Oil Leak Detector NAR300 System High Temperature

Similar documents
Oil Leak Detector NAR300 System

Analog Transmitter AT1000 AT1

Functional Safety Manual Oil Leak Detector NAR300 System

Tank Gauge Transmitter AT-5000

Dust Concentration Meter

OilSET-1000 (12 VDC)

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Proservo NMS5- / NMS7-

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Hi Level/Oil

SET-2000 Oil/Sludge 12 VDC

Ultrasonic Level Measurement nivopuls FDU 10 S

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

SET Installation and Operating Instructions. Level switch for one sensor

Sitron s CF Line of Flow Switch Monitors

Ultrasonic Point Level Switches

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

DB5 Intrinsically Safe Sounder Type DB-5

OIL FILM DETECTOR (Long-distance correspondence Version)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Operating Instructions. For. Alarm Control Module. Model SSR 500

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

General Specifications

Ultrasonic Switches. Features & Benefits

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

for relative humidity and temperature

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

General Specifications

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Rotameter series 250 metal tube variable area flowmeter

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

Safety vacuum drying oven for flammable solvents

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Alarm system For oil-water separator

Level gauges Series LS Level indicator, switch and transmitter for liquids

HYGROPHIL H process hygrometer

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

2500 Automatic Tank Gauge

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Enraf Servo Gauge 854 XTG

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

MICROSENSE FLOW SWITCH

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Technical Data. General specifications. Rated operating distance s n 5 mm

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

INTRODUCTION / TABLE OF CONTENTS

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Dissolved Oxygen Measurement liquisys M COM 223 / 253

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

MBCE-110/230FR Flame Sensor Module

Duct and Rough Service Carbon Monoxide Sensor

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Dräger Polytron 5700 IR Detection of flammable gases and vapours

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Fieldbus Foundation TM Bus diagnostics and troubleshooting

Hygro/hygrothermal transducers (hygrometric)

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Software Version 2.01 LEVEL MONITOR MODEL 220

for relative humidity and temperature

OPTISENS TUR 2000 Technical Datasheet

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Micro/Ultra Filtration System StamoClean CAT 430

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

Dräger Polytron 8720 IR Detection of carbon dioxide

General Specifications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

MBCE-110/230FR Flame Sensor Module

Dräger Polytron 5720 IR Toxic Gas Detection

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Mobrey MCU900 Series Universal Control Unit

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

U L T R A S O N I C G A S L E A K D E T E C T O R

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

High Pressure Conductivity Monitor

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

PARTICULATE EMISSION MONITORING

JW SERIES. Three Phase Thyristor Regulator PSE-351

IECEx Certificate of Conformity

Transcription:

Technical Information Oil Leak Detector NAR300 System High Temperature Application This system is set up in a pit, dike or plant, or sump pit near the pump yard, where it provides the ultimate leak detection function for petrochemicals or vegetable oils. The Oil Leak Detector NAR300 System for high temperature utilizes conductivity detection principle to monitor the condition. This NAR300 system for high temperature is suitable for a pit using steam draining conduit for antifreezing and high temperatures ( 100 C). The accurate and minimal equipment configuration ensures safe operation of the tank yard. Features and benefits Conductive sensor detects presence of conductive liquid No moving parts, low maintenance, long life Safe operation assured via advanced diagnostics that power fail, frozen pit-liquid, etc. Independent of dielectric constant when detecting water-insoluble oils Improved performance even in harsh pit conditions Intrinsically float sensor EMC-compliant Flame proof System: Alarm output transmitted to Host controller via connected Transmitter NRR261 (outdoor installation) and e.g. level transmitter with switching input Intrinsically safe System: Direct alarm output to host controller when connected in combination with Transmitter NRR262 (indoor installation). TI00457G/08/EN/02.12 71188294 Varid as of Software Ver:1.40

