CATALOG WATER SOURCE HEAT PUMPS

Similar documents
KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

System architecture. Air treatment Index

CATALOG Chillers 2014

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

YFCN Fan Coil Unit centrifugal fan

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

technical data Fan coil unit FWB small duct unit

SIMPLICITY FULL MODULARITY?

UCS UCS/M UCS/H UCS900

Conditioning your ambient, maximising your comfort.

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.

Packaged air conditioners vertical units

Just feel well. 2017/2018 Air conditioning

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

CATALOGUE EUROPE 2007

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

QTS SELECTION TECHNICAL BOOKLET

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

PRODUCTS GUIDE INTEGRATED COMFORT SYSTEMS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SIMPLICITY OR FULL MODULARITY?

Air Conditioning. Air conditioning. Overview

FAN COIL UNITS. The optimal solution for limited space

QZB "Standard" comfort fan coil

AQUAHEAT ADVANCE SPLIT

Blower-YEFB-020-3R-1maxVel

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

QZHW Fan Coil Unit. Key features. Specifications

FAN COIL UNITS LASER / LOW BODY / CONCEALED

KPSW CONSOLE TERMINAL UNIT

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

LOW STATIC HYDRONIC DUCTED UNIT

Conditioning your ambient, maximising your comfort.

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

E U R O V E N T CERTIFIED PERFORMANCE

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

SIGMA PRISMA LOW BODY CONCEALED

PAC BT LOW TEMPERATURE HEAT PUMP

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

KLIMA Active Chilled Beams

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

UniTrane Ductable Units D-line and B-Line

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Technical documentation Fan coil unit

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

PHOENIX PNX0 DCI. New WALL MOUNTED RANGE. High Glossy Finish AN AIRWELL GROUP COMPANY

HOTEL CHILLED BEAM IQ STAR SILENCIA

EHH SERIES DRAW THROUGH FAN COILS CFM

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CASSETTE UNIT. Comfort Circle

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

b!klimax radiant wall/ceiling system

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

CHILLED BEAM CASSETTE IQ STAR LYRA

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

Transcription:

CATALOG Fan coil UNITS WATER SOURCE HEAT PUMPS DIRECT EXPANSION 2014

An InternatIonaL sales network NORD-PAS- DE-CALAIS PICARDIE HAUTE- NORMANDIE BASSE- NORMANDIE Tillières-sur-Avre ILE-DE-FRANCE Guyancourt CHAMPAGNE- ARDENNE LORRAINE BRETAGNE PAYS-DE- LOIRE CENTRE BOURGOGNE FRANCHE- COMTE POITOU- CHARENTE Pons LIMOUSIN AUVERGNE RHÔNES- ALPES AQUITAINE MIDI- PYRENEES PROVENCE-ALPES- CÔTE-D'AZUR LANGUEDOC- ROUSSILLON Commercial: export@wesper-group.com Aftersales: 33 (0)1 39 44 65 79 Airwell France SAS 1 bis avenue du 8 mai 1945 78280 Guyancourt - FRANCE Tel. +33 (0)1 39 44 78 00 Fax +33 (0)1 39 44 11 55 2 3

Wesper quality innovation & QUalitY Innovation and Quality are one important parts of Wesper s philosophy. Spending all our energy to continuously develop innovative products for our customer will ensure our market position. More than 130 people are devoted to study products with a special are to the energy efficiency and acoustic emission issues for a better quality of life. Certifications The company plants are ISO 9001 certified by most recognised certification bodies and participates in the renowned Eurovent Certification program, a voluntary initiative which ensures that capacity ratings and design properties have been verified by independent laboratories according to international standards. technology & environment Wesper s primary objective is to design and offer air conditioning systems that meet both the highest standards of environmental protection and users legitimate expectations in terms of comfort and wellbeing. For Wesper, innovation has to be linked tightly to a respect for the environment and must include stringent requirements in terms of quality levels. This ongoing concern governs all our actions and involves all our human and technological resources. In accordance with this principle and with European Directives, in its appliances, Wesper uses ecological refrigerant fluids of the HFC type (R410A & R407C) that do not harm the planet s ozone layer. Moreover, with a constant care for participating in preserving the environment, Wesper designs and markets high efficiency products that reduce CO2 emissions into the atmosphere and minimize our contribution to global warming. environment ENERGY SAVING Spare Parts: the optimal reactivity Providing spare parts from Wesper origin is critical for good reliability and long life of our machines. That is why we have installed our European spare parts centre in France in Tillières (100 km West from Paris) on a factory site. With more than 12 000 references in stock and very professional teams dedicated to customer service, we can deliver parts in Europe within 2 to 3 days after validating customer order (depending on the availability and specific constraints linked to the weight and size of the component). Spare parts department could be reached by: Fax: +33 (0)2 32 32 50 33; Letter at following address: AIRWELL France SAS, Spare Parts Department, Route de Verneuil, 27570 Tillières sur Avre, FRANCE. E-mail: preairwell-group.com A technical support able to answer to all requests On the French territory Wesper CAC business has a network of more than 10 ASTS companies with a good knowledge of our products and trained on a regularly basis. They are able to provide service like start-up for all machines of our professional product range like chillers, rooftops, Heat pump In the meantime, we offer for our French and Export customers a technical phone support given by our Technical after sales experts for all questions relative to installation, commissioning or maintenance. For French customers they are available at following number: 0891 700 407 from 8.30 AM to 12.30 PM and from 2 PM to 5 PM, from Monday to Friday. For Export customers, you have to dial +33 5 46 92 32 77. For any specific question which requires a deeper expertise, we are able to arrange a travel on site by one of out technical expert in after sales in order to study with the installer the main causes of the request and the solution to be implemented. HEAT RECOVERY plug & play 4 5

Our History 1947 Paul Wallet founded L Air Conditionné Entreprise which later became the core of Airwell Group. 1950 The Company developed and began the mass production of the first window unit, to offer exceptional climate conditions, mainly dedicated to European and African markets. 1970 Airwell developed a split system unit by splitting its core window unit in two parts, and was the first to produce wall split systems in Europe. 1975 Airwell entered the commercial and industrial markets with large cooling capacity for packaged air and water-cooled systems. 1979 After the two oil crises in the 70s Airwell developed the first high-efficiency air to water heatpump to be connected to existing oil boilers in residential housing for oil energy saving. 1982 Airwell designed and produced the first European wall split system range including electronic remote control, a high technology cross-flow fan for low noise levels, and rotary compressors. Founded in 1947, Airwell Group is one of the globally leading manufacturers and distributors of air conditioners and central air conditioning systems. The company has production facilities and marketing subsidiaries worldwide. Contents WATER TERMINAL UNITS Kw page Water terminal units selection guide 12 AquaFan II AWC/AHC STD Fan coil 1,9/9 14 AquaFan IIAWC/AHC EC Fan coil 1,9/5,7 16 AquaFan II AWN/AHN STD Fan coil 1,9/9 18 AquaFan II AWN/AHN EC Fan coil 1,9/5,7 20 AquaFan All Electrical Version Fan coil 1,1/7,2 22 Accessories AquaFan Fan coil 24 WKW LN STD 4 way chilled water cassette 2,3/10,2 28 WKW LN EC 4 way chilled water cassette 2,2/4,6 30 KCO2 1 way chilled water cassette 1,1/3,3 34 KCO2 EC 1 way chilled water cassette 0,8/3,8 36 Hawair High wall chilled water unit 2,2/4,7 38 DUCTYS Pressure ductable fan coil unit 1,2/3,3 40 VH STD High static pressure dectable fan 2,1/28,4 42 VH EC High static pressure dectable fan 5,5 44 Accessories DUCTYS and VH 5,5 46 VPN Fan coil unit 1,8/12,6 48 1993/1996 The Group grew with the acquisition of Spanish, Italian, German and French distribution companies, as well as the factory in Tillieres. 1998/2001 The Group strengthened its position by acquiring production facilities in China, France (Wesper) and Italy, and extended its distribution network in Argentina and Turkey. 2004/2006 In order to accentuate its position in the market, the Group opened an office in Russia and acquired Polenz Klimatechnik in Germany. 2008 The Group reinforced its position in the American continent by acquiring the Fedders Residential Business (USA). WATER SOURCE HEAT PUMPS Water source heat pumps selection guide 54 STORM 2 Electronic control 56 EFTYS Water source heat pump 1,9/3 58 HRW Water source heat pump 5,3/30 62 EWH Water source heat pump 3,9/43 66 CW-AR Water source heat pump 1,9/2,7 68 DK DN Air-to-air split system 12/83 72 XAR UC Vertical air cabinet 9,7/55 76 XAO Vertical water cabinet 8/45,7 78 CDN Air-cooled condensing chiller 19/83 80 Generals TERMS 84 page 6 7

Water Terminal Units 8 9

A LARGE RANGE TO OFFER A SOLUTION FOR HEACH NEED Innovation AND EASY INSTALLATION WIDE RANGE OF CONTROL A large range of terminal units dedicated to energy saving and comfort: Low consumption solution with: High efficiency fan motor available on fan coil, ducted fan coil and cassette range High level of energy performance with mainly Energy class A or B Same thermal performance as with AC fan motor Blue fin coils on all terminal range for efficient and hygienic solution Silence Optimized fan speed staging for new low noise versions Reinforced acoustical insulation Profiled air diffuser Cost-optimized 3-speed setting for EC fan Control ready-to-install Play diffuser with grill on hinges FACTORY FACILITIES DEDICATED TO FLEXIBILITY AND QUALITY Many factory-mounted options or accessories: Control Valve Air diffuser Condensate drain pump Airwell Group is engaged in a permanent research of energy saving on and all around his product range. This logo is the witness of this voluntary gait in terms of: Engagement Efficiency Energy Products fully customized to satisfy your requirements: Choice of service side for hydraulic and electric connection Version with or without cabinet On-board control 100% units are tested electrically and acoustically. All Terminals Units are according to Eurovent standard. 10 11

Water terminal units SElection GUIDE WATER terminal UNITS 0KW 5 10 15 20 25 30KW A20 1,9 kw NR 31 at HS 132-317 m³/h LxHxW : 768x478x231 Chilled water cassette Fan coil Units KCO2 WKW AQUAFAN II TTE AQUAFAN II HOTEL HOTEL OFFICES OFFICES HOSPITAL HOSPITAL A30 A40 A50 A60 A70 A80 A20 E A40 E A60 E WKW LN WKW LN WKW LN WKW LN WKW LN KCO2 60 KCO2 90 KCO2 120 2,4 kw 3,5 kw 4,2 kw 5,2 kw 7,2 kw 9 kw 2,3 kw 4,5 kw 7,2 kw 0KW 5 10 15 20 25 30KW 2,3 kw 3,5 kw 4,6 kw 6,4 kw 10,2 kw 1,6 kw 3,2 kw 4,1 kw NR 36 at HS NR 29 at HS NR 33 at HS NR 39 at HS NR 41 at HS NR 44 at HS NR 29 at HS NR 30 at HS NR 42 at HS NR 27 at HS NR 27 at HS NR 28 at HS NR 37 at HS NR 40 at HS NR 28 at HS NR 23 at HS NR 23 at HS 181-407 m³/h 295-570 m³/h 333-736 m³/h 468-917 m³/h 545-1150 m³/h 665-1376 m³/h 137-358 m³/h 312-672 m³/h 492-1018 m³/h 330-720 m³/h 330-720 m³/h 290-830 m³/h 1100-1550 m³/h 1000-1630 m³/h 140-305 m³/h 200-560 m³/h 290-680 m³/h 0-30Pa EC 0-40Pa 0-Pa N/A N/A EC 0-Pa 0-Pa EC LxHxW : 935x478x231 LxHxW : 1138x478x231 LxHxW : 1323x478x231 LxHxW : 1508x478x231 LxHxW : 1323x578x231 LxHxW: 1508x478x231 LxHxW : 768x478x231 LxHxW : 1138x478x231 LxHxW : 1508x478x231 LxPxW : 625x625x287 LxPxW : 625x625x287 LxPxW : 625x625x287 LxPxW : 1225x625x287 LxPxW : 1225x625x287 LxPxW : 492x492x309 LxPxW : 970x492x309 LxPxW : 1192x492x309 0KW 5 10 15 20 25 30KW High wall chilled water unit HAWAIR HOTEL HAW 07 HAW 09 HAW 18 HAW 22 2,2 kw 2,9 kw 3,6 kw 4,7 kw NR 27 at HS NR 29 at HS NR 35 at HS NR 41 at HS 320-450 m³/h 400-600 m³/h 550-750 m³/h 650-900 m³/h 0-Pa N/A LxPxW : 845x275x180 LxPxW : 845x275x180 LxPxW : 940x298x200 LxPxW : 940x298x200 0KW 5 10 15 20 25 30KW LxHxP : 1138x478x231 High static pressure ductable fancoil unit DUCTYS VH OFFICES FACTORY DUCTYS 1500 DUCTYS 2000 DUCTYS 2500 VH07 VH15 VH18 VH21 VH24 2 kw 2,5 kw 3,3 kw 6,2 kw 14,8 kw 18,9 kw 21,9 kw 23,9 kw NR 30 at HS NR 31 at HS NR 31 at HS NR 34 at HS NR 40 at HS NR 40 at HS NR 40 at HS NR 44 at HS 270-505 m³/h 370-600 m³/h 440-640 m³/h 648-1251 m³/h 671-3176 m³/h 671-3176 m³/h 671-3176 m³/h 1938-3882 m³/h 0-80Pa 0-150Pa EC EC LxPxW : 581 x 640 x 223 LxPxW : 581 x 740 x 223 LxPxW : 581 x 840 x 223 LxPxW : 698x1200x250 LxPxW : 798x1380x375 LxPxW : 798x1380x375 LxPxW : 798x1380x375 LxPxW : 798x1500x450 VH27 28,4 kw NR 44 at HS 1938-3882 m³/h LxPxW : 798x1500x450 Total cooling capacity at HS, Eurovent conditions. 12 13

Fan coil units AquaFan II AWC/AHC STD FAN COIL UNIT COOLING AND HEATING AquaFan II AWC/AHC STD Size 20 30 40 50 60 70 80 CAPACITIES - 2 Pipe V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Total cooling capacity W 1040 / 1470 / 1870 1520 / 2130 / 2440 2190 / 2620 / 3460 2100 / 2800 / 4220 3400 / 4390 / 5730 3920 / 5610 / 7210 4750 / 6650 / 9040 Cooling (1) Sensible capacity W 750 / 1110 / 1480 1020 / 1560 / 1940 1600 / 1970 / 2730 1420 / 1920 / 2980 2220 / 2860 / 3850 2890 / 4170 / 5640 3510 / 4920 / 6890 Water flow l/h 178 / 215 / 321 263 / 367 / 418 375 / 450 / 594 362 / 482 / 725 583 / 753 / 983 673 / 765 / 1243 814 / 1142 / 1548 Water pressure drop kpa 3 / 5 / 8 7 / 12 / 16 14 / 20 / 33 8 / 14 / 29 16 / 26 / 42 8 / 16 / 25 12 / 23 / 39 Heating (2) Heating capacity W 1240 / 2020 / 2530 1740 / 2610 / 3400 2690 / 3500 / 4570 2830 / 3710 / 5410 3990 / 5250 / 7360 4940 / 6900 / 9180 5990 / 8360 / 11300 OFFICES CAPACITIES - 4 Pipe Total cooling capacity W 1080 / 1540 / 1970 1480 / 2080 / 2390 2130 / 2560 / 3400 2430 / 3250 / 4220 3310 / 4290 / 5610 3810 / 5470 / 7120 4630 / 6490 / 8830 Cooling (1) Sensible capacity W 760 / 1140 / 1520 990 / 1520 / 1880 1550 / 1920 / 2660 1740 / 2370 / 3000 2170 / 280 / 3770 2810 / 4060 / 5540 3410 / 4780 / 6710 Water flow l/h 184 / 266 / 338 256 / 356 / 411 367 / 439 / 583 418 / 558 / 724 569 / 735 / 961 655 / 940 / 1228 792 / 1113 / 1516 Cooling Capacity: from 1.9 to 9.0 kw Heating Capacity: from 2.3 to 11.6 kw Sizes: 7 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical console with cabinet Ceiling exposed with cabinet Product Avantages HOTEL Ease of installation. Harmonuous and aesthetic RAL9003 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. 5-speed AC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 1400 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with Aqu@net control. AC motor. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Front or bottom air intake configuration. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Fuse holder. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Selection Software Select It. Water pressure drop kpa 14 / 27 / 42 7 / 12 / 15 14 / 19 / 31 8 / 13 / 20 16 / 25 / 40 8 / 15 / 24 12 / 22 / 38 Heating (3) Water flow l/h 121 / 174 / 204 189 / 246 / 292 281 / 327 / 398 340 / 428 / 460 366 / 448 / 531 375 / 461 / 611 592 / 8280 / 1014 Heating capacity W 1390 / 1980 / 2320 2160 / 2800 / 3340 3210 / 3730 / 4540 3230 / 4010 / 5250 4180 / 5110 / 6060 4280 / 5270 / 6980 6750 / 9430 / 11600 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / 25 21 / 32 / 50 8 / 11 / 15 9 / 15 / 24 18 / 33 / 48 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66 FANS (LS/MS/HS) Sound pressure level (4) db(a) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53 38/46/57 41/48/58 NR (4) db(a) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48 34/41/52 36/44/54 Number 1 1 2 2 2 2 3 Airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917 545/799/1150 665/934/1376 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 Fan consumption W 5/12/27 10/20/33 7/15/35 8/19/45 18/30/72 92/110/150 90/112/188 Electrical heater (max) W 900 1200 2000 2400 3000 3000 - WATER CONNECTIONS Type Gas female threaded DIMENSIONS WEIGHT Cooling coil inches 1/2" Heating coil inches 1/2" LxWxH mm 768 x 478 x 231 953 x 478 x 231 1138 x 478 x 231 1323 x 478 x 231 1508 x 478 x 231 1323 x 578 x 231 1508 x 578 x 231 Unit weight kg 20 23 30 35 39 42 42 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. NEW: on stock! Configuration: 2 or 4-pipes, terminal block, without valve, left service side. Accessories for customization on site also available on stock - See page 26 and 27. Please consult us to get the last updated information on leadtime. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 17 bars 5 C/15% RH 32 C/70% RH AquaFan II 20 30 40 50 60 2 Pipe Without valve AWC AHC 7OG033131 7OG033132 7OG033133 7OG033134 7OG033135 Price 530 599 622 669 777 4 Pipe Without valve AWC AHC 7OG033141 7OG033142 7OG033143 7OG033144 7OG033145 Price 581 654 685 737 863 On stock 14 15

