PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Similar documents
T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

AIR CURTAIN HX RECESSED RANGE

AIR CURTAIN T SURFACE MOUNTED RANGE

AIR CURTAIN COMPACT 2 SURFACE MOUNTED RANGE

AIR CURTAIN HX RECESSED RANGE

AIR CURTAIN PHV SURFACE MOUNTED RANGE

Recessed. Air Curtain. Fig 1. Recessed air curtain

VRF HP HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with City Multi (VRF) systems

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

Instruction Manual WARNINGS

HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units

Original instructions AR

SURFACE WARM CEILING HEATERS

INCORPORATION & INSTALLATION INSTRUCTIONS. For incorporating a heat pump control system by others

PHV2000NT CHILLED WATER HEAT PUMP, SENSIBLE/DRY COOLING UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

The CAB & DAB Air Curtains

Manual Comfort Air Curtain

Surface Warm Ceiling Heaters

Recessed Warm Ceiling Heaters

OWNERS INSTRUCTION MANUAL

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

Commercial Fan Heater

AC25. Art.nr:

Installation, operation and Maintenance Manual

Installation Instructions & Operating Manual IMPORTANT

Electric Riva Flame-Effect Cassette Fire

Gallery Electric Fireplaces

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

Please read this sheet as it contains important information

Hand Dryer Installation & User Manual

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

CASSETTE UNIT. Comfort Circle

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Smoke Vent Control Panel PCB4 V4 Installation Manual

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

WYND DC 54 CEILING FAN Installation Manual

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

SUBMERSIBLE DIRTY WATER PUMP

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Original instructions. Panther 6-15 kw

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

The green and friendly entrance. Comfort air curtains Model CA 2

OPERATION & MAINTENANCE INSTRUCTIONS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Sanitary Water Tank INSTALLATION & SVC MANUAL

INSTANTANEOUS ELECTRIC SHOWER

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

5KW ELECTRIC FAN HEATER

Logic+ Combi

RE-PR3-E-27 3-Phase Panel Mount 27kW

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Unvented Electric Water Heater 10/15 litre Undersink

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Safety / Kit Components 1

COLD STORE AIR CURTAIN MAT

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Oceanic Sauna Heater Manual

T-Series Air Conditioner T53 Model

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

ELSTON 52 CEILING FAN

HS&S Alert No: 103 Date: 9 March 2017

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Electrisaver User and Installation Instructions

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

F6102 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

ELECTRIC FLAT PANEL FIREPLACE HEATER

Installation and Operating Manual Drying Cabinet

52 CEILING FAN. Owner s Manual Models #50336, 50337

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

TOUCHDOWN 48 CEILING FAN

INSTALLATION & TECHNICAL MANUAL

WORLDWIDE DISTRIBUTORS

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

LUCCI WHITEHAVEN DC CEILING FAN

KADO LUX LED EXHAUST FAN 200

Installation and Instruction Manual

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

Installation, Operating and Servicing Instructions

Imperial Electric Fires

RF Programmable Room Thermostat Installation Instructions

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Transcription:

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire England CV11 5AU Email: sales@thermoscreens.com Tel: +44 (0) 24 7638 4646 Fax: +44 (0) 24 7638 8578 www.thermoscreens.com 4004175-6 UK Page 1 of 19

UN-PACKING YOUR PHV-RECESSED AIR-CURTAIN The following items are supplied and packaged within the boxes. PHV-Recessed Air Curtain Remote Control Ecopower Electric & LPHW Manual Ambient Motorised Valve (Ecopower LPHW units only) Recessed Grille (Packed separately) Note Optional filters are available for Water and Ambient models. If anything is missing or damaged please contact your place of purchase immediately. For your records Date of Purchase.. Place of Purchase. Serial Number For warranty purposes proof of purchase is necessary so please keep a copy of your invoice. (All documentation supplied with each unit should be stored and kept for future reference). 4004175-6 UK Page 2 of 19

