ABSTRACT I. INTRODUCTION

Similar documents
Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

Mathematical Modeling of a Sub-Wet Bulb Temperature Evaporative Cooling Using Porous Ceramic Materials

CHAPTER 2 LITERATURE REVIEW

Design and Development of Combined Direct and Indirect Evaporative Cooling System

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Two Stage Indirect/Direct Evaporative Cooling

Review on automatic vapour compression refrigeration indirect evaporative cooling-direct evaporative cooling hybrid air conditioner

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

Solar Drying Techniques And Performance Analysis: A Review

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

K.F. Fong *, C.K. Lee, T.T. Chow

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

American International Journal of Research in Science, Technology, Engineering & Mathematics

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Modified Air Cooler with Split Cooling Unit

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

American International Journal of Research in Science, Technology, Engineering & Mathematics

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Feasibility Analysis of Regeneration of Silica Gel Used in Dehumidification Process of Air Conditioning by the Condenser Waste Heat of Air Conditioner

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Design and Development of Modified Air Cooler and Storage System

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Performance of solid desiccant-based evaporative cooling system under the climatic zones of India

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

DESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT

Numerical study of heat pipe application in heat recovery systems

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Enhancement of COP using Nanoadditives in Domestic Refrigerator

EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

A Review on Potential of Indirect Evaporative Cooling System

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

The Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Recent Advances in Energy, Environment and Economic Development

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

FRESH WATER PRODUCTION USING HUMIDIFICATION AND DEHUMIDIFICATION

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Performance analysis of overlapped solar air heater using CFD

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

A Design of Thermoelectric Cooler and Optimization

Dynamic performance of a novel dew point air conditioning for the UK buildings

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

η second law = Second law efficiency

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

THE COOLING CAPACITY AND PRESSURE DROP IN A HYBRID CLOSED CIRCUIT COOLING TOWER

ANALYSIS OF DESICCANT COOLING SYSTEM

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

Desiccant-enhanced evaporative (DEVap) cooler system introduction and its comparison with direct expansion (DX) system

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

ISSN: [Ghatol* et al., 6(12): December, 2017] Impact Factor: 4.116

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Experimental Study of Alternatives to Sand in Zeer Pot Refrigeration Technique

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Scholars Research Library

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Energy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China

METHODS FOR ANALYZING THE ENERGY EFFICIENCY AND COST EFFECTIVENESS OF EVAPORATIVE COOLING AIR CONDITIONING

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

ISSN Vol.08,Issue.21, November-2016, Pages:

Green Practices Of Air Conditioning For Major Capital Cities Of India Using Advanced Evaporative Cooling

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

Transcription:

2017 IJSRSET Volume 3 Issue 2 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Study the Effect on Evaporative Cooling for Different Contact Profiles of Wetted Surfaces P. L. Sarode* 1, V. R. Baviskar 2, N. P. Salunke 3 *1 Assistant Professor, Mechanical Department, RCPIT Shirpur, Maharashtra, India 2 PG Student, Mechanical Department, RCPIT Shirpur, Maharashtra, India 3 Associate Professor, Mechanical Department, RCPIT Shirpur, Maharashtra, India ABSTRACT The aim of this review paper is to study about evaporative cooling in hot and dry climate. In this study it been observed that the how passive cooling methodology is useful in controlling surface temperature and produces cooling effects in hot climate condition, so for in this study work different materials for wall is been used also different profile shapes has been proposed for the experimentation like cylindrical, rectangular and drop like shape along with operating conditions etc. and come up with a conclusion that the contact of evaporative surface with a dry air plays an important role in the process of evaporative cooling. Keywords : Evaporative Cooling, Cooling Materials, Passive Cooling I. INTRODUCTION There are occasions where air conditioning, which stipulates control of humidity up to 50 % for human comfort or for process, can be replaced by a much cheaper and less energy intensive evaporative cooling. There are two methods of evaporative cooling i.e. direct evaporative cooling and indirect evaporative cooling. The direct evaporative cooling is very efficient and having very low cost as compare to other systems. Due to hot environment air conditioning systems are largely used, therefore electricity consumption increased[1].the two stage evaporative cooling system is more effective in hot and humid climate now a day (hot climate) demand of cooling equipment increases and in different varieties they available in market, for the human comfort evaporative cooling mostly used in terms of lower cost, lower electricity consumption, and lower ozone depletion[2]. By increasing energy crisis in the world people can used efficient equipment for cooling in building construction porous materials are more effective for cooling [3]. The evaporative cooling is a low carbon and economical method for cooling buildings in hot and dry climate. In the evaporative cooling wet media materials plays a very important role for cooling. Different materials are used such as metal foams, organic impregnated materials (Aspen), PVC padding, Celdek paper and different fibers etc.[4].porous ceramic materials are used as a wetting media in evaporators [5] In evaporative cooling systems are more effective when the maximum contact of dry superheated air with wetted surface takes place the water is absorbed the sensible heat of air due to this water vaporizes and this heat gives back to air in the form latent heat [6]. In urban area where climate is hot and dry there necessary to provide thermal comfort, there are natural covers i.e. trees and plants natural fibers replaced by building construction porous ceramic materials are used, by using this material cooling wall constructed having high water sucking ability[7]and this using this wall cooling comfort can provided[8]. Water evaporative cooling towers are suggested for high rise buildings with more than 100 floors [9]. The roof lawns are also more effective not only for cooling but also for energy conservation. Solar heating and cooling technologies are very important role plays in building construction for evaporative cooling [10]. The effectiveness of direct evaporative cooling is more as compare to indirect evaporative cooling [11]. Practically porous material or pads provide more water surface [12]. Honeycomb paper also used having more hygroscopic effect [13]. Evaporative cooling devices rejected the IJSRSET17324 01 March 2017 Accepted: 08 March 2017 March-April-2017 [(2)2: 46-50] 46