Fan coil units AquaFan II AWC/AHC EC FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1.9 to 5.7 kw Heating Capacity: from 2.3 to 7.4 kw Sizes: 5 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical console with cabinet Ceiling exposed with cabinet Product Avantages OFFICES HOTEL Ease of installation. Harmonuous and aesthetic RAL9003 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. Low consumption EC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 900 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod 4 heating capacity available per model. 2-stage heater available with Aquanet control. EC motor. Selection of 3 speed with ECospeed3 board. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Front or bottom air intake configuration. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Selection Software Select It. AquaFan II AWC/AHC EC Size 20 30 40 50 60 70 CAPACITIES - 2 Pipe Total cooling capacity W 1040 / 1470 / 1870 1520 / 2130 / 2440 2190 / 2620 / 3460 2100 / 2800 / 4220 3400 / 4390 / 5730 Sensible capacity W 750 / 1110 / 1480 1020 / 1560 / 1940 1600 / 1970 / 2730 1420 / 1920 / 2980 2220 / 2860 / 3850 Cooling (1) Water flow l/h 178 / 215 / 321 263 / 367 / 418 375 / 450 / 594 362 / 482 / 725 583 / 753 / 983 Water pressure drop kpa 3 / 5 / 8 7 / 12 / 16 14 / 20 / 33 8 / 14 / 29 16 / 26 / 42 Heating (2) Heating capacity W 1240 / 2020 / 2530 1740 / 2610 / 3400 2690 / 3500 / 4570 2830 / 3710 / 5410 3990 / 5250 / 7360 CAPACITIES - 4 Pipe Total cooling capacity W 1080 / 1540 / 1970 1480 / 2080 / 2390 2130 / 2560 / 3400 2430 / 3250 / 4220 3310 / 4290 / 5610 Sensible capacity W 760 / 1140 / 1520 990 / 1520 / 1880 1550 / 1920 / 2660 1740 / 2370 / 3000 2170 / 280 / 3770 Cooling (1) Water flow l/h 184 / 266 / 338 256 / 356 / 411 367 / 439 / 583 418 / 558 / 724 569 / 735 / 961 Water pressure drop kpa 14 / 27 / 42 7 / 12 / 15 14 / 19 / 31 8 / 13 / 20 16 / 25 / 40 Heating (3) Water flow l/h 121 / 174 / 204 189 / 246 / 292 281 / 327 / 398 340 / 428 / 460 366 / 448 / 531 Heating capacity W 1390 / 1980 / 2320 2160 / 2800 / 3340 3210 / 3730 / 4540 3230 / 4010 / 5250 4180 / 5110 / 6060 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / 25 21 / 32 / 50 8 / 11 / 15 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 Sound pressure level (4) db(a) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53 NR (4) db(a) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48 FANS (LS/MS/HS) Number 1 1 2 2 2 Airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 Fan consumption W 5/12/27 10/20/33 7/15/35 8/19/45 18/30/72 Set voltage V 1,7 / 3,3 / 5,5 3,1 / 4,9 / 8,2 2,4 / 3,9 / 6,2 2,8 / 4,9 / 7,5 4,5 / 6,0 / 8,9 Electrical heater (max) W 900 1200 2000 2400 3000 WATER CONNECTIONS Type Gas female threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMENSIONS LxWx mm 768 x 478 x 231 953 x 478 x 231 1138 x 478 x 231 1323 x 478 x 231 1508 x 478 x 231 WEIGHT Unit weight kg 20 23 30 35 39 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. Accessories for customization on site also available on stock - See page 26 and 27. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 17 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 16 17

Fan coil units AquaFan II AWN/AHN STD FAN COIL UNIT COOLING AND HEATING AquaFan II AWN/AHN STD Size 20 30 40 50 60 70 80 CAPACITIES - 2 Pipe V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Cooling (1) Total cooling capacity W 1040 / 1470 / 1870 1520 / 2130 / 2440 2190 / 2620 / 3460 2100 / 2800 / 4220 3400 / 4390 / 5730 3920 / 5610 / 7210 4750 / 6650 / 9040 Sensible capacity W 750 / 1110 / 1480 1020 / 1560 / 1940 1600 / 1970 / 2730 1420 / 1920 / 2980 2220 / 2860 / 3850 2890 / 4170 / 5640 3510 / 4920 / 6890 Water flow l/h 178 / 215 / 321 263 / 367 / 418 375 / 450 / 594 362 / 482 / 725 583 / 753 / 983 673 / 765 / 1243 814 / 1142 / 1548 Water pressure drop kpa 3 / 5 / 8 7 / 12 / 16 14 / 20 / 33 8 / 14 / 29 16 / 26 / 42 8 / 16 / 25 12 / 23 / 39 OFFICES Heating (2) Heating capacity W 1240 / 2020 / 2530 1740 / 2610 / 3400 2690 / 3500 / 4570 2830 / 3710 / 5410 3990 / 5250 / 7360 4940 / 6900 / 9180 CAPACITIES - 4 Pipe 5990 / 8360 / 11300 HOTEL Cooling (1) Total cooling capacity W 1080 / 1540 / 1970 1480 / 2080 / 2390 2130 / 2560 / 3400 2430 / 3250 / 4220 3310 / 4290 / 5610 3810 / 5470 / 7120 4630 / 6490 / 8830 Sensible capacity W 760 / 1140 / 1520 990 / 1520 / 1880 1550 / 1920 / 2660 1740 / 2370 / 3000 2170 / 280 / 3770 2810 / 4060 / 5540 3410 / 4780 / 6710 Water flow l/h 184 / 266 / 338 256 / 356 / 411 367 / 439 / 583 418 / 558 / 724 569 / 735 / 961 655 / 940 / 1228 792 / 1113 / 1516 Cooling Capacity: from 1.9 to 9.0 kw Heating Capacity: from 2.3 to 11.6 kw Sizes: 7 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical concealed without cabinet Ceiling concealed without cabinet Product Avantages Ease of installation. 5-speed AC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 1400 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with Aquanet control. AC motor. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Various air intake configuration. Ducted plenum for air intake or dischage. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage. Selection Software Select It. Water pressure drop kpa 14 / 27 / 42 7 / 12 / 15 14 / 19 / 31 8 / 13 / 20 16 / 25 / 40 8 / 15 / 24 12 / 22 / 38 Heating capacity W 1390 / 1980 / 2320 2160 / 2800 / 3340 3210 / 3730 / 4540 3230 / 4010 / 5250 4180 / 5110 / 6060 4280 / 5270 / 6980 6750 / 9430 / 11600 Heating (3) Water flow l/h 121 / 174 / 204 189 / 246 / 292 281 / 327 / 398 340 / 428 / 460 366 / 448 / 531 375 / 461 / 611 592 / 8280 / 1014 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / 25 21 / 32 / 50 8 / 11 / 15 9 / 15 / 24 18 / 33 / 48 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66 Sound pressure level (4) db(a) <15/24/32 16/27/35 16/21/31 16/24/34 22/31/40 27/35/44 28/35/45 NR (4) db(a) <15/19/28 <15/23/31 <15/16/26 <15/20/30 18/26/35 23/30/39 23/31/41 FANS (LS/MS/HS) Number 1 1 2 2 2 2 3 Airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917 545/799/1150 665/934/1376 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230/1/50 Fan consumption W 16/27/45 24/40/60 33/39/57 39/45/66 41/64/107 92/110/150 90/112/188 Electrical heater (max) W 900 1200 2000 2400 3000 3000 - WATER CONNECTIONS Type Gas female threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMENSIONS LxWxH mm 510 x 430 x 220 695 x 430 x 220 880 x 430 x 220 1065 x 430 x 220 1250 x 430 x 220 1065 x 530 x 220 1250 x 530 x 220 WEIGHT Unit weight kg 14 16 23 27 30 34 41 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. NEW: on stock! Configuration: 2 or 4-pipes, terminal block, without valve, left service side. Accessories for customization on site also available on stock - See page 26 and 27. Please consult us to get the last updated information on leadline. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 17 bars AquaFan II 20 30 40 50 60 2 Pipe Without valve AWN AHN 7OG033136 7OG033137 7OG033138 7OG033139 7OG033140 Price 461 510 529 570 675 4 Pipe Without valve AWN AHN 7OG033146 7OG033147 7OG033148 7OG033149 7OG033150 Price 511 566 592 639 761 On stock Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 18 19

Fan coil units AquaFan II AWN/AHN EC FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1.9 to 5,7 kw Heating Capacity: from 2.3 to 7,4 kw Sizes: 5 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical concealed without cabinet Ceiling concealed without cabinet Product Avantages Ease of installation. Low consumption EC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 900 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. OFFICES HOTEL Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with Aqu@net control. EC motor. Selection of 3 speed with ECospeed3 board. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Front or bottom air intake configuration. Ducted plenum for air intake or dischage. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage. Selection Software Select It. AquaFan II AWN/AHN EC Size 20 30 40 50 60 70 CAPACITIES - 2 Pipe V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Total cooling capacity W 1040 / 1470 / 1870 1520 / 2130 / 2440 2190 / 2620 / 3460 2100 / 2800 / 4220 3400 / 4390 / 5730 Sensible capacity W 750 / 1110 / 1480 1020 / 1560 / 1940 1600 / 1970 / 2730 1420 / 1920 / 2980 2220 / 2860 / 3850 Cooling (1) Water flow l/h 178 / 215 / 321 263 / 367 / 418 375 / 450 / 594 362 / 482 / 725 583 / 753 / 983 Water pressure drop kpa 3 / 5 / 8 7 / 12 / 16 14 / 20 / 33 8 / 14 / 29 16 / 26 / 42 Heating (2) Heating capacity W 1240 / 2020 / 2530 1740 / 2610 / 3400 2690 / 3500 / 4570 2830 / 3710 / 5410 3990 / 5250 / 7360 CAPACITIES - 4 Pipe Total cooling capacity W 1080 / 1540 / 1970 1480 / 2080 / 2390 2130 / 2560 / 3400 2430 / 3250 / 4220 3310 / 4290 / 5610 Sensible capacity W 760 / 1140 / 1520 990 / 1520 / 1880 1550 / 1920 / 2660 1740 / 2370 / 3000 2170 / 280 / 3770 Cooling (1) Water flow l/h 184 / 266 / 338 256 / 356 / 411 367 / 439 / 583 418 / 558 / 724 569 / 735 / 961 Water pressure drop kpa 14 / 27 / 42 7 / 12 / 15 14 / 19 / 31 8 / 13 / 20 16 / 25 / 40 Heating (3) Water flow l/h 121 / 174 / 204 189 / 246 / 292 281 / 327 / 398 340 / 428 / 460 366 / 448 / 531 Heating capacity W 1390 / 1980 / 2320 2160 / 2800 / 3340 3210 / 3730 / 4540 3230 / 4010 / 5250 4180 / 5110 / 6060 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / 25 21 / 32 / 50 8 / 11 / 15 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34 / 43 / 53 37 / 48 / 56 37 / 42 / 52 37 / 45 / 55 43 / 52 /61 Sound pressure level (4) db(a) <15 / 24 / 32 16 / 27 /35 16 / 21 / 31 16 / 24 / 34 22 / 31 / 40 NR (4) db(a) <15 / 19 / 28 <15 / 23 / 31 <15 / 16 / 26 <15 / 20 / 30 18 / 26 / 35 FANS (LS/MS/HS) Number 1 1 2 2 2 Airflow m³/h 132 / 223 / 317 181 / 290 / 407 295 / 385 / 570 333 / 471 / 736 468 / 650 / 917 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 Fan consumption W 5 / 12 / 27 10 / 20 / 33 7 / 15 / 35 8 / 19 / 45 18 / 30 / 72 Set voltage V 1,7 / 3,3 / 5,5 3,1 / 4,9 / 8,2 2,4 / 3,9 / 6,2 2,8 / 4,9 / 7,5 4,5 / 6,0 / 8,9 Electrical heater (max) W 900 1200 2000 2400 3000 WATER CONNECTIONS Type Gas Female Threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMEN- SIONS LxWxH mm 510x430x220 695x430x220 880x430x220 1065x430x220 1250x430x220 WEIGHT Unit weight kg 14 16 23 27 30 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. List of accessories is available page 26 and 27. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 17 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 20 21

Fan coil units AquaFan AWC/AHC AWN/AHN FAN COIL UNIT ALL ELECTRICAL VERSION OFFICES AquaFan A20E A40E A60E Air flow (m3/h) Electrical heating capacicty (W) Total electrical consumption (W) HS m³/h 358 672 1018 MS m³/h 221 495 723 LS m³/h 137 312 492 HS W 2250 4500 7200 MS W 2250 4500 7200 LS W 1125 2250 3600 HS W 2295 4549 7308 MS W 2276 4539 7272 LS W 1140 2284 3643 Cooling Capacity: from 1,1 to 7,2 kw Versions: 3 models: A20E-A40E-A60E Configurations: Vertical console with cabinet Ceiling exposed with cabinet Vertical concealed without cabinet Ceiling concealed without cabinet 230 V / 1Ph / 50 Hz 400 V / 3Ph / 50 Hz Absorbed intensity (A) HS W 9,98 19,78 MS W 9,9 19,73 LS W 4,96 9,93 Fuse (gg) (A) 12 25 Absorbed intensity (A) HS W 3,31 6,57 10,55 MS W 3,29 6,55 10,5 LS W 1,65 3,3 5,26 Fuse (gg) (A) 4 8 16 Accessories for customization on site available - See pages 24 and 25. Product Avantages Ease of installation Harmonuous and aesthetic RAL9003 painted cabinet design Streamlined design and elaborate finish enabling harmonious integration 5-speed AC fan motor Very low operating acoustical levels Airflow rate between 140 and 1400 m3/h Electrical Aquafan II A20E A40E A60E Unit delivered with Aquanet control and RCL remote control. Price 2250 W 4500 W 7200 W 7VE031100 7VE031101 7VE031102 1 670 1 873 2 044 Main Options 2-stage heater available with Aquanet control AC motor with 3 speeds pre-wired Aquanet control delivered in standard with the unit Main Accessories ModBus Communication interface board UBMS Control Front or bottom air intake configuration Motorized or manual fresh air damper 22 23

