Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Similar documents
Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Autocalibration Systems for In Situ Oxygen Analyzers

Rosemount 3051S Electronic Remote Sensors

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

Net Safety ST3 XChem Toxic Gas Sensor

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

OMA-300 Process Analyzer

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

APPLIED. OMA-406R Rackmount Process Analyzer

Rosemount 3490 Series

Rosemount High Density Temperature Measurement. Simplify Your Project

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Rosemount 2100 Series

Duct Mount. Installation Instructions

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

High Pressure Conductivity Monitor

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 1500XA Process Gas Chromatograph

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

CERTIFICATE of Product Conformity (QAL1)

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 3051S MultiVariable Transmitter

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection

HFID Heated Total Hydrocarbon Analyzer Module

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Rosemount 1500XA Process Gas Chromatograph

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 752 Fieldbus Remote Indicator

Spectron LSN (Life Safety Network) Suggested Specifications

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Configuration Data Sheet

Rosemount 4500 Hygienic Pressure Transmitter. Start

Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Industrial Grade Gas Detection

Rosemount 1595 Conditioning Orifice Plate

Model 144H. Product Data Sheet , Rev DB February Content

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Low Temperature Zirconia Oxygen Analyzer

Dependable Solutions for Gas Detection

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Model D12-IR. Digital Gas Transmitter...

Zircomat Oxygen Analyzers

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Semi flush-mount room thermostats

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Controllers, Indicators & Set Point Programmers

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Rosemount 3100 Series Ultrasonic Level Transmitters

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Process Gas Chromatograph

PURSense Sanitary Flange Conductivity Sensors

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Dräger Polytron 8100 EC Detection of toxic gases and vapors

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 2090F Hygienic Pressure Transmitter

Process Gas Chromatograph

I/A Series 716C 1/16 DIN Temperature Controller

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Toxic Gas Detection. Model F12. Toxic Gas Detection

Rosemount 2088 Absolute and Gage Pressure Transmitter

A New Standard of Excellence

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Dräger Polytron 5100 EC Detection of toxic gases and vapors

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Annubar Flowmeter Series

Emerson Plantweb Insight

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger QuadGard Control System

Dräger PointGard 2100 Detection of toxic gases and vapours

Transcription:

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO probes HART communications standard (AMS aware) Wireless - via THUM TM Adaptor Advanced Features Calibration recommended diagnostic Xi enhanced interface Automatic calibration capability Extended process temperature ranges Stoichiometer feature Wireless THUM TM Adaptor Programmable reference Loss-of-flame heater cut-out Rosemount Analytical Xi Advanced Electronics for Zirconium Oxide Oxygen Probes The zirconium oxide sensing technology for measuring the excess oxygen in combustion flue gases has gained prominence over the past several decades. This versatile electronics is specifically designed to run most O probes manufactured. The large backlit LCD display makes it easy to set up and operate. Fully automatic calibrations may be executed from this electronics with the addition of a small solenoid box for switching calibration gases.

The Xi electronics offers the following unique advanced features never before offered for O probes: Automatic Calibration Plant personnel often ask how frequently an oxygen analyzer requires calibration. The answer is very application-dependent based upon the fuels being burned, normal levels of oxygen and the sulfur content in the flue gases. The Xi addresses this concern by providing an on-line diagnostic that determines when a calibration should be conducted, eliminating many unneeded calibrations and the technician and gas resources they consume. The Xi electronics has an on-line impedance measurement for the sensing cell. This feature can trigger a fully automatic calibration by sequencing solenoids to introduce calibration gases to the sensing cell. The Single Probe Sequencer (SPS) switches CAL gases to a single probe, while a Multi-Probe Sequencer (IMPS) can handle 1 to 4 probes. Many needless calibrations based on time in service are eliminated. A contact closure notifies the control room when a calibration is taking place. The oxygen output signal can be held at its last value, or released during calibration. The Xi can also initiate calibrations by traditional methods: Stoichiometer Process upsets can sometimes cause a combustion process to go into substoichiometric or reducing conditions. The oxygen readings from one or more probes may decline all the way to zero. The stoichiometer cell will measure the amount of oxygen deficiency during these reducing conditions. The trends in your DCS can be set up for a lower range limit of -1 or -% oxygen to depict the level of oxygen deficiency. The operator can see if his control actions to recover are having the desired effect. These types of events do not occur frequently, but knowing the parameters of the situation prevents overcorrecting while coming out of the reducing condition. Programmable Reference enhances operation for the following applications: n Moisture Monitoring measuring the amount of moisture coming off of industrial dryers by noting the dilution effect water vapor has on the normal 0.95% ambient drying air. n Enriched Oxygen Combustion Pure oxygen is sometimes mixed in with the combustion air to increase heat at the flame. This is used in steel and other metals reduction processes and also in some catalyst regenerators. n Flame Safety Interlock dry contact from a flame safety system removes power from the probe heater in a loss-of-flame event. Contact closure from the user s control room Time since last calibration feature established by the autocalibration system Xi enhanced interface HART/AMS Extended Process Temperature Range Traditional O electronics will go into alarm if the process temperature exceeds the controlled heater temperature. This feature enables the Xi to turn off the internal heater in this event, use the process temperature to heat the cell, and calculate O on the fly from the changing process temperatures. Note that accelerated probe and cell damage may occur as a result of extended operation above 800 C (146 F), but at least the measurement will not go off-line during this event. www.emerson.com/rosemountgasanalysis

