T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Similar documents
COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

MERIT SERIES Downflow

8+* Bulletin No November 1997

ELITE SERIES Downflow - High Efficiency Blower Motor

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

13 GEP A L P - 1 A

U n i t H e at e r s

RGE 13 A T - 1 A

True performance and rugged durability. TU, LF and LD Models

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

G34M Bulletin #69/ August 2003

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

MERIT SERIES Downflow

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

MERIT SERIES Upflow / Horizontal

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

RG7D 1-Stage Heat Series

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Downflow

SUBMITTAL SCHEDULE & DATA

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

TECHNICAL SPECIFICATIONS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

MERIT SERIES Up Flow / Horizontal

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

MERIT SERIES Upflow / Horizontal

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

DIVISION FINNED WATER-TUBE WATER HEATERS

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

GSR21Q PULSE21 SERIES

GARAGE / WORKSHOP INFRARED HEATERS

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

bring value to your space

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

2 shp 13 lc 1 36 t - 1 a

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

ML 1 80 UH 070 X E 36 B

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

TECHNICAL SPECIFICATIONS

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

INFRARED RADIANT HEATERS

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

HVAC HEATING PRODUCTS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

CATALOG: HVAC - Gas Space Unit Heating

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

T P A 120 S 4 S N 1 Y

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Transcription:

PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206 Fan View (Single fan on 045 through 50 models Dual fans on 250-300 models) Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh MODEL NUMBER IDENTIFICATION Brand/Family T = T-Class Product Line T U A 045 S N A F Voltage (blank) = 5V-ph-60Hz Unit Type U = Unit Heater Minor Design Sequence = st Revision 2 = 2nd Revision 3 = 3rd Revision Major Design Sequence A = st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Nominal Heating Capacity 045 = 40 kbtuh 00 = 00 kbtuh 25 = 25 kbtuh 50 = 50 kbtuh 250 = 250 kbtuh 300 = 300 kbtuh Gas Type N = Natural Gas L = LPG/Propane Vent Type S = Separated Fan Type F = Propeller Fan Heat Exchanger Type A = Aluminized Steel S = Stainless Steel

FEATURES AND BENEFITS CONTENTS Dimensions... 6 Features And Benefits... 2 High Altitude Information... 5 Installation Clearances... 7 Maximum Horizontal Vent Lengths... 7 Model Number Identification... Options/Accessories... 4 Specifications... 4 Venting Considerations... 5 Vent Kits And Accessories... 8 WARRANTY Aluminized Steel Heat Exchanger - Ten year limited warranty. Stainless Steel Heat Exchanger - Fifteen year limited warranty. All other covered components - Five years (045 Models only) in residential installations and one year (all models) in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS Units certified by CSA International for use with natural or LPG/propane gas (optional kit required for LPG/ Propane conversion). Units are approved for vertical or horizontal venting. ISO 900 Registered Manufacturing Quality System. APPLICATIONS 045 / 00 / 25 models are approved for both commercial and residential applications. 50 / 250 / 300 models are approved for commercial applications only. CABINET B Low-profile design on 045 models. A Constructed of pre-painted, heavy-gauge, cold rolled steel. Inside cabinet insulating panels keep outer cabinet surface temperatures low. Adjustable louvers are furnished on cabinet for control of air flow direction. External gas, line voltage and thermostat connections. Hinged door allows access to gas valve, burners, combustion air inducer and control board. Door is gasketed for tight seal. Safety interlock switch automatically shuts off power to unit when door is opened. Burner viewing port provided in door for flame viewing. Hanging brackets for suspending unit are furnished on 045 size units for field installation. See dimension drawing. TU / Page 2 B D H I G E C F Threaded inserts (3/8 in. x 6) are furnished on 00 / 25 / 50 / 250 / 300 size units for suspending unit. See dimension drawing. Support rods must be field provided. 045 size units may be inverted 80 to change gas, electrical and flue positions. See dimension drawing. HEATING SYSTEM C 24 volt redundant combination gas control valve combines a manual main shutoff valve, pressure regulation and automatic electric valve (dual) into one compact combination control. Electronic direct spark ignition control provides positive main burner ignition. Spark is intermittent and occurs only when required. Separate electronic flame sensor control assures safe and reliable operation. Should loss of flame occur, flame sensor controls will initiate 2 attempts at re-ignition before locking out unit operation for 60 minutes. Combustion air inducer pre-purges heat exchanger and safely vents flue products. Combustion air inducer proving switch proves inducer operation before allowing gas valve to open. D Tubular, Aluminized Steel or Stainless Steel Heat Exchanger Tubular heat exchanger is constructed of stainless steel or aluminized steel for superior resistance to corrosion and oxidation. Curving design of heat exchanger allows complete exposure of heating surfaces to supply air stream. Round tube surfaces create minimum air resistance and allow air to surround all surfaces for excellent heat transfer. Compact design reduces space requirements in unit cabinet.

FEATURES AND BENEFITS E F G HEATING SYSTEM (continued) Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Each burner may be removed individually for servicing. Limit Control Limit control has fixed temperature setting and protects heating system from abnormal operating conditions. Separated Combustion Combustion air is separate from the air in the heated space. Using outside air for combustion prevents dirt, lint, dust and other contaminants in the heated space from entering the combustion area of the unit heater. Combustion Air Inducer Pre-purges heat exchanger and safely vents combustion products. Blower motor has sleeve bearings and is thermally protected. Combustion Air Inducer Proving switch prevents unit operation in case of blockage of combustion air inlet. Flame Rollout Switch Manual reset switch is factory installed on 045 / 00 / 25 models. Switch provides protection from abnormal operating conditions. Options/Accessories LPG/Propane Conversion Kit Conversion kit is required for field changeover from natural gas. See Options/Accessories table. VENTING Units may be vented horizontally or vertically. Vertical Venting - Units are approved for installation with single wall and type B- double wall vent pipe. Single wall vertical vent pipe may only be used in commercial applications Double wall (type B-) vent pipe may be used for vertical venting in residential or commercial applications. Horizontal Venting - Units are approved for residential installation only with Lennox-approved stainless steel vent kits. Commercial applications may use single wall venting or stainless steel vent kits. H I Options/Accessories Horizontal Vent Kits UL listed, Cat III stainless steel vent kits are required for horizontal venting in residential applications. Optional for horizontal venting in commercial applications. Kits are available for upward or downward slope. 3 to 5 in. vent kits snap together, 6 in. vent kit include connection clamps. Kits include unit transition, vent termination and wall thimble. Upward slope kits have drain connection, 5 in. downward slope kits have double male adaptor. Provisions for hanging must be field supplied. 45 or 90 elbow is optional for ease of vent connection. Straight pipe sections in various lengths are also available. See Horizontal Vent Kits / Elbow table for Lennoxapproved Horizontal Vent Kits and accessories. See drawings for additional information. See installation instructions for detailed venting requirements. Air Intake Tee For horizontal air intake. Vertical Vent / Air Inlet Termination Cap Vent or air inlet cap for vertical venting with single wall vent pipe. See Options/Accessories table. CONTROLS The following controls are furnished as standard equipment: 24 volt main gas valve with 00% safety shutoff, direct spark ignition, main shutoff valve, gas pressure regulation (natural gas models), 5/24V transformer, low voltage terminal strip, and solid-state ignition control board with fan timer control. Combination Spark Ignition/Fan Timer Control Control contains all necessary controls and relays to operate unit. LED diagnostics provide unit operation information for improved service and maintenance. Fan timer settings: Fan on - 45 seconds fixed Fan off - 20 seconds fixed Options/Accessories Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. DIRECT DRIVE FAN All models are equipped with efficient and quiet operating direct drive propeller type fan with permanently lubricated fan motor. TU / Page 3

