Risk Management of Fire using Video Based Detection

Similar documents
Video Imaging Detection Systems

Protecting our future! Advanced fire protection for pupils, teaching staff and physical assets

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Essentials of Fire Fighting 6 th Edition Firefighter I

Economic Impact of Building Regulations

FIRE PREVENTION The Gory Story

FIRE EMERGENCY POLICY

Urban Fires & Wildfires November 3, 2009

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

The Social Accountability International (SAI) Fire Safety Checklist

ECONOMIC JUSTIFICATION FOR SPRINKLER SYSTEMS

INSTRUCTORS MANUAL SAMPLE ONLY

Security & Monitoring Services

Fire statistics 9/12/

Fire Cause Determination

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

Analysis of Availability of Fire Fighting Equipment in Selected Knitting Garment Factories in Bangladesh

Innovative Industrial Solutions, Inc Skyline Drive Russellville, AR 72802

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

Risk Management Services

Impact of quick incident detection on safety in terms of ventilation response

Data Centers. ASD 535 Application Report

For Complete Security

( )

Fires How you can help prevent fires in homes or apartment buildings, with just a few easy methods.

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

Video Verified Alarms Best Practices

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Guideline No 11:2005. European guideline. Recommended Numbers of Fire Protection Trained Staff

FIRE SAFETY FOR OFFICE WORKERS

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Fire Safety and Utility Controls. CERT Basic Training Unit 2

Vacant Building Loss Prevention Best Practices

REED COLLEGE DEPARTMENT OF COMMUNITY SAFETY DEPARTMENTAL DIRECTIVE CSO FIRE & FIRE ALARM SYSTEM RESPONSE GUIDELINES

Patrick D. Gallagher, Under Secretary of Commerce for Standards and Technology and Director

Y. ORMIERES. Fire risk analysis method for nuclear installations

Frequently Asked Questions

Emergency Action Plan Leading the Fight

Specialists in Tunnel Fire Protection

New Approaches to Design for Fire Safety

2014 Annual Fire Safety Report

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

CFPA-E No 1:2014 F. Fire protection management system CFPA-E -GUIDELINES

Fire Safety Plan (FSP) Review Checklist 1

Austin Independent School District Police Department Policy and Procedure Manual

Fire Safety and Utility Controls. CERT Basic Training Unit 2

ADPRO. Integrated Security and Surveillance Solutions. Intelligent - Flexible - Reliable

EASTERN ARIZONA COLLEGE Fire Department Operations II

Audio Verified Alarms Best Practices

Why Building Occupants Ignore Fire Alarms

SPRINKLER MYTHS. MYTH: In a fire all the sprinkler heads go off together. FACT: Only the sprinkler head(s) directly affected by the fire is triggered.

FIRE PROTECTION AND EMERGENCY SERVICES BYLAW

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

How SCDF Does it MAJ ANDY CHOO FIRE INVESTIGATION UNIT OPERATIONS DEPARTMENT HQ SCDF

INTRUSION SOLUTIONS. Yehans Surveillance & Security Systems. laser perimeter alarming CONTACT US ON

Chapter 2 Background. 2.1 VID Technology

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

VISEUM UK PRESENTATION

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

False Alarm Management

Hazardous Material Safety Program

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

Effective Deployment of the Integrated Wireless Network Video Systems for the Homeland Security & Government Sectors

CCTV Surveillance: Business Security & Video Best Practices.

Protecting Facilities Against Explosions. Since 1956

Protezione antincendio di dati e business critical assets nei Data Centers

HOME FIRES THAT BEGAN WITH UPHOLSTERED FURNITURE

FIRE SAFETY AND PREVENTION POLICY

XFlow water mist system preserves and enhances productivity at a TULIP Sausage factory in Svenstrup Denmark.

Protecting Critical Facilities Against Explosions

City of Bartlesville. City of Bartlesville. Multi-Hazard. Hazard Mitigation Planning. Mitigation Plan Update

research highlight Canadian Housing Fire Statistics Findings

4.13 Security and System Safety

Considerations for Development of Effective Flammability Standards

Draft Document. A 15 Year Update on the Impact and Effectiveness of the Scottsdale Sprinkler Ordinance

Tech Note - 25 Surveillance Systems that Work! Motion Security on GSS PC-Based DVR

FIRE PROTECTION ISSUES IN THE HOT CELLS OF A NUCLEAR FACILITY

Fire System Impairment Policy

Whitestown Fire Department Standard Operating Procedure

Underground fires in metro systems failures, accidents and terrorism

Austin Independent School District Police Department Policy and Procedure Manual

Onsite Fire Risk Reduction Methods

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage

Heating Fires in Residential Buildings

Standard Operating Procedure Ottawa Fire Services. Fire Operations- Structural Fire Incidents SUBJECT. Fire Alarm Systems (Silence/Reset) - Revised

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

*366 unique incidents were reported; based on reasonable assumptions, we can extrapolate that facility fires have occurred in the past 12 mo.

