Technical Specification of High and Low Temperature Altitude Test Chamber

Similar documents
Compact Ultra Low Temperature Chamber

Compact design for personal use Ready to network with your computer.

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Faster Temperature (& Humidity) Chamber

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Bench-Top Type Temperature (& Humidity) Chamber

Environmental Chambers

Customized Industrial Products

FAX:

Temperature Control Systems

Thermal Shock Chamber TSE 11

Air & Water Heat Pump R832

Mechanical Heat Pump R515

Faster Temperature (& Humidity) Chamber

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

DOUBLE DOOR FREEZER.

CAREL heatersteam Electric Element Steam Humidifiers

PROGRAMMABLE TEMPERATURE AND HUMIDITY CHAMBER

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

DAIKIN Huizhou Factory Profile

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Environmental Stress Chamber AR series

Refrigerated Incubators / Environmental Testing Chambers

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

UV Weather Resistance Test Chamber Technical Data

REFRIGERATOR M E D I C A L.

CLIMATE STSAR series. High and low temperature test chamber

Heated and Refrigerated Incubators

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Environmental Chambers

AS950 REFRIGERATED SAMPLERS

A660 Air Conditioning Laboratory Unit

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Multi-Lab REFRIGERATORS Frigidere medicale

PART 3 Refrigeration & Air Condition System

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

AZTECA A LITRE STERILISER

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 9. Packing list 9

Constant climate chambers

Automatic Isokinetic Sampler ST5

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Condensing Units w/ Screw Compressors

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

An ISO 9001 : 2008 Certified Company

PR / MP I Laboratory / Medicine

Constant climate chambers

MD-S7000. All Electric Injection Molding Machine NIIGATA MACHINE TECHNO CO.,LTD.

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Industrial Equipment 産業機器产业机器

Bench Top Temperature and Humidity Chamber

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

LZT High efficiency air to water heat pumps with E.V.I. compressors

Water-cooled Centrifugal Chiller

Benchtop Test Chambers Temperature and Humidity

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

YOUR PARTNER IN FIRE & GAS DETECTION

Operation Manual. Winding Turns Tester MODEL: TH-201/TH-201R. Changzhou Tonghui Electronic Co., Ltd.

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

.2 Section Waste Management and Disposal.

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Protection, safety, reliability. And more.

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

STABILITY ICH. ICH Stability Tests

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

CLIMATRON GROWTH CABINETS

INDUSTRIAL AIR CURTAIN. IndAC 2

Intelligent addressable fire alarm control panel

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

DP 300 mobile dew point instrument

RAYCHEM NGC-30 COMPONENTS

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Addressable Fire Alarm Control System 2100 series

Chilled Water Precision Air Conditioner for Critical Application

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

FITOCLIMA 600 & 1200 STABILITY

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Transcription:

Technical Specification of High and Low Temperature Altitude Test Chamber Model: KU-504L Manufacturer: KOMEG Technology Ind Co.,Ltd 1 / 8

Ⅰ. Control methods and characteristics No:16081010 Edition:00 High precision microcomputer control temperature and humidity system, with PID control the refrigerant flow to make the system s heating and humidification reduction, to achieve low power consumption, energy saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use. Ⅱ. Performance Water cooled, water temperature at 25, no load 2.1 Temperature range -40 ~+150 2.2Temperature fluctuation 2.3 Temperature deviation 0.5 (normal pressure, without load) ±2.0 (normal pressure, without load) 2.5 Heating time 20 +150,within 70 min (normal pressure, without load) 2.6 Cooling time 20-40,within 60 min (normal pressure, without load) 2.7 Pressure range From normal to 1kPa ±2 kpa( 40 kpa) 2.8 Pressure deviation ±5%(2~40 kpa) ±0.1 kpa( 2 kpa) 2.9 Pressure changing rate normal pressure to 1kPa,within 30min (no load, dry inside) GB / T2423.1-2008 Low temperature test method Ab GB / T2423.2-2008 High temperature test method Bb 2.10 Meet the test standards GB / T2423.21-2008 Low pressure test method M GB / T2423.25-2008 Low temperature / low air pressure comprehensive test Z/AM GB / T2423.26-2008 High temperature / low pressure comprehensive test Z/BM 2 / 8

GJB150.2A-2009 Low atmospheric pressure (height) test (Test procedureⅠ/Ⅱ) GJB150.3A-2009 High temperature test GJB150.4A-2009 Low temperature test GJB150.6A-2009 Temperature and altitude test Ⅲ. Structure 3.1 Test space dimension W H D:800 900 700mm 3.2 External dimension W H D: 1610 1990 2250 mm PS: not including external dimensions protruding part 3.3 External material External material use high-quality carbon steel with static color spray 3.4 Internal material Stainless steel plate (SUS # 304) 3.5 Insulation material 3.8 Door 3.9 Cable port and binding post 3.10 Manual charging valve High-density rigid Polyurethane foam + glass wool, (high strength, non-flammable, no deformation) Single open door, Explosion - proof handle, observation window 210*270mm, with lighting lamp inside. One Φ100mm cable hole on the left; with glass sintered sealing binding post (24 core - 10A) flange Manual inflation valve for manual pressure relief during power failure. 3.11 Shelf Stainless steel shelf *2 layer, load-bearing 30 kg/ layer. 3.11 Air heater in the box Fin type heat pipe stainless steel electric heater. 3.12 Heating control mode SSR (solid state relay) non-contact pulse width modulation. 3.13 Vacuum pump VD301 ULVAC vacuum pump 3 / 8

3.14 Vacuum sensor Model: UNIK 5072 (USA GE) Measuring range: 0 ~ 200KPa Comprehensive accuracy: ± 0.2% FS. BSL Output: 4 ~ 20mA Pressure interface: G1 / 4 internal thread Ⅳ. Refrigeration System 4.1 Working Mode Water - cooled mechanical compression cascade refrigeration 4.2Refrigeration compressor Mechanical compression refrigeration 4.3 Evaporator Finned copper coil heat exchanger 4.4 Condenser Water-cooled, shell and tube type condenser 4.8 Refrigerant R404a/R23 Non-fluorine environmentally friendly refrigerant 4.9 Other accessories Desiccant, oil separator, refrigerant flow window, repair valve Ⅴ. Control System 6.1 Controller 7 - inch TFT Programmable LCD Touch Screen Controller 6.2 Operation mode Program mode, constant value mode. 6.3 Operating language Chinese and Russian optional, touchscreen input 6.4 Program Capacity 6.5 Display Function Maximum 20, maximum 1000 steps, maximum 20 cycles (the maximum number of steps per cycle 99). Temperature / humidity / presure settings (SV) Practical (PV) value can be displayed directly, Execution of the program can display numbers, paragraphs, remaining time and cycles, running time display, Program editing and graphic curve display, Fixed or program operation status display, 6.6 Display Resolution Temperature: + 0.01ºC; Humidity: + 0.1%; time: 1min. 6.7 The upper and lower temperature protection The lower limit alarm temperature can be set. 4 / 8

function No:16081010 Edition:00 6.8 Input Thermocouple / Platinum Resistance / Voltage / Current. 6.9 Control mode 6.10 Curve recording function 6.11 USB function 6.12 Communication interface 6.13 Power Off Memory Function 6.14 Calendar timer function 6.15 Accessory (Standard configuration) 6.16 Network Connection Anti-integral saturation PID, BTHC (temperature and humidity test equipment), BTPC (temperature and pressure equipment). With battery protection of the RAM, you can save the device settings value, time of sampling value and sampling time; Maximum recording time of 60 days (when the sampling period is 1.5min). With a USB (capacity of not less than 1G, no warranty) one, PC-specific software CD-ROM. Through the PC software for the preparation of test procedures and save to USB, and then transferred from the USB test program and stored in the controller; can also be transferred to the controller program to USB, and then stored in the PC for analysis and management. Can be stored in the controller records the test curve data dump to the USB. Display and print the test data / curve directly with PC-specific software (the data can not be modified); or convert the recorded data to an Access data file that can be read by Microsoft Office Data collection and curve display when connected to a computer Can be used as monitoring and remote control system Multiple machines synchronization control available R232, RS485,and Ethernet Power recovery mode can be set as hot start, cold start and stop Automatic start and automatically stop running. Fault alarm code prompt function, power protection, self-diagnostic function. Can be connected to Ethernet via professional software, remote control & assistance function and data collection can be achieved through network, multiple machine can be controlled simultaneously 5 / 8

6.17 Control Panel 1. Emergency stop switch 2. Power switch 3. Over-temperature protection *1 4. RS-485 interface *1 5. USB interface Ⅵ. Safety protection device 7.1 Refrigerating system 7.2 Test chamber 7.3 Other security protection a. Compressor overheat protection switch b. Compressor over-current protection switch c. Compressor high voltage protection switch a. Adjustable over-temperature protection b. Test space temperature fuse c. Air conditioning channel limit over-temperature protection d. Fan motor overheating protection e. Heater over-current quick break tester a. Total power phase sequence and phase failure protection b. Leakage protection, overload and short circuit protection c. Vacuum pump motor over-current, overload protection Ⅶ. Installation Environment 8.1 Power Supply 8.2 Use compressed air source 8.3 Operating temperature range Ⅷ. Warranty AC 3ψ4W 380V 50HZ(R.S.T.N + ground wire) (voltage fluctuation ± 10%) Please provide 4 ~ 7kg / cm 2 compressed air source Ensure operating environmental temperature : 5 35 one year (Excluding natural disasters, power anomalies, human mal-operation, damage caused by improper maintenance, etc.) the Company completely free maintenance Main Material List SN Name Brand Remarks 1 Compressor BOCK Semi-hermetic compressor 6 / 8

2 Oil separator American Emerson, ALCO, Temprite 3 Plate exchanger heat GEA 4 press switch Denmark DANFOSS 5 Condenser Kuenling 6 Evaporator Yongqiang 7 Dry filter Denmark DANFOS 8 Expansion valve Denmark DANFOS 9 Expansion valve American HONEYWELL 10 Magnetic valve Japan Nickideu 11 Magnetic valve Denmark DANFOS 12 Controller KOMEG 13 Residual current circuit breaker Taiwan SHIHLIN 14 No-fuse switch French Schneider 15 AC contactor Japan French Schneider 16 Thermorelay French Schneider 17 Phase sequence relay Carlo Gavazzi 7 / 8

18 Solid-state relay Carlo Gavazzi 19 Intermediate Relay Omron 20 Cycle motor Taiwan Teco 21 Vacuum pump VD301 ULVAC 22 Vacuum valve Highlight AVB-KF-40-P 23 Vacuum sensor GE UNIK 5072 8 / 8