates too often Engine operation failure Engine MICOM communication error Engine program record error High pressure of refrigerant error Induction temperature of the compressor is overrisen # is indicated according to the unit ADDRESS (~F). Trouble Detects the engine water temperature for operating higher than 5 C for seconds continuously (reset lower than 9 C available) Detects the engine water temperature higher than C for minutes continuously (reset lower than C available) Detects that the cooling water of the engine is overheated higher than 9 C for and a half minutes after stop Detects the engine oil pressure switch ON for 3 seconds continuously after it passes seconds after operating engine Detects the engine operation higher than 3,5RPM for longer than second continuously Detects the engine operation higher than,6rpm for longer than second continuously The number of engine rotations less than 7RPM is not detected.8 seconds after turning the starter, for gas valve is OFF Engine MICOM communication error Engine program record error Examination frquency (times) (5 minutes) - Detects the high pressure switch OFF for 3 seconds continuously when the compressor is ON 3 (5 minutes) - Detects the high pressure higher than.9mpa for 5 seconds continuously when the compressor is ON Detects when the compressor is turned ON, the higher temperature from the temperature range that the inlet sensor sensed in the connection parts of the compressor over 6 C for minutes continuously (5 minutes) 3 (5 minutes) 3 (5 minutes) 4 4 4 E-6

ENGLISH Display Remote Outdoor unit PCB controller code Sub code Explanation Trouble Examination frquency (times) Low pressure of refrigerant error Detects the low pressure switch OFF for 3 seconds continuously when the compressor is ON (5 minutes) Low pressure switch is disconnected Detects low pressure switch OFF for 3 minutes continuously when stops for operating or when oil temperature is secured 5 3 6 7 7 Shortage of refrigerant Discharge temperature of the compressor is overrisen Discharge temperature of the compressor (SHORT) The air conditioner cools and heats simultaneously Detects high pressure switch(higher than.5mpa) or low pressure switch OFF (reset available when high pressure switch is higher than.5mpa or low pressure switch is ON) Detects temperature sensor of the connection side of the compressor(select the highest when more than compressor) higher than C for 3 minutes continuously (reset available when all of the 4 detected temperature is lower than C) Detects the compressor temperature higher than C for minute continuously (reset available when the temperature is lower than C) Detects the compressor temperature higher than C for minute continuously (reset available when the temperature is lower than C) Detects the compressor temperature 3 higher than C for minute continuously (reset available when the temperature is lower than C) Detects the compressor temperature 4 higher than C for minute continuously (reset available when the temperature is lower than C) The air conditioner cools and heats simultaneously (5 minutes) # is indicated according to the unit ADDRESS (~F). E-7

Additional Function of the Wired Remote Controller When using automatic ADDRESS of DVM PLUS, assign MAIN ADDRESS to the indoor and outdoor unit. The RMC is not assigned to the indoor unit. If you want to control the air conditioner with the centralized controller, you should operate the RMC switch of the indoor unit manually. You can also assign the RMC using wired remote controller without operating manually. (Only in COM available) Assigning the indoor unit RMC with the Wired Remote Controller You can use this function to control the indoor unit in the centralized controller. It means that you assign the RMC with the wired remote controller without operating the RMC switch manually. S/W NO. SW5 Switch OFF Switch ON Assign the the indoor Cancel the indoor unit unit RMC with the RMC assigned with the wired remote controller wired remote controller E-8

ENGLISH Set SW5 of DS switch on the wired remote controller PCB to OFF. Wired remote controller PCB SW SW SW3 SW4 SW5 SW6 SW7 SW8 DS DS Set the indoor unit PCB Press the button and button in front of the wired remote control simultaneously for more than 5 seconds. 3 Wired remote controller LCD displays as shown in the picture and changes to the Indoor unit group ADDRESS setting mode. Wired remote controller LCD Group ADDRESS (RMC) display Indoor unit Main ADDRESS display E-9

Additional Function of the Wired Remote Controller (cont.) Initial display is displayed if the group has never been set. If the group is set, the LCD receives the current indoor unit ADDRESS(main address) and group ADDRESS (RMC) from the indoor unit and displays them. Changing of group ADDRESS (RMC) Press the button to select the required group ADDRESS. Then, the group ADDRESS display flickers and changes. Setting the group ADDRESS Quit Press the button once to set the selected group ADDRESS with the beep sound. Press the button again to quit the setting mode and enter the operation mode. If you press the button in the mode except the Canceling the group ADDRESS, quit the Setting the RMC switch group ADDRESS mode. CAUTION When assigning the RMC, the wired remote controller of each indoor unit should be installed one to one. If you assign the RMC to the indoor unit with the wired remote controller, the indoor unit is controlled by the RMC(assigned with the wired remote controller) in the centralized controller even if the RMC is set to the indoor unit PCB manually. E-3

ENGLISH Canceling the indoor unit RMC assigned with the Wired Remote Controller Set SW5 of DS switch on the wired remote controller PCB to ON. Wired remote controller PCB SW SW SW3 SW4 SW5 SW6 SW7 SW8 DS DS Press the button and button in front of the wired remote controller simultaneously for more than 5 seconds. 3 Wired remote controller LCD displays as shown in the picture and changes to the Indoor unit group ADDRESS setting mode. Wired remote controller LCD Group ADDRESS (RMC) display Indoor unit Main ADDRESS display E-3

Additional Function of the Wired Remote Controller (cont.) Initial display If the group has never been set, the LCD receives the RMC ADDRESS which is set to the indoor unit and displays them. Setting the RMC switch Press the button once to control the indoor unit with the set RMC switch ADDRESS with the beep sound. Quit Press the button again to quit the setting mode and enter the operation mode. If you set the PCB RMC switch to 3 Wired remote controller LCD Example of the display If you press the button in the mode except the Setting the RMC switch, quit the Canceling the group ADDRESS mode. E-3

Memo ENGLISH E-33

THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H Y KEYH KATA KEYA THKE A O: ùíéí äéçñàñàéçöê àáééíéçãöç îàêåéâ: ELECTRONICS Printed in Korea