Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Similar documents
Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

High Efficiency Heat Pump for Domestic Hot Water Generation

System Using Exhaust Heat from Residential GHPs

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Analysis of the Sub-Cooling on Refrigerating Systems Using R-410A or R-404A

Low GWP Refrigerants for Air Conditioning Applications

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Compressor Capacity Control

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Geothermal ORC Systems Using Large Screw Expanders

Efficiency of Non-Azeotropic Refrigerant Cycle

Purdue e-pubs. Purdue University

The Use Of Attic Space For Cooling and Dehumidification

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

Sub-Critical Operation of the CO2 Expander/ Compressor

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

High Efficiency R-134a Compressor for Domestic Refrigerator

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Green Roofs Impact on Buildings Cooling Load

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Control Method Of Circulating Refrigerant Amount For Heat Pump System

1. Methods of leak tightness inspection for contractors

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Dynamic Simulation of Liquid Chillers

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Air-Cooled Heat Exchanger Performance for R410A

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

Energy Efficiency of Air-to-Air Mini Heat Pump

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Investigations Of Chinese Cabbage Cold Storage Chamber Operation

Optimization Study of Absorption/Compression Cooling Cycles

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

System Modeling of Gas Engine Driven Heat Pump

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Comparison of the High Side vs

Characterization of Thermal Processes in Scroll Compressors

R32 Compressor for Air conditioning and Refrigeration applications in China

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Evaluation of Mechanical Dehumidification Concepts (Part 2)

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Leakage of Mildly Flammable Refrigerants into a Room

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Compressor Capacity Control: A New Direction

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Numerical Simulation of a New Cooling System for Commercial Aircrafts

A2L Refrigerants Leaks and Ignitions Testing under Whole Room Scale

Heat pump supplemental heating system for motor vehicles

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Smart Defrost Control for Refrigeration System

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases D. Clodic Ecole des Mines de Paris X. Pan Ecole des Mines de Paris Follow this and additional works at: http://docs.lib.purdue.edu/iracc Clodic, D. and Pan, X., "Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases" (2002). International Refrigeration and Air Conditioning Conference. Paper 607. http://docs.lib.purdue.edu/iracc/607 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

R16-1 HEAT EXCHANGER SHELVES FOR BETTER TEMPERATURE CONTROL OF FOOD IN OPEN-TYPE DISPLAY CASES Denis Clodic, Xueqin Pan Ecole des Mines de Paris, Center for Energy Studies - 60, boulevard Saint-Michel F 75272 Paris Cedex 06 Phone: +33 1 40 51 92 49 Fax: +33 1 46 34 24 91 - E-Mail: clodic@cenerg.ensmp.fr ABSTRACT Fresh food and specially meat require to be maintained at an accurate temperature level for good conservation conditions. These accurate levels require small air temperature tolerances. Open-type display cases show very high temperature differences, and even the European standard EN 441 accepts large temperature intervals associated with the defrosting process and what is known of the actual technology level. A new global design of open-type display case has been realized in order to limit drastically the temperature differences of the products depending on their position on the shelves (from front to rear). A defrosting system without heating up the cooling air has been developed. A good repartition of air on each shelf is achieved by an innovative concept, protected by a patent. The shelf itself is transformed in a heat exchanger, the airflow circulates inside the shelf and is sprayed over the food displayed on the underneath shelf. The design adapts the airflow according to the heat loads received by the food. A demonstrator of open-type display case has been realized and tested in a climatic room. Experimental results show the different level of temperatures, the air flow circulation and the level of temperature of food. Food can be maintained at a constant temperature ±1.5K. 1. STATE OF THE ART FOR TEMPERATURE CONTROL IN OPEN TYPE DISPLAY CASE Figure 1 indicates typical variations of temperatures registered in core of products displayed in common vertical fresh food display cases. Those data have been registered during 24 hours and the raise of temperature due to the opening hours of the supermarket can be noticed. The temperature peaks correspond to defrosting which occurs 4 times a day and where typical raises of temperature are in the range of 2 to 4K. Those thermal events have different impacts depending on the position of the products in the display cases as shown by the 3 curves. Those temperature variations are due to : difference in air flows received by the products difference in air flow temperatures difference in heat loads received by the products. bou_deg bou_til1 bou_til2 bou_til3 6 5 4 3 2 1 0 00:00 02:24 04:48 07:12 09:36 12:00 14:24 16:48 19:12 21:36 00:00 Figure 1 Temperature variations of products inside an open type