Table of Contents Function and system design..........................3 IS system:ex ia IIB T4................................ 3 Ex d[ia]system: Ex d[ia]iib T4........................... 3 Operating Principle................................4 Detection Principle................................... 4 Alarm principle..................................... 5 Operating conditions...............................7 Detection Sensitivity................................. 7 Water-filled pits..................................... 7 Gasolin application................................... 7 Installation.......................................8 Dimensions......................................9 Float sensor NAR300................................. 9 Ex d [ia] Transmitter NRR261.......................... 10 Ex ia Transmitter NRR262............................ 10 Ex ia Sensor I/F Ex box.............................. 11 Electrical connection..............................12 Grounding cable.................................... 12 Ex ia transmitter NRR262-2x.......................... 13 Ex d[ia] transmitter NRR261-3xx....................... 14 Connection diagram................................. 15 Specifications....................................18 Float sensor NAR300................................18 Sensor I/F Ex box...................................18 Transmitter NRR261.................................18 Transmitter NRR262.................................19 Process Conditions................................20 Float sensor NAR300................................20 Sonsor I/F Ex box...................................20 Transmitter NRR261.................................20 Transmitter NRR262.................................21 Accessory.......................................22 Float guide........................................22 U bolt and cable gland................................22 Certificates and approvals..........................23 Ex approval........................................23 Documentation...................................23 Operating Instructions................................23 Safety Instructions...................................23 Ordering Information..............................16 Float Sensor NAR300................................ 16 Transmitter NRR261................................ 17 Transmitter NRR262................................ 17 Endress+Hauser 2

Function and system design IS system: Ex ia IIB T4 The intrinsically safe system includes the intrinsically safe transmitter NRR262, which is installed indoors in a non-ex area, and outputs a signal to an alarm panel or host system located indoors. The signal from NAR300 is output to the transmitter NRR262 via the sensor interface Ex box by a special cable supplied as part of the sensor by Endress+Hauser. EX Hazardous area EX Non-hazardous area Float sensor NAR300-16xxxx Sensor I/F Ex box (Ex ia) Transmitter NRR262-2x (Ex ia) Power supply : AC or DC Alarm output: Annunciator, Upper instrument receiver Ex ia exclusive cable use : 6 to 30m Ex ia common shielded cable use TIIS approval: TC18324 TIIS approval: TC18326 Ex d[ia]system: Ex d[ia]iib T4 From oil leak detection to alarm output, the Ex d[ia] oil leak detection system can monitor the entire process outdoor Ex areas. The circuitry is intrinsically safe from the NAR300 float sensor to the input Exd [ia] side of NRR261 Exd [ia] transmitter. The NRR261 output (Ex d) side can be connected to a tank yard junction box or alternatively to level transmitter relay inputs. This configuration allows signal transmission from the float sensor to the transmitter over ranges up to maximum 2.6 Kilometers. EX Hazardous area Float sensor NAR300 16xxxx Transmitter NRR261-3xx (Ex d[ia]) Sensor I/F Ex box (Ex ia) Alarm output: Junction box (Ex d construction) Level transmitter etc. Power supply: AC or DC Ex ia exclusive cable use : 6 to 30m TIIS:TC18324 TIIS: TC18325 Endress+Hauser 3

Operating Principle Detection Principle Sensing element Conductive sensor detects presence of conductive liquid Conductivity Detect conductive material:water Detect non-conductive material:air or Oil Steam draining conduit Float body metallic Measuring Conductive (water)/non-conductive (air, oil) existing between electrode and float body sensor Oil Water Conductive sensor detect non-conductive existence(oil) ON Alarm Conductivity Water OFF Oil ON Detection in water-filled pit 1. Conductive sensor continuously monitors conductivity between probe and float body. 2. When water is detected by the conductive sensor, it is considered the normal condition. 3. When an oil layer forms on the water the conductivity between probe and float body decreases, and conductive probe alarm status turns to ON. 4 Endress+Hauser