Specifications General Purpose Certifications Xi Ambient Temp.Limits -0 to 55 C (-4 to 131 F) Xi Temp. Limits as measured inside the housing -0 to 55 C (-4 to 113 F) Xi LCD display Temp. Limits -0 to 55 C (-4 to 131 F) Installation Specifications Electrical Power of Oxymitter or optional Xi electronics 10 to 40V, ±10% 50/60 Hz Power Consumption of Xi 10 watts maximum Xi Alarms Relays provided - amps, 30 VDC Xi Optional Loss of Flame Contact Removes heater power Electrical Noise Meets EN 6136, Class A Power 100-40V ±10%, 50-60Hz Power Consumption of Xi 1VA maximum or 776VA maximum with Traditional Architecture, 10V, Probes. 450VA maximum with Traditional Architecture, 44V Probes Alarm Relay Outputs Two provided - Amperes, 30 VDO, Form-C Optional Loss of Flame Input internally power input to remove heater power, actuated via dry contact output from proof-of-flame device Emerson Process Management has satisfied all obligations coming from the European legislation to harmonize the product requirements in Europe. 1 All static performance characteristics are with operating variables constant. Specifications subject to change without notice. www.emerson.com/rosemountgasanalysis 3

Dimensions Xi Enhanced Interface- Panel Mounting Details 4 www.emerson.com/rosemountgasanalysis

Dimensions Xi Enhanced Interface- Wall/Surface and Pipe Mounting Details www.emerson.com/rosemountgasanalysis 5

Ordering information Xi Advanced Electronics Model Xi Type Product Description O Advanced Electronics 01 Single Channel 0 Single Channel with Flame Safety Interlock for Heater 03 Dual Channel 04 Single Channel, Traditional Architecture for 10V Probes 05 Single Channel, Traditional Architecture for 44V Probes Mounting 01 Panel Mount Kit with Gasket 0 Pipe/Wall Mount Kit Cable 10 0 (6m) Cable 11 40 (1m) Cable 1 60 (18m) Cable 13 80 (4m) Cable 14 100 (30m) Cable 15 150 (45m) Cable 16 00 (60m) Cable Stoichiometer Function 1 01 Single Channel 0 Dual Channel (second channel not available for traditional architecture Xi) Programmable Reference Function 1 01 Single Channel 0 Dual Channel, (second channel not available for traditional architecture Xi) Extended Process Temperature (85 )/Heaterless Operation 01 Single Channel 0 Dual Channel, (second channel not available for traditional architecture Xi) Notes: 1 Software feaures may be added in the field after shipment. Wireless THUM TM Adaptor is ordered separately. 6 www.emerson.com/rosemountgasanalysis

Notes www.emerson.com/rosemountgasanalysis 7

www.emerson.com/rosemountgasanalysis Analyticexpert.com Emerson Automation Solutions Rosemount 800 Market Boulevard Chanhassen, MN 55317 United States Phone: 1.800.999.9307 Fax: 1.95.949.7001 Gas.CSC @Emerson.com Twitter.com/Rosemount_News Rosemount Gas Chromatographs & Service Center 1041 West Little York, Suite 00 Houston, Texas 77040 United States Phone: 1.866.4.3683 Fax: 1.713.87.3865 Rosemount Latin America Emerson Process Management Analytical Division 111000 Brittmoore Park Drive Houston, TX 77041 Phone: 1.713.467.6000 Fax 1.713.87.339 Rosemount - Europe Emerson Process Management Services Ltd. Analytical Division Blegistrasse 1 PO Box 1046 CH 6341 Baar Switzerland Phone: 41.41.768.6111 Fax: 41.41.761.8740 Emerson Automation Solutions Distribution Limited P.O. Box 105958 Abu Dhabi UAE Phone: +971 69707 Fax: +971 5550364 Rosemount Asia Pacific Emerson Automation Solutions Analytical Division Asia Pacific Private Ltd. 1 Pandan Crescent Singapore 18461 Republic of Singapore Phone: 65.6.777.811 Fax: 65.6.777.0947 017 Emerson Automation Solutions. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.