display-case 1.1 Temperature Differences of Products Defined by EN 441 Standard The European standard EN 441 [AFN96] takes into account all those temperature variations as indicated in Figures 2 and 3: the temperatures are measured at the core of the fake product the mean temperature calculation of the product takes into account the time period integrating the defrosting (Figure 2) the temperature differences calculated between 2 products taking into account the mean temperatures as defined previously (Figure 3). Figure 2 - Reference period of time taken into account for mean temperature calculation [AFN96]. Figure 3 Temperature differences between 2 products [AFN96]. In summary, those calculations smoothen the instantaneous variations that really affect the products. The temperature at the core of products is the one where the variations are the smallest, and the temperature peak during defrosting, which lasts typically 20 to 30 minutes, is smoothen on all the period of time without defrosting. Moreover the EN 441 standard has defined different classes of temperature control as indicated in Table 1. The best temperature control (class M1) implies a 6K mean temperature difference (between +5 and 1 C), which is clearly a significant difference of temperatures. Table 1 Temperature classes [AFN94] Class Highest temperature of the hottest pack lower or equalt to ( C) Lowest temperature of the coldest pack lower or equal to ( C) M1 +5-1 M2 +7-1 H +10 +1 2. GLOBAL DESIGN TO LIMIT RAISE OF TEMPERATURE IN THE PRODUCTS The global design of the open display case prototype is based on a detailed analysis of thermal loads on a 24-hr period [CLO02]. When accepting the constraint of an open display case, and knowing that more than 80% of thermal loads are due to the opening, the first energy efficient measure is to design an automatic night curtain [PAN00]. The other main efficient designs are shortly presently here below: defrosting without blowing air temperature raise defrosting by hot refrigerant 2 air curtains external air curtain cooled at a temperature above 0 C

new design for air repartition on products. 2.1 Defrosting Without Temperature Change To limit drastically temperature variations, the first technical concept is to defrost the air coil without affecting the air temperatures. A number of patents [MAE87], [MIL65], [RAY86], [TOS88] addresses this possibility. Basically the design is based on 2 or more air coils, permitting defrosting of one coil without air circulation; during this defrosting period, air is circulating on another air coil to maintain the blowing air temperature at the same level. On the prototype developed at the laboratory, only the main evaporator 1 operates during the basic cooling mode, while evaporator 2 is inoperative. On the contrary, during defrosting of evaporator 1, evaporator 2 operates in cooling mode. The airflow still circulates over the cold coil through a system of flaps (Figure 4) located upstream and downstream of the coils. Fans Flaps Evaporator 1 Evaporator 2 Figure 4 - System of flaps. ( C) Tp Tair TairOutletP 6 5 4 3 2 1 0-1 -2-3 -4 15000 20000 25000 30000 Figure 5 - Product and air temperatures during defrosting by hot liquid. In this display case, the air flows on a smaller air coil (evaporator 2) during the defrosting period, which is very short, because defrosting is performed by hot refrigerant getting out of the condenser. The defrosting period is required when 1K raise of temperature is noticed at the blowing port. Defrosting time is between 2 to 3 minutes, which permits to have a small coil for the defrosting period and permits also to perform as many defrostings as necessary. The registered temperatures (Figure 5) at the core of the fake product remains constant while the blowing air raises less than 1K and the air around the defrosting evaporator indicates the small raise of temperature and the fast defrosting operation time. 2.2 Double Curtain With Temperature Control Two fully independent refrigeration circuits are installed in the display case. One cools the external curtain at a temperature always above 1 C in order to avoid frosting on the evaporator of this external air circuit and permitting also to have a better energy efficiency to separate the internal ambiance of the open display case from the room air. The first curtain is installed in order to limit the introduction of room hot air (25 C). The second curtain is cooled down at the temperature permitting to maintain products at the required level (between 1 and 3 C) Air outlets Ambient air Air inlets Fans Air curtain Flaps Evaporators Cooling circuit aeraulic network Exchanger shelves Process circuit aeraulic network