Fire Safety Plan (FSP) Review Checklist 1

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

PUBLIC FIRE SAFETY EDUCATION PREVENTION. Presented By: Fire Chief Donald Donaldson June 29, 2005

Tunnels, Risks & Design Mitigation

Emergency Evacuations What you need to know

ARTECO White Paper Stop Copper Theft. How Video Analytics are Helping Electrical Utilities Proactively

How design fires can be used in fire hazard analysis

Structure Fires in Hotels and Motels

Fire Investigation

Transcription:

Risk Management of Fire using Video Based Detection Measuring the Threat The annual risk of a fire can be estimated using fire statistics and a thorough evaluation of the impact that an actual fire would have on property values, building content and business disruption. Studies and statistics throughout the United States, Canada, and Europe indicate the probability of a fire to be approximately 1.8% per 100,000 ft 2 of commercial facility. Therefore if you had a 200,000 ft 2 facility the probability of a fire that would require a first responder response would be 3.6%; the probability of a fire for a 50,000 ft 2 facility would be.9% and so on. Obviously industrial facilities such as utilities, chemical plants, oil and gas processing, machinery intense, etc will have a higher risk based on the nature of that business. A good summary that explains the difference in probability and loss associated with a fire is an excerpt form the Fire Safety Policies of the Minister of Public Security, Quebec 2001. An analysis of the fires that have occurred in Quebec over the past decade confirms the existence of a relatively close relationship among the parameters that are used (along with the risk classes determined by those parameters) and the two basic dimensions of fire risks: probability and consequences. Statistics for the common bungalow will serve to illustrate this relationship. Even though the bungalow is the scene of 68% of fires in Quebec because of its widespread presence, the probability that a fire will break out in such a building is still relatively low, indeed, much lower than the probability that a fire will start in an industrial building for example. Between 1992 and 1999, the fire rate for the residential sector was 3.08 per 1,000 buildings (similar to the U.S.) compared to a fire rate of 15.78 per 1,000 in the commercial sector and 41.68 per 1,000 in the industrial sector (See Table 1). In other words, the fire risks for commercial and industrial buildings are respectively, five and thirteen times greater than the fire risks for homes. The residential sector is far and away the sector for which fire statistics show the greatest loss of lives. Reducing the number of deaths due to fire in that sector depends not primarily on the work of firefighters but rather on prevention measures or early fire detection. The evidence for the relation between building use and the effects of fire is no less convincing with regard to property loss. Between 1992 and 1999, the average amount of property loss due to fire in commercial buildings and industrial/manufacturing buildings was $79,268 and $132,138 respectively. In other words, the losses caused by fire in the commercial and industrial sectors are, respectively, three and five times higher than the losses caused by the fire in the residential sector. These figures are presented in absolute values, that is, per $1,000 of building value.

Table 1 USE Fires Property Loss (Sector) Average Fire Rate Relative Fire Total Losses Rate / $1000 Average Loss Relative Annual No. /1000 buildings Rate (in thousands)*value** (in $) Loss rate Residential 6,560 3.08 1.00 172,019 1.08 26,224 1.00 Services 480 11.66 3.79 31,329 0.88 65,269 2.49 Commercial 709 15.78 5.12 56,201 3.49 79,268 3.02 Industrial 553 41.68 13.53 73,006 5.49 132,138 5.04 * in constant 1999 dollars ** Rate adjusted according to the tax-assessed value of buildings, excluding their contents Evaluating a specific situation It can obviously be observed that industrial facilities have higher incident rates and loss than say a commercial building, which makes sense based on larger size, energy intensive manufacturing, more flammable materials, potentially heated processes, etc. Once the probability of a fire event is determined then the loss associated with that fire should be estimated. There are many factors that contribute to the damage a fire can cause once it has ignited. Are there automatic detection devices present? Recent statistics have shown that 72% (U.S.) and 68% (U.K.) of non residential structure fires were in facilities with no automatic detection in the ignition area. A large number of these types of industrial, storage, and large volume areas just do not have an adequate performing detection solution at this time. Point type spot detectors (heat and smoke) are just impractical for these large open areas. Video fire and smoke detection is an ideal solution for these types of applications. Video Fire and Smoke detection is analogous to having a guard stationed permanently in each area. Whenever a camera sees a fire or smoke event it will issue a visual alarm. How fast will the fire spread? The spread of the fire will be affected by the fuel and air available. Is it a large open area? Are there flammable materials in the area that will advance the spread of the fire? The damage associated with a fire increases exponentially with time based on the spread of that fire. Identifying a fire as soon as it generated will allow suppression to contain and extinguish the fire. Once detected, how will the fire be suppressed? After the fire is detected be it automatically or by someone walking down the street, the emergency response is critical. Is there a guard on site that can immediately respond and put out the fire with an extinguisher versus a remote monitoring center that only has been contacted by a telephonic alarm and would still have to dispatch an emergency responder? Is there a local fire department within minutes of the facility or is the site remotely located with a longer response time?