heat to the environment [14][15]. The performance of IEC is depends upon various design parameters like as wet and dry side air velocity, size of heat exchanger, mass flow rate of water on wet side, duct design factors etc. [16].some computer programs are also developed for simulating building and evaporative cooling [17]. Greenhouse is one of the important factors for evaporative cooling [18]. The direct evaporative cooling is used where environment is completely dry means there is less moisture content and indirect evaporative cooling is used where moisturized environment [19]. II. LITERATURE REVIEW Wei Chen, Song Liu, Jun Lin presents Analysis on the passive evaporative cooling wall constructed of porous ceramic pipes with water sucking ability. In this paper authors construct the pipes which made from porous ceramic and having water sucking ability. A mathematical model also developed for heat and mass transfer in saturated area of pipe and analyses the effect of ambient conditions and phase conditions on performance parameter of porous evaporative pipe. In this paper author arranges the porous ceramic pipe in three rows with staggered and parallel arrangement and check the performance. The results are temperature differences and air decreases as compared to staggered arrangement, when considered a single pipe then He concludes that porous pipe surface temperature 4-50C below the ambient temp. This system is not suitable where the shortage of water and humid climate. Mario el hourani, kamel ghali, nesreen ghadar works on Effective desiccant dehumidification system with two stage evaporative cooling for hot and humid climates. In this paper authors do the design and operation of hybrid air conditioning system using 100% fresh air and integrates solid desiccant dehumidification with two stage evaporative cooling system to optimize system operation with respect to energy and water consumption while maintaining occupant thermal comfort. He concludes that the 16.15% reduction energy consumption and 26.93% reduction in water consumption achieved by using two stage evaporative cooling system as comparing to single stage evaporative cooling system. Gerson H. dos Santos nanthan memdes presents a paper Numerical analysis of passive cooling using a porous sandy roof. In this paper author consider a mathematical model for simulating an unsaturated sandy roof considered in order to predict its effects buildings passive cooling. For predicting room air temperature and relative humidity a lumped transient approach considered for building room. He concludes the variation in room air temperature with sand and humid sand layer is very small but it causes better comfort index in all long days. Rabah Boukhanouf, Abdulrahman Alharbi, Hatem G Ibrahim and Meryem Kanzariworks on investigation of a sub-wet bulb temperature evaporative cooler for buildings. In this author presents a computer model and experimental results of an indirect evaporative cooling system in hot and dry environment. In this system porous media used as a wet media for water evaporation, Experiment carried out in 300c to 450c dry air temperature and relative humidity lower than 65%. He concludes that evaporative cooler achieve higher thermal performance in terms of low air supply temperature and effectiveness. Figure 1: Porous Ceramic Wall [1] Evaporation of wet porous pipe takes place at lower ambient relative humidity, changes in porosity will affect changing in surface temperature of pipe, more evaporation and condensation takes place with higher temperature gradient and higher vapour moving speed. Wei Chen study on Thermal analysis on the cooling performance of a wet porous evaporative plate for building in this paper he studied on wet porous ceramic evaporative plate which is used as a building wall. He also developed the mathematical model to analyse persuade of ambient conditions and the porous plate 47