Fan coil units AccessorieS AquaFan II ACCESSORiES (supplied loose) 20 30 40 50 60 70 80 MP Support feet for AWC Support feet for AWN MPG External Grillle for TMT BAC Auxiliary drain pan for AWC/AWN Auxiliary drain pan for AHC/AHN PRC Drain pan pump FA RVCA-RT RVCA-RC RVCM-RT RVCM-RC Plénum APS Plénum APSA External filter section for AHN when ducted at suction side Air intake arrangement with motorized (non controlled) on/off damper (back or/and front intake) Air intake arrangement with motorized (non controlled) on/off damper (floor or/and front intake) Air intake arrangement with manual damper (back or/and front intake) Air intake arrangement with manual damper (floor or/and front intake) Discharge plenum with duct 1 x 200 mm for AWN/AHN Discharge plenum with duct 1 x 250 mm Ob for AWN/AHN Discharge plenum with duct 2 x 200 mm for AWN/AHN Discharge plenum with duct 3 x 200 mm for AWN/AHN Discharge plenum with duct 3 x 250 mm Ob for AWN/AHN Return & Discharge plenum with duct 1 x 200 mm Return & Discharge plenum with duct 1 x 250 mm Ob Return & Discharge plenum with duct 2 x 200 mm Return & Discharge plenum with duct 3 x 200 mm Return & Discharge plenum with duct 3 x 250 mm Ob Kit code 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 Price kit 57 57 57 57 57 57 57 Kit code 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 Price kit 55 55 55 55 55 55 55 Kit code 7ACVF0330 7ACVF0331 7ACVF0332 7ACVF0333 7ACVF0334 7ACVF0333 7ACVF0334 Price kit 48 49 51 52 56 52 56 Kit code 7ACTL0394 Price kit 27 27 27 27 27 27 27 G = 7ACTL0448 Kit code G=7ACTL0446 D=7ACTL0445 D = 7ACTL0447 - Price kit 27 27 n.a. Kit code AWC AWN 7ACFH0603 Kit code AHC AHN 7ACFH0631 7ACFH0632 G=7ACFH0635 D=7ACFH0634 Price kit 316 316 316 Kit code 7ACTL0486 Price kit 8 Right Kit code 7ACVF0360 7ACVF0361 7ACVF0362 7ACVF0363 7ACVF0364 7ACVF0363 7ACVF0364 Left Kit code 7ACVF0366 7ACVF0367 7ACVF0368 7ACVF0369 7ACVF0370 7ACVF0369 7ACVF0370 Price kit 460 475 486 504 525 504 525 Right Kit code 7ACVF0372 7ACVF0373 7ACVF0374 7ACVF0375 7ACVF0376 7ACVF0375 7ACVF0376 Left Kit code 7ACVF0378 7ACVF0379 7ACVF0380 7ACVF0381 7ACVF0382 7ACVF0381 7ACVF0382 Price kit 460 472 481 512 527 512 527 Right Kit code 7ACVF0384 7ACVF0385 7ACVF0386 7ACVF0387 7ACVF0388 7ACVF0387 7ACVF0388 Left Kit code 7ACVF0390 7ACVF0391 7ACVF0392 7ACVF0393 7ACVF0394 7ACVF0393 7ACVF0394 Price kit 217 227 237 249 265 249 265 Right Kit code 7ACVF0396 7ACVF0397 7ACVF0398 7ACVF0399 7ACVF0400 7ACVF0399 7ACVF0400 Left Kit code 7ACVF0402 7ACVF0403 7ACVF0404 7ACVF0405 7ACVF0406 7ACVF0405 7ACVF0406 Price kit 214 224 232 254 265 254 265 Kit code 7ACVF0486 7ACVF0487 - - - - - Price kit 110 132 n.a. n.a. n.a. n.a. n.a. Kit code - 7ACVF0488 7ACVF0489 7ACVF0491-7ACVF0491 - Price kit n.a. 136 139 162 n.a. 162 n.a. Kit code - - 7ACVF0490 7ACVF0492-7ACVF0492 - Price kit n.a. n.a. 142 166 n.a. 166 n.a. Kit code - - - - 7ACVF0493 7ACVF0495 7ACVF0493 Price kit n.a. n.a. n.a. n.a. 177 175 177 Kit code - - - - 7ACVF0494-7ACVF0494 Price kit n.a. n.a. n.a. n.a. 181 n.a. 181 Kit code 7ACVF0496 7ACVF0497 - - - - - Price kit 161 192 n.a. n.a. n.a. n.a. n.a. Kit code - 7ACVF0498 7ACVF0499 7ACVF0501-7ACVF0501 - Price kit n.a. 205 212 249 n.a. 249 n.a. Kit code - - 7ACVF0500 7ACVF0502-7ACVF0502 - Price kit n.a. n.a. 220 256 n.a. 256 n.a. Kit code - - - - 7ACVF0503 7ACVF0505 7ACVF0503 Price kit n.a. n.a. n.a. n.a. 276 275 276 Kit code - - - - 7ACVF0504-7ACVF0504 Price kit n.a. n.a. n.a. n.a. 282 n.a. 282 CONTROL ACCESSORiES (supplied loose) 20 30 40 50 60 70 80 CMV TBMV TRM-VP TRM-FA PCO AQS AQS OB Fan speed selector for mounting on unit Bulb thermostat with summer/winter manual switch for mounting on unit - action on control valve and fan Remote thermostat with summer/winter manual switch - action on control valve Remote thermostat with summer/winter manual switch - action on control valve and fan Mechanical sensor for automatique change over Régulateur Aquasimp pour montage Aquasimp controller for wall mounting Aquasimp controller for AWC mounting WPT AQS Water probe for Aquasimp TAE20+SEH Electronic thermostat TAE20 + change over sensor EH Relay Electrical heater relay for terminal Kit AQN AQN ACC NIU ENIU FCC controller all configurations supplied loose for Aquafan Aquanet accessories - 6 plugs + 4 jumpers + RCL connector µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet mbms µbms supervisor RCL RCL remote control (supplied loose) IR Rec Wall IR receiver for Aquanet (Aquanet not included) On stock Right Kit code Left Kit code 7ACEL1454 7ACEL1453 Price kit 27 Right Kit code Left Kit code 7ACEL1431 7ACEL1430 Price kit 62 Kit code 7ACEL1444 Price kit 72 Kit code 7ACEL1441 Price kit 61 Kit code 7ACEL1473 Price kit 72 Kit code 7ACEL1546 Price kit 87 Kit code 7ACEL1532 Price kit 100 Kit code 7ACEL1547 Price kit 17 Kit code 7ACEL1452 Price kit 234 Kit code 7ACEL1465 Price kit 36 Kit code 7ACEL1432 Price kit 148 Kit code 7ACEL1492 Price kit 26 Kit code 7ACEL1462 Price kit 27 Kit code 7ACEL1463 Price kit 35 Kit code 7ACEL1449 Price kit 260 Kit code 7ACEL1446 Price kit 43 Kit code 7ACEL1364 Price kit 215 24 25

Fan coil units 230 V Thermal Type ON/OFF Valve 20 30 40 50 60 70 80 AWC AWN AHC AHN 2-way type, one valve for one coil - W2G1 2-way type, two valves for two coils - W2G2 2-way type, two valves for two coils - W2G2 4-way type, two valves for two coils - W4G2 2-way type, one valve for one coil - W2G1 2-way type, two valves for two coils - W2G2 4-way type, one valve for one coil - W4G1 4-way type, two valves for two coils - W4G2 Kit code 7ACFH0555 7ACFH0579 Price kit 115 157 Kit code 7ACFH0558 7ACFH0582 Price kit 213 255 Kit code 7ACFH0561 7ACFH0585 Price kit 184 213 Kit code 7ACFH0564 7ACFH0588 Price kit 351 385 Left kit code 7ACFH0556 7ACFH0580 Right kit code 7ACFH0557 7ACFH0581 Price kit 130 174 Left kit code 7ACFH0559 7ACFH0583 Right kit code 7ACFH0560 7ACFH0584 Price kit 228 272 Left kit code 7ACFH0562 7ACFH0586 Right kit code 7ACFH0563 7ACFH0587 Price kit 215 240 Left kit code 7ACFH0565 7ACFH0589 Right kit code 7ACFH0566 7ACFH0590 Price kit 399 441 ELECTRICAL HEATER (Supplied loose) 20 30 40 50 60 70 80 Inserted into coil Configuration must to be defined in accordance with mounted fan coil 300w 303 322 n.a. n.a. n.a. n.a. n.a. 500w n.a. n.a. 341 n.a. n.a. n.a. n.a. 600w 272 291 n.a. 347 n.a. n.a. n.a. 750w n.a. n.a. n.a. n.a. 369 345 n.a. 900w 343 365 n.a. n.a. n.a. n.a. n.a. 1000w n.a. n.a. 305 n.a. n.a. n.a. n.a. 1200w n.a. 336 n.a. 310 n.a. n.a. n.a. 1500w n.a. n.a. 383 n.a. 328 308 n.a. 1800w n.a. n.a. n.a. 392 n.a. n.a. n.a. 2000w n.a. n.a. 352 n.a. n.a. n.a. n.a. 2250w n.a. n.a. n.a. n.a. 416 390 n.a. 2400w n.a. n.a. n.a. 358 n.a. n.a. n.a. 3000w n.a. n.a. n.a. n.a. 380 356 n.a. On stock 26 27

Chilled water cassette WKW LN STD 4-way chilled water cassette cooling and heating WKW Size 09 LN 12 LN 18 LN 30 LN 45 LN CapacitIEs - 2 PIPE Nominal Total cooling capacity W 1600 / 1900 / 2300 2300 / 2600 / 3500 2800 / 3700 / 4600 4100/5740/7151 5414/7039/9298 Sensible capacity W 1250 / 1500 / 1800 1700 / 2050 / 2900 2150 / 2950 / 3850 3128/4394/5500 4329/5728/7650 Cooling (1) Water flow l/h 280 / 330 / 400 400 / 450 / 600 480 / 640 / 790 708/989/1232 933/1212/1602 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8/11/16 7,5/13,5/19,6 8,0/12,5/20,0 Heating (2) Heating capacity W 2100 / 2500 / 3100 2700 / 3200 / 4500 3300 / 4600 / 5700 5217/7486/9716 6791/8842/11716 CapacitIEs - 4 PIPE Nominal Cooling Capacity: from 2,3 to 10,2 kw Heating Capacity: from 2,2 to 11,6 kw Sizes : 5 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages designed for suspended ceiling integration. 600x600 (9, 12 and 18 models) and 600x1200 formats, (30 and 45 models). Low built-in height: 287 mm. direct access to electrical connection on sliding chassis. integrated valve and electrical connections. 3-speed AC fan motor. Very low operating acoustical levels with new low noise LN versions (9, 12 and 18 models). Coil with hydrophilic fins to improve the condensate flow. fresh air intake. Air distribution in adjacent room. integrated condensate drain lift pump up to 600 mm, (3-top for 9, 12 and 18 models). infra-red remote control version with valve and change-over. galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. Possibility to close one or two discharge flaps. Cleanable synthetic-type air filter. Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) HOTEL HOSPITAL Operating limit for Standard unit Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. AC motor. Selection of 3 speed. Large choice of control: Aquanet control or wall-mounted thermostat. 2-way or 3-way ON/OFF valve. G1 filter. Condensate drain pump. Relay. Fuse holder. ModBus Communication interface board. Design metallic panel with 192 colours and Coanda air diffusion (9-12-18 models). Main Accessories Valve. Aquanet control. Solid ceiling frame. Condensate drain pump. Auxiliary condensate drain pan. Master and slaves control, up to 4 units max. Selection Software Select It. +5 C +70 C (size 09-12-18) +60 C (size 30/45) 15 bars 13 C/15% RH 32 C/70% RH Total cooling capacity W 1600 / 1900 / 2300 2300 / 2600 / 3500 2800 / 3700 / 4600-5716/7925/9887 Sensible capacity W 1250 / 1500 / 1800 1700 / 2050 / 2900 2150 / 2950 / 3850-4324/6185/7655 Cooling (1) Water flow l/h 280 / 330 / 400 400 / 450 / 600 480 / 640 / 790-985/1365/1703 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16-10,5/18,5/28 Heating (3) Water flow l/h 160 / 180 / 210 200 / 220 / 290 290 / 340 / 380-577/658/788 Heating capacity W 1700 / 1900 / 2200 2200 / 2500 / 3335 3300 / 3950 / 4470-6586/7506/8980 Water pressure drop kpa 5 13 28-5,0/6,0/8,0 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/40/50 34/40/50 41/49/57 37,5/46,4/55,2 46,3/53,7/61,6 Sound pressure level db(a) (4) 26/32/42 26/32/42 33/41/49 31,9/40,6/49,3 40,7/48,1/55,6 NR (4) db(a) 20/27/37 20/27/37 28/35/43 29/36/44 35/42/50 FANS (LS/MS/HS) Number 1 1 1 2 2 Airflow m³/h 330/450/720 330/450/720 410/580/830 585/905/1300 790/1080/1560 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230/1/50 Fan consumption - STD W 20/30/50 20/30/50 21/30/46/71 165/180/200 151/170/180 Electrical heater W 1500 1800 2400 4300 5400 WATER CONNECTIONS Type Gas male threaded Cooling coil inches 20/30/50 20/30/50 30/46/71 38/66/100 63/91/140 Heating coil inches 1500 1800 2400 2800 2800 DIMENSIONS Casing (LxWxH) mm 571 x 571 x 287 1171 x 571 x 287 Grille (LxWxH) mm 625 x 625 x 40 1225 x 625 x 40 WEIGHT Unit weight kg 26 28 29 49 55 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) Air: 20 C, Water in: 60 C/50 C. (4) Sound pressure considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. NEW: on stock! Configuration: 2 or 4-pipes, terminal block or IR, with or without 3-way valve, no brand. PRODUCT CODEs 09 LN 12 LN 18 LN 30 LN 45 LN 2 Pipe without valve WKW 9 OG 2T SV WKW 12 OG 2T SV WKW 18 OG 2T SV WKW 30 OG 2T SV WKW 45 OG 2T SV 7OG052044 7OG052048 7OG052052 7SP043188 7SP043189 Price 1460 1557 1619 2685 2777 WKW 9 OG 2T AV WKW 12 OG 2T AV WKW 18 OG 2T AV 2Pipe with 3-w valve 7OG052045 7OG052049 7OG052053 Price 1700 1798 18608 WKW 9 OG 2T IR AV WKW 12 OG 2T IR AV WKW 18 OG 2T IR AV 2Pipe IR with 3-w valve 7OG102028 7OG102029 7OG102030 Price 2141 2239 2301 WKW 9 OG 4T SV WKW 12 OG 4T SV WKW 18 OG 4T SV 4Pipe without valve 7OG052046 7OG052050 7OG052054 Price 1575 1678 1745 WKW 9 OG 4T AV WKW 12 OG 4T AV WKW 18 OG 4T AV 4Pipe with 3-w valve 7OG052047 7OG052051 7OG052055 Price 1678 2159 2226 On stock 28 29

Chilled water cassette WKW LN EC 4-way chilled water cassette cooling and heating Cooling Capacity: from 2,2 to 4,6 kw Heating Capacity: from 2,0 to 5,7 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages HOTEL HOSPITAL designed for suspended ceiling integration 600x600 mm. Low built-in height: 287 mm. direct access to electrical connection on sliding chassis. integrated valve and electrical connections. Low consumption EC fan motor. Very low operating acoustical levels with new low noise LN versions. Coil with hydrophilic fins to improve the condensate flow. fresh air intake. Air distribution in adjacent room. integrated 3-top condensate drain lift pump up to 600 mm. infra-red remote control version with valve and change-over. galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. Possibility to close one or two discharge flaps. Cleanable synthetic-type air filter. Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. EC motor. Selection of 3 speed with ECoSpeed3 board. Large choice of control: Aquanet control or wall-mounted thermostat. 2-way or 3-way ON/OFF valve. G1 filter. Condensate drain pump. Relay. Fuse holder. ModBus Communication interface board. Design metallic panel with 192 colours and Coanda air diffusion (9-12-18 models). Main Accessories Valve. Aquanet control. Solid ceiling frame. Condensate drain pump. Auxiliary condensate drain pan. Selection Software Select It. WKW Size 09 LN 12 LN 18 LN Capacities - 2 PIPE NOMINAL Total cooling capacity W 1600 / 1900 / 2300 2300 / 2600 / 3500 2800 / 3700 / 4600 Sensible capacity W 1250 / 1500 / 1800 1700 / 2050 / 2900 2150 / 2950 / 3850 Cooling (1) Water flow l/h 280 / 330 / 400 400 / 450 / 600 480 / 640 / 790 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 42682 Heating (2) Heating capacity W 2100 / 2500 / 3100 2700 / 3200 / 4500 3300 / 4600 / 5700 Capacities - 4 PIPE NOMINAL Total cooling capacity W 1600 / 1900 / 2300 2300 / 2600 / 3500 2800 / 3700 / 4600 Sensible capacity W 1250 / 1500 / 1800 1700 / 2050 / 2900 2150 / 2950 / 3850 Cooling (1) Water flow l/h 280 / 330 / 400 400 / 450 / 600 480 / 640 / 790 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16 Heating (3) Water flow l/h 160 / 180 / 210 200 / 220 / 290 290 / 340 / 380 Heating capacity W 1700 / 1900 / 2200 2200 / 2500 / 3335 3300 / 3950 / 4470 Water pressure drop kpa 3 / 4 / 5 7 / 9 / 13 28 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34 / 40 / 50 34 / 40 / 50 41/49/57 Sound pressure level (4) db(a) 26 / 32 / 42 26 / 32 / 42 33/41/49 NR (4) db(a) 20 / 27 / 37 20 / 27 / 37 28/35/43 FANS (LS/MS/HS) Number 1 1 1 Airflow m³/h 330 / 450 / 720 330 / 450 / 720 410 / 580 / 830 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 WATER CONNECTIONS DIMENSIONS WEIGHT Absorbed power W 8 / 11 / 26 8 / 11 / 26 9 / 23 / 41 Electrical heater (max) W 1500 1800 2400 Type Gas male threaded Cooling coil inches 1/2" 1/2" 3/4" Heating coil inches 1/2" 1/2" 1/2" Casing (LxWxH) mm 571x571x287 Grille (LxWxH) mm 625x625x40 Unit weight kg 26 28 29 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) Air: 20 C, Water in: 60 C/50 C. (4) Sound pressure considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +70 C (size 09-12-18) +60 C (size 30/45) 15 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 13 C/15% RH 32 C/70% RH 30 31