INSTALLATION OF YOUR PHV-RECESSED AIR-CURTAIN The PHV-Recessed air curtain has been designed for recessing within ceiling voids or bulkheads. Location Ensure that the unit is mounted within its height specification of 1.8m to 3.75m maximum (from floor level to the underside of the unit/grille) and that it is situated as close to the door as possible. Note: The air discharge should be nearest to the door as shown in adjacent figure. Ensure the air curtain is as close to the door opening as possible for best performance, obstructions such as door opening devices, structural beams etc will reduce the performance. Note the PHV-Recessed air curtain has a series of square punched air ventilation holes along one side panel of the unit which will be within the ceiling void once the unit is installed. There must be an air gap of 50mm minimum between these ventilation holes and any obstruction/bulkhead within the ceiling void to allow ventilation air to easily enter the air curtain via these holes. Furthermore, the ceiling void must be sufficiently large and freely ventilated so there will be adequate supply of ventilation air (m 3 /hr) to the unit, see Table 1. If the ceiling void is enclosed around the air curtain it will need an air ventilation grille of effective free area (cm 2 ) as given in Table 1 and an adequate air path within the void for air to enter the square punched air ventilation holes. Table 1 Air curtain Required air flow within Effective free area of ventilation grille ceiling void (m 3 /hr) for an enclosed ceiling void (cm 2 ) PHV1000R 353 500 PHV1500R 421 700 PHV2000R 707 1200 Ceiling Suspension For a standard width recess grille (436mm), make the cut-out in the ceiling to the dimensions given in Figure 1. The air curtain needs to be tipped on its side and angled upwards to fit through the ceiling cut-out, ensure there is sufficient height clearance in the ceiling void to do this. For an air curtain with a wider recess grille (476mm), make the cut-out in ceiling to the dimensions given in Figure 2. The air curtain will fit through the ceiling cut-out. Alternatively, the ceiling can be fitted after the air curtain has been installed. Clearance holes for M10 threaded rod to enter from above are provided on the top face of the casing (4 x 1m and 6 x 1.5/2m models, for dimensions see Figure 1 or Figure 2) allowing the unit to be suspended. All six suspension points must be used for 1.5m and 2m models. Insert rod through each hole in top and attach onto each fixing bracket at lower edge of air curtain (see insert). Lock rod in place using M10 nut above and below fixing bracket (threaded rod and locking nuts are not provided). Ensure rod does not come below bottom face of unit. fixing bracket Ensure each of the threaded rods is secured on to a suitable structure that can support the weight of the unit (for unit weights see Table 2)*. 4004175-6 UK Page 3 of 19

436 Figure 1 - Standard Recess Grille CEILING LEVEL 20-90mm 436 C Electrical supply inlets suitable for 25mm gland - 2m electric heating unit only. A B B Electrical supply inlets suitable for 25mm gland (1m & 1.5m) PHV1000R PHV1500R PHV2000R Holes for M10 drop rods A(mm) 1150 1650 2240 B(mm) N/A 800 1095 C(mm) 1104 1604 2190 55 314 140 296 Cut-Out Length(mm) 1055 1555 2145 in Ceiling Width(mm) 390 390 390 LPHW connections Rp 3/4 (3/4in.BSP female) 4004175-6 UK Page 4 of 19

436 Figure 2 - Wider Recess Grille Electrical supply inlets suitable for 25mm gland - 2m electric heating unit only. A B B Electrical supply inlets suitable for 25mm gland (1m & 1.5m) PHV1000R PHV1500R PHV2000R Holes for M10 drop rods A(mm) 1150 1650 2240 B(mm) N/A 800 1095 C(mm) 1190 1690 2290 55 314 140 296 CEILING LEVEL 35-100mm 476 C Cut-Out Length(mm) 1150 1650 2240 in Ceiling Width(mm) 436 436 436 LPHW connections Rp 3/4 (3/4in.BSP female) 4004175-6 UK Page 5 of 19