Alarm principle 1 Ex [ia] type transmitter system Hazardous area Non-hazardous area Float sensor NAR300 NAR300-16xxxx Ex [ia] exclusive cable Conductive sensing electrode+ Conductive sensing electrode- (float) Sensor I/F Ex box Conductive sensing circuit Current output circuit 8mA, 16mA current signal Safety barrier NRR262 transmitter Power circuit Alarm output operating table Relay Delay circuit Current sensing Trimmer for delay adjustment Alarm 2 Ex d[ia] type transmitter system Hazardous area Non-hazardous area Float sensor NAR300 NAR300-16xxxx Ex [ia] exclusive cable Conductive sensing electrode+ Conductive sensing electrode- (float) Sensor I/F Ex box Conductive sensing circuit Current output circuit 8mA, 16mA current signal Safety barrier NRR261 transmitter (NRR261-3xx) Power circuit Relay Delay circuit Current sensing Ex d circuit Trimmer for delay adjustment Alarm Principle of Alarm operation The oil leak detection signal generated at the float sensor NAR300 is converted to 8mA (alarm OFF) or 16mA (alarm ON) by the current output circuit at the transmitter or Sensor I/F Ex box. It is further connected to the current detection circuit thru an IS safety barrier.in the current detection circuit, the existence/absence of oil leak alarm signal is judged according to the current value, sent through a delay circuit and turns the alarm output relay ON or OFF. The alarm delay circuit is configurable from 1-30 seconds (additional 6 seconds is added as the base delay value).fail-safe performance of the relay output is also available (see below). Alarm output operating table (see page13-14) Condition Oil leak alarm Power OFF Liquid freezing Non-alarm Terminals NRR262 N.C. to COM NRR261 N.C. to COM terminal :11,13 Contact Close Contact Close Contact Close Contact Open NRR262 N.O. to COM NRR261 N.O. to COM terminal:13,15 Contact Open Contact Open Empty pit Contact Close Contact Open Contact Open Contact Close The ON delay time is adjustable via delay trimmer. After turning off power to transmitter NRR261, remove the electronics compartment cover to see the trimmer. On NRR262 the trimmer is located on the surface of the case. It is possible to set the delay from 1-30 seconds. When an alarm condition continues longer than the delay time setting it is judged as an alarm output. If the alarm condition stops within the delay time setting, an alarm is not output, thus preventing false alarms. Note! A delay time of approx. 6 sec. is automatically added. Endress+Hauser 5

NRR261 transmitter NRR262 transmitter Trimmer for delay adjustment Cover LED Power (green)/alarm(red) Trimmer for delay adjustment 6 Endress+Hauser

Operating conditions Detection Sensitivity Depending on actual condition, watar may sometimes cling to the electrode, even though the sensor is floating on oil above the water. In such case, oil detection sensitivity may be affected by 1 to 2 mm. When absolute precision is required we recommend coating the electrode with a mild detergent in order to keep water from clinging to the electrode. Water-filled pits Not for use in salt -water pits The Float Sensor NAR300 is not designed for use in salt-water. If used in salt-water the following abnormal performance may occur: Output an alarm wrongly if overturned by waves Salt content may create a short between float sensor and probe, causing alarm delay Failure due to salt-water corrosion Pits with liquids other than water When using the float sensor on particular liquids such as a solvent blend, it may be corroded and damaged. High electrical resistance water in pit When using the float sensor on high electrical resistance water such as pure water, an alarm may ring. Eelectric conductivity should be 10 S/cm ( 100k? cm). As an example: Pure water is 1 to 0.1S/cm (1 to 10M cm) The water freezing in a pit When water in the pit freezes, the alarm may ring (fail safe function). Please implement anfreeze prevention measures. Gasolin application For gasolin application, please choose NAR300 with technically special product by contacting your Endress+Hauser representative. Endress+Hauser 7