Chilled water cassette AccessorIes WKW ACCESSORY CODE 09 LN 12 LN 18 LN 30 LN 45LN 3-w valve + condensate tray - 2P 3-w valve + condensate tray - 2P 3-w valve + condensate tray - 4P 3-w valve + condensate tray - 2P Drain Pan - 2P Aux drain pan Drain Pan - 4P Aux drain pan Special frame for solid ceiling Special frame for solid ceiling - - - 7ACFH0051 7ACFH0052 Price - - - 589 589 - - - - 7ACFH0122 Price - - - - 973 7ACTL0083 7ACTL0005 7ACTL0005 Price 132 132 132 7ACTL0083-7ACTL0040 Price 132-132 7ACVF0091A - - Prix 207 - - ACCESSORY REGULATION 09 LN 12 LN 18 LN 30 LN 45LN TRM-VP TRM-FA Remote thermostat with summer/winter manual switch - action on control valve Remote thermostat with summer/winter manual switch - action on control valve and fan Aquanet Aquanet control RCL NIU eniu RCL remote control (supplied loose) µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet µbms µbms supervisor Aquasimp Aquasimp controller for wall mounting WPT pour Aquasimp Water probe for Aquasimp TAE20+SEH Electronic thermostat TAE20 + change over sensor Relay kit M/S relay kit 7ACEL1444 Price 72 7ACEL1441 Price 61 7ACEL1432 Price 148 7ACEL1446 Price 43 7ACEL1462 Price 27 7ACEL1463 Price 36 7ACEL1449 Price 260 7ACEL1546 Price 87 7ACEL1547 Price 16 7ACEL1452 Price 234 7ACEL1207 Price 330 32 33

Chilled water cassette KCO2 1-WAY CHILLED WATER CASSETTE COANDA effect Cooling Capacity: from 1,1 kw to 3,3 kw Heating Capacity: from 1,3 kw to 3,4 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages Innovative technical solution for architectural installations Advance aesthetic and harmonious design Designed for suspended ceiling installation Possible gravity condensate evacuation Optimum coanda effect through uniform airflow Adjustable multidirectionnal diffusers with high induction 5 speed AC fan motor Very low acoustic levels Galvanized steel sheet with acoustical insulation Air filtration HOSPITAL NEW Main Options Electrical heater On-board electronic control Aquanet or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Fresh air intake Condensate drain pump Selection Software Select KCO2. KCO2 Size 60 90 120 Capacities - 2 PIPE (LS/MS/HS) Total cooling capacity W 880 / 1060 / 1500 1370 / 1620 / 2370 1970 / 2840 / 3340 Sensible capacity W 660 / 810 / 1180 1000 / 1190 / 1770 1440 / 2110 / 2510 Cooling (1) Water flow l/h 163 / 196 / 279 253 / 299 / 437 363 / 525 / 617 Water pressure drop kpa 2,4 / 3,3 / 6,1 2,9 / 3,9 / 7,6 6,4 / 12,1 / 16,2 Heating (2) Heating capacity W 1080 / 1330 / 1930 1600 / 1910 / 2860 2300 / 3370 / 4020 Capacities - 4 PIPE (LS/MS/HS) Total cooling capacity W 880 / 1060 / 1500 1370 / 1620 / 2370 1970 / 2840 / 3340 Sensible capacity W 660 / 810 / 1180 1000 / 1190 / 1770 1440 / 2110 / 2510 Cooling (1) Water flow l/h 163 / 196 / 279 253 / 299 / 437 363 / 525 / 617 Water pressure drop kpa 2,4 / 3,3 / 6,1 2,9 / 3,9 / 7,6 6,4 / 12,1 / 16,2 Heating (3) Water flow l/h 79 / 93 / 126 128 / 147 / 202 182 / 247 / 284 Heating capacity W 920 / 1080 / 1470 1490 / 1710 / 2350 2120 / 2870 / 3300 Water pressure drop kpa 1,6 / 2,1 / 3,6 0,9 / 1,2 / 2,0 2,0 / 3,4 / 4,3 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 35/41/52 33/36/48 35/46/52 Sound pressure level (4) db(a) 26/32/43 24/27/39 26/37/43 NR (4) db(a) 22/28/39 20/23/35 22/33/39 FANS (LS/MS/HS) Airflow m³/h 140 / 180 / 280 200 / 240 / 380 290 / 440 / 540 ELECTRICAL (LS/MS/HS) Power supply V / Ph / Hz 230 / 1 / 50 Fan consumption - STD W 16/22/49 24/27/44 27/42/59 Electrical heater W 550 1100 1400 WATER CONNECTIONS Type Gas male threaded Cooling coil inches 1/2" 1/2" 1/2" Heating coil inches 1/2" 1/2" 1/2" DIMENSIONS Casing (LxWxH) mm 592 x 592 x 309 592 x 970 x 309 592 x 1192 x 309 (1) According to Eurovent standard: Air : 27 C BS / 19 C BH, Eau : 7 C/12 C (2) According to Eurovent standard: Air : 20 C, Eau : 70 C/60 C. (3) Sound pressure considering a local attenuation of 9 db for a volume of 100m3 with a reverberation time of 0,5 sec. KCO2 KCO2 60 KCO2 90 KCO2 120 False ceiling integration Orientable diffusor with Coanda effect 7OG0064001AW 7OG0064002AW 7OG0064003AW 2 Pipes Price 1 087 1 381 1 550 7OG0064021AW 7OG0064022AW 7OG0064023AW 4 Pipes Price 1 157 1 495 1 678 Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +80 C 10 bars 34 35

Chilled water cassette KCO2 EC 1-WAY CHILLED WATER CASSETTE COANDA effect Cooling Capacity: from 0,8 kw to 3,8 kw Heating Capacity: from 1 kw to 4,5 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages EC motor with very low consumption Innovative technical solution for architectural installations Advance aesthetic and harmonious design Designed for suspended ceiling installation Possible gravity condensate evacuation Optimum coanda effect through uniform airflow Adjustable multidirectionnal diffusers High induction diffusion grille Very low acoustic levels Galvanized steel sheet with acoustical insulation HOSPITAL NEW Main Options EC motor Electrical heater On-board electronic control Aquanet or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Fresh air intake Condensate drain pump Selection Software Select KCO2. KCO2 EC Size 60 90 120 Capacities - 2 PIPE Capacities - 4 PIPE Cooling (1) (LS/MS/HS) Total cooling capacity W 890 / 1180 / 1560 1460 / 2310 / 3160 1870 / 2780 / 3750 Sensible capacity W 620 / 910 / 1240 1070 / 1730 / 2410 1370 / 2060 / 2830 Water flow l/h 153 / 218 / 291 240 / 428 / 585 346 / 514 / 693 Water pressure drop kpa 2,1 / 4,0 / 6,5 3,2 / 7,3 / 12,6 5,8 / 11,7 / 19,8 Heating (2) Heating capacity W 1020 / 1500 / 2020 1720 / 2790 / 3850 2190 / 3300 / 4540 Cooling (1) (LS/MS/HS) Total cooling capacity W 8920 / 1180 / 1560 1460 / 2310 / 3160 1870 / 2780 / 3750 Sensible capacity W 620 / 910 / 1240 1070 / 1730 / 2410 1370 / 2060 / 2830 Water flow l/h 153 / 218 / 291 240 / 428 / 585 346 / 514 / 693 Water pressure drop kpa 2,1 / 4,0 / 6,5 3,2 / 7,3 / 12,6 5,8 / 11,7 / 19,8 Heating (3) Water flow l/h 75 / 101 / 131 136 / 199 / 259 175 / 243 / 313 Heating capacity W 870 / 1180 / 1520 1580 / 2310 / 3010 2040 / 2820 / 3640 SOUND LEVELS (LS/MS/HS) FANS (LS/MS/HS) ELECTRICAL WATER CONNECTIONS DIMENSIONS (LS/MS/HS) Water pressure drop kpa 1,4 / 2,5 / 3,8 1,0 / 2,0 / 3,1 1,8 / 3,3 / 5,1 Sound power level db(a) 35/46/55 34/46/56 36/48/58 Sound pressure level (4) db(a) 26/37/46 25/37/47 27/39/49 NR (4) db(a) 22/33/42 21/33/43 23/35/45 Airflow m³/h 130 / 205 / 295 215 / 370 / 540 275 / 430 / 620 Power supply V / Ph / Hz 230 / 1 / 50 Absorbed power W 8/14/29 34/46/56 36/48/58 Electrical heater W 550 1100 1400 Type male pas gaz Cooling coil inches 1/2" 1/2" 1/2" Heating coil inches 1/2" 1/2" 1/2" Casing (LxWxH) mm 592 x 592 x 309 592 x 970 x 309 592 x 1192 x 309 1) According to Eurovent standard: Air : 27 C BS / 19 C BH, Eau : 7 C/12 C (2) According to Eurovent standard: Air : 20 C, Eau : 70 C/60 C. (3) Sound pressure considering a local attenuation of 9 db for a volume of 100m3 with a reverberation time of 0,5 sec. KCO2 KCO2 60 EC KCO2 90 EC KCO2 120 EC False ceiling integration Orientable diffusor with Coanda effect 7OG0064201AW 7OG0064202AW 7OG0064203AW 2 Pipes Price 1 485 1 795 1 974 7OG0064221AW 7OG0064222AW 7OG0064223AW 4 Pipes Price 1 559 1 915 2 109 Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +80 C 10 bars 36 37

Hight wall chilled water units HaWair High wall chilled water unit Cooling and heating Cooling Capacity: from 2,2 to 4,7 kw Heating Capacity: from 2,0 to 5,9 kw Sizes : 4 Versions: 2-Pipes Configurations: High Wall Product Avantages Aesthetic design suitable for home and hotel applications. Silent unit for optimum customer comfort. Version with Integrated 3-way valve and IR control. Choice between IR or wall-mounted thermostat. Coil with hydrophilic fins to improve the condensate flow. Light unit for easy installation. Very easy servicing through removable front plate. Cleanable synthetic-type air filter. indoor unit compatible with all Airwell chilled water production units. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) HOTEL +5 C +60 C 15 bars 6 C/15% RH 32 C/70% RH Main Options RC-08A IR control. Terminal block for wall-mounted thermostat. Version with 3-way ON/OFF valve. 3-speed tangential fan motor. Motorized flap. Electro-static anti-bacteria filter. Pipe connectors. Drilling template Main Accessories Valve. Aquanet control. Wall-mounted thermostat. HaWair Size HAW007 HAW009 HWA012 HAW022 CapacitIEs NOMINAL Total cooling capacity W 1650 / 1900 / 2200 1700 / 2000 / 2900 2900 / 3300 / 3600 3400 / 4000 / 4700 Cooling (1) Sensible capacity W 1400 / 1640 / 1870 1500 / 1700 / 2400 2400 / 2650 / 3000 2800 / 3300 / 3700 Water flow l/h 290 / 320 / 400 310 / 360 / 500 490 / 560 / 620 590 / 690 / 810 Water pressure drop kpa 3 / 6 / 10 5 / 10 / 16 20 / 27 / 35 27 / 36 / 50 Heating (2) Heating capacity W 2000 / 2300 / 2900 2050 / 2350 / 3700 3800 / 4300 / 4800 4250 / 4900 / 5850 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 36/40/44 38/42/48 45/48/52 50/54/58 Sound pressure level (4) db(a) 24/32/36 30/34/40 37/40/44 42/46/50 NR (4) db(a) 19/27/31 25/29/35 32/35/39/ 37/41/45 FANs (LS/MS/HS) Number 1 1 1 1 Airflow m³/h 320/380/450 400/500/600 550/650/750 650/750/900 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230/1/50 Fan consumption W 22/26/28 22/26/28 25/28/31 43/47/58 WATER CONNECTIONS Type Femelle pas gaz Coil inches 1/2" 1/2" 1/2" 1/2" DIMENSIONS Casing (LxWxH) mm 845 x 275 x 180 940 x 298 x 200 WEIGHT Unit weight 11 11 13 13 (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) Sound pressure considering a local of 100m³, a reverberation time of 0,5 sec and a distance of 1 m. PRODUCT CODES HaWair 7 IR SV HaWair 9 IR SV HaWair 18 IR SV HaWair 22 IR SV 2 Pipes IR Without valve AWFC-HAW007-A AWFC-HAW009-A AWFC-HAW018-A AWFC-HAW022-A Price 560 608 673 732 - HaWair 9 IR AV - HaWair 22 IR AV 2 Pipes IR With valve - AWFC-HAW009-B - AWFC-HAW022-B Price - 921-1017 HaWair 7 TB SV HaWair 9 TB SV HaWair 18 TB SV HaWair 22 TB SV 2 Pipes Without valve AWFC-HAW007-C AWFC-HAW009-C AWFC-HAW018-C AWFC-HAW022-C Price 506 560 630 684 ACCESSORY CODES TRM-VP Remote thermostat with 7ACEL1444 summer/winter manual switch - action on control valve Price 72 TRM-FA Remote thermostat with summer/winter manual switch - 7ACEL1441 action on control valve and fan Price 61 PCO Mechanical sensor for automatique change over Aquanet Aquanet control - remote RCL NIU eniu µbms Aquasimp RCL remote control (supplied loose) µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet µbms supervisor Aquasimp controller for wall mounting WPT pour Aquasimp Water probe for Aquasimp TAE20 TAE20+SEH SEH W261 W461 Electronic thermostat TAE20 Electronic thermostat TAE20 + change over sensor SChange over sensor for TAE 20 1 valve 2-Pipes 2V/TOR/2T 1 valve 3-Pipes 4V/TOR/2T 7ACEL1473 Price 71 7ACEL1432 Price HT 148 7ACEL1446 Price 43 7ACEL1462 Price 27 7ACEL1463 Price 36 7ACEL1449 Price 260 7ACEL1546 Price 87 7ACEL1547 Price 17 7ACEL1451 Price 193 7ACEL1452 Prix 234 7ACEL1233 Price 47 7ACFH0814 Prix 92 7ACFH0815 Price 154 38 39