Note: When installing the air curtain ensure that the underside of the unit is 50mm above the bottom face of the ceiling tile/plasterboard. The recessed grille has an adjustment range from the underside of the air curtain to the exposed bottom face of the ceiling tile/plasterboard (see Figure 1 or Figure 2). *It is the sole responsibility of the installer to ensure that the fixing points and bolts used are suitable for the air curtain being installed Safety and Electrical Connections All electrical wiring and connections MUST be carried out by a competent qualified electrician in accordance with the latest edition of the IEE wiring regulations and/or local statutory regulations. A single phase or 3 phase local isolator with a contact separation of at least 3mm in all poles must be fitted to the supply wiring (the isolator must be fitted in an accessible position). The air curtain must be earthed. The appliance must be connected using cables having an appropriate temperature rating (heat resistant). Ensure that the supply cables, circuit breakers and other electrical installation equipment are correctly sized for the air curtain being installed; see Table 2. On a 3 phase electrical supply the unit requires a neutral connection (3N~). Cable glands used for the Electrical Input must be rated IP21 or higher. Table 2 Air Curtain Electrical Supply (V/ph/Hz) Rated Power Input (kw) Current per phase (A) Heat Output (kw) Weight (kg) PHV1000AR 230/1/50 0.30 1.3 N/A 33 PHV1500AR 230/1/50 0.40 1.8 N/A 47 PHV2000AR 230/1/50 0.60 2.7 N/A 63 PHV1000WR 230/1/50 0.30 1.3 12.0 40 PHV1500WR 230/1/50 0.40 1.8 18.0 55 PHV2000WR 230/1/50 0.60 2.7 24.0 73 PHV1000ER 400/3/50 12.30 18.7 6.0/12.0 37 PHV1500ER 400/3/50 18.40 27.9 9.0/18.0 53 PHV2000ER 400/3/50 24.60 37.5 12.0/24.0 71 4004175-6 UK Page 6 of 19

Fitting of the Recessed Grille The grille consists of a frame, grille core (fitted within the frame) and four brackets (note: the brackets are fixed to the frame). Removal of Grille Core Prior to fitting the grille to the air curtain and the ceiling the grille core will need to be removed from its frame. Release the grille core by unfastening the two conical head bolts fitted at each end of the grille core. Push against the spring loaded pins and the grille core can now be pulled clear of its frame. Note: the grille core will still be attached to the frame via cord safety ties. The rectangular hole in the ceiling must be sized to suit the grille frame, see Figure 1 or Figure 2 for dimensions. Attaching the Grille to the Air Curtain Before lifting the grille frame into position locate the four M6 bolts (two inside each end of the air curtain). Remove the M6 bolts and lift the frame into position (ensure that when fitted the air discharge vanes align with the air discharge of the air curtain, see Figure 1 or Figure 2), screw each M6 bolt through the slot in the grille bracket until all four are located into place. Adjust the height of the grille frame (via slots in brackets) so the frame fits nicely against the under side of the ceiling. Once the desired height is achieved tighten each M6 bolt in place locking the grille frame into the correct position. Adjusting the Separator Plate Within the air curtain there is a sliding separator plate, this needs adjusting up or down to stop the air discharge re-circulating within the air curtain. To adjust the separator plate release the M6 bolts at either end, extend the slide plate so that it will just touch the topside of the grille along its whole length and tighten the bolts. It will be necessary to fit the grille core to gauge where the separator plate should be fitted. Fitting the Grille Core Once the above is complete the grille core can be refitted, to do so locate each spring loaded pin in its locating hole, push against the spring loaded pins to allow the fixed pins to locate within their fixing holes. Tighten and secure the conical bolts fitted at each end of the grille core. Once the ceiling is finished remove the protective plastic film from the recessed grille frame. 4004175-6 UK Page 7 of 19

LPHW Models For LPHW models ensure suitable water mains isolation valves are fitted in the flow and return pipework. When fitting the 3-port valve ensure that the pipe connections are fitted as detailed below and are in accordance with the manufacturers leaflet supplied with the valve. Air Curtain Water Flow Rate (l/s) Coil Water Pressure Drop (kpa) 82/72 C PHV1000WR 0.29 1.14 PHV1500WR 0.43 2.60 PHV2000WR 0.57 4.72 Ambient Models Ambient units are supplied with a remote switch unit. The switch unit allows the air curtain to be powered ON/OFF and select one of three fan speeds. 4004175-6 UK Page 8 of 19