SPECIFICATIONS Model No. TUA045S TUA00S TUA25S TUA50S TUA250S TUA300S Gas Heating Input 40,000 00,000 25,000 50,000 240,000 300,000 Heating Capacity Output Natural Gas 32,000 8,000 0,500 20,000 94,400 240,000 PerformanceBtuh LPG/Propane 32,000 82,700 0,500 2,500 96,800 243,000 Connections - in. Thermal Efficiency Natural Gas 80% 8% 8% 80% 8% 80% LPG/Propane 80% 82% 8% 8% 82% 8% Temperature Rise - F 45 3 39 38 35 43 Flue Size (round) 3 5 5 5 5 6 Combustion Air Size (round) 3 4 4 4 4 4 Gas Piping Size /2 /2 /2 /2 3/4 3/4 Fan Data Number of Fans 2 2 Fan Diameter - in. 0 6 6 8 6 6 Number of Blades 5 4 4 4 4 4 Motor Output - hp /20 /8 /8 /8 /8 /8 Amps.7 2.7 2.7 2.7 2.7 2.7 rpm 650 075 075 075 075 075 Motor Type SP PSC PSC PSC PSC PSC Air Volume - cfm 750 2435 2435 2955 525 525 Air Flow (ft.) at 8 ft. mounting height 25 50 50 80 00 00 Electrical Characteristics 5 volts - 60 hertz - phase Total Unit Amps 3 6 6 6 9 9 Shipping Weight - lbs. ( package) 84 88 204 26 307 323 OPTIONS/ACCESSORIES Horizontal Vent Air Intake Tee Model No. TUA045S TUA00S TUA25S TUA50S TUA250S TUA300S C5VENTT3T - 3 in. 75W85 - - - - - - - - - - - - - - - C5VENTT4T - 4 in. - - - 75W86 75W86 75W86 75W86 75W86 LPG/Propane Kit 6H69 82M94 82M94 82M94 82M94 82M95 Vertical Vent Air Inlet Termination Cap Vertical Vent Termination Cap 3 in. 82M90 - - - - - - - - - - - - - - - 4 in. - - - 82M9 82M9 82M9 82M9 82M9 3 in. 82M90 - - - - - - - - - - - - - - - 4 in. 82M9 - - - - - - - - - - - - - - - 5 in. - - - 82M92 82M92 82M92 82M92 - - - 6 in. - - - - - - - - - - - - - - - 82M96 HORIZONTAL VENT KITS AND ELBOW REQUIRED FOR RESIDENTIAL HORIZONTAL VENTING APPLICATIONS - OPTIONAL FOR COMMERCIAL APPLICATIONS Unit Heater Model No. Vent Dia. (in.) Upslope Vent Kit Catalog No. Downslope Vent Kit Catalog No. 45 Elbow TUA045S 3 C5VENT3KU 75W62 C5VENT3KD 75W66 C5VENT3E45 (Optional) TUA00S TUA25S TUA50S TUA250S 5 C5VENT5KU 75W64 C5VENT5KD 75W68 C5VENT5E45 (Optional) TUA300S 6 C5VENT6KU 75W65 C5VENT6KD 75W69 C5VENT6E45 (Optional) Length does not include termination (or elbow if used). Catalog No. 87W79 87W8 87W82 90 Elbow Catalog No. C5VENT3E (Optional) C5VENT5E (Optional) C5VENT6E (Optional) Minimum Vent Length (ft.) 75W70 3 75W72 5 75W73 5 TU / Page 4

STRAIGHT VENT PIPE - FOR HORIZONTAL VENTING Unit Heater Model No. Vent Diameter (in.) Length (in.) Catalog No. TUA045S C5VENT3P6 3 6 75W74 TUA00S, TUA25S TUA50S, TUA250S C5VENT3P2 3 2 75W75 C5VENT3P36 3 36 75W76 C5VENT5P6 5 6 75W80 C5VENT5P2 5 2 75W8 C5VENT5P36 5 36 75W82 TUA300S C5VENT6P2 6 2 75W83 C5VENT6P36 6 36 75W84 VENTING CONSIDERATIONS NOTE - Concentric Venting is not approved for use with the TU unit heaters. Air for combustion and supply air ventilation must conform to the methods outlined in American National Standard (ANSI-Z223.) National Fuel Gas Code or National Standard of Canada CSA-49., & CSA-49.2 Installation Code for Gas Burning Appliances. Horizontal Venting Residential horizontal venting requires the use of a Lennox-approved Cat III Horizontal Vent Kit and Vent Pipe. Commercial applications may use single wall venting or stainless steel vent kits. The maximum permissible horizontal vent length is 25 ft. with one 90 elbow. Minimum horizontal vent length is 5 ft. One elbow is equivalent to 5 ft. of vent pipe. Horizontal venting must terminate in a tee. Vertical Venting Single wall vertical vent pipe may only be used in commercial applications. Double wall (type B-) vent pipe may be used for vertical venting in residential or commercial applications. Maximum vertical vent and vent connector lengths - In the U.S. refer to the American National Standard (ANSI-Z223.) National Fuel Gas Code or in Canada the National Standard of Canada CSA-49. Clearances Minimum clearance to combustible material is 6 in. with single wall vent pipe. See Installation Instructions for additional venting information. HIGH ALTITUDE INFORMATION Units may be fired at full input up to 2000 ft. above sea level. Above 2000 ft., manifold pressure must be reduced by 4% for each 000 feet above sea level or as specified by local authority having jurisdiction. Adjust pressure regulator to pressure shown in tables. The combustion air inducer proving switch is factory set. No adjustment is necessary. NOTE - This is the only permissible derate for the units. Model No. Manifold Pressure - in. w.c. ft. 0-2000 200-3000 300-4000 400-5000 500-6000 600-7000 700-8000 800-9000 900-0,000 Natural Gas TUA045S 3.5 3.4 3. 2.9 2.7 2.4 2.2 2.0.8 TUA00S, TUA25S 3.5 2.7 2.5 2.2 2.8.6.4.3 LPG/Propane Gas TUA045S 9.5 8.3 7.6 7.0 6.5 6.0 5.5 4.9 4.3 TUA00S, TUA25S, TUA50S, TUA250S, TUA300S No adjustment required. 9.0 7.0 6.4 5.8 5.2 4.7 4.2 3.7 3.2 TU / Page 5