Pressure ductable fan coil unit DUCTYS PRESSURE DUCTABLE FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1,2 to 3,3 kw Heating Capacity: from 1,6 to 4,0 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Ceiling concealed Product Avantages Blue fin coil OFFICES EC fan motor with very low consumption. Very low height (223 mm). Ease of installation and maintenance. In-line or same side (U-type) airflow diffusion. Static pressure available up to 100 Pa. Very low operating acoustical levels. Selection of hydraulic and electric service side. Configuration flexibility thanks to modular conception. Various air intake and discharge configuration: rectangular or duct connections. Coil with hydrophilic fins to improve the condensate flow. Extended monobloc condensate drain pan. Pipe locking system. High outlet temperature for an optimal confort. Many aeraulic configurations Operating limit for Standard unit NEW Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE Electrical heater with inserted heating rod On-board electronic control or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Ducted or rectangular plenum for air intake or dischage Fresh air intake Condensate drain pump G2 filter Fuse holder Main Accessories 2-way or 3-way ON/OFF valve Large choice of controls : Electro-mechanic, electronic, on-board or wall-mounted IR control Suspension kit Selection Software Select It. DUCTYS Size Ductys 1500 Ductys 2000 Ductys 2500 CAPACITIES - 2 PIPE CAPACITIES - 4 PIPE Cooling (1) (LS/MS/HS) Total cooling capacity W 1230 / 1700 / 1970 1720 / 2230 / 2460 2450 / 2810 / 3260 Sensible capacity W 1130 / 1540 / 1820 1460 / 1950 / 2250 1990 / 2280 / 2690 Available static pressure Pa 19 / 50 / 80 26 / 50 / 66 32 / 50 / 66 Water flow l/h 210 / 290 / 340 305 / 380 / 430 420 / 480 / 565 Water pressure drop kpa 4 / 7 / 9 8 / 13 / 15 16 / 21 / 28 Heating (2) Heating capacity W 1600 / 2260 / 2790 2410 / 2930 / 3100 3070 / 3600 / 4020 Cooling (1) Heating (3) (LS/MS/HS) SOUND LEVELS (LS/MS/HS) FAN (LS/MS/HS) ELECTRICAL ELECTRICAL CLASS WATER CONNECTIONS DIMENSIONS POIDS Total cooling capacity W 1190 / 1610 / 1920 1670 / 2190 / 2390 2220 / 2730 / 3010 Sensible capacity W 1080 / 1470 / 1750 1420 / 1930 / 2150 1760 / 2200 / 2460 Available static pressure Pa 18 / 50 / 72 25 / 50 / 64 31 / 50 / 55 Water flow l/h 205 / 280 / 330 290 / 380 / 410 380 / 470 / 520 Water pressure drop kpa 4 / 7 / 9 8 / 13 / 15 13 / 20 / 23 Heating capacity W 2230 / 2850 / 3220 3170 / 3460 / 3540 3580 / 4220 / 4540 Water flow l/h 190 / 250 / 280 270 / 300 / 310 310 / 365 / 390 Water pressure drop kpa 6 / 9 / 12 12 / 16 / 17 15 / 21 / 24 Sound power level Ret + Rad (4) db(a) 44 / 52 / 60 50 / 57 / 61 50 / 55 / 61 (LS/MS/HS) Sound power level Dis (4) db(a) 45 / 56 / 62 48 / 57 / 61 50 / 56 / 61 Sound pressure level (5) db(a) 26 / 35 / 42 28 / 36 / 40 32 / 36 / 43 NR (5) 21 / 30 / 37 23 / 31 / 35 27 / 31 / 38 Number 1 1 1 Airflow 2-Pipes m³/h 270 / 400 / 505 370 / 520 / 600 440 / 550 / 640 Airflow 4-Pipes m³/h 265 / 380 / 480 360 / 510 / 575 410 / 525 / 595 Power supply V / Ph / Hz 230 / 1 / 50-60 Fan consumption W 8 / 30 / 60 18 / 47 / 72 26 / 41 / 64 Fan setpoint V 3.8 / 6.0 / 8.2 4.8 / 7.1 / 8.9 3.1 / 3.9 / 4.9 Electrical heater W 600 / 1000 600 / 1000 1000 / 2000 2-Pipes FCEER B B B FCCOP A A A 4-Pipes FCEER B B B FCCOP A A A Type Femelle pas Gaz Cooling coil inches 1/2" 1/2" 1/2" Heating coil inches 1/2" 1/2" 1/2" Casing (LxWxH) mm 581 x 640 x 223 581 x 740 x 223 581 x 840 x 223 kg 16 18 20 Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +60 C 15 bars 5 C/15% RH 32 C/70% RH Performances based on: (1) According to Eurovent standard: Air: 27 C DB / 19 C WB, Water: 7 C/12 C, 50 Pa external static pressure in medium speed. (2) According to Eurovent standard: Air: 20 C, same water flow as in cooling, 50 Pa external static pressure in medium speed. (3) According to Eurovent standard: Air: 20 C, Water: 70 C/60 C, 50 Pa external static pressure in medium speed. (4) According Eurovent standard: Return + radiated / Discharge sound power level given for a unit with 50 Pa external static pressure in medium speed. (5) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Configuration return / discharge: rectangular - rectangular According to Eurovent standard 6/9 (thermal), 6/10 (airflow) et 8/12 (acoustics) 40 41

Pressure ductable fan coil unit VH STD High static pressure ductable fan coil unit COOLING AND HEATING VH STD Size 07 15 18 21 24 27 CapacitIEs - 2 PIPE - Nominal AT 50 Pa Cooling (1) Total cooling capacity W 4560/5500/5810 7080/11930/13990 7860/14430/17560 8290/16130/20180 15170/17240/19720 16780/19400/22640 Sensible capacity W 3270/4150/4470 5220/9610/11890 5590/10840/13660 5780/11690/14940 11110/12790/14890 11830/13780/16240 Water flow l/h 785/950/1000 1220/2055/2410 1354/2486/3025 1430/2778/3476 2613/2970/3400 2890/3342/3900 Water pressure drop kpa 27/39/45 8/20/26 7/20/28 8/29/43 13/17/21 14/18/23 Heating (2) Heating capacity W 5370/7060/7630 8010/14870/18370 8730/17050/21620 9010/18110/23110 18590/21620/25310 19070/22290/26370 CapacitIEs - 4 PIPE - Nominal AT 50 Pa Total cooling capacity W 4180/5020/5300 6560/10460/11990 6950/11570/13500 7930/14760/18100 14050/15790/17810 15220/17300/19790 Cooling (1) Sensible capacity W 2990/3740/4020 4940/8840/10810 5190/9540/11810 5630/10970/13860 10630/12160/14040 11110/12800/14910 Water flow l/h 720/865/913 1130/1800/2065 1200/1993/2325 1366/2540/3118 2420/2720/3068 2622/2980/3410 Water pressure drop kpa 20/27/30 6/13/17 7/17/23 11/35/51 15/19/23 13/17/21 Heating (3) Water flow l/h 725/920/990 1330/2360/2880 1340/2360/2875 1340/2360/2875 2570/2900/3320 2560/2900/3310 Heating capacity W 5890/7470/8050 10800/19190/23380 10890/19190/23370 10890/19190/23370 20880/23600/26950 20860/23590/26920 Water pressure drop kpa 9/14/16 39/109/156 24/66/95 24/66/95 74/93/118 46/58/75 FACTORY SOUND LEVELS (LS/MS/HS) Cooling Capacity: from 2,1 kw to 28,4 kw Heating Capacity: from 3,5 kw to 33,9 kw Sizes : 6 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Ceiling concealed Product Avantages Ease of installation and maintenance. High static pressure avaiable up to 200 Pa. Airflow rate up to 4650 m³/h. Energy saving EC fan motor. Very low operating acoustical levels in low speeds. Selection of hydraulic and electric service side. Configuration flexibility thanks to modular conception. Various air intake configuration: rectangular or duct connections. Coil with hydrophilic fins to improve the condensate flow. g3 filter as standard. Compliant with ERP directive. Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G4 filter in option. Ducted or rectangular plenum for air intake or dischage. Fresh air intake. Double skin insulation for ERP applications. Auxiliary condensate drain pan. Condensate drain pump. Relay. Fuse holder. Individual packaging. Main Accessories Valve. Control. IR control. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage. Selection Software Select It. FANS ELECTRICAL Sound power level (4) db(a) 54/60/63 52/65/72 52/65/72 52/65/72 65/69/72 65/69/72 Sound pressure level (5) db(a) 53/59/61 52/64/71 52/64/71 52/64/71 63/67/71 63/67/71 Sound pressure level (5) db(a) 33/39/42 31/44/51 31/44/51 31/44/51 44/48/54 44/48/54 NR (5) db(a) 27/34/37 27/40/47 27/40/47 27/40/47 40/44/51 40/44/51 (LS/MS/HS) Number 2 2 2 2 2 2 Static pressure kpa 30/50/70 15/50/90 15/50/90 15/50/90 35/50/75 35/50/75 Airflow at 50 Pa m³/h 703/977/1125 960/2112/2830 960/2112/2830 960/2112/2830 2040/2413/2925 2040/2413/2925 (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 50-60 Fan consumption STD W 132/182/222 180/421/675 180/421/675 180/421/675 420/530/870 420/530/870 Electrical heater (max) W 2000 3000 3000 3000 3000 3000 WATER CONNECTIONS DIMENSIONS Type Femelle pas gaz Mâle pas gaz Cooling coil 2-Pipes inches 1/2" 1" 1 1/4" 1 1/4" 1 1/4" 1 1/4" Cooling coil 4-Pipes inches 1/2" 1" 1" 1" 1 1/4" 1 1/4" Heating coil inches 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" Rect-rect LxWxH mm 698 x 1200 x 250 798 x 1380 x 375 798 x 1380 x 375 798 x 1380 x 375 798 x 1500 x 450 798 x 1500 x 450 Circ-Circ LxWxH mm 1014 x 1200 x 250 - - - - - WEIGHT Rect-rect Unit weight kg 42 63 65 67 76 80 Circ-circ Unit weight kg 48 - - - - - (1) Air: 27 C DB/19 C WB, Water in: 7 C/12 C, 50 Pa external static pressure. (2) Air: 20 C, Water in: 50 C, same water flow as in cooling, 50 Pa external static pressure. (3) Air: 20 C, Water in: 70 C/60 C, 50 Pa external static pressure. (4) According Eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed. (5) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +60 C 15 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 42 43

Pressure ductable fan coil unit VH EC High static pressure ductable fan coil unit COOLING AND HEATING Cooling Capacity: 5,5 kw Heating Capacity: 4,2 kw Sizes : 1 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Ceiling concealed Product Avantages FACTORY Ease of installation and maintenance. High static pressure avaiable up to 200 Pa. Airflow rate up to 4650 m³/h. Energy saving EC fan motor. Very low operating acoustical levels in low speeds. Selection of hydraulic and electric service side. Configuration flexibility thanks to modular conception. Various air intake configuration: rectangular or duct connections. Coil with hydrophilic fins to improve the condensate flow. g3 filter as standard. Compliant with ERP directive. Operating limit for Standard unit Conçus & fabriqués en Designed & produced in depuis 1947 Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. Selection of 3 speed. EC motor. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G4 filter in option. Ducted or rectangular plenum for air intake or dischage. Fresh air intake. Double skin insulation for ERP applications. Auxiliary condensate drain pan. Condensate drain pump. Relay. Fuse holder. Individual packaging. Main Accessories Valve. Control. IR control. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage.. Selection Software Select It. FRANCE VH EC Size 07 CapacitIEs - 2 PIPE Nominal AT 50 Pa Total cooling capacity W 4560 / 5500 / 5810 Cooling (1) Sensible capacity W 3270 / 4150 / 4470 Water flow l/h 785 / 950 / 1000 Water pressure drop kpa 27 / 39 / 45 Heating (2) Heating capacity W 5370 / 7060 / 7630 CapacitIEs - 4 PIPE Nominal AT 50 Pa Total cooling capacity W 4180 / 5020 / 5300 Cooling (1) Sensible capacity W 2990 / 3740 / 4020 Water flow l/h 720 / 865 / 913 Water pressure drop kpa 20 / 27 / 30 Heating (3) Water flow l/h 725 / 920 / 990 Heating capacity W 5890 / 7470 / 8050 Water pressure drop kpa 9 / 14 / 16 SOUND LEVELS (LS/MS/HS) Sound power acoustic Aspiration+Ray db(a) 54 / 60 / 63 Sound power level (4) db(a) 53 / 59 / 61 Sound pressure level (5) db(a) 33 / 39 / 42 NR (5) db(a) 27 / 34 / 37 FANS (LS/MS/HS) Number 2 Static pressure Pa 30 /50 / 70 Airflow at 50 Pa m³/h 703 /977 / 1125 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50-60 Fan consumption W 40 / 90 / 121 Set voltage V 3,5 / 6 / 8,9 Electrical heater (max) W 2000 WATER CONNECTIONS Type Gas female threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMENSIONS Rect-rect L x W x H mm 698 x 1200 x 250 Circ-Circ L x W x H mm 1014 x 1200 x 250 WEIGHT Rect-rect Unit weight kg 42 Circ-circ Unit weight kg 48 1) Air: 27 C DB/19 C WB, Water in: 7 C/12 C, 50 Pa external static pressure. (2) Air: 20 C, Water in: 50 C, same water flow as in cooling, 50 Pa external static pressure. (3) Air: 20 C, Water in: 70 C/60 C, 50 Pa external static pressure. (4) According Eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed. (5) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +60 C 15 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 44 45

Pressure ductable fan coil unit AccessorIes DUCTYS AND VH AccessorIEs PRC KS BCA TRM-VP TRM-FA TAE20 TAE20+SEH Mechanical sensor for automatique change over Suspension Kit Bac Condensats Auxiliaire Remote thermostat with summer/winter manual switch - action on control valve Remote thermostat with summer/winter manual switch - action on control valve and fan Electronic thermostat TAE20 Electronic thermostat TAE20 + change over sensor SEH SChange over sensor for TAE 20 AQS WPT AQS RCL µbms NIU ENIU IR Rec Aquasimp control for ceiling concealed Water sond temperature for Aquasimp RCL remote control (supplied loose) µbms supervisor µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet Ceiling concealed IR for Aquanet (Aquanet no included) DUCTYS 1500 DUCTYS 2000 DUCTYS 2500 VH07 VH15 VH18 VH21 VH24 VH27 7ACEL1346 Price 338 7ACFH0820 7ACTL0486 Price 251 9 N/A N/A N/A 7ACTL0096 Price N/A N/A N/A 34 7ACEL1444 Price 72 7ACEL1442 Price 61 7ACEL1451 Price 194 7ACEL1452 Price 234 7ACEL1233 Price 47 7ACEL1546 Price 87 7ACEL1547 Price 17 7ACEL1547 Price 43 7ACEL1450 Price 260 7ACEL1462 Price 27 7ACEL1463 Price 36 7ACEL1364 Price 215 THERMIcs VALVES 230V DT15 DT20 DT25 VH7 VH15 VH18 VH21 VH24 VH27 2V/TOR/2T 2V/TOR/4T 4V/TOR/2T 4V/TOR/4T 2 Pipes - 1 valve for 1 coil 2V/TOR/2T 2 Pipes - 2 valves for 2 coil 2V/TOR/4T 1 Pipe -4 valves for 1 coil 4V/TOR/2T 2 Pipes -4 valves for 2 coil 4V/TOR/4T 7ACFH0816 7ACFH0816 7ACFH0816 7ACFH0621 7ACFH0623 7ACFH0623 7ACFH0624 7ACFH0624 NA Price 86 86 86 178 185 185 254 254 NA 7ACFH0817 7ACFH0817 7ACFH0817 7ACFH0627 7ACFH0629 7ACFH0629 7ACFH0630 7ACFH0630 NA Price 165 165 165 317 327 327 400 400 NA 7ACFH0818 7ACFH0818 7ACFH0818 7ACFH0609 7ACFH0611 7ACFH0611 7ACFH0612 7ACFH0612 NA Price 192 192 192 254 254 254 316 316 NA 7ACFH0819 7ACFH0819 7ACFH0819 7ACFH0615 7ACFH0617 7ACFH0617 7ACFH0618 7ACFH0618 NA Price 355 355 355 439 439 439 502 502 NA 46 47

Commercial Air conditioning VPN FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1.8 to 12.6 kw Heating Capacity: from 3.5 to 20.0 kw Sizes: 9 Versions: 2-Pipes 2-Pipes/2-Wires Configurations: Horizontal concealed Product Avantages Ease of installation. 3-speed centifugal fan motor. Airflow rate between 170 and 2380 m³/h. 3-row coil for optimized cooling performances. Coil with hydrophilic fins to improve the condensate flow. Extended drain pan. Operating limit for Standard unit Main Options Electrical heater. Ducted plenum for air intake. Main Accessories Control. Cooling (1) VPN Size 200 300 400 500 600 800 1000 1200 1400 CAPACITIES Water flow l/h 334 569 643 915 950 1238 1565 1809 2054 Total cooling capacity W 1823 3206 3626 5154 5400 7530 9000 10800 12600 Water pressure drop kpa 2.9 9.1 12.1 22.5 23.2 10.6 18.2 25.3 36.4 Heating (2) Heating capacity W 3515 5519 6558 8795 9321 13108 15320 16569 20021 SOUND LEVELS - High Speed Sound pressure level - 12 Pa db(a) 35 36 41 43 45 46 48 48 50 Sound pressure level - 30 Pa db(a) 39 40 43 45 47 48 50 52 53 Sound pressure level - 50 Pa db(a) 40 44 46 47 49 50 52 54 55 FANS (LS/MS/HS) Motor Number 1 1 1 1 1 2 2 2 2 Blower Number 1 2 2 2 2 3 3 4 4 Airflow m³/h 170/255/340 278/401/525 336/525/680 445/668/890 530/780/1020 700/1050/1400 870/1395/1700 1020/1530/2040 1190/1785/2380 ELECTRICAL - High Speed Power supply V/Ph/Hz 230 / 1 / 50 Power consumption - 12 Pa W 30 37 56 76 96 131 152 189 228 Power consumption - 30 Pa W 44 59 72 87 108 167 190 212 253 Power consumption - 50 Pa W 49 66 84 100 118 174 210 253 300 WATER CONNECTIONS Water connection inches G3/4" Drain connection inches G3/4" DIMENSIONS L x W x H mm 665x565x248 845x565x248 915x565x248 1050x565x248 1050x565x248 1505x565x248 1505x565x248 1755x565x248 2055x565x248 WEIGHT Unit weight kg 16 19.5 20.5 22.5 22.5 35 35 41 44.5 (1) Air: 27 C DB / 19,5 C WB, Water: 7 C/12 C (2) Air: 21 C, Water in: 60 C, same water flow as in cooling. product codes: on request OPTIONS Electrical Heater ACCESSORY CODE TRM-VP Remote thermostat withsummer/winter manual switch - action on control valve Kit code 7ACEL1444 TRM-FA Remote thermostat withsummer/winter manual switch - action on control valve and fan Kit code 7ACEL1441 PCO Mechanical sensor for automatique change over Kit code 7ACEL1473 AQS Aquasimp controller for wall mounting Kit code 7ACEL1546 AQS OB Aquasimp controller for AWC mounting Kit code 7ACEL1532 WPT AQS Water probe for Aquasimp Kit code 7ACEL1547 TAE20 Electronic thermostat TAE20 Kit code 7ACEL1451 TAE20+SEH Electronic thermostat TAE20 + change over sensor Kit code 7ACEL1452 SEH Change over sensor for TAE 20 Kit code 7ACEL1233 AQN FCC controller all configurations supplied loose for Aquafan Kit code 7ACEL1432 AQN ACC Aquanet accessories - 6 plugs + 4 jumpers + RCL connector Kit code 7ACEL1492 NIU µbms compatible communication board NIU for Aquanet Kit code 7ACEL1462 ENIU Modbus communication board eniu for Aquanet Kit code 7ACEL1463 mbms µbms supervisor Kit code 7ACEL1449 RCL RCL remote control (supplied loose) Kit code 7ACEL1446 IR Rec Wall IR receiver for Aquanet (Aquanet not included) Kit code 7ACEL1364 Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 16 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 48 49