Fitting/Connecting the Remote Control The Ecopower Plus controller uses extra low voltage to communicate via the RJ control cable supplied. The controller should be located in a suitable place for easy access, it can be fixed to the wall via various fixing slots provided in the back case or onto an electrical switch box (not provided). To mount controller onto an existing switch box, feed one end of the control cable through the switch box (see insert). Using a screwdriver undo screw mounted on the top of the controller case. Pull the front case slightly forwards and lift the back case away. Feed and secure the RJ control cable through one of the openings in the back case and secure back case to switch box using 2 x M3.5 mounting screws (not provided). With the cable RJ plug locking clip lying nearest to controller PCB, connect the RJ plug to the RJ socket on the board. Note: For controller DIP switch options refer to Ecopower Plus Remote Control Operation and DIP Switch Settings. Refit the controller front case to the back case. The air curtain end of the control cable should be connected to one RJ socket fitted either on the top panel for NT or the Ecopower motherboard inside a recessed air curtain. Ensure the control cable is safely secured. Multiple Installation (Ecopower only) To Master/Slave two or more air curtains together the remote control is plugged into the Master unit and a RJ lead should be connected from the Master to the Slave unit(s). Thermoscreens 3m RJ extension leads are available and must be ordered separately. Additional air curtains, up to a maximum of eight units, may be connected as indicated below. For Master/Slave configuration an independent mains supply as per Table 2 must be supplied to each air curtain. 4004175-6 UK Page 9 of 19

Ecopower Controller Motherboard Function Control Comments Standard Fan Heat Interlock The heat output is governed by the fan speed. If low or medium fan speed is selected the heat output will operate on only first heat stage. Second stage heating will only operate on high fan speed. Disable Fan Run-on Disable fan run-on. DIP1 Option ON OFF 1 2 3 4 DIP2 Option (LPHW & Ambient only) Suitable on vertical electrically heated Designer air curtain. Maximum heat output achieved if maximum fan speed selected. Independently set-up DIP switch on each mother board. This feature operates in manual or auto mode. Must only be used for LPHW and Ambient air curtains. Independently set-up DIP switch on each mother board. As supplied, the default setting would be for heat and fan settings to be independent (DIP1 OFF). As supplied, the default setting would enable fan run-on (DIP2 OFF). ON OFF 1 2 3 4 Thermostat Master Only the air sensor thermistor in the master air curtain will be used for measuring the reference air temperature for the whole master/slave installation. Overheat Fan Disable If DIP4 is on and thermal cut-out(s) operate both heat and fan circuits are isolated and LED s on wall switch flash. If DIP4 is off and thermal cut-out(s) operate, only the heating circuit is isolated and the LED s on the wall switch flash. DIP3 Option ON OFF 1 2 3 4 DIP4 Option (Electric only) ON OFF 1 2 3 4 The air sensor thermistors in all the slave air curtains will be ignored. This will then avoid situations on larger doorways with master/slave air curtains where some units can blow cold air whilst others can blow warm air, because they currently all refer to their own air sensor for control of the heat output of each air curtain. The master air curtain need not be the one that the wall control is plugged into. This dip switch setting must also be used for Global Switching (Master/Slave) via the INHIBIT terminal see next page. Independently set-up DIP switch on each mother board. To remove fault, isolate electrical supply to air curtain, reset TOC and reconnect supply. Fan run-on time set two minutes. Built-in If FAN ONLY has been selected, at switch off, no fan runon. As supplied, the default setting would be for the air sensor thermistor on all units to be measuring (DIP3 OFF). As supplied, the default setting would enable fan if TOC trips (DIP4 OFF). - white rectangle indicates the moveable head of each 4 way DIP switch DIP switches fitted on the Ecopower board provide a selection of optional features as described above. Isolate and switch electrical power off before configuring and/or changing any DIP switch settings. 4004175-6 UK Page 10 of 19

