ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

Similar documents
Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

The ultimate fresh air solution.

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Heat pump and energy recovery systems

Heat Recovery Units. Heat Recovery 1

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

100% Outdoor Air Dehumidification Methods

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

CHAPTER 4. HVAC DELIVERY SYSTEMS

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

1.1 This section applies to air handling units for HVAC Systems.

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

RT-OA TM Rooftop Outdoor-Air (DOAS)

VertiCool Aurora Engineering Guide

C13-Series Engineering Guide

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Energy Recovery with Cooling and Heating

Designing Energy Efficient Outdoor Air Systems

APC APPLICATION NOTE #109

SEALED ENCLOSURE COOLING

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

39G Air Handling Unit

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Technical Development Program

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Pharmaceutical Facility Design

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

SMALL AIR COOLED CONDENSERS

Daikin Blueprint: Delivering Hot Water with a Chiller

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

CTI Sponsored Educational Program

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

EHH SERIES DRAW THROUGH FAN COILS CFM

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Energy Recovery Ventilation

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

COMcheck Software Version Review Mechanical Compliance Certificate

Air-Handling System Cooling Options

2009 IECC Commercial Mechanical Requirements

Greensource Residential Geothermal Heat Pumps. Think Green Think Renewable Think. iseries: SV Model Split System. boschheatingandcooling.

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

GUIDE SPECIFICATIONS AQUARIUS ii

Air-Handling System Cooling Options

Case 13 Food Storage & Processing Center

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

RT-OA TM Rooftop Outdoor-Air (DOAS)

Double Skin Casing Air Handling Units

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

NOREN Products. Compact Cabinet Coolers

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

ENCLOSURE COOLING. Glossary

Union County Vocational - Technical Schools Scotch Plains, New Jersey

REFRIGERANT AND WATER HEAT PIPES D E H U M I D I F I C A T I O N

VERTICAL FAN COIL UNITS

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Our energy efficient experts and engineers have made ground breaking innovations in this field.

AHRI Certification Program Scopes - COOLING

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Heating and Cooling Coils

Computing Services Center

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

CONTROLLED CHILLED BEAM PUMP MODULE

Greensource Residential Geothermal Heat Pumps. Invisible Comfort. Si Series: CE Model. boschheatingandcooling.com

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Cabinet Unit Heaters Steam / Hot Water

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data

HVAC DISTRIBUTION and DELIVERY SYSTEMS

2. CURRICULUM. Sl. No.

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Scholar III Unit Ventilator

Transcription:

WAHX (WRAP-AROUND) AAHX (AIR-TO-AIR) ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS HVAC PRODUCT GUIDE

THERMAL MANAGEMENT EXPERTS ADVANCED COOLING TECHNOLOGIES, INC. IS A PREMIER THERMAL MANAGEMENT SOLUTIONS COMPANY. We serve our customers thermal management and energy recovery needs in diverse Markets including Defense, Aerospace, Electronics, HVAC, Medical Devices, Enclosure Cooling and Calibration Equipment. We specialize in providing performance and cost optimized thermal management technologies and solutions that meet the unique needs of each customer. Our diverse product portfolio maximizes our ability to meet our customers performance, cost and reliability requirements. ACT is the only U.S.-based Heat Pipe manufacturer that routinely ships Heat Pipe products for terrestrial, spacecraft, and high temperature applications. Our HVAC Wrap-Around and Air-to-Air Heat Exchanger products are in operation throughout the world, improving energy efficiencies of building HVAC systems and industrial processes. ACT is strongly committed to our customers, employees, and community. Innovation, Teamwork and Customer Care are the core values that drive the continuous growth of our company. TABLE OF CONTENTS HVAC Heat Pipe Operation and ACT HVAC Energy Recovery Systems pg. 3 Wrap-Around Heat Pipe Exchangers (WAHX) pg. 4-5 WAHX Heat Pipe with Control pg. 6-7 Air-to-Air Heat Pipe Exchangers (AAHX) pg. 8-10 Online Selection Tools pg. 11 WAHX Traditional Dimensions pg. 12 WAHX Split Loop Thermosyphon Dimensions pg. 13 AAHX Traditional Dimensions pg. 14 AAHX Split Loop Thermosyphon Dimensions pg. 15 WWW.1-ACT.COM/HVAC 2

HVAC HEAT PIPE OPERATION HVAC HEAT PIPE OPERATING PRINCIPLE Heat pipes function by absorbing heat at the evaporator end of the cylinder, boiling and converting the fluid to vapor. The vapor travels to the condenser end, rejects the heat, and condenses to liquid. The condensed liquid flows back to the evaporator, aided by gravity. The phase change cycle continues as long as there is heat (warm outside air) at the evaporator end of the heat pipe. This process occurs passively (no external electrical energy required). EVAPORATOR HEAT IN Working fluid vapor flows through center CONDENSER HEAT OUT HEAT IN HEAT OUT ACT HVAC ENERGY RECOVERY SYSTEMS ACT ENERGY RECOVERY TYPES WRAP-AROUND HEAT PIPE EXCHANGERS (WAHX) PASSIVE AIR-TO-AIR HEAT PIPE EXCHANGER (AAHX) 3

