APPLICATIONS. With our high quality light curtains we are a trusted, long-term partner of the leading elevator manufacturers.

Similar documents
VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Sitron s CF Line of Flow Switch Monitors

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

SENSOR SOLUTIONS FOR DOORS

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

SENSOR SOLUTIONS FOR DOORS

More Precision. thicknesssensor // The sensor for precise thickness measurements

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dräger REGARD -1 Control System

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Allure EC-Smart-Air Series Communicating sensors

Synchronous Detector

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Sensing light curtain as per DIN 18650/EN 16005

Compact Catalog Solar

Intrusion Outdoor Protection Perimeter

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

PolyGard 2-channel Gas Controller MGC-03

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Topscan G3 Presence detector for automatic doors

Sensing light curtain as per DIN 18650/EN 16005

D-Tect 2 GJD300 Quad PIR Movement Detector

WIO200 Water In Oil measuring instrument

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

English. Series. Installation and Use Manual

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Universal controller for panel mounting Models CS6S, CS6H, CS6L

PARVIS Safe and tranquil thanks to Parvis

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

I/A Series 716C 1/16 DIN Temperature Controller

Danfoss gas detection units

1. Product description

Movement Detector GJD 300

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Dräger Flame 2350 (UV&IR) Flame Detection

Machine Guarding and Safety

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

Turbimax CUE21 / CUE22

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

HRTL 96B Laser light scanner featuring background suppression for object detection and accurate positioning

Series 25B Photoelectric Sensors and Light Scanners PRODUCT INFORMATION

AIS750 Series Alarm Annunciator

Flame Monitors BROCHURE

DTA. Motor thermistor relay. Benefits. Description

Dräger Flame 2100 Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

Safety Sensor Eden AS-i Machine safety - Jokab Safety products

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Universal fault annunciator for panel mounting

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Retroreflective sensor with polarization filter

2 General Application Photoelectric Sensors

Dräger Flame 2700 (Multi-IR) Flame Detection

WP4086 Condition Monitoring System

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Engineering Guideline. pac- Carriers Type Universal

IT system floor-standing distribution

Vacuum drying oven for non-flammable solvents

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

SIL2-Interface/ -Signal Conditioners Series DuoTec

Operating Manual MS220DA

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Dräger Flame 2500 Flame Detection

TEC1100 Series Thermostats

Dräger Flame 2500 (IR3) Flame Detection

ISIS SAFETY SYSTEM Installation guide

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Interface and EOL Modules 8

Retroreflective sensor with polarization filter

Dräger REGARD -1 Control System

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Plug-in Base, Long Range Sensor E3B2

General Purpose Photoelectric Sensor

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

VISION H. Instruction manual

Dräger Flame 2100 (UV) Flame Detection

ACTIVE INFRARED BARRIER

MINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. General Purpose Photoelectric Sensor

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Transcription:

measure detect ELEVATOR AUFZUGBAU INDUSTRY READY FOR!»EN 81-20»EN 81-70 KOMPETENT EXPERIENCED I LEISTUNGSSTARK I POWERFUL I SOLUTION I LÖSUNGSORIENTIERT ORIENTED Ihr Your Partner partner für for industrielle industrial Optosensoren. opto sensors. We Änderungen, reserve the Irrtümