Hot Issues in Fire Engineering July 2014

Similar documents
Evacuation Hazards in Crowded Subway Stations

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Hot Issues in Fire Engineering 28 February 2012

NECESSITY OF IN-DEPTH EVALUATION OF LONG-THROW SPRINKLER INSTALLATION AT TALL ATRIA STORING HIGH AMOUNTS OF COMBUSTIBLES

CFD Analysis of Fire Characteristics on Subway Junction Station

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Comment on Hawker Stall Fires

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

SHOULD SMOKE MANAGEMENT SYSTEM BE PROVIDED IN KARAOKE ESTABLISHMENTS?

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

ASPECTS OF FIRE SAFETY IN ULTRA HIGHRISE BUILDINGS

Hot Issues in Fire Engineering 12 March 2013

Crossrail Fire Safety Designs

Simulation of Emergency Evacuation in the Arrival Hall of a Crowded Airport

Underground fires in metro systems failures, accidents and terrorism

Sprinklers Modeling for Tunnel Road Fire Fighting

On Estimating Heat Release Rate for a Design Fire in Sprinkler Protected Area

F I R E A L A R M R E C O G N I T I O N A N D E X I T C H O I C E I N U N D E R G R O U N D S TAT I O N S

Case Study of Underground Car Park. Team Japan

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

Tunnel Fire Dynamics and Evacuation Simulations

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

THE COMPARISON OF THE RESULTS OF A FULL SCALE EVACUATION TEST TO THE CALCULATION METHOD OF HUNGARIAN REGULATIONS AND TO THE PATHFINDER SOFTWARE

Case Study 1 Underground Car Park

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

Provisions for the Means of Escape and Means of Access by Using Lifts and Escalators in the MTRC Main (U/G) Station

Statue of Liberty: A Risk Analysis

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

NECESSITY OF CARRYING OUT FULL-SCALE BURNING TESTS FOR POST-FLASHOVER RETAIL SHOP FIRES

Simulation of Full-scale Smoke Control in Atrium

OBSERVATION ON THE TWO RECENT BUS FIRES AND PRELIMINARY RECOMMENDATIONS TO PROVIDE FIRE SAFETY

Risk-informed Airport Fire Engineering Solutions for Operational Continuity

Considerations in the Design of Smoke Management Systems for Atriums

Fire Hazard Analysis of Technical Area 53 Building 1

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

Smoke Management in Subway Stations Due to Train Arson Fire Scenario

Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Practicalities and Limitations of Coupling FDS with Evacuation Software

Virtual Compartment: An Alternative Approach to Means of Egress Design in Airport Pedestrian Tunnel

Case Study 1 Underground car park

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

Crossrail Project. Infrastructure design and construction Volume 5. Edited by Professor Rhys Vaughan Williams and Mike Black

A Study on the People Evacuation Safety for the. Underground MRT Station

SURVEY ON FIRE SERVICE INSTALLATIONS FOR OFFICE BUILDINGS IN HONG KONG

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

A Brief on Performance- Based Design for Building Fire Safety

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

Crossrail. Clare Hebden; September 2012

System development and performance evaluation of track intrusion in Taipei MRT system

Advantages and Disadvantages of Fire Modelling

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

ASSESSING FIRE SAFETY PROVISIONS FOR SATISFYING GREEN OR SUSTAINABLE BUILDING DESIGN CRITERIA: PRELIMINARY SUGGESTIONS

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

Fire Protection and Safety in Tunnels Conference Opening Remarks. Dr Fathi Tarada Secretary, PIARC Tunnel Operations Committee

Case Study for Performance-Based Design in Hong Kong

How design fires can be used in fire hazard analysis

FULL-SCALE BURNING TESTS FOR RETAIL SHOP FIRES: PRELIMINARY STUDIES

ASHINGTON BLYTH & TYNE RAIL RE-OPENING PROJECT. The Case For A Station at SEGHILL