Easy plug-in arrangement for remote air sensor thermistor on a 1m lead. Plugging-in the remote air sensor to J3 disables the standard air sensor thermistor already fitted on the Ecopower board. As supplied, the board will not have the remote air sensor fitted. An INHIBIT two screw terminal fitted on the Ecopower board for BMS remote On/Off feature. If the terminal is linked, i.e. by 2 wires to a remote volt free contact, the unit will run. If it is open circuit across the terminal the unit will switch off. This remote On/Off feature has global switching logic, i.e. if you master/slave several units together you need connect the remote contact to only one of them to turn all units on and off in the master/slave system. For global switching to work on the slave units, need to set DIP3 Option (see previous page) on the unit that the remote contact is wired to and have previously turned the unit on with the wall switch. As supplied, a wire link will be fitted to the terminal block on every unit. For summer settings place a 3.3kΩ resistance across the INHIBIT terminal, with these settings fans only will run even if controller is requesting for heat. Customer Building Management System ECOPOWER BOARD A HEALTHY two screw terminal is included on the board for a fault signal indication if the electric elements overheat cut-out has operated. A healthy system provides a 24V DC signal at the terminals compared to an overheat fault which provides OV DC. 4004175-6 UK Page 11 of 19

4004175-6 UK Page 12 of 19

4004175-6 UK Page 13 of 19

4004175-6 UK Page 14 of 19

4004175-6 UK Page 15 of 19

Ecopower Plus Remote Control Operation and DIP Switch Settings 1 2 7 6 4 3 5 Heating Level Scale On/Off (I/O) Press On/Off switch (1) to turn the air curtain On and operate as follows:- Press Auto switch (2) to cycle between Manual and Automatic modes. The Auto on indicator LED is lit for "Auto Mode" and un-lit for "Manual Mode". Manual: Heat output can be selected as Zero, Half Heat or Full Heat. Heating levels are selected by stepping up or down with switches (3) and (4). Heating level indicator LED's go 0%, 50% or 100% to show the level selected. Automatic: If DIP switches 1, 2 and 4 on the Ecopower motherboard are set to OFF, the air curtain measures the incoming air temperature and automatically selects the necessary amount of heat to keep it at the level selected. Fan Speed Switches (5), (6) and (7) select fan speed low, medium or high respectively. The appropriate LED above each fan speed indicator is illuminated to show which fan speed is selected. Pressing the On/Off switch (1) again switches the air curtain off with all the LED s switched off. If a heated air curtain is heating when switched off the fan will run-on at low fan speed for an extended time (approx. 2 minutes) to dissipate excess heat. DIP Switch Settings At the back of the Ecopower Plus remote control PCB there are four DIP switches (see above) that provide the following optional features. DIP1 DIP2 DIP3 DIP4 Restart on Power-Up If electrical supply to the air curtain is interrupted, upon restoring electrical supply, the customer s settings on the remote control will be retained. The default is with this feature ON. Stop Fan on Cold Fans switch off when heating level is achieved (Automatic mode only). The default setting is with this feature OFF. Never Blow Cold Unit always heats in Automatic mode (i.e. will not go to ambient mode). The default setting is with this feature OFF. Air Sensor in Controller The air sensor in the remote controller is enabled (DIP4 ON) and the air sensor on the Ecopower motherboard in the air curtain is disabled. Temperature control for Automatic Mode is then done at the remote control, which may be an advantage to limit overheating of the door entrance area. The default setting is with this feature OFF. Do not switch the air curtain On/Off from the isolator. If the mains supply is isolated or cuts-out during operation the safety thermal cut-out(s) for electric heated air curtains within the air curtain may operate. If this happens the thermal cut-out(s) will need to be reset by a competent technician. 4004175-6 UK Page 16 of 19