thickness on the cooling performance of the porous evaporative plate. Cooling of the porous evaporative plate inside the room supplied with decreasing ambient relative humidity and increasing in ambient temperature. The ambient wind speed and the thickness of porous plate also have significance persuade on the average temperature of the porous plate. He concludes that at lower ambient relative humidity and higher ambient temperature, the rate of evaporation and vapour velocity of porous evaporative cooling plate is high. A. Fouda, Z. Melikyan presents A simplified model for analysis of heat and mass transfer in direct evaporative cooler in this paper author developed a mathematical model for describing the heat and mass transfer between air and water a direct evaporative cooler. After experiment results are taken out he had seen that in steady state conditions effect of pad thickness on the cooling efficiency gives different values of frontal air velocity, cooling efficiency decreases with increasing frontal air velocity. He concludes that the direct evaporative cooler rapidly achieves steady state conditions therefore there is no need of applying mathematical model for unsteady conations and the mathematical model is serves as a sub model of global mathematical model for direct evaporative cooling air conditioning system. Jiang He, Akira Hoyano works on experimental study of practical applications of passive evaporative cooling wall with high water sucking ability. And Experimental study of cooling effects of a passive evaporative cooling wall constructed of porous ceramics with high water sucking ability. The aim of these authors is to provide or to create cooling comfort in urban environment by controlling the increasing urban surface temperature. Here a passive evaporative wall constructed by porous ceramic material, the ceramic having capability their vertical surfaces to wet up to 100 cm. The surface temperature of pipe maintained near or equal to the wet bulb temperature outdoor air. In experiment new ceramic pipe developed, this pipe reached a height over130 cm at outdoor location in summer days and air passing over it is cooled having temperature reduced by 20c in summer days. Figure 2: Photo of Experimental Mock up [8] Figure 3: Developed Passive cooling Wall [7] Average cooling efficiency is 0.17 in summer days. The limitation of this system is not applicable in very high humid climate. B. Naticchia, M.D orazio, A.Carbonari, I.Persico presents, Energy performance evaluation of a noval evaporative cooling technique In this study authors evaluates energy performance by using some evaporative cooling techniques. For better cooling or reducing indoor temperature insulation and porous material which store the water is used in building construction. Currently Europeans and Italians work on these directions. Hoy yen Chan, Saffa B. Riffat, Jie zhu, revise the solar heating and cooling techniques, heating, ventilating, HVAC, Air conditioning systems are consumes more energy and releases large amount of carbon dioxide in environment which very harmful for 48