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

Evacuation Mode for Total Building Evacuation

Fire Engineering in High Rise 15 November 2013

Potential Impact of New UL Fire Test Criteria

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

VENTILATION & FIRE SAFETY

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

EVACUATION MODELING DEPENDENCE ON INPUT PARAMETERS

Comparative Evaluation Method for Fire Safety Design of Large Storage Spaces

The Study of Evacuation Times from the Multiplex Theatres

DENVER INTERNATIONAL AIRPORT. Photo provided courtesy of Denver International Airport

EVACUATION MODELLING IN ROAD TUNNEL FIRES

OPTIMIZING GYMNASIUM EVACUATION PERFORMANCE BY AGENT-BASED SIMULATION. Cambridge, United States

Simulation study of evacuation in high-rise buildings

Recent BRANZFIRE enhancements and validation

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

Mass Notification and Intelligent Response TM The European Way

Research Needs for the Fire Safety Engineering Profession

Executive Review Panel Report on Arson Incident

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

TOD Planning in China: Problems and Solutions. Yin Jia, Founder, EFC Engeering Consulting Co. Ltd.

Road tunnel safety rules in Italy: the tunnel country

Fire Protection System and Life Safety Evaluation of Building X. Anthony W. Sublett

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

Practical problems of applying performance-based structural fire engineering in building design

4.13 Security and System Safety

Modeling a real backdraft incident fire

Predictions of Railcar Heat Release Rates

Nightclub Fires in 2000

Date: Place: Technical University of Denmark. Knowledge FOr Resilient society

Planning Underground Urban Space Where, When and How?

To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

Transcription:

Hot Issues in Fire Engineering July 2014 Crowded Railway Stations and Train Compartments to Watch Y.W. Ng and W.K. Chow, JP FHKEng Research Centre for Fire Engineering, Department of Building Services Engineering The Hong Kong Polytechnic University, Hong Kong, China 1. Introduction Mass transit in Hong Kong has over 4 million passengers every day [1]. A large proportion of local citizens use this means of transport to travel between residential complexes and workplaces. Visitors from 49 mainland cities under the Individual Visit Scheme use it also since 2003 [2]. The railway stations and train compartments are then crowded with passengers most of the time. Further, many incidents happened recently in the local subway system that made the situation of crowded stations and train compartments even worse [3]. Over 70,000 passengers were affected up to 2011 as reported by the Principal Author [4]. Consequently, members of Legislative Council are very concerned with crowdedness in train compartments. A legislator said that he had to wait for 10 trains at an interchange station for transit [5]. Normal evacuation in a crowded station would take a long time. Emergency evacuation would be very difficult to control. In addition, passengers frequently carry large amounts of baggage and goods into the station in recent years. Many mainland visitors even bring trolleys and large suitcases. The type and fire loads of such baggage and goods are not known. It is doubtful whether the dynamic smoke extraction systems in stations are able to perform its functions effectively and efficiently. Large suitcases and trolleys will not only occupy more spaces but will also impede the efficiency of evacuation in the event of fire or other emergencies. The situation will be aggravated when passengers gather at the station exit gates after leaving the train compartment. The behaviour of commuters in the event of fire is difficult to be predicted. Despite the provision of broadcasting system, directional and exit signage, it is uncertain whether people will escape in the directions as planned. In general, partial evacuation is adopted in railway stations depending on the magnitude of the fire. If a fire occurs at the platform level, passengers will be directed to evacuate upwards 1