Commissioning Once the air curtain is functioning check that the fans operate at Low, Medium and High speeds, that there is no excessive mechanical noise coming from the fans and that all fans are working. If the unit is electric heated or water heated check that the air stream from the discharge grille warms up across the whole length of the air curtain when heating is selected. Check that heating increases as higher heat is selected and feel to see that the warm air stream is reaching across the doorway with door open or closed. If an Ecopower controller is being used check its operation in Manual Mode. Then select Auto Mode and increase the heating set point until the air stream warms up. Reduce the heating set point until the air stream goes cold. Explain to the end user that the doorway should be closed whenever possible but that during times of high pedestrian use it will become effectively open doorway. The air curtain serves an essential purpose by saving energy and providing comfort to the occupants when compared to an open doorway with no air curtain fitted. Before leaving site it is important that the air curtain installation is Handed-Over to the end user or his representative and the operation of it is fully explained and that they understand how it operates. Explain also the service intervals and that the unit must be regularly cleaned and if it has filters fitted that these require regular cleaning/replacement. Fault Conditions In the event of a fault the thermal cut out(s) on electric heated units (Note: If the mains supply is isolated during operation then the thermal cut outs may operate) or internal fuses may operate. The thermal cut out(s) are located within the unit directly above the element banks (one on the 1 & 1.5m and two on the 2m model). For Ecopower units two internal electrical fuses are located on the Ecopower board; 6.3A (T) supplies the fan motors within the air curtain and 125mA (F) controls the operation of the Ecopower board. For Ambient and Standard LPHW units the fuse is located within the control panel at the left hand end of the air curtain. If for an electric heated air curtain an overheat fault occurs, or if J2 link is missing for LPHW models, the LED s on the remote control will flash and the Ecopower board status LED on the board will be permanently red to indicate a fault. In the case of a fault condition (refer to flowchart) do not attempt to reset the thermal cut outs or replace the fuses, arrange for a Thermoscreens appointed technician or certified electrician to attend the unit to investigate the reason why the thermal cut outs/fuse(s) have operated. Once the cause has been determined and rectified, they will reset/replace the thermal cut out/fuse and function test the unit. PCB Status Fitted on the PCB board inside of the air curtain is an LED shown as LED1 on wiring diagrams that will indicate the Ecopower control status. 1. LED flashing green operation normal. 2. LED flashing red low supply voltage or controller not plugged into Ecopower motherboard. 3. LED permanently red thermal cut outs open circuit (electrically heated models) or J2 link missing (LPHW models). Remote Control LED s will also flash to indicate the thermal cut-out(s) has operated or J2 link is missing. Note to reset the thermal cut outs please refer to Fault Conditions section detailed above. 4004175-6 UK Page 17 of 19

User Fault Finding Flowchart (for Ecopower Control) Is Electrical Power switched on No Switch on Electrical Power Yes Service Agent to reset thermal cutout(s) Connect remote control and push On/Off switch to turn unit on Are the fans operating correctly No No Service Agent to investigate why thermal cut-out(s) have operated Yes Do the LED s light up on the remote control No Is the remote control plugged in and turned on Select heat output Yes Yes Yes Check if thermal cut-out(s) have tripped (Electric Heated only) No Is the unit discharging warm air Contact Installer No Yes Contact Installer Unit is working satisfactorily 4004175-6 UK Page 18 of 19

Service & Maintenance Always disconnect and isolate the mains electricity supply before installing, maintaining or repairing this equipment. Note: All maintenance/repairs should only be carried out by a competent electrician or Thermoscreens appointed technician. To ensure the air curtain operates at full efficiency the inlet/outlet grilles, fan impellers, housings and motors must be kept free of dust and debris. Build up of dust on the fan impellers can cause vibration, noise and excessive wear on the motor bearings. Frequency of cleaning will depend on the environment, but we would recommend that the unit be cleaned a minimum of every 3 months (failure to adequately maintain the unit and provide a suitable cleaning schedule will result in performance degradation and reduce the life expectancy of the air-curtain). Remove the grille core from the air curtain. Vacuum and clean the build-up of dirt and debris within the air-curtain (please note that the motor(s) are permanently lubricated and require no additional lubrication). If filters are fitted, ensure these are regularly inspected and cleaned or replaced. All dirty or blocked filters should be immediately replaced. Once the air curtain has been cleaned check all electrical connections within the unit ensuring terminals are tight and that crimped connections have not become loose. Refit the grille core in the recessed grille. Reconnect the electrical supply and fully function test the air-curtain to ensure correct operation (See Commissioning). Warranty If any problems are encountered, please contact your installer/supplier. Failing this please contact the Thermoscreens warranty department. All units are covered by a two year warranty period. Care has been taken in compiling these instructions to ensure they are correct, although Thermoscreens disclaims all liability for damage resulting from any inaccuracies and/or deficiencies in this documentation. Thermoscreens retain the right to change the specifications stated in these instructions. Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire England CV11 5AU Email: sales@thermoscreens.com Tel: + 44 (0) 24 7638 4646 Fax: + 44 (0) 24 7638 8578 www.thermoscreens.com 4004175-6 UK Page 19 of 19