required level (between 1 and 3 C). Figure 6 The display case 3. HEAT EXCHANGER SHELF Depending on the position of the product on a given shelf, the heat loads and the received cooling capacity are significantly different. Also the thermal loads received by the different shelves depend on their relative position because the air curtains create blends of room air at 25 C and of blowing air at low temperature, along the air curtain. 3.1 Heat Balance on Products At night, the external air curtain is stopped and an automated night curtain made of nylon is rolled down permitting major energy savings, and also limiting defrosting. At night the radiative heat transfer on the products is rather limited and so the daylight period is the critical one requiring adequate analysis. During day operation, the radiative heat transfers between the test room and the products inside the display case include those through the lateral glass panels and the open section. The calculation is performed with the following assumptions: the emissivity of the glass panel is equal to 0.95 in the infrared (0.7-10µm); the display case is fully filled with products, and the heat radiated through the glass panels is totally transferred to the products located behind the glass panels; the products are considered as black bodies; the walls of the room are painted grey and their emissivity ε v is 0.91; the temperatures of the products are uniform; each wall of the room is defined by its average temperature. Taking into account those assumptions, Table 2 indicates the heat loads received on the different shelves. Lateral radiative loads shown in Table 2 include both sides. The central and the bottom shelves receive more than 25% of radiative heat loads compared to the 2 others. Table 2 - Radiative heat transfer during day operation (W) Top shelf Centre shelf Bottom shelf Container Lateral radiative loads 18 29 29 10.8 Open section 94.1 113.9 113.9 108.9 Total (W) 112.1 142.9 142.9 119.7 The total radiative heat loads received by the display case from the test room during day operation is of 517W, which is 4 times higher than during night operation. 3.2 Global Air Distribution For The Two Operating Modes The air flow distribution shown in Table 3 is calculated on the the following assumptions. Air temperature at the evaporator outlet 3 C. Relative humidity at the evaporator outlet 100%. Temperature of the products in the display case, about 1 C.

Table 3 - Air flow rate distribution under the two operating conditions Night operating conditions Day operation Temperature ( C) Air flow rate (m 3 /h) Flow rate (%) Temperature ( C) Air flow rate (m 3 /h) Flow rate (%) Ceiling - 2.8 40 4.3-2.8 34 3.4 Upper shelf - 2.9 70 7.5-2.9 62 6.2 Centre shelf -2.9 73 8-2.9 65 6.5 Lower shelf - 2.9 64 7-2.9 39 3.9 Air suction port - 2.7 673 73.2-2.7 800 80 The energy and mass balances calculated on the different shelves and on the internal air curtain indicate that whatever the operating mode (night or day) 73 to 80% of the blown air circulate only along the air curtain, the remaining 20 to 27% are distributed inside the display case on the different shelves. It is consistent with the fact that the major heat load is coming from the opening of the display case. 3.3 Innovative Heat Exchanger Shelves The heat exchanger shelf design is an innovation protected by the patent [CLOD98]. The heat exchanger shelf consists of a double wall inside which the air circulates from the rear to the front of the display case. The shelf lower wall is perforated to distribute the air on to the products placed on the lower shelf (see Figure 7). Air is supplied through the opening at the rear of the double walls of the shelves in the display case rear vertical panel. Part of the airflow rate passes in the shelf space and is distributed towards to bottom through the perforated plate. The remainder of the main airflow rate is distributed to the other shelves and the air outlet of the display case. Cooling circuit Process circuit Heat exchanger shelf Rear panel Figure 7 Heat exchanger shelf The heat exchanger shelf provides a double thermal transfer: convection for the products on the lower shelf, and conduction for the products on the shelf itself. 3.4 Experimental Results Tests have been performed to compare (in the same display case) a series of conventional shelves to the new heat exchanger shelves. Figure 8 indicates for the same air blowing temperature, the temperature measured at the core of the products. The difference of temperature is of 4K.