human comfort. In this review authors discussed on working mechanisms i.e. buoyancy and evaporative effects. X. Zhao, shuli lieu, S.B. Riffat, doing comparative study of heat and mass exchanging materials for indirect evaporative cooling systems and concludes that in terms of costing fibres are cheaper, carbons and metals cost more than fibres but less than ceramics. J. R. Camargo, C.D. Ebinuma developed a mathematical model for direct evaporative cooling air conditioning systems. This presents basic principles of the evaporative cooling system and development of mathematical thermal equations for determining effectiveness. Y.J. Dai, K. Sumath, does theoretical study on a cross-flow direct evaporative cooler using honeycomb paper as packing material and investigated. A mathematical model also developed having governing equations of liquid film and gas phases.s. Onmura, M. matsumoto, S. hokoi studied on evaporative cooling effect of roof lawn gardens and concluded cooling effectiveness increases by controlling effects of solar radiations. Boris Halasz develops a general mathematical model of evaporative cooling devices T. R. Tulsidasani, r. L. Sawhney, s. P. Singh and m. S. Sodha researched on an indirect evaporative cooler (IEC) part 1 and optimized the COP and concluded for optimum value of air velocity COP is maximum means if air velocity decreases then COP will increases which affects on cooling. E. H. Mathews, m. Kleingeld, J. Grobler studies on integral simulation of building and evaporative cooling systems and observed that if wellknown computer program used to develop building then it is easy to us suitable evaporative cooling systems provided to building for comfort cooling. T Boulard, A Ballle, developed simple green house climate control model incorporates effects of ventilation and evaporative cooling. William m. Worek, shyr tzer hsu and zalman lavan, optimized the wet- surface heat exchangers. III. CONCLUSION From the above literature review we conclude that there is a scope for further study in evaporative cooling considering the different profile shape for evaporative wall of Ceramic rod for better and effective cooling. Also there is a scope to make different arrangements for positioning of Ceramic rod in order to increase the contact of air with wetted surface. IV. REFERENCES [1]. W. Chen, Song and L. J. Lin, "Analysis on the passive evaporative cooling wall," Energy and Building, vol. 40, no. 2013, pp. 1-44, 2014. [2]. K. G. N. G. Mario El Hourani, "Effective desiccant dehumidification system with twostageevaporative cooling for hot and humid climates," Energy and Buildings, vol. 68, no. 2013, pp. 329-338, 2014. [3]. G. H. d. S. a. N. Mendes, "Numerical analysis of passive cooling using a porous sandy roof," Applied Thermal Engineering, vol. 51, no. 2012, pp. 25-31, 2013. [4]. R. Boukhanouf, A. Alharbi, H. G. Ibrahim and M. Kanzari, "INVESTIGATION OF A SUB-WET BULB TEMPERATURE EVAPORATIVE COOLER FOR BUILDINGS," Sustainable Building Conference, vol. 13, no. 2013, pp. 70-79, 2013. [5]. W. Chen, "Thermal analysis on the cooling performance of a wet porous evaporative plate," Energy Conversion and Management, vol. 52, no. 2010, pp. 2217-2226, 2011. [6]. A. F. a and Z. Melikyan, "A simplified model for analysis of heat and mass transfer in a direct," Applied Thermal Engineering, vol. 31, no. 2010, pp. 932-936, 2011. [7]. J. He and A. Hoyano, "Experimental study of practical applications of a passive evaporative cooling wall," Building and Environment, vol. 46, no. 2010, pp. 98-108, 2011. [8]. J. He and A. Hoyano, "Experimental study of cooling effects of a passive evaporative cooling wall," Building and Environment, vol. xxx, no. 2009, pp. 1-12, 2009. [9]. B. Naticchia, M. D Orazio, A. Carbonari and I. Persico, "Energy performance evaluation of a novel evaporative cooling technique," Energy and Buildings, vol. 42, no. 2010, pp. 1926-1938, 2010. [10]. H.-Y. Chan, S. B. Riffat and J. Zhu, "Review of passive solar heating and cooling technologies," Renewable and Sustainable Energy Reviews, vol. 14, no. 2009, pp. 781-789, 2010. [11]. X. Zhao, S. Liu and S. Riffat, "Comparative study of heat and mass exchanging materials for indirect," Building and Environment, vol. 43, no. 2007, p. 1902 1911, (2008). 49

[12]. J. R. Camargo, C. D. Ebinuma and S. Cardoso, "A MATHEMATICAL MODEL FOR DIRECT EVAPORATIVE," Engenharia Térmica, vol. 4, no. 2003, pp. 30-34, 2003. [13]. Y. Dai and K. Sumathy, "Theoretical study on a cross-flow direct evaporative," Applied Thermal Engineering, vol. 22, no. 2001, p. 1417 1430, 2002. [14]. S. Onmura, M. Matsumoto and S. Hokoi, "Study on Evaporative cooling effect of roof lawn gardens," Energy and Buildings, vol. 33, no. 2000, pp. 653-666, 2001. [15]. B. Halasz, "General mathematical model of," Rev Gen therm, vol. 37, no. 1997, pp. 245-255, 1998. [16]. T. R. Tulsidasani, R. L. Sawhney, S. P. Singh and M. S. Sodha, "Recent Research on Indirect evaporative cooler," International Journal of Energy Research,, vol. 21, no. 1997, pp. 1099-1108, 1997. [17]. E. H. Mathews, M. Kleingeld and L. J. Grobler, "Integrated Simulation of Buildings and Evaporative Cooling Systems," Building and Environment, vol. 29, no. 1994, pp. 197-206, 1994. [18]. T. Boulard and A. Ballle, "A simple greenhouse climate control model incorporating effects of ventilation and evaporative cooling," Agrwultural and Forest Meteorology, vol. 65, no. 1993, pp. 145-157, 1993. [19]. S. T. Hsu, Z. Lavan and W. M. Worek, "Optimization of wet- surface Heat exchangers," Energy, vol. 14, no. 1989, pp. 757-770, 1989. 50