WRAP-AROUND HEAT PIPE (WAHX) HOW DOES A WRAP-AROUND HEAT PIPE HEAT EXCHANGER WORK? OUTSIDE AIR HEAT PIPE COOLING DELTA T PRE-COOL COIL DELTA T HEAT PIPE RE-HEAT 102 /77.8 15.6 86.4 /73.7 52.5 /52.4 15.5 68.0 /58.6 92 /77.7 15.2 76.8 /69.4 52.5 /52.4 15.1 67.6 /58.5 82 /68.8 11.3 70.7 /65.2 52.5 /52.4 11.3 63.8 /57.0 72 /63.7 7.5 64.5 /61.0 52.5 /52.4 7.5 60.0 /55.5 62 /56.4 3.6 58.4 /55.0 52.5 /52.4 3.6 56.1 /54.0 52 /52.4 0.0 52.5 /52.4 52.5 /52.4 0.0 52.5 /52.4 AHU: 20,000 CFM 4 Rows of Heat Pipes 12 Fins per inch W AHX CONFIGURATIONS PIPE TO PIPE CONNECTION EVERY ROW EVERY PIPE Any Coil Dimensions Stackable Controllable SPLIT LOOP THERMOSYPHON 2 PIPES PER ROW Any Length Coil Max 37 Fin Height Stackable Controllable WWW.1-ACT.COM/HVAC 4

WRAP-AROUND HEAT PIPE (WAHX) BENEFITS Energy Savings Free pre-cooling (lower tonnage AHU systems) Free re-heat (no electric, steam or hot water cost) Passive System No maintenance No moving parts (except for control valves when applied) Enhanced Dehumidification Lower entering air conditions (ex: 95º to 85º) Lower cooling coil discharge temperature Neutral Air Discharge (free re-heat) Meets Energy Code Requirements for Chilled Water DOAS AHUs Lower Static vs. Other Energy Recovery Types FEATURES 1/2 Rifled Copper Tubes for Enhanced Thermal Performance Aluminum Fins (8-14 Fpi) Galvanized Steel Casing Factory Installation, Field Installation or AHU Manufacturer Installation R-134a Up to 10 Rows OPTIONS Up to 1 Coil Tubes (Copper or Aluminum) Stainless Steel Casing Multiple Fin Types & Materials Controllable (Active or Passive) Coil Coating (E-Coat or Heresite) R-410A 5

WAHX HEAT PIPE WITH CONTROL AVOID OVER-COOLING THE SPACE WHILE MAXIMIZING SAVINGS WRAP-AROUND HEAT PIPE PERFORMANCE MEETING REHEAT AND DESIGN POINT TARGETS WITH ADDITIONAL ROWS 92 F Design Point 200 175 150 125 2 ROWS 3 ROWS 4 ROWS 5 ROWS 6 ROWS 65 F Reheat Goal MBH 100 75 50 25 Chart 1 50 55 60 65 70 75 80 85 90 95 OUTDOOR TEMPERATURE F FORT LAUDERDALE, FLORIDA ANNUAL BIN TEMPERATURE DATA For this example the largest band of energy savings occurs within the circle. NUMBER OF HOURS/YR AT TERMPERATURE 2,500 2,000 1,500 1,000 500 50 55 60 65 70 75 80 85 90 95 OUTDOOR TEMPERATURE F Chart 2 TECHNICAL PARAMETERS UTILIZED: Annual Data - Running Hours 24 Hrs/Day 7 Days/Week (Note: Temperatures below 57.5 F are not calculated). System Assumptions: 17,500 CFM system, operating in Fort Lauderdale Florida, Cooling Coil at 55 FDB/54.9 FWB. WWW.1-ACT.COM/HVAC 6

WAHX HEAT PIPE WITH CONTROL CONSIDER ACT S CONTROL VALVES FOR OPTIMIZED WRAP-AROUND HEAT PIPE ENERGY PERFORMANCE In order to capture and transfer even more energy, ACT s control valve options increase the ability of the WAHX to have a wider range of energy savings operation at lower entering air temperatures. ACT control valve options permit additional heat pipe rows, resulting in higher capacity WAHX systems with the capability of stopping refrigerant flow in selected rows to maintain a specified discharge temperature. WAHX control maximizes energy savings as the outside air temperature fluctuates. SPLIT LOOP THERMOSYPHON WITH 100% REHEAT CONTROL WRAP-AROUND (ACT-SLT) One valve per row, on/off or modulating, controlled by the Building Management System (BMS) based on the discharge air temperature. ACTIVE THERMAL CONTROL VALVE ACT-TAV TAV controlled by ACT panel and stages can be controlled by BMS. PASSIVE THERMAL CONTROL VALVE (ACT-TPV) Tapered Seal Relief Spring ACT-TPV is available in 5 temperature Partent Pending increments. No control signal is required (passive operation). Return Spring Actuator Body Actuator Guide 7

AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS (AAHX) HOW DOES AN AAHX WORK? Btu /hr Btu /hr Every ACT AAHX is designed to yield the optimal effectiveness in BTU/hr savings. ACT s energy recovery systems are custom engineered for each project to yield the best ratio of cost versus performance. Typical system payback is under two years. SAV ING S SAV ING S Captures space exhaust air energy and transfers via passive heat pipe to pre-cool or pre-heat incoming outside air. AIR-TO-AIR HEAT PIPE HEAT EXCHANGER INSTALLATION OPTIONS The ACT Heat Pipe Heat Exchanger can be oriented to match the AHU or duct work. FLAT SPLIT LOOP THERMOSYPHON VERTICAL WWW.1-ACT.COM/HVAC HORIZONTAL 8

AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS (AAHX) BENEFITS Energy Savings Pre-cool and pre-heat with up to 75% effectiveness During summer operation with 75 exhaust air, the AAHX can pre-cool entering 95 outside air down to 80, saving on cooling load capacity During winter operation with 70 exhaust air, the AAHX can pre-heat entering 0 outside air up to 52, saving on heating load capacity Passive System No maintenance No moving parts Configuration Any height or length (not round) Splittable Exhaust and supply can be different lengths and CFMs From 2 to 15 in depth, requiring minimal AHU space No cross air contamination FEATURES 1/2 Rifled Copper Tubes for Enhanced Thermal Performance Aluminum Fins (8-14 Fpi) Galvanized Steal Casing Factory Installation, Field Installation or AHU Manufacturer Installation R-134a Up to 10 Rows OPTIONS Up to 1 Coil Tubes (Copper or Aluminum) Stainless Steal Casing Multiple Fin Types & Materials Controllable Coil Coating (E-Coat or Heresite) Tilt Option Pump Systems R-410A 9

TILT AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS CONTROL HEAT PIPE AAHX FUNCTION BY TILTING Tilting the HP-AAHX will transfer operation from summer to winter by assuring the warm air stream is lower than the cold air stream. Features included: Steel housing, integrated flex duct, dual contacts, heavy duty actuator, and simple AHU installation. EXHAUST AIR AAHX OUTSIDE AIR PUMPED AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS ENERGY RECOVERY - PUMPED SYSTEM Summer/Winter Energy Recovery (pumps operate for one or both seasons) System can be split between ducts up to 30 + Low Pressure Drop Sizes up to 25,000 CFM+ Positive Recovery Efficiency Ratio (RER) Low RPM pump configuration for long life WWW.1-ACT.COM/HVAC 10

ONLINE SELECTION TOOLS The WAHX and AAHX Selection Tools are intended to provide the designer with the capability to perform a preliminary design selection and to evaluate performance at various design conditions. It is also intended to be a tool to communicate engineering requirements and design targets to ACT for additional calculations and/or for preparing a quotation. The WAHX Selection Tool can be set to English or Metric units. Multiple input variables can be selected from CFM s to DB/WB combinations for incoming Air, Active Coil and Supply Air to mention a few. There are two useful output options for each Selection Tool. One is Print to PDF, which will capture the on screen data in a savable format. The other is a Submit to ACT which will capture the screen data, including the product information that the user enters, and sends it to an ACT engineer for further assistance or quotation. WAHX SELECTION TOOL www.1-act.com/hvac/wahx AAHX SELECTION TOOL www.1-act.com/hvac/aahx 11

WAHX TRADITIONAL DIMENSIONS OAH D ACT WRAP-AROUND HEAT PIPE HEAT EXCHANGER DIMENSIONS W Note: Drawings are not to scale Front View Dimension Table OAH: Total Height Optional OAL: Total Length Optional OAW: Total Coil Spacing Optional GAP Optional GAP OAW FH: Fin Height FL: Fin Length Fin Height MUST be in multiples of 1.25 Optional Energy Recovery Coil Side View E1 E2 E1 - E2: Side Flange E3 - E4: Top - Bottom Flange D: Return Tube Depth W: Coil Width Minimum of 1.5 Minimum of 1.0 See table for minimum See table for minimum E3 (D) Return Tube Depth Table by Number of Rows Rows 1 2 3 4 5 6 7 8 9 10 D 2.0 2.0 2.75 2.75 3.5 3.5 4.25 4.25 5.0 5.0 FH (W) Coil Width Table by Number of Rows Rows 1 2 3 4 5 6 7 8 9 10 E4 W 1.5 3.0 4.0 5.0 6.0 7.0 8.0 9.25 10.5 11.5 FL WWW.1-ACT.COM/HVAC 12