Control system range for fan coil units A full range dedicated to your needs Electro-Mechanical Control Electronic Control CMV TBMV TRM-VP TRM-FA TAE 20 AQUASIMP AQUANET or RCL Wired remote control Advanced Control Performances. Temperature sensor included. display of temperature. Selection of the speed. LED - On/Off & Default. RC7 Infra red remote control Advanced Control Performances. display of temperature. Selection of the speed. LED - On/Off & Default. UMBS System CMV TBMV TRM-VP TRM-FA TAE 20 AQUASiMP AQUANET 2 Pipes Reversible + valves 2 Pipes / 2 Wires + valves 2 Pipes / 2 Wires reversible + valves 4 Pipes + valves Action No valves (Not recommended) Change over Manual Manual Manual Automatic Manual or automatic Manual or automatic Fan speed selection Manual Manual Manual Manual Manual Manual or automatic Fan action Continuous Fan (1) Cycling fan (2) Continuous fan (1) Cycling fan (2) Master/slaves Continuous (1) or cycling fan (2) Continuous (1) or cycling fan (2) Up to 10 slaves with no additional interface Continuous or cycling fan (2) Up to 15 slaves with only one control device. Mounted Wall mounted Factory fitted Factory fitted 7ACEL1444 7ACEL1441 7ACEL1452 on AWC 7ACEL1432 7ACEL1546 on Aquafan range on Aquafan range 7ACEL1532 Price E 72 61 234 87 100 148 ((1) Continuous Fan: Fan runs continuously in cooling or heating mode. (2) Cycling Fan: Fan stops and starts with temperature demand. Carte NIU Managing up to 15 different zone, with a maximum of 80 units. Programming and control of the temperature indivdualized by zone. Weekly programmation. 2 daily ranges configurable by area. Carte e-niu - MODBUS This card allow the connection to a Modbus communication protocol. The NIU card gives an individual adress to each fan coil inside the communication bus system. manual programmation with DIP Switch. 50 51

Water Source Heat Pumps 52 53

SElection GUIDE FOR WATER HEAT PUMPS 0KW 5 10 15 20 25 30KW EFTYS HOTEL OFFICES EFTYS 2000 EFTYS 2500 EFTYS 3000 2 kw 2,4 kw 3 kw NR 32 at MS NR 34 at MS NR 37 at MS 452-m³/h at HS 503-m³/h at HS 605-m³/h at HS 50Pa EC LxPxW : 900x530x239 LxPxW : 900x530x239 LxPxW : 900x530x239 CWAR 2000 1,9 kw NR 37 at MS 400-m³/h at HS LxPxW : 1138x251x821 CWAR HOTEL OFFICES CWAR 2500 CWAR 3000 2,1 kw 2,7 kw NR 38 at MS NR 40 at MS 460-m³/h at HS 510-m³/h at HS N/A EC* LxPxW : 1138x251x821 LxPxW : 1138x251x821 0KW 5 10 15 20 25 30KW HRW019 5,3 kw NR 42 at MS 1250 m³/h at HS >50Pa LxPxW : 900x600x439 HRW027 7,4 kw NR 44 at MS 1185 m³/h at HS >50Pa LxPxW : 1050x660x460 HRW030 8,7 kw NR 43 at MS 1490 m³/h at HS >100Pa LxPxW : 1050x660x460 HRW036 10,1 kw NR 44 at MS 1580 m³/h at HS >100Pa LxPxW : 1250x705x513 HRW SHOPPING HRW042 HRW048 11,4 kw 12,9 kw NR 44 at MS NR 47 at MS 2040 m³/h at HS 2750 m³/h at HS >100Pa >100Pa N/A LxPxW : 1250x705x513 LxPxW : 1250x705x513 HRW060 14,3 kw NR 47 at MS 2840 m³/h at HS >100Pa LxPxW : 1250x705x513 HRW072 17,1 kw NR 48 at MS 3570 m³/h at HS >100Pa LxPxW : 1250x705x513 HRW096 21,7 kw NR 56 at MS 4700 m³/h at HS >100Pa LxPxW : 1680x955x770 HRW0120 30 kw NR 57 at MS 5600 m³/h at HS >200Pa LxPxW : 1680x955x770 *On request Total cooling capacity at HS, Eurovent conditions. ideal Solution FOR refurbishment, AND R22 UNITS replacement, AS WELL AS FOR NEW APPLICATIONS. Advance scroll technology REFRIGERANT OZONE FRIENDLY TECHNOLOGY AND RELIABILITY Santard protective devices: Flow switch/pressostat on hydraulic circuit HP pressure switch LP pressure switch Fuse holder Rotary or scroll hermetic compressor Energy saving EC fan motor 54 55

Water Source Heat Pump STORM 2 Electronic control system ADVANCED FUNCTIANILITIES: Modbus communication as a standard 0-10 V output to control EC motor, 100% modulated Fault reports of eight different possible machine faults Infra red remote control RC07 Four different operating modes for water source heat pumps by selecting the following systems : Thermodynamic cooling and heating operation (RC). Thermodynamic cooling and heating operation or heating operation with an additional electric heater (SH). Thermodynamic cooling operation and electrical heating operation (RH). Thermodynamic cooling operation only (ST). Product Avantages Measurement of the room air temperature Anti-short cycle to protect the compressor Variable sequential start-up function avoiding a power surge Emergency shut-down / stand-by / night setback Automatic HP reset pressure and/or lack of water flowrate Automatic BP reset pressure Défaut isotherme moteur ventilateur Anti-freeze safety function Low temperature limit in coolong/heating mode High temperature limit in coolong/heating mode Antifreeze default in cooling mode Managing of motorized water valves Managing of Master/slave Main functions: Advanced Control Performances. Temperature sensor included. display of temperature. Selection of the speed. LED - On/Off & Default. Remote control RCL Main functions: Digital display On/Off. Selection of the working mode. Display of the room temperature. Display of the room temperature. Selection of the speed of the fan. A keypad lock function is also available. Display LED which shows the operating status of the water source heat pump. Master/slaves control up to 10 units with only one remote control Mini central supervisor UMBS Main functions: Managing up to 15 different zone, with a maximum of 80 units. Programming and control of the temperature indivdualized by zone. Weekly programmation. 2 daily ranges configurable by area. 56 57

Water Source Heat Pump EFTYS WATER SOURCE HEAT PUMP Cooling Capacity: from 1,9kW to 3,0kW Heating Capacity: from 2,7kW to 3,6kW Refrigerant : HFC 407C Sizes : 3 models, 1 casings Versions: RC : cooling and heating ST : cooling only SH : cooling and heating or electric heating RH : cooling and electric heating Configurations: Horizontal concealed installation Product Avantages OFFICES HOTEL NEW A coaxial heat exchanger robust in presence of loaded water. An extended working range +9 to +48. High energetical performances, with EC motor and high COP/EER. Coil at the oultet to avoid the installation of a siphon. Stand-alone STORM2 electronic control with ModBus Communication. Easy access to components through wide removable panels. Many aeraulic and hydraulic configuration to easily replace the unit alread on site. Extended working range through coaxial heat exchanger. Acoustical insulation and compressor isolated and mounted on spring to an optimal acoustical comfort. Anti-corrosion treated drain pan. Low height < 240mm. Conçus & fabriqués en Designed & produced in depuis 1947 Main Options G2/ M1 filter Electrical heater Quick connector General alarm dry contact Circuit breaker Front or lateral ducted plenum for air discharge Fresh air intake Individual packaging Main Accessories FRANCE Room sensor Flow switch for low waterflow protection Motorized water valve µbms mini-supervision station RCL remote control D E EFTYS Size 2000 2500 3000 CAPACITIES Total cooling capacity (1) W 2057 2405 2983 Sensible cooling capacity (1) W 1686 1983 2346 Heating capacity (1) W 2706 2997 3558 PERFORMANCES COP (1) 4,12 4,17 4,3 FANS WATER CONNECTIONS EER (1) 3,88 4,13 3,85 Nominal Airflow m³/h 452 503 605 Air filter Number / Efficiency 1 / G2 1 / G2 1 / G2 Air filter Dimensions / Thickness mm 225 x 365 / 20 225 x 365 / 20 225 x 365 / 20 Nominal water flow l/s 0,116 0,127 0,173 Cutoff water flow vs nominal water flow (2) % 43 39 29 WPD at nominal water flow kpa 11 13 23 WPD at nominal water flow with valve kpa 27 30 44 Hydraulic connections inches Male type ISO G 1/2" INT Condensate outlet - external ø mm 16 16 16 ELECTRICAL Power supply V / Ph / Hz 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 Power input - cooling mode (3) W 595 648 879 Power input - heating mode (3) W 722 785 932 Electrical heater (4) W 1200 1600 2000 Fan maximum current (ESP=0Pa) A 0,85 0,85 1,4 Compressor nominal current A 2,8 3,0 4,0 Compressor starting current A 16 16 18,9 SOUND LEVELS Sound power level intake+rad (5) db(a) 55/57/59 56/58/60 56/58/62 Sound power level Discharge (5) db(a) 53/55/56 54/56/58 58/61/65 Sound pressure level (6) db(a) 34/36/38 35/37/39 37/40/44 NR (6) db(a) 30/32/34 31/34/36 34/37/42 DIMENSIONS L x W x H mm 900x530x239 900x530x239 900x530x239 WEIGHT Unit weight kg 48 48 48 (1) Performances given at nominal conditions. Cooling mode: Tair=27 C, Twater=30 C & Heating mode: Tair=20 C, Twater=20 C. (2) Protection by flow switch (accessory). - (3) Absorbed power (compressor + fan) at nominal conditions. (4) Electric heating coil is an optional feature available on SH & RH versions. - (5) Sound power level considering 50Pa available static pressure in high speed, in-line unit configuration with filter. - (6) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Coaxial heat exchanger Compressor on springs FB FA SA F Operating limit for Standard unit Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 18 C Max 45 C Min 9 C Max 32 C Min 21 C db / 15 C wb Max 32 C db / 23 C wb Min 15 C Max 25 C 31 bars FC1 FC2 SB Flexibilty of configuration SC1 SC2 NEW : ON STOCK! DESCRIPTION PRICE EFTYS 2000 7OG093001 3080 EFTYS 2500 7OG093002 3110 EFTYS 3000 7OG093003 3223 Configuration of the units on stock Brand Wesper Version Reversible Control Storm2 Remote control RCL Air filter G2/M1 Air inlet Front/ Rectangular: FA Air outlet Front 1 x ø 200 mm (E) Packaging Individual 58 59

Water Source Heat Pump AccessorIes - Supplied loose EFTYS 2000 EFTYS 2500 EFTYS 3000 Motorized water valve Water flow switch Inlet plenum kit 7ACFH0500 Price 236 7ACFH0821 Price 72 7ACFH0566 Price 236 AccessorIes regulation - Supplied loose EFTYS 2000 EFTYS 2500 EFTYS 3000 RCL remote control Supervisor - µbms 7ACEL1446 Price 43 7ACEL1449 Price 260 60 61

Water Source Heat Pump HRW WATER SOURCE HEAT PUMP Cooling Capacity: from 5,3 to 30 kw Heating Capacity: from 5,8 à 38,1 kw Refrigerant : HFC 407C Sizes : 10 models, 4 casings Versions: RC : cooling and heating ST : cooling only SH : cooling and heating or electric heating RH : cooling and electric heating Configurations: Horizontal concealed installation Product Avantages SHOPPING High efficiency horizontal units with high COP. 5 optimized compact casing. Easy access to components through wide removable panels. in-line or perpenducular air blowing. Brazed stainless steelplate heat exchanger for improved efficiency. flow switch for antifreeze protection as standard. Bi-flow thermostatic expansion valve as standard. Anti-corrosion treated drain pan. float-type safety system to protect agains condensate overflow. Stand-alone STORM electronic control with RCL remote control. Conçus & fabriqués en Designed & produced in depuis 1947 Main Options RCW-2 mini-supervision station. ModBus Communication interface board. 3-speed direct drive fan motor (up to 17 kw) or beltdriven fan with variable pitch pulley (above 17kW). G2 filter as standard, G3 in option*. 15 mm thick thermal and acoustical insulation. M1-class fire insulation. Electrical heater. Motorized water valve. General alarm dry contact. disconnect switch*. Front or lateral ducted plenum for air intake*. Fresh air intake. Individual packaging*. * Available on some models. Main Accessories Room sensor. FRANCE HRW Size 019 027 030 036 042 048 060 072 CapacitIEs Total cooling capacity W 5278 7419 8691 10138 11366 12965 14344 17174 Sensible cooling capacity W 4257 5824 6315 7278 8849 10051 10988 13536 Heating capacity W 5826 8342 9759 11036 14422 14904 16147 21500 FANS Nominal Airflow m³/h 1250 1185 1490 1580 2040 2750 2840 3570 Motor power W 145 145 210 245 320 550 550 550 Fan speeds Nbr 3 3 3 3 3 3 3 3 Air filter Number/Efficiency 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 Air filter Dimensions/Thickness mm 365x300/25 365x300/25 385x350/25 385x350/25 450x440/25 450x440/25 450x440/25 450x440/25 WATER CONNECTIONS Plate heat exchanger Nbr 1 1 1 1 1 1 1 1 Nominal water flow (1) l/s 0,256 0,428 0,49 0,564 0,72 0,784 0,93 1,09 Cutoff water flow vs nominal water flow % 50 50 47 45 39 38 35 41 WPD at nominal water flow (1) kpa 13 17 23 25 33 34 40 61 WPD at nominal water flow with valve (6) kpa 16 23 33 39 55 60 77 112 Hydraulic connections inches ISO G 3/4" INT Condensate outlet - external ø mm 19 19 19 19 19 19 19 19 REFRIGERANT CIRCUIT Number of circuit 1 1 1 1 1 1 1 1 Compressor type Rotatif Scroll Scroll Scroll Scroll Scroll Scroll Scroll ELECTRICAL Power supply V/Ph/Hz 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 Power input - cooling mode (4) W 1557 2118 2658 3044 3584 4200 4989 6280 Power input - heating mode (4) W 1611 2332 2983 3460 3920 4300 5150 7347 Electrical heater W 2250 3750 3750 4500 5500 6500 7500 9000 Fan maximum current (ESP=0Pa) (7) A 1,5 1,5 2,6 2,4 3,55 4,7 4,7 6,9 Compressor nominal current A 6,6 3,7 4,5 5,4 5,7 7 7,5 10,6 Compressor starting current A 33 32 40 46 51,5 54 65,5 101 SOUND LEVELS Sound power level (8) db(a) 51/54/58 54/56/57 53/54/57 53/56/58 54/56/58 55/59/63 55/59/63 57/60/63 Sound pressure level (9) db(a) 44/47/51 47/49/50 46/47/50 46/49/51 47/49/51 48/52/56 48/52/56 50/53/56 NR (9) db(a) 39/42/46 42/44/45 41/43/45 41/44/46 42/44/46 43/47/49 43/47/49 45/48/51 DIMENSIONS LxWxH mm 900x600x439 1050x660x460 1050x660x460 1050x660x460 1250x705x513 1250x705x513 1250x705x513 1250x705x513 WEIGHT Unit weight kg 80 100 100 112 133 140 144 149 ACCESSORIES HRW 019 HRW 027 HRW 030 HRW 036 HRW 042 HRW 048 HRW 060 HRW 072 7ACEL1446 RCL remote controller** Price 51 µbms 7ACEL1449 Price 260 (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 db. * Only with return air plenum. ** one RCL is delivery with unit as standard with size 19 to 120. Operating limit for Standard unit HRW 19-72 HRW 96-120 Water inlet temperature Cooling Min 18 C 20 C Max 44 C 48 C Heating Min 13 C Max 34 C Return Air temperature Cooling Min 21 C BS/15 C BH Max 38 C BS/28 C BH 38 C BS/28 C BH Heating Min 15 C Max 27 C 25 C Maximum operating pressure 31 bars NEW: en stock! Configuration : Reversibel, summer/winter on ligne, Wesper, Filter G2/M3, remote RCL CODES HRW 019 HRW 027 HRW 030 HRW 036 HRW 042 7OG091030 7OG091071 7OG091032 7OG091033 7OG091033 Price 3817 4370 4701 4965 5345 CODES HRW 48 HRW 60 HRW 72 HRW 96 HRW 120 7OG091036 7OG091035 7OG091072 7OG091073 7OG091074 Price 5678 6443 7159 8527 11094 62 63