NRR262 Oil Leak Detector NAR300 System High Temperature Installation Float sensor NAR300 + Transmitter NRR26x EX Hazardous area Non-Hazardous area EX *10 Sensor I/F Ex box Ex ia transmitter NRR262 Tank U Bolt JIS F3022 B50 Alarm output Dike JB. Ground wire Pit cover *1 Fence *8 Discharge nozzle *7 Chain *4 Special Cable Valve Ground wire *10 Ex d [ia] Transmitter NRR261 U-shaped Class A ground drainageway Non-Hazard area EX Screen *3 Float guide *2 Min. 100mm Cable *6 Drain *5 Note! when grounding the barrier, connect with tank or use the shielded wire for remote cable. When using the shielded wire for remote cable, refer to Electrical connection. Pit *9 Weight Float sensor NAR300 Notes regarding installation and mounting 1. Take precautions to prevent rubbish or snow from entering the pit, e.g. rubbish guard, roof, cover etc. If snow accumulates on the float sensor NAR300, it will sinks at 1mm per 50g of snow into the water and reduce oil detection sensitivity. Mount covers higher than the top of the pit to avoid submerging the Float Sensor NAR300 during heavy rains. If the float sensor is submerged it may not perform as intended. 2. The Float Sensor NAR300 may not perform as intended if it becomes unbalanced by more than about 3 degrees horizontally. Use float guides as recommended to keep balance, and take care that chains and cables are not tangled in the float or guides. 3. We recommend mounting a screen at the water inlet to prevent rubbish from entering the pit. Conduct periodical inspections/cleaning to maintain optimal performance of the system. 4. It may be convenient to attach a lifting chain to the float sensor head for inspection. Please consider that the sensivity decreases at 1mm per 50g. Do not use excessive force when pulling the chain. 5. When the pit becomes completely filled with water, even if an oil leak occurs, an oil layer cannot form on the surface of the water due to overflowing from the pit. Please drain water appropriately. 6. Do not pull the sensor by its signal cable. Pulling the signal cable may damage the sensor. 7. When the drain valve is kept continuously open, it should be formed such that it curves downward at least 100mm. Failure to do so may cause any oil to discharge from the pit before it can form a detectable layer on the water surface, resulting in a delayed alarm condition or failure to detect. In the case of a pit without discharge nozzle as illustrated above, install water-fence or other mechanism such that oil will form detectable layer on the water surface. 8. If necessary, set up a fence to prevent extreme waves, crosscurrents, or water splashing onto the float sensor. 9. If the pit is too wide, it may not allow a detectable oil layer to form on the water surface. In this case install a divider to reduce the surface area such that a detectable oil layer will form. 10. Mount the NAR300, NRR261 and I/F Ex box at least 50 cm apart. 8 Endress+Hauser

Float sensor NAR300 Dimensions 10 Float sensor cover 200 250 210±10 73 Ф304±4 Float guide Note! If the float sensor cover is broken or missing, detection sensitivity may decrease. Replace the broken cover with authorized spare parts from Endress+Hauser. If the float sensor NAR300 is used in a pit that contains a liquid/substance that is corrosive to the float sensor material, it should only be used during an actual oil leak. In case of continued use after an oil leak, carry out inspections. Take precautions to prevent steam from directly flowing onto the Float Sensor NAR300. Do not try to disassemble or adjust the float sensor electrical components. Such actions may cause damage or failure to the sensor. 200 10 M10 nut Float guide 10 L Weight 280 200 350 Endress+Hauser 9

Ex d [ia] Transmitter NRR261 NRR261-**B (NPT3/4) NRR261-**D (M25) 296 (NRR261-**A or E (G3/4),K(G1/2) (195) Ex d Terminal (120) 279 205 20 74 Ex ia Terminal Special U Bolt, JIS F3022 B50 Material: Iron (chromate filming) with 2 Nuts and 2 Flat washers 347 269 150 105 43 4 - Ø 12 (114 ) Ex ia Transmitter NRR262 M4 40 20 13 NRR262 DIN rail:en50022 compliant 119 110 97 M4 screw (not supplied) Delay trimmer 4.5 25 38 M3 129 5 78 10 Endress+Hauser

Ex ia Sensor I/F Ex box G1/2:85 75 (113.7) 222.2 61. 2 165. 2 Special U Bolt, JIS F3022 B50 Matetial: Carbon steel (chromate filming) with Nut and Flat washer Note! Sensor I/F Ex box is included in the order code of NAR300-16xxxx. This device is used in combination with NRR262-2x (Ex ia) or NRR261-3xx (Ex d [ia]). Endress+Hauser 11