WAHX SPLIT LOOP THERMOSYPHON DIMENSIONS ACT SPLIT LOOP THERMOSYPHON WRAP-AROUND HEAT PIPE HEAT EXCHANGER DIMENSIONS W OAL Front View Dimension Table OAH: Total Height FH + 8.50 OAL: Total Length Optional OAW: Total Coil Spacing Optional D GAP Optional OAH FH: Fin Height,*Max. 36.0 Optional Note: Drawings are not to scale GAP OAW FL: Fin Length E1 - E2: Side Flange E3 - Bottom Flange MUST be in multiples of 1.25 Minimum of 1.00 Minimum of 4.50 E4: Bottom Flange Minimum of 4.00 CASING Energy Recovery Coil Side View D W: Coil Width D: Return Tube Depth See table for minimum See table for minimum E3 * Note: Fin Height over 36.0 must be stacked (D) Return Tube Depth Table by Number of Rows FH OAH Rows 1 2 3 4 5 6 7 8 9 10 No Control - D 2.0 4.0 5.0 7.0 8.0 9.0 10.0 11.0 12.0 14.0 With Control - D 4.0 5.50 6.75 9.0 11.25 13.5 15.75 18.0 20.25 22.5 E4 FL E1 E2 OAL (W) Coil Width Table by Number of Rows Rows 1 2 3 4 5 6 7 8 9 10 W 2.0 3.5 4.5 6.0 7.0 8.0 9.0 10.0 11.0 12.0 WWW.1-ACT.COM/HVAC 13

AAHX ACT-HP-AAHX TRADITIONAL SERIES DIMENSIONS E1 ACT AIR-TO-AIR HEAT PIPE HEAT EXCHANGER DIMENSIONS Front View E2 C E3 Front View Dimension Table Fin Height MUST be in multiples of 1.25 FH: Fin Height Optional FL1: Fin Length FH E4 OAH Optional Ttypically 2.0 or as specified Minimum of 1.5 Minimum of 1.0 FL2: Fin Length C: Center Divider Width E1 - E2: Side Flange E3 - E4: Top - Bottom Flange FL1 FL2 Note: Drawings are not to scale Side View 2-4 - 6 Row Heat Pipe Heat Exchangers FW FW FW Side View Dimension Table by Number of Rows Rows 1 2 3 4 5 6 7 8 9 10 W 1.5 3.0 4.0 5.0 6.0 7.0 8.0 9.25 10.5 11.5 FW 1.08 2.17 3.25 4.33 5.42 6.49 7.58 8.66 9.75 10.83 W W W 2 ROW 4 ROW 6 ROW WWW.1-ACT.COM/HVAC 14

AAHX SPLIT LOOP THERMOSYPHON DIMENSIONS FH 1 E1 ACT SPLIT LOOP THERMOSYPHON AIR-TO-AIR HEAT PIPE HEAT EXCHANGER DIMENSIONS Front View E2 E3 E4 C E5 OAH FH 2 Front View Dimension Table Fin Height Optional Fin Length Optional be in multiples of 1.25 Fin Length Optional be in multiples of 1.25 Typically >4.00 or as specified Minimum of 1.00 FH 1 & 2: Fin Height Maximum Must Stack AAHX over 37.5 FL1: Fin Length FL2: Fin Length C: Center Divider Width E1, E2, E3, E4: Side Flanges FL1 FL2 E6 Minimum of 4.50 Minimum of 4.00 E5 - Top Flange E6 - Bottom Flange * Note: AAHX-Split Loop Thermosyphon Systems can not exceed 36.0 in fin height. Units can be stacked Side View Examples of 2-4 - 6 Row Heat Pipe Heat Exchangers Note: Drawings are not to scale FW FW FW Side View Dimension Table by Number of Rows Rows 1 2 3 4 5 6 7 8 9 10 W 2.00 3.50 4.50 6.00 7.00 8.00 9.00 10.0 11.0 12.0 FW 1.08 2.17 3.25 4.33 5.42 6.49 7.58 8.66 9.75 10.83 W W W 2 ROW 4 ROW 6 ROW 15

ADVANCED COOLING TECHNOLOGIES 1046 New Holland Avenue Lancaster, PA 17601, USA Phone: 717.295.6061 Fax: 717.295.6064 ISO 9001 & AS9100 Certified ITAR Registered www.1-act.com/hvac