to the concourse level. If a fire breaks out on the concourse, commuters will be evacuated from the fire zone to the adjacent zone on the same level. It is assumed that smoke in the fire zone will be completely extracted by the dynamic smoke extraction system. However, as mentioned earlier, it is difficult to predict the behaviour of commuters in the event of fire or other emergencies. In principle, the concourse level is designed mainly for entrance and exit while the platform level is solely for embarking or debarking from the train. Therefore, it was presumed 30 years ago that the things carried by passengers into station and train compartments are mainly personal belongings or hand-carrying bags. The fire load and fire size should be small. As mentioned earlier, more baggage is now being carried by passengers into the stations, lifting both the fire load and design fire size. Such change should not be neglected and continuous review is necessary for fire safety. 2. Timeline Analysis As reported before [6-8], timeline analysis has been applied to determine fire safety provisions through performance-based design for many large-scale constructions that have difficulties to comply with the prescriptive fire safety codes. Both the Available Safe Egress Time (ASET) and the Required Safe Egress Time (RSET) are estimated and compared. Small fire scenarios of only up to 5 MW were used in large halls in subway stations to obtain longer ASET. RSET was not estimated under crowded conditions to give small values of evacuation time. The safety margin was only taken as a small percentage of RSET. As a realistic fire might have much higher heat release rate, a smaller value of ASET will be resulted. Therefore, a higher safety margin of multiples of ASET should be provided in new projects to cater for uncertainties. A two-level [9,10] railway station was used to illustrate the problems encountered using timeline analysis. Fire simulations were carried out to predict the ASET under low design fires. When using Computational Fluid Dynamics (CFD), the tenability due to smoke toxicity included only carbon monoxide. Evacuation simulations were conducted to predict the RSET under low passenger loadings. The railway station was 120 m long, with two platforms of widths 18 m and 9 m respectively. There were two tracks along platform 1 with two stairs connected to outside. One track was built on the side of platform 2. The floor areas of platform 1 and platform 2 were 5400 m 2 and 6000 m 2 respectively. There was only one exit in this station on platform 2, as shown in 2

Fig. 1. There were two passenger accesses on the second level connecting platform 1 and platform 2. Passengers on platform 1 must use the accesses to reach the station. Passengers may carry large amounts of luggage in some stations. The tests used bigger fires due to greater air supply by natural ventilation system in the station. Two fire sizes of 5 MW and 25 MW representing different types of fire were chosen to assess the effect of fire size on ASET. Timeline analysis on the stairs of platform 1 was carried out, with its ASET and RSET shown in Fig. 2. Under normal circumstances, subway stations are designed to accommodate only 720 persons. Most scenarios are located in the safe region of the ASET-RSET curve. However, for a heavy occupant loading of 0.5 m 2 /person or 2 person/m 2 (the figure was 6 persons/m 2 in a train car), 7280 persons would stay in the station. Full evacuation would take a long time, therefore RSET is longer than ASET even under a small fire. As no smoke barriers were placed between the fire sources and stairs, smoke would quickly spread to the nearest stairs even in a very small fire. Although the above analysis illustrates that some remote places and exits give long ASET, passengers must be guided to move instantly in case of fire. There are great variations in capabilities and physical conditions of passengers involved in a fire [6]. Passengers will not move to the designated exit like robots in a real fire. It may be difficult to upgrade hardware provisions in existing stations, so fire safety management must be enhanced in existing stations. The fire safety plan should be worked out carefully for large, crowded and deep underground stations. Fire safety management must be enhanced in existing projects with low safety margin, long ASET based on small fire scenarios and short RSET with low design occupant loading. Such application is urgently needed in crowded areas of subway stations without adequate fire safety provisions. 3. Way Forward The train compartments and stations of most existing railway lines were designed in the 1980s and 1990s to hold a maximum of 6 persons/m 2 or 0.167 m 2 /person. For new projects, fire scenarios with higher heat release rates should be applied to derive reasonable values of ASET including fractional effective dose (FED) [11]. Higher safety margin of multiples of ASET should be provided to cater for uncertainties. Effort was made to mitigate the problem of crowdedness, such as by strengthening passenger flow management, purchasing new trains 3

and increasing train frequency. However, these actions might not improve the efficiency of evacuation. A comprehensive review on how to enhance the efficiency of evacuation and tenable condition for evacuation of the existing railway lines should be conducted. As it would take time to implement long-term measures, immediate action should be carried out as soon as possible to ensure that the design fire scenario and passenger loading match with the performance-based design report. For existing subway stations, immediate actions to take [12] are: For stations with ASET much larger than RSET, say slope of 2 as in Fig. 2, no upgrading works are needed. For stations with ASET close to RSET, the amount of combustibles carried by passengers should be limited and the management ought to implement emergency evacuation scheme to match better with those robotic motions [6] assumed in the simulations. This practice must be implemented immediately in crowded areas such as public transport interchanges and deep underground subway stations without adequate fire safety provisions. Stations with ASET shorter than RSET should be considered to closing or at least enhancing better management even under normal operation. In response to lawmakers on alleviating the crowdedness of stations and train compartments, the local subway system has already taken some actions [13]: Better passenger flow management; Purchasing more new train cars; Replacing signalling systems; Ensuring the timely completion of new railways; Increasing train frequency; and Exploring the feasibility of removing some seats from overcrowded train compartments. The carrying capacity of trains has increased [14] with the fare concession scheme launched [15] to encourage some commuters to take their subway rides during non-peak hours. Effectiveness of these actions should be watched. 4