DIMENSIONS - INCHES (MM) MOUNTING SLOTS (Typical) 5/6 x 3 Inches (8 x 76 mm) 045 MODEL 7-/4 (84) 3-/4 (83) 3 (330) HANGING BRACKETS 3 (330) 7 (78) (2) 3 (76) (25) /2 (3) AIR FLOW 8-/2 (470) HEAT EXCHANGER 5-/2 (40) (25) 8-/2 (470) HANGING BRACKETS (2) GAS INLET 5-3/4 (46) TOP VIEW 26 (660) (25) SERVICE ACCESS DOOR FLUE OUTLET 7-3/4 (97) 2 (305) 5-/4 (33) BURNER VIEWING PORT ADJUSTABLE LOUVERS SIDE VIEW THUMB SCREW -3/4 (44) ELECTRICAL BOX COMBUSTION AIR INLET BACK VIEW DIRECT DRIVE FAN TU / Page 6

DIMENSIONS - INCHES (MM) 00 / 25 / 50 / 250 / 300 MODELS THREADED STUDS 24 7/6 (62) 5 /2 (40) AIR FLOW 32 3/8 (822) 2 5/6 (54) HEAT EXCHANGER 7 /4 (84) /2 (3) TOP VIEW 32 3/8 (822) THUMB SCREW 7 3/8 (87) 36 /2 (927) FLUE OUTLET DIRECT DRIVE FAN B SERVICE ACCESS DOOR ELECTRIC BOX A 7 (78) ADJUSTABLE BURNER VIEWING LOUVERS PORT SIDE VIEW GAS INLET 7 3/4 (97) COMBUSTION AIR INLET BACK VIEW TUA250 and TUA300 models have two fans. Model No. TUA00S TUA25S TUA50S TUA250S TUA300S in. mm in. mm in. mm A 2 533 27 686 39 99 B 8-/2 26 8-5/8 29 22-/2 572 INSTALLATION CLEARANCES - IN. (MM) Model No. 045 / 00 / 25 Models 50 / 250 / 300 Models Top (25) 6 (52) Side opposite access panel (25) (25) Access Panel Side 8 (457) 8 (457) Back 8 (457) 8 (457) Bottom 0 (0) 0 (0) Single wall vent 6 (52) 6 (52) NOTE - Provide adequate clearance for servicing. See Installation Instructions for additional installation considerations. Except for listed clearance thimbles. MAXIMUM HORIZONTAL VENT LENGTHS No. of Elbows Maximum Length (ft.) of Straight Vent Pipe 45 Model 00 / 25/ 50 / 250 / 300 Models 25 25 2 20 20 3 5 5 4 0 0 5 5 5 TU / Page 7

VENT KITS AND ACCESSORIES HORIZONTAL VENT KITS (UPSLOPE) 3 AND 6 INCH HORIZONTAL VENT KITS (DOWNSLOPE) 5 INCH HORIZONTAL VENT KIT (DOWNSLOPE) STRAIGHT PIPE (Typical) 45 ELBOW (Typical) 90 ELBOW (Typical) HORIZONTAL VENT AIR INTAKE TEE TU / Page 8

REVISIONS Specifications Section Heating input revised for TUA-045 models. Description of Change Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 207 Lennox Industries, Inc.