Water Source Heat Pump HRW Size 096 120 CAPACITIES Total cooling capacity W 21743 29951 Sensible cooling capacity W 17986 24413 Heating capacity W 26637 38109 FANS Nominal Airflow m³/h 4700 5600 Motor power W 1100 1500 Fan speeds Nbr - - Air filter Number/Efficiency 2/G2 2/G2 Air filter Dimensions/Thickness mm 620x650/25 620x650/25 WATER CONNECTIONS Plate heat exchanger Nbr 1 1 Nominal water flow (1) l/s 1,35 1,78 Cutoff water flow vs nominal water flow % 44 30 WPD at nominal water flow (1) kpa 55 80,5 WPD at nominal water flow with valve (6) kpa 133 250 Hydraulic connections inches ISO G 1 1/4" Condensate outlet - external ø mm 22 22 REFRIGERANT CIRCUIT Number of circuit 1 1 Compressor type Scroll Scroll ELECTRICAL Power supply V/Ph/Hz 400/3+N/50 400/3+N/50 Power input - cooling mode (4) W 6317 8547 Power input - heating mode (4) W 7895 10224 Electrical heater W 13000 16000 Fan maximum current (ESP=0Pa) (7) A 2,5 4,1 Compressor nominal current A 11,4 14,8 Compressor starting current A 111 118 SOUND LEVELS Sound power level (8) db(a) 68 69 Sound pressure level (9) db(a) 61 62 NR (9) db(a) 56 57 DIMENSIONS LxWxH mm 1680x955x770 1680x955x770 WEIGHT Unit weight kg 253 262 ACCESSORIES HRW 96 HRW 120 RCL remote controller** 7ACEL1446 Price 51 µbms 7ACEL1449 Price 260 (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 db. 64 65

Commercial Air conditioning EWH WATER SOURCE HEAT PUMP Cooling Capacity: from 3.9 to 43 kw Heating Capacity: from 4.3 to 58 kw Refrigerant: R410A Size: 11 models, 7 casings Configurations: Horizontal concealed installation R410A EWH Size 04 05 06 07 10 13 15 22 30 38 45 CAPACITIES Total cooling capacity kw 4.01 5.55 6.63 7.48 10.56 14.86 15.88 21.50 28.60 37.50 43.00 Heating capacity kw 3.90 5.44 6.49 7.33 10.56 14.86 15.88 21.50 28.60 37.50 43.00 VENTILATION Nominal Airflow m³/h 800 950 1100 1260 2030 2500 2650 4000 5200 7000 8000 External static pressure Pa 30 80 120 150 HYDRAULIC CIRCUIT Water side heat exchanger type Coaxial Nominal water flow (1) m³/h 0.85 1.17 1.46 1.61 2.12 3.1 3.4 4.8 6.4 8.3 9.5 WPD at nominal water flow (1) kpa 29 16.3 23.9 31.5 43.8 33.7 35.3 60 42 54 85 Hydraulic connections inches Rc 3/4 R 1-1/4 Condensate outlet - external ø inches G3/4 G1 REFRIGERANT CIRCUIT Refrigerant type R410A Compressor type Rotary Scroll ELECTRICAL Power supply V/Ph/Hz 230/1/50 400/3N/50 Power input - cooling mode W 982 1389 1734 1930 2330 3750 4070 5500 7400 9530 11150 Power input - heating mode W 1085 1496 1849 2122 2330 4400 4700 6100 8600 11050 13190 SOUND LEVELS Sound pressure level db(a) 39/40/41 41/42/43 42/43/44 43/44/45 45/46/47 46/47/48 47/48/49 50 52 55 57 DIMENSIONS L x W x H mm 830x531x382 1024x592x436 1124x650x510 1313x747x512 1376x852x592 1808x1100x720 2059x1110x737 WEIGHT Unit weight kg 57 82 84 88 111 155 158 180 330 370 380 Product Avantages High efficiency horizontal units with high COP. Environment-friendly R410A refrigerant. fitted with high and low pressure switches, refrigerant leakage and water temperature protections. Stand-alone, local or centralized control. Easy installation and servicing. Low sound level. Operating limit for Standard unit Main Accessories Wired remote control Wireless remote control Master control Network board 15m communication link 12V power supply RS485/RS422 adaptor board Data zone control PC monitoring tool (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB. water In/Out: 30/35 C (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB. water In/Out: 20/35 C PRODUCT CODES: on request ACCESSORY CODE 04 05 06 07 10 13 15 22 30 38 45 Wired Remote controller C03027600 C03027700 Wireless Remote controller 467240022 Receiver Assembly C03027400 SYSTEM: GROUP CONTROL Network board C03542000 Master Controller C03541900 Wire communication 15 m C03540210 Power supply Box 12V C03543000 Wired Remote controller C03027600 C03027700 Wireless Remote controller 467240022 Receiver Assembly C03027400 SYSTEM: CENTRAL CONTROL WITH PC Network board C03542000 Transfer Card adapter RS485/232 C03546201 Zone data collect controller C03542100 PC Monitor tool C03546202 Wired Remote controller C03027600 C03027700 Wireless Remote controller 467240022 Receiver Assembly C03027400 Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 10 C Max 40 C Min 10 C Max 30 C Min 16 C Max 32 C db/23 C wb Min 15 C Max 27 C 35 bars 66 67

Water Source Heat Pump CW - AR WATER SOURCE HEAT PUMP COOLING AND HEATING Cooling Capacity: from 1,9 to 2,7 kw Heating Capacity: from 2,4 to 3,2 kw Refrigerant : HFC 407C Sizes : 3 models Versions: CAR: standard with cabinet CARB: low height with cabinet nu: standard without cabinet nub: low height without cabinet Configurations: Vertical console cabinet Vertical concealed without cabinet Product Avantages OFFICES HOTEL High efficiency vertical units with high COP. Harmonuous and aesthetic RAL9010 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. Low consumption EC fan motor or 3-speed AC fan motor. Stand-alone STORM electronic control with RCL remote control. Brazed stainless steelplate heat exchanger for improved efficiency. Easy access to components through front panel. Ease of installation through selection of service side. direct access to Schrader valves (HP & BP). flow switch for antifreeze protection as standard. Anti-corrosion treated drain pan. Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE RCW-2 mini-supervision station. ModBus Communication interface board. L/R Lateral, back or bottom hydrualic connections. L/R lateral electrical connection. G2 filter. 15 mm thick thermal and acoustical insulation. LONWorks control. bottom return air with feet or front air intake. HP & BP pressure switches. General alarm dry contact. Disconnect switch. Thermostat. CW-AR Size 07 09 12 Capacities Total cooling capacity W 1942 2136 2743 Sensible cooling capacity W 1526 1775 2340 Heating capacity W 2431 2542 3156 VENTILATION Nominal Airflow m³/h 400 460 510 Motor power W 75 75 75 Fan speeds Nbr 3 3 3 Air filter Number/Efficiency 1/G2 Air filter (Front) Dimensions/Thickness mm 660x205/6 Air filter (Bottom) Dimensions/Thickness mm 595x187/6 WATER CONNECTIONS Plate heat exchanger Nbr 1 Nominal water flow (1) l/s 0,119 0,133 0,171 Cutoff water flow vs nominal water flow % 44 40 31 WPD at nominal water flow (1) kpa 5 3,4 12 Hydraulic connections inches ISO G 1/2" INT Condensate outlet - external ø mm 15x20 REFRIGERANT CIRCUIT Number of circuit 1 Compressor type Rotatif ELECTRICAL Power supply V/Ph/Hz 230/1/50 Power input - cooling mode (4) W 598 647 892 Power input - heating mode (4) W 710 720 954 Fan maximum current A 0,2 0,25 0,3 Compressor nominal current A 2,8 3 4 Compressor starting current A 16 16 18,9 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 49/50/51 50/51/53 51/53/54 Sound pressure level (5) db(a) 41/42/43 42/43/45 43/45/46 NR (5) db(a) 36/37/38 37/38/40 38/40/41 DIMENSIONS (LxWxH) Console (STD) (6) mm 1138x251x821 Concealed (STD) (6) mm 1086x229x769 WEIGHT Console (STD) kg 70 73 75 Concealed (STD) kg 55 58 60 (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Sound pressure considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. (6) Feet included. Operating limit for Standard unit Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 23 C Max 42 C Min 12 C Max 34 C Min 21 C BS/15 C BH Max 32 C BS/23 C BH Min 15 C Max 27 C 3 bars 68 69

Direct Expansion Range POWER & robustness IN ALL conditions XAR + UC R407C Piston Electromecanical direct expansion range AIR COOLED CONDENSING UNIT 10/55 kw 19/83 kw 12/83 kw FACTORY R407C Scroll Regulation CAC FACTORY CDN R407C Scroll Regulation CAC FACTORY DK DN WATER COOLED CONDENSING UNIT R407C Piston Electromecanical 8/96 kw FACTORY XAO CDN REFRIGERANT OZONE FRIENDLY R410A A RANGE SPECIALLY DEVELOPED for ROBUSTNESS: Weather resistant casing made of heavy gauge galvanized steel coated with powder-based epoxy paint RAL 9001. Wide operating limits. High and low operating temperature with fan speed controller. Easy access to technical compartment and to main components. Compressor fitted with crankase heater and mounted on rubber pads. And flexibility with several versions to fit any of your requirements such as acoustical with: - Basic Low Noise version - Extra Low Noise version - Special Inverter Fan version Or refrigerant: - BAZ as standard version - BAC: BAZ with suction accumulator - BAL: BAC with liquid receiver Reliability with Proven TechnologY Standard protective devices: Flow switch/pressostat on hydraulic circuit HP pressure switch LP pressure switch Fuse holder Scroll hermetic compressor + crankcase heater Fan speed controller PRODUCTION SITES OPTIMIZED TO SATISFY YOUR NEEDS Lean Manufacturing Kaizen concept Built-to-order Fan with variable pitch pulley Remote controller Electro-mechanical controller 70 71

Direct Expansion DK DN AIR-AIR SPLIT SYSTEM COOLING AND HEATING Cooling Capacity: from 12 to 83 kw Heating Capacity: from 12,4 to 83,8 kw Réfrigérant : R407C Sizes : 12 Configurations: Packaged Split system Product Avantages Weather resistant casing with external panels coated with powder-based epoxy paint colour RAL 9001. Indoor centrifugal fan units for duct netwrok connection. High static pressure available. Multi-position architecture for horizontal or vertical mounting (acc. to models). Compact, top discharge outdoor fan units. Low noise axial fan. Scroll compressor with crankcase heater. Electrical, refrigeration and thermal protection devices. Phase controller. External HP and LP pressure taps. Frame and air filter supplied. COOLING MODE Minimum indoor air temperature Maximum indoor air temperature Minimum outdoor air temperature/with all-season kit Maximum outdoor air temperature HEATING MODE Minimum outdoor air temperature Maximum outdoor air temperature Température maxi de l air extérieur NEW: Conform with ERP directive FACTORY Operating limit for Standard unit 21 C BS/15 C BH 32 C BS/23 C BH 15 C BS/-10 C 46 C BS 27 C BS -10 C 24 C BS/18 C BH Conçus & fabriqués en Designed & produced in depuis 1947 Main Options Factory-fitted low ambient temperature control to ensure cooling operation down to -10 C outdoor temperature (All-season). Main Accessories FRANCE Electric heater. Programmable controlller RCW2 to control up to 15 units with independent set points and programming. DK-DN-155-205-255 Size DK 155 DK-V 155 DK 205 DK 255 INDOOR UNIT Cool only DN 155 DN 155 DN 205 DN 255 Reversible DN 155RC DN 155RC DN 205RC DN 255RC CapacitIes Cooling capacity kw 14,5 14,5 19,1 21,0 Cooling Power input kw 5,8 5,8 7,3 8,6 EER 2,5 2,5 2,6 2,4 Heating capacity kw 15,7 15,7 18,3 21 Heating Power input kw 5,8 5,8 6,7 7 COP 2,7 2,8 3 2,9 INDOOR UNIT Available static pressure Pa 130 110 210 210 Fan Nominal Airflow m³/h 2850 2850 4500 4680 Airflow range (min/max) m³/h 2300/3100 2300/3100 3600/5000 3800/5100 Sound Levels Sound power level db(a) 73 72 84 84 Dimensions LxWxH mm 1350x745x340 1254x972x350 1352x1060x400 1692x1060x400 Mounting H/V H H/V H H Weight Unit weight kg 65 77 98 100 OUTDOOR UNIT Fan Number of fan 1 1 1 1 Nominal Airflow m³/h 9000 9000 9000 9000 Sound Levels Sound power level db(a) 82 82 78 78 Dimensions LxWxH mm 900x800x1060 900x800x1060 900x800x1060 900x800x1060 Weight Unit weight kg 150 150 164 164 POWER SUPPLY Power supply 400V/3P/50 Hz Power supply side Outdoor PIPE LINE Suction pipe diameter < 20m inches 7/8" 7/8" 1-1/8" 1-1/8" Suction pipe diameter > 20m inches 3/4" 3/4" 1-1/8" 1-1/8" Liquid pipe diameter < 20m inches 1/2" 1/2" 1/2" 1/2" Liquid pipe diameter > 20m inches 1/2" 1/2" 5/8" 5/8" Max lenght m 50 50 30 30 Max height m 50 50 15 15 PRODUCT CODE DK205 DK 255 Indoor Unit 7SP051169 7SP051158 7SP051159 7SP051160 Small Fan Price 1071 1221 1768 1954 High Fan - - - - Price - - - - AccessorIes Outdoor Unit - Cool only Outdoor Unit - Reversible Standard With all-season control Standard With all-season control Electric heater Remote control RCW2 Air filter 7SP111093 7SP111093 7SP112224 7SP112119 Price 3204 3204 3544 4413 7SP111109 7SP111109 7SP112257 7SP112258 Price 3429 3429 3753 4577 7SP111112 7SP111112 7SP112076 7SP112077 Price 3593 3593 3847 4733 7SP112266 7SP112267 7SP112263 7SP112264 Price 8318 9863 4098 4937 kw 6 10,5 12 18 7ACEL1096 7ACEL1209 7ACEL1186 7ACEL1189 Price 528 660 929 951 kw 8,1 - - - 7ACEL1097 - - - Price 528 - - - 7ACVF0078 - - - Price 220-151 151 72 73