References 1. Mass Transit Railway Corporation Limited, Annual Report 2012, p. 14, 11 March (2013). 2. Commerce and Economic Development Bureau, Assessment Report on Hong Kong s Capacity to Receive Tourists, p. 3, December (2013). 3. Apple Daily, 港鐵一日多次故障, 11 July (2014). http://hk.apple.nextmedia.com/news/art/20140711/18796180 [Accessed: 22 July 2014] 4. W.K. Chow, Lu Qu and Edgar C.L. Pang, Incidents on fire and ventilation provision in subway systems in Hong Kong, International Journal on Engineering Performance-Based Fire Codes, Vol. 10, No. 3, p. 41-47 (2011). 5. Legislative Council, Debate Theme: Economic Development, Official Record of Proceedings, 9 May, p. 6383 (2014). 6. V. Babrauskas, J.M. Fleming and B.D. Russell, RSET/ASET, a flawed concept for fire safety assessment, Fire and Materials, Vol. 34, p. 341-355 (2010). 7. W.K. Chow, Letter to the Editor: Comment on RSET/ASET, a flawed concept for fire safety assessment by V. Babrauskas, J.M. Fleming and B.D. Russell, Fire and Materials, Vol. 34, pp. 341-355 (2010), Fire and Materials, Vol. 37, No. 3, p. 257-258 (2013). 8. W.K. Chow, Six points to note in applying timeline analysis in performance-based design for fire safety provisions in the Far East, International Journal on Engineering Performance-Based Fire Codes, Vol. 10, No. 1, p. 1-5 (2011). 9. W.K. Chow and L. Qu, Fire hazard assessment for a green railway station, Fire and Materials, Vol. 38, No. 4, p. 451-461 (2014). 10. L. Qu and W.K. Chow, Common practices in fire hazard assessment for underground transport stations, Tunnelling and Underground Space Technology, Vol. 38, p. 377-384 (2013). 11. N. Saunders, P. Beever, C. Wade, C. Fleischmann, M. Feeney, D. Scott and P. Thorby, A new framework for performance-based fire engineering design in New Zealand, Proceedings of 9th International Conference on Performance-Based Codes and Fire Safety Design Methods, 20-22 June 2012, Hong Kong, China (2012). 12. C.L. Shi, M.H. Zhong, X.W. Tu, T.R. Fu and L. He, Deep Underground Subway Station Fire Experiment and Numerical Analysis, Science Publisher, Beijing, China (2009) In Chinese. 13. S. LEE, Alleviation of crowdedness of MTR train compartments, LegCo Questions and Replies, 19 March (2014). 14. Skyscraper City, Hong Kong metro seats may be scrapped for smartphone space (2014). Available from: 5

http://www.skyscrapercity.com/showthread.php?t=122558&page=139&langid=5 [Accessed: 26 April 2014] 15. A. Lee, MTR urged to review capacity measures to ease train crowding, South China Morning Post, 26 April (2014). HIFESNg1d 6

Fire Passenger access Platform 1 70 m Exit Two tracks 55 m 120 m One track Platform 2 Fig. 1: Geometry of the railway station (Qu and Chow 2013) 7

1500 5 MW ASET = 2RSET ASET = RSET 1000 Safe region ASET (s) 500 25 MW Unsafe region E1 Normal 720 persons in station E2 Crowded 7280 persons in station 0 0 500 1000 1500 RSET (s) Fig. 2: Timeline Analysis of ASET and RSET for Platform 1 (Qu and Chow 2013) 8