Will the fire event be catastrophic? Depending on what starts a fire, where it is located, and what fuels are available and how fast it spreads, a fire could be a relative non-event or it could be catastrophic - destroying a facility and causing major asset damage and huge business interruption losses. What would a catastrophic event cost the business - is it possible? Calculating Fire Risk If we take the Quebec study as an example the average industrial property loss was $132,138, if we follow the basic rule of thumb that building content and business interruption loss is at least 3 X the property loss than the average total loss for an industrial facility would be $528,552. We ll assume the probability of a fire in this facility is 4% based on the Quebec study and the assumption the industrial building is a midsized manufacturing facility. Thus the annual cost of fire would be: Fire Risk ($) = Probability X Single Loss Occurrence Fire Risk ($) = 4% (.04) X $528,552 Fire Risk ($) = $21,142 To determine a Return on Investment (ROI) for installing a video based fire and smoke detection system, a determination must be made about how much Fire Risk will be mitigated based on installing a video based detection system. Because fire spread and damage increase exponentially with time, the cost of the fire damage will follow the same pattern. If there is currently no detection present in a facility there would be a drastic reduction in annual fire risk expense. Detecting an event in seconds with instant visual situational awareness and suppressing the fire immediately (a facility based guard with a fire extinguisher for example) would reduce expected fire expense an estimated 80% to 95%. If there are currently spot type detectors that risk may be reduced 60% to 80%. Attached is a fire-damage versus time curve that incorporates a SigniFire and a spot type detector system. The SigniFire system will not only detect much earlier 3-5 minutes in smaller volume spaces (as verified in Naval Research Lab testing), but will also give instant visual verification versus someone walking out to a remote part of the industrial facility to verify (which we estimate to be 4 minutes). If we assume the emergency responder reaction time to be 4 minutes for each case then the SigniFire system would save approximately 80% of the fire damage versus a spot type detector system. If we continue with our example and assume this industrial facility has no current automatic fire detection (typical) then the annual reduction in fire risk would be at least an estimated 80%. This would reduce the annual fire risk expense from $21,142 to $4,228 or a savings of $16,914. To cover this type of facility it may take 16 cameras or two SigniFire FSM-8000 DVR processing units. If the installed cost of the system would be $40,000 then the ROI based on a simple payback method would be 40,000/16,914 or

2.4 years. This ROI would be incremental to any ROI based on the security function of the CCTV system which is obviously something most facilities are implementing today. Fire Damage vs. Time $600,000 $500,000 Spot Type Detector Cost (USD) $400,000 $300,000 $200,000 80% Cost (USD) Ignition SigniFire Detection Spot-type Detection Signifire Alarm Verification Spot-type Alarm Verification SigniFire FD Response Spot-type FD Response $100,000 $0 0 200 400 600 800 1000 1200 Time (seconds) Conclusion Video based fire & smoke detection is a safety and security technology that can provide an attractive return on investment. Large volume structures that contain high value assets should consider a performance based analysis including a video fire & smoke detection system that can provide early warning and instant situational awareness thereby drastically reducing the annual expense of fire. An analysis of the probability in conjunction with single loss occurrence should be conducted to understand the potential fire risk and the ability to mitigate that risk using advanced video based fire & smoke detection.

Sources: U.S. Fire Administration, Non-Residential Structure Fires in 2000, Topical Fire Research Series, Volume 3 Issue 10 June 2004 Prevention and Control of Arson in Industrial and Commercial Premises, September 2000, Arson Prevention Bureau United Kingdom ESDEP Lecture Note, Lecture 4B.1: Introduction of Fire Safety http://www.kuleuven.ac.be/bwk.materials/teaching/master/wg04b/10100.htm Fire Safety Policies of the Minister of Public Security, Quebec 2001. Utilization of statistics to assess fire risks in buildings, Kati Tillander, VTT Building and Transort Dissertation for the degree of Doctor of Science in Technology