Direct Expansion DK-DN 305-405 Size DK 305 DK 405 M DK 405 INDOOR UNIT Cool only DN 305 DN 405 M DN 405 Reversible DN 305RC DN 405 mrc DN 405RC CapacitIes Cooling capacity kw 28,5 36,0 37,5 Cooling Power input kw 11,5 13,9 14,4 EER 2,5 2,6 2,6 Heating capacity kw 27,3 36,0 36,5 Heating Power input kw 9,3 13,3 11,9 COP 2,7 3 2,9 INDOOR UNIT Available static pressure Pa 190 180 180 Fan Nominal Airflow m³/h 5760 7560 7560 Airflow range (min/max) m³/h 4600/6300 6000/8200 6000/8200 Sound Levels Sound power level db(a) 78 83 83 Dimensions LxWxH mm 1690x1005x676 1690x1005x676 1690x1078x676 Mounting H/V H H H Weight Unit weight kg 150 160 160 OUTDOOR UNIT Fan Number of fan 1 1 1 Nominal Airflow m³/h 9000 16000 2x9000 Sound Levels Sound power level db(a) 86 83 87 Dimensions LxWxH mm 1003xx1003x1094 1004x1004x1257 1708x1123x972 Weight Unit weight kg 187 247 317 POWER SUPPLY Power supply 400V/3P/50 Hz Power supply side Outdoor PIPE LINE Suction pipe diameter < 20m inches 7/8" 1-3/8" 7/8" Suction pipe diameter > 20m inches 1-1/8" 1-3/8" 7/8" Liquid pipe diameter < 20m inches 5/8" 5/8" 1/2" Liquid pipe diameter > 20m inches 5/8" 5/8" 5/8" Max lenght m 30 30 30 Max height m 15 10 15 PRODUCT CODE DK 305 DK 405M DK 405 Indoor Unit Small Fan 7SP051161 7SP051165 7SP051162 Price 2422 2616 2616 High Fan 7SP051190-7SP051191 Price 2422-2777 Outdoor Unit - Cool only Outdoor Unit - Reversible AccessorIes Standard With all-season control Standard With all-season control 7SP112236 7SP112163 7SP112240 Price 5511 8023 7223 7SP112259-7SP112260 Price 5626-7638 7SP112078 7SP112166 7SP112079 Price 5751 8650 7863 7SP112265 Inclus 7SP112266 Price 5907-8318 kw 18 21 21 Electric heater 7ACEL1176 7ACEL1177 7ACEL1177 Price 1387 1434 1434 kw - - - Remote control RCW2 Price Air filter 7ACVF0125 7ACVF0125 7ACVF0125 Price 266 266 266 DK-DN 505-605-755-905 Size DK 505 DK 605 DK 755 DK 905 INDOOR UNIT Cool only DN 505 DN 605 DN 755 DN 905 Reversible DN 505RC DN 605RC DN 755RC DN 905RC CapacitIes Cooling capacity kw 44,0 56,0 69,1 83,0 Cooling Power input kw 16,7 22,5 26,9 33,0 EER 2,6 2,5 2,6 2,5 Heating capacity kw 42,0 57,5 71,0 83,8 Heating Power input kw 14,4 22,9 26,4 32,4 COP 2,5 2,7 2,6 2,5 INDOOR UNIT Available static pressure Pa 520 320 330 460 Fan Nominal Airflow m³/h 9360 9720 12000 14300 Airflow range (min/max) m³/h 7500/10300 7780/11000 9600/13200 11440/15730 Sound Levels Sound power level db(a) 84 85 87 87 Dimensions LxWxH mm 2100x1078x703 2100x1078x703 2208x949x795 2208x949x945 Mounting H/V H H H H Weight Unit weight kg 205 209 266 282 OUTDOOR UNIT Fan Number of fan 2 2 2 2 Nominal Airflow m³/h 2x9000 2x9000 2x16000 2x16000 Sound Levels Sound power level db(a) 86 86 87 87 Dimensions LxWxH mm 1708x1123x1171 1708x1123x1171 2213x1345x1309 2213x1345x1459 Weight Unit weight kg 378 405 559 592 POWER SUPPLY Power supply 400V/3P/50 Hz Power supply side Outdoor PIPE LINE Suction pipe diameter < 20m inches 7/8" 1-1/8" 1-1/8" 1-3/8" Suction pipe diameter > 20m inches 7/8" 1-1/8" 1-3/8" 1-3/8" Liquid pipe diameter < 20m inches 1/2" 1/2" 5/8" 5/8" Liquid pipe diameter > 20m inches 5/8" 5/8" 5/8" 5/8" Max lenght m 30 30 30 30 Max height m 15 15 15 15 PRODUCT CODE DK 505 DK 605 DK 755 DK 905 Indoor Unit Small Fan 7SP051163 7SP051164 7SP051130 7SP051131 Price 3248 3797 4243 4706 High Fan 7SP051192 7SP051193 - - Price 3847 3883 - - Accessories Outdoor Unit - Cool only Outdoor Unit - Reversible Standard With all-season control Standard With all-season control 7SP112235 7SP112237 7SP112164 7SP112165 Price 8619 10774 14587 17043 7SP112261 7SP112262 Inclus Inclus Price 8970 11022 7SP112080 7SP112081 7SP112167 7SP112168 Price 9489 10808 15922 18584 7SP112267 7SP112268 Inclus Inclus Price 9863 10904 kw 30 30 30 30 Electric heate 7ACEL1178 7ACEL1178 7ACEL1340 7ACEL1340 Price 1516 1516 1517 1517 kw - - - - Remote control RCW2 Price Air filterr 7ACVF0126 7ACVF0126 - - Price 247 247 - - 74 75

Direct Expansion XAR UC VERTICAL AIR CABINET COOLING ONLY NEW: Conform with ERP directive X AR Indoor Unit X 1100 AR X 1900 AR-V X 2450 AR-V X 3250 AR-V X 4650 AR-V X 6450 AR-V CapacitIEs Cooling capacity kw 9,7 16,2 19,8 29,0 38,9 55,0 Cooling Power input kw 4,6 6,8 8,9 12,6 16,9 24,0 EER 2,13 2,38 2,22 2,3 2,3 2,3 Cooling circuit 1 1 1 1 2 2 FANS Available static pressure Pa 200 300 200 200 250 290 Nominal Airflow m³/h 2000 3200 4500 5800 9000 12000 Airflow range (min/max) m³/h 1500/2500 2500/3800 3600/5400 4600/7000 7200/10800 9500/14500 SOUND LEVELS Sound power level db(a) 66 68 75 81 77 85 DIMENSIONS LxWxH mm 890x430x1540 1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970 1980x790x1970 Plenum height mm 220 260 350 350 400 400 WEIGHT Unit weight kg 136 182 265 350 525 600 Cooling Capacity: from 9,7 to 55 kw Refrigerant : R407C Size : 6 Configurations: Split system Product Avantages Easy installation and maintenance. Split system with outdoor condenser fan unit. Treated air distribution to premise by plenum or duct network. Adjustable available static pressure. Temperature control by thermostat. Electrical, refrigeration and thermal protection devices. Indoor unit Minimum air temperature (room/intake/around unit) Maximum air temperature (room/intake/around unit) Outdoor unit Minimum air temperature/with all-season kit Maximum air temperature FACTORY Operating limit for Standard unit 21 C BS/15 C BH 32 C BS/23 C BH 15 C BS/-10 C 46 C BS Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE Room thermostat. Electric heater. Hot water heating coil. All season system (Cooling mode operation down to outdoor temperatuire of -10 C). Remote fault reporting. Plenum. Duct flange. Valves. Pipe link. FANS SOUND LEVELs DIMENSIONS WEIGHT POWER SUPPLY PIPE LINE PRODUCT CODE AccessorIes Outdoor Unit UC 33 UC 54 UC 74 UC 104 UC 74 UC104 Condenser unit 1 1 1 1 2 2 Nominal Airflow m³/h 220 260 350 350 400 400 Sound power level db(a) 54 58 61 73 64 76 LxWxH mm 885x825x831 885x825x831 1141x885x831 1546x885x893 1141x885x831 1546x885x893 Unit weight kg 59 68 93 130 93 130 Power supply Power supply side 400V/3P/50 Hz Intérieur Suction pipe diameter inches 1/2" 1/2" 5/8" 3/4" 5/8" 3/4" Liquid pipe diameter inches 3/8" 3/8" 1/2" 5/8" 1/2" 5/8" Max lenght m 45 45 45 45 45 45 Indoor Unit - XAR Outdoor Unit + UC Outdoor Unit + UC TTS System "All seasons" Set of female valves Pipe link Electric heater Hot water coil ON/OFF switch and room thermostat "High Fan" Kit report défauts à distance Air distribution duct frame Total rear air intake duct frame Front air distribution plenum Fresh air intake 7XU022212 7XU122213 7XU122214 7XU122215 7XU122216 7XU122217 Price 3 936 5 139 7 284 8 285 12 385 14 959 UC 33 UC 54 UC 74 UC 104 2 x UC 74 2 x UC 104 7XU031053 7XU131054 7XU131055 7XU131056 2 x 7XU131055 2 x 7XU131056 Price 1 316 1 933 2 303 3 180 4 607 6 360 - UC 54 TTS UC 74 TTS UC 104 TTS 2 x UC 74 TTS 2 x UC 104 TTS - 7XU131065 7XU131066 7XU131067 2 x 7XU131066 2 x 7XU131067 Price - 2098 2 461 3 490 4 921 6 980 7ACFH0069 - - - - - Price 561 - - - - - 7ACFH0054 7ACFH0055 7ACFH0056 7ACFH0061 7ACFH0057 7ACFH0060 Price 68 77 79 145 155 242 7ACFH0210 7ACFH0211 7ACFH0212 7ACFH0213 7ACFH0214 7ACFH0215 Price 272 282 345 348 371 549 kw 9 12 18 22,5 37,5 45 7ACEL0042 7ACEL0043 7ACEL0057 7ACEL0058 7ACEL0116 7ACEL0119 Price 637 728 1 738 2 103 2 493 2 731 kw 15,5 29,7 38,5 50 77 94 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180 7ACFH0170 Price 388 375 753 677 908 900 7ACEL0041 7ACEL0041 7ACEL0032 7ACEL0032 7ACEL0032 7ACEL0032 Price 113 113 554 554 554 554 7ACVF0023 7ACVF0024 - - - - Price 527 556 - - - - - - 7ACEL0072 7ACEL0072 7ACEL0071 7ACEL0071 Price - - 288 288 241 241 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052 7ACVF0052 Price 53 61 49 47 50 50 7ACVF0041 7ACVF0104 7ACVF0043 7ACVF0044 7ACVF0045 7ACVF0046 Price 48 132 63 67 73 74 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110 7ACVF0111 Price 440 499 981 1 024 1 167 1 266 7ACVF0047 7ACVF0047 - - - - Price 113 113 - - - - 76 77

Direct Expansion XAO VERTICAL WATER CABINET COOLING ONLY Cooling Capacity: from 8 to 45,7 kw Refrigerant : R407C Size : 6 Configurations: Monobloc system Product Avantages Easy installation and maintenance. monobloc system. Public or recycled water operation. Treated air distribution to premise by plenum or duct network. Adjustable available static pressure. Temperature control by thermostat. Electrical, refrigeration and thermal protection devices. INDOOR UNIT Minimum air temperature Maximum air temperature Minimum water temperature Maximum water temperature FACTORY Operating limit for Standard unit 21 C BS/15 C BH 32 C BS/23 C BH +10 C +30 C Conçus & fabriqués en Designed & produced in depuis 1947 Main Options Room thermostat. Electric heater. Hot water heating coil. Remote fault reporting. Plenum. Duct flange. FRANCE X AO Size CX 25 X 1100 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO CapacitIEs Cooling capacity kw 8,0 11,7 18,0 23,0 32,4 45,7 Cooling Power input kw 2,6 3,8 5,8 7,1 9,8 13,9 EER 3,14 3,08 3,1 3,24 3,31 3,29 Cooling circuit 1 1 1 1 1 2 FANS Available static pressure Pa 80 200 250 200 250 250 Nominal Airflow m³/h 1500 2000 3200 4500 5800 9000 Airflow range (min/max) m³/h 1160/1750 1500/2500 2500/3800 3600/5400 4600/7000 7200/10800 WATER CONNECTIONS Wasted water Recycled water SOUND LEVELs POWER SUPPLY DIMENSIONS WEIGHT PRODUCT CODEs 230V/1P/50 Hz 400V/3P/50 Hz Water flow m³/h 0,34 0,58 0,92 1,45 2 2,8 Pressure drop kpa 20 22 18 42 40 18 Water flow m³/h 1,17 2,1 3,4 4,3 5,8 8,3 Pressure drop kpa 21 50 70 60 40 56 Sound power level db(a) 64 65 67 74 80 76 Power supply 230/1P/50 Hz 400V/3P/50 Hz 400V/3P/50 Hz LxWxH mm 800x407x 1280 890x430x1540 1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970 Plenum height mm 300 220 260 350 350 400 Unit weight kg 125 151 199 305 380 565 with valve without valve 7XU012110 - - - - - Price 3 677 - - - - - 7XU012111 7XU012112 7XU012113 7XU012114 7XU012115 7XU012116 Price 3 728 4 368 5 392 8 439 10 435 15 037 - - - 7XU012117 7XU012118 7XU012119 Price - - - 8 441 10 529 14 040 AccessorIes kw 5,49 9 12 18 22,5 37,5 7ACEL0017 - - - - - Electric 230V/1P/50 hz Price 675 - - - - - heater 400V/3P/50 Hz 7ACEL0018 7ACEL0042 7ACEL0043 7ACEL0057 7ACEL0058 7ACEL0116 Price 748 637 728 1 738 2 103 2 493 kw - 15,5 29,7 38,5 50 77 Hot water coil - 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180 Price - 388 375 753 677 908 ON/OFF switch and room thermostat 7ACEL0030 7ACEL0041 7ACEL0041 7ACEL0032 7ACEL0032 7ACEL0032 Price 110 113 113 554 554 554 "High Fan" 7ACVF0025 7ACVF0023 7ACVF0024 - - - Price 525 527 556 - - - Sum heating resistance 7ACVF0027 7ACVF0029 inclus - - - Price 71 48 - - - - Remote fault reporting - - - 7ACEL0072 7ACEL0072 7ACEL0071 Price - - - 288 288 241 Air distribution duct frame - 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052 Price - 53 61 49 47 50 Total rear air intake duct frame - 7ACVF0041 7ACVF0104 - - - Price - 48 132 - - - Front air distribution plenum 7ACVF0112 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110 Price 566 440 499 981 1 024 1 167 Fresh air intake - 7ACVF0047 7ACVF0047 - - - Price - 113 113 - - - 78 79

Direct Expansion CDN AIR COOLED CONDENSING UNIT COOLING MODE Cooling Capacity: from 19 to 83 kw Refrigerant : R407C Size : 8 Configurations: Monobloc system Product Avantages Weather resistant casing with external panels coated with powder-based epoxy paint colour RAL 9001. Compatible with any indoor unit. Easy service acces to main components. Hermetic Scroll compressor with crankcase heater. Low noise fan. Phase controller. External HP and LP pressure taps. Electrical, refrigeration and thermal protection devices. FACTORY Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE BAZ version: complete with standard component and fan speed controller. BAC version: BAZ version + suction accumulator. BAL version: BAZ version + suction accumulator + liquid receiver. CDN UNIT Size CDN 205 CDN 305 CDN 405 M CDN 405 CDN 505 CDN 605 CDN 755 CDN 905 CapacitIEs Cooling capacity kw 18,6 27,8 36,0 35,1 44,4 55,6 69,1 83,0 Power input kw 6,5 9,5 12,4 13,0 16,1 19,0 22,9 27,5 Number of refrigerant circuits 1 1 1 2 2 2 2 2 FANS Number of fan 1 1 1 2 2 2 2 2 Nominal Airflow m³/h 8600 9000 16000 2x9000 2x9000 2x9000 2x16000 2x16000 Sound levels Sound power level db(a) 78 82 83 82 84 87 87 87 POWER SUPPLY Power supply 400V/3P + N + Earth/50 Hz Max current A 16,5 24 32 38 39 47 56 67 Max starting current A 104 131 121 123 113 153 192 234 REFRIGERANT CONNECTION Suction pipe diameter inches 1-1/8" 1-1/8" 1-3/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" 1-3/8" Liquid pipe diameter inches 1/2" 1/2" 5/8" 1/2" 1/2" 1/2" 5/8" 5/8" DIMENSIONS (LxWxH) mm 900x800x1060 1003xx1003x1094 1003xx1003x1250 1708x1123x972 1708x1123x1171 1708x1123x1171 2213x1345x1304 2213x1345x1454 WEIGHT Unit weight kg 164 187 245 317 378 405 490 530 PRODUCT CODEs 205 305 405M 405 505 605 755 905 BAC 7SP112104 7SP112108 7SP112135 7SP112145 7SP112112 7SP112116 7SP112141 7SP112150 Price 3 056 4 625 6 419 6 264 7 332 9 057 11 671 13 635 BAL 7SP112105 7SP112109 7SP112136 7SP112183 7SP112113 7SP112117 7SP112142 7SP112151 Price 3 109 4 776 6 572 6 419 7 544 9 245 11 999 13 993 BAZ 7SP112222 7SP112223 7SP112203S 7SP112232 7SP112204S 7SP112205S 7SP112207 7SP112206S Price 3 014 4 505 6 237 6 084 7 005 8 731 11 344 13 237 Operating limit for Standard unit COOLING MODE Minimum outdoor air temperature (with fan speed controller) -10 C Maximum outdoor air temperature 46 C BS 80 81