6 Temperature ( C) 5 4 3 2 1 Product on conventional shelf Product on heat exchanger shelf 0 50000 55000 60000 65000 70000 75000 80000 85000 Time (s) Figure 8 - Effect of the exchanger shelf on the temperature of products The heat exchanger shelf cools the products faster and maintains the required level of temperature. Additional series of tests have been performed in order to analyze how fast products can be cooled inside the display case when the night curtain is rolled down. As indicated in Table 4, to lower of 1K all the products installed in the display case 9 hours are necessary on conventional shelves and only 6h 20min on heat exchanger shelves. The temperature difference between the hottest and coldest products is 2.7K with the heat exchanger shelves, whereas it is up to 5.2K with conventional shelves. Comparing the temperatures of the products displayed on the front and on the rear parts of a given shelf, the difference of temperature between the hottest and the coldest product is of 1.2K for conventional shelf and 0.6K for heat exchanger shelf. Table 4 - Effect of the heat exchanger shelf Time lag for T product = 1K T 1 product_max (K) T 2 product (K) Conventional shelves 9 h 00 5.2 1.2 Heat exchanger shelves 6 h 20min 2.7 0.6 Difference 2 h 40min 2.5 0.6 (1) the temperature difference is measured between the hottest and the coldest products taking into account all the products in the display case (2) the temperature difference between the hottest and the coldest products measured on the same shelf. In refrigerating display cases, the air is generally distributed to the products through perforations in the rear vertical panel. Circulation is complex and the difference in temperature between the rear and the front of the display case is significant. The heat exchanger shelf air flow optimizes the distribution of the air flow between the front and rear of the shelf through a different number of perforations. CONCLUSIONS Open type display cases are used in supermarkets where a large number of consumers make their shopping of fresh food, which is the usual justification of not having doors to separate the internal volume of the display case from the room. A number of research efforts have been accomplished on air curtains, but

additional efforts remain in order to avoid large variation of temperature of products. As presented in the paper, depending on the position of the product in the display case, and also depending on the defrosting design, large variations of temperatures are measured on actual display cases. Effective design are possible to limit drastically these temperature variations. Better temperature control of the products implies defrosting system without air temperature changes and a better repartition of air on the shelves taking into account the different heat loads received depending on the position. Heat exchanger shelves with air distribution realized by the shelf itself permit to provide the required airflow to maintain the products within a small difference of temperature. REFERENCES [AFN94] Refrigerated display cases. Part 6 Classification based on temperatures. NF EN 441-6. December 1994 [AFN96] Refrigerated display cases. Part 5 Temperature test. NF EN 441-5. June 1996. [CLO98] Clodic D., Heat exchanger shelves for refrigerated display case and refrigerated display case realized with such shelves. French Patent FR 98 062 08 filed on 12 May 1998. [CLO02] Clodic D. Pan X. Energy balance, temperature dispersion in an innovative medium temperature open type display case. Urban Champaign 2002. To be published. [MAE87] Maehara K. et al. Refrigerated Display Cabinet. US Patent 4,644,758 patented 24 Feb. 1987. [MIL65] Miller J.N. Three-Way Valve and System Therefor. US Patent 3,225,557 patented 28 Dec. 1965. [PAN00] Pan X. Study and modeling of a high energy efficiency display case. Ph.D. Thesis in Energy Science. Ecole des Mines de Paris, July 2000. [RAY86] Rayond G.A. Apparatus and Method For Defrosting a Heat-Exchanger in a Refrigeration Circuit. US Patent 4,565,070 patented 21 Jan. 1986. [TAS99] Tassou S.A., Datta D. Influence of Supermarket Environmental Parameters on the Frosting and Defrosting of Vertical Multideck Display Cabinets.CH-99-4-1 ASHRAE Transactions 1999, V.105, Pt. 1. [TOS88] Toshiyuki F. Refrigerated Display Cabinet. US Patent 4,741,171 patented 3 May 1988.