Electrical connection When using float sensor NAR300 Ex ia together with transmitter NRR261 Ex d[ia], it is necessary to ground the NRR 261 to a safety per barrier the following procedure. Note! The grounding cable for safety barrier should be connected independent of any other devices which do not have safety barriers (e.g. arresters), according to Class A grounding standards. Use a conductive grounding wire with cross-sectional dimensions at least 2 mm 2. In an instrumentation room, a field device with Class A ground may be connected in common with the communication cable shield. "Class A ground" general description Ground resistance value Grounding cable Tensile strength : more 1.04kN and Metallic wire or copper wire (more 2.6 mm in diameter) 10Ω Grounding cable Tank Transmitter NRR261-3xx Cable for Ex d Ex d terminal Power Alarm Ex ia terminal grounding cable EX Non-Hazardous area Class A ground Float sensor NAR300 Underground 12 Endress+Hauser

NRR262 Oil Leak Detector NAR300 System High Temperature Ex ia transmitter NRR262-2x EX Hazardous area EX Non-Hazardous area Float sensor (NAR300-16xxxx) Sensor I/F Ex box Ex ia transmitter NRR262-2x Ex ia line Special Cable for Ex ia connection: 6 to 30m Ground for Ex ia at the non-hazardous area ( Class A ground ) Power Alarm Ground for Ex ia at the non-hazardous area ( Class A ground ) Ex ia transmitter NRR262 + - GND NRR262 Input from the Sensor I/F Ex box * 1), * 2)AC90-250V 50/60Hz L N FG Alarm output N.C COM Monitor output for check N.O + - *1) When the power spec. is DC22 to 26V, terminal No. L is + and No. N is -. *2) To maintain IS capability, do not exceed AC 250V 50/60Hz, DC 250 V. Sensor I/F Ex box Green Output to the NRR 262-2x FG H- TB1 H+ FEL+ FEL- TB2 FRAME GUARD PROBE Yellow Black White FEL+/FEL- is not to make connection. Endress+Hauser 13

Ex d[ia] transmitter NRR261-3xx Float sensor (NAR300-16xxxx) EX Hazardous area EX Non-Hazardous area Special Cable for Ex ia connection: 6 to 30m Transmitter(NRR261-3xx) Ex d cable line Power Alarm Ex d terminal Ex ia cable line *1) If the power spec. is DC22 to 26V, terminal No. 1 is + and No. 5 is -. *2) Wire by selecting Ex d side or Ex ia side. *3) Connect if AC cable with FG is used *4) To maintain IS capability, do not exceed AC 250V 50/60Hz, DC 250 V * Blue1,Blue2,Blue3,Yellow-Green cables wired when shipping Ex d terminal Ex ia terminal *2) Ground at the Power arrester (mounted) non-hazardous area ( Class A ground ) 1 3 5 7 9 L GND N L 1 2 4 6 8 10 SRA SRA SRA GND1 N1 *3 FG N.C COM *1) *4)AC90 250V N.O 50/60Hz 11 13 15 17 19 Ex ia terminal N.C 12 COM 14 N.O 16 N.C1 COM1 N.O1 Yellow-green: FG arrester GND 18 20 Blue 1 Blue 2 Blue 3 1 2 connecting terminal for Class A ground FG:connecting terminal for Class A ground H+ H- PG Sensor I/F Ex box Green output to NRR261-3xx FG H- H+ TB1 TB2 FEL+ FEL- FRAME GUARD PROBE Yellow Black White FEL+/FEL- is not to make connection. 14 Endress+Hauser

Connection diagram Hazardous area EX Float sensor Sensor I/F Ex box TransmitterNRR261-3xx (extended range) Ex ia Ex ia Barrier Circuit General equipment Non-Hazardous area This grounding cable is allowed to share with the other safety barrier ground, but is not allowed to share with the arrestor grounding cable Class A ground Endress+Hauser 15

Ordering Information Float Sensor NAR300 010 Approval: 1 Ex ia IIB T4, TIIS 9 Special version, TSP-no. to be spec. 020 Type: 1 Float 2 Float, module set (Econounce NRR261 upgrade) 4 Float, Ex box (Econounce NRR262 upgrade) 5 Float, Ex box (separate type) 6 Float, high temperature, Ex box (separate type) 9 Special version, TSP-no. to be spec. 030 Output: A 2-wire current Y Special version, TSP-no. to be spec. 040 Signal Cable: A 6 m B 10 m C 15 m D 20 m E 25 m F 30 m Y Special version, TSP-no. to be spec. 050 Float Guide: 1 Not used 2 Guide 304, weight SS400 3 Guide 304, weight 304 9 Special version, TSP-no. to be spec. 060 Cable Entry: A Not needed B G1/2 C NPT 1/2 E M25 Y Special version, TSP-no. to be spec. NAR300- Complete product designation 16 Endress+Hauser

Transmitter NRR261 010 Approval: 2 Ex d[ia] IIB T4, TIIS (NAR300) 3 TIIS, Ex d[ia] IIB T4 (NAR300 separate type) 9 Special version, TSP-no. to be spec. 020 Power Supply: A 90-250VAC 50/60Hz B 22-26VDC Y Special version, TSP-no. to be spec. 030 Cable Entry: A G 3/4 x 2 (Ex d) B NPT3/4 x 2 (Ex d) D M25 x 2 (Ex d) E G3/4 x 2 (Ex d), G1/2 x 1 (Ex ia) K G1/2 x 2 (Ex d), G1/2 x 1 (Ex ia) Y Special version, TSP-no. to be spec. NRR261- Complete product designation Transmitter NRR262 010 Approval: 2 Ex ia IIB T4, TIIS (NAR 300) 9 Special version, TSP-no. to be spec. 020 Power Supply: A 90-250VAC 50/60Hz B 22-26VDC Y Special version, TSP-no. to be spec. NRR262- Complete product designation Endress+Hauser 17

Specifications Float sensor NAR300 Protection class Power Supply Wetted material Detection sensitivity *1 I/O cable Weight IP67 (for outdoor installation) by transmitter Float : SUS316L Conductive sensor: SUS316, PTFE Water-filled pit: 10 +/- 1mm, alarm setting before delivery with kerosene Exclusive FKM shield cable, including cable float (6m standard) Approx. 2.5kg (including 6m (FKM) cable). *1: Kerosene (relative density approx. 0.8 g/cm 3 ), on water (relative density approx. 1.0 g/cm 3 ), static level condition, no surface tension Sensor I/F Ex box Protection class IP67 (for outside installation ) Power Supply output signal Cable entry Weight by NRR261 or NRR262(with an arrester) Approx. 7 to 16mA NAR300 (Float sensor): G1/2 with a cable gland x1 NRR261 or NRR262 (Transmitter): G1/2 thread x1 Approx. 3.2kg Transmitter NRR261 Protection class IP67 (for outside installation ) Power Supply 90 to 250VAC, 50/60Hz 22 to 26VDC (with an arrester) Power consumption Input Output 20VA/2W Approx. 7 to 16mA from NAR300 / Sensor I/F Ex box Contact output :1SPDT contact rate : 250VAC, 1A, 100VA, 100VDC : 1A, 25W Delay setting: 1 to 30 sec. by the delay trimmer (add 6 sec. as base delay) Failsafe function: available if power fail, frozen sensor (see alarm output table on page 5) Cable entry Arrester Weight Ex d side: G 3/4 x 2, TIIS Ex specified cable glands model SXBM Exi side: G 1/2 x 1, with cable gland Built-into power supply Approx. 10 kg 18 Endress+Hauser

Transmitter NRR262 Protection class IP20 (for inside installation ) Power Supply 90 to 250VAC, 50/60Hz 22 to 26VDC Power consumption Input Output 20VA/2W Approx. 7 to 16mA from NAR300 / Sensor I/F Ex box Contact output :1SPDT contact rate : 250VAC, 1A, 100VA, 100VDC, 1A, 25W Delay setting: 1 to 30 seconds by the delay trimmer (add 6 seconds as base delay) Failsafe function: available if power fail, frozen sensor (see "alarm output table" on page 5) Arrester Weight Built-into power supply Approx. 0.6 kg Endress+Hauser 19

Process Conditions Float sensor NAR300 Detective object Relative density greater than 0.7 g/cm 3 and less than 1.0 g/cm 3. When relative density is greater than 0.9 g/cm 3, dynamic viscosity must be greater than 1mPa s. Water is approximately 1 mpa s. Not soluble in water Non-conductivity Flowing Operating temperature Water in pit Ambient : -20 to +100 C (- 4 to +212 F) Mearsuring liquid : 0 to +100 C (+32 to +212 F) Relative density greater than 1.0 g/cm 3 and less than1.13 g/cm 3. (when kinematic viscosity equals 1mm 2 /sec) * 2 Not frozen Conductivity is greater than 10 µs/cm and less than 100k Ω cm. (greater than 1 µs/cm if float sensor is normally floating on the water). Not salt-water Other Clean off any debris that sticks to the sensor. Do not let mud cake on the float sensor. Avoid pit conditions that cause the float sensor to tilt off-balance or change the draft-line. Install measures to avoid cross-currents, standing waves. *2 pre-delivery setting is done with kerosene on water; therefore sensitivity may differ if the lower liquid is diluted with e.g. antifreeze. Sonsor I/F Ex box Connecting cable Maximum inductance 3mH, maximum capacitance 83nF e.g. KPEV (instrumentation cable) C=65nF/km, L=0.65mH/km CW/C=0.083μF/65nF=1.276km [1] LW/L=3mH/0.65mH=4.615km [2] Maximum cable length = 1.27km * The smaller of [1] or [2] is the maximum usable cable length. (Fractions are truncated) Operating temperature Ambient : -20 to +60 C (- 4 to +140 F) Transmitter NRR261 Connecting cable Maximum inductance 3mH, maximum capacitance 83nF e.g. KPEV (instrumentation cable) C=65nF/km, L=0.65mH/km CW/C=0.083μF/65nF=1.276km [1] LW/L=3mH/0.65mH=4.615km [2] Maximum cable length = 1.27km * The smaller of [1] or [2] is the maximum usable cable length. (Fractions are truncated) Operating temperature Ambient : -20 to +60 C (- 4 to +140 F) 20 Endress+Hauser

Transmitter NRR262 Connecting cable Maximum inductance 3mH, maximum capacitance 83nF e.g. KPEV (instrumentation cable) C=65nF/km, L=0.65mH/km CW/C=0.083μF/65nF=1.276km [1] LW/L=3mH/0.65mH=4.615km [2] Maximum cable length = 1.27km * The smaller of [1] or [2] is the maximum usable cable length. (Fractions are truncated) Operating temperature Ambient : -20 to +60 C (- 4 to +140 F) Endress+Hauser 21

Accessory Float guide Note! When mounting the float guide weight, set it up horizontally. Remove trash and stones on the pit bottom before mounting the Float Sensor. The length of float guide is 2m (standard), but if you need anything else, please order as special version. L 10 200 M10 nut Float guide Name Float guide Weight Delivery quantity 2 1 Material SUS304 SS400 SUS304 M10 nut 6 SUS304 10 Weight 280 200 350 U bolt and cable gland U bolt (JIS F3022 B50) is used for mounting the transmitter. Please prepare a pipe of nominal 50A (2B Ø60.5 mm). Tighten and fix the cable gland after insert a cable from the float sensor NAR 300. U bolt (JIS F3022 B50) Name Mounting U bolt Accessory : nut : Washer Delivery quantity 2 4 4 Material Carbon steel (chromate) Cable gland 1 Nylon Cable gland 22 Endress+Hauser

Certificates and approvals Ex approval TIIS Ex ia IIB T4 (Float sensor NAR300-16xxxx high temperature separate type) Ex d [ia] IIB T4 (Transmitter NRR261-3xx separate type) Ex ia IIB T4 (NRR262-2x separate type) Documentation Operating Instructions Safety Instructions BA00403G Oil Leak Detector NAR300 System High Temperature XA00587G-A TC18324 (NAR300) XA00588G-A TC18325 (Transmitter) XA00589G-A TC18326 (Transmitter) Endress+Hauser 23

Endress + Hauser Yamanashi Co., Ltd. 862-1 Mitsukunugi Sakaigawa-cho Fuefuki-shi Yamanashi, 406-0846 Japan Phone: ++81 55 266 4964 Fax: ++81 55 266 4969 http://www.endress.com TI00457G/08/EN/02.12 71188294 FM+SGML 8.0