Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Similar documents
EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

PRODUCT CONFORMITY CERTIFICATE

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Dust Alert 75. *shown with optional external keypad and display

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Analog Room Pressure Monitor RPC Series

Multi-Gas-Controller MGC2

Gas cooler series TC-Standard+

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Certificate: _01 / 22 March 2013

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Certificate: _01 / 22 March 2013

1 of 25 LKS (M) SDN BHD. Floatless Water Level Control WLAPC-FL- PN16XX. SPD for Power Class B LP-75B. Industrial & Marine application Model: FLR EH

Beck. The differential pressure transmitter for air

Two-Channel Gas Controller

P R O D U C T D ATA S H E E T

Warranty Registration

Dräger Polytron 8000 Stationary gas detector (EC)

OPAL 200S SERIES OPERATOR AND SERVICE MANUAL OPAL 200 OPACITY & DUST MONITORING SYSTEM OPERATION AND SERVICE MANUAL. Feb-09 1 Revision 1 V46

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

continuous emissions monitoring Combustion & Environmental Monitoring

UV Flame Supervision System

Class 1 laser beam sensor safe for your eyes

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

APPLICATION DATA SHEET

PRODUCT CONFORMITY CERTIFICATE

Certificate: / 29 April 2014

Dräger PointGard 2100 Detection of toxic gases and vapours

UDC100 Universal Digital Controller Specifications

Zircomat Oxygen Analyzers

Snifter. User Manual. Distributor

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

The A-series Eletta Flow Monitor with local indication and analog output

RS /E-EV C01 SERIES

COMPACT FLAME CONTROLLER CFC 100

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

A New Standard of Excellence

Carbon Monoxide CO Transmitter ADT-X3-1110

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Danfoss gas detection units

P R O D U C T D ATA S H E E T

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Class 1 laser beam sensor safe for your eyes

Gas cooler series TC-Standard+ X2

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

CERTIFICATE of Product Conformity (QAL1 )

Danfoss gas detection units

Gas Controller Module GC-06

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Your competent partner for measuring and services.

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Class 1 laser beam sensor safe for your eyes

Gas cooler series RC 1.1

TR 0603mc U Solar Controller

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8310 Stationary gas detector (DSIR)

portable gas analyser

Dräger Polytron 8700 IR Detection of flammable gases and vapors

RS /E-EV C01 SERIES

Model D12-IR. Digital Gas Transmitter...

LOW NOx MODULATING GAS BURNERS

Sitron s CF Line of Flow Switch Monitors

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

An ISO 9001 : 2008 Certified Company

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Certificate: / 9 February 2011

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Sintrol Snifter A1+ Manual. Version 1.2.2

CERTIFICATE of Product Conformity (QAL1 )

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dräger Polytron 5700 IR Detection of flammable gases and vapours

/8 DIN Level Indicator

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

APPLICATION DATA SHEET

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

Recalibrate the way you look at gas detection

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Transcription:

D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust concentrations. The automatic self-alignment optimized the position of the measuring beam and prevents incorrect measurement. An automatic check of zero and referencepoints as well as a contamination monitoring. Product Overview Dust & Opacity Analyzer Combination of transmittance and scattered light measurement. For very low to high dust concentrations. Automatic check of zero and reference point. Contamination monitoring and compensation on both sides. Automatic self-alignment. For medium to large dust diameters. Application Solid Fuel Boiler Gas Fuel Boiler Tunnel for Visibility Generator Emission Diesel Car Emission Rubbish Incinerator Power Plant Boiler Furnance Waste Incinerator Field Application Emission Monitoring of power stations and waste incinerator plants. Monitoring of filter facilities. Measurement of dust concentrations in exhaust gas and exhaust air ducts up and downstream of a filter Benefits Suitable for highly fluctuating dust concentrations. Reliable application due to redundant measurement. Low maintenance due to self-monitoring function. Future-proof for decreasing limit values. Ordering Information DM-LK-D10 DM-LK-D10-C SDS-V5 SDR-V4 HPB-82S Description Dust & Opacity Meter Complete Set Controller Unit Auto Cleaner

Controller Unit Continuous monitoring in % (Opacity) and mg/m 3 (Dust). Alarm contact for exceeded limit. Aid to Efficiency of combustion. Meet to the Department of Environmental Emission Standard Regulation. Acknowledge Buzzer function. 4-20mA Analog output for Dust and Opacity. RS485 Modbus Communication. Automatic Zero and Span check. Certification CE Mark by TUV. Screen Width Power Power Consumption Ambient Temperature Alarm Contact Measuring Range Engineering Unit Mounting Panel Cut-Out Size Dimension Sampling Time Display Accuracy Operating Temperature Operating Humidity Protection Certification Report No. Conformity Emission Compensation to mg/nm3 Fail Safe Shutter Double Pass Beam D10 LCD 70 x 38mm 85-260 VAC; 50/60 Hz 20 Watt -10 ~ 50 C Max 5A / 240VAC - SPDT Relay 0-100% (Opacity), 50-1000mg/m 3 (Dust) Percent Obscuration (%) - Opacity mg/m 3 - Dust Concentration Panel or Wall W137 ± 1 x H137 ± 1 x D90 (mm) W150 x H150 x D110 (mm) 1 Kg 0.2 seconds ±1.0% F.S 0 C to 55 C 20 to 80% RH Max. (Non-condensing) IP65 Front Panel CE Mark by TUV (AE50247427 0001) 16036955 001 2004 / 108 / EC EN 61326-1 : 2013 Required Temperature & Pressure Measurement Optional Optional

Surface Wall Mounting Front View Back View Side View Flush Panel Mounting Front View Back View Side View Sensor Mounted on opposite sides of the stack or duct. light beam is at right angles to the flow or flue gases and give unrestricted illumination of the receiver solar cell. Preferable that unit installing where the temperature is at minimum. Enclosure Class Sensor Body Material Element Flange Mounting Size Air Pressurized Adapter Design Body SDS-LK-SV5 SDR-LK-RV4 IP65 Aluminium Alloy Light Emitting Diode 146mm P.C.D, Ø18mm Holes, C.T.C : 102mm 1/4" BSP Thread Weather proof IP65 Max. Ambient Temperature 70 C Max. Stack Temperature 1200 C Swing Door 90 minimum 2.0 Kg Certification CE Mark by TUV

Auto Cleaner Ambient Temperature Power Supply Material Connection Static Pressure Capacity Accessories HPB-82S 25 C and 50 C Single Phase :200-240VAC, 50Hz 3 Phase : 345-415VAC, 60Hz Cast Aluminium DN40 BSP 120 mbar 140m 3 /Hr 40Kg Hose x 10 meter, Y-Joint x 1 & Hose Clip x 6 Typical Installation RMU D10 Controller Rock Wool Insulation Cloud System OR Optional: Auto Cleaner : HP-82S PC Data Logger LKS (M) SDN BHD No.15, Jalan Anggerik Mokara, 31/63, Kota Kemuning, 40460 Shah Alam, Selangor Tel : +603-5124 0822 Fax : +603-5124 0222 E-mail : info@lkssb.com Website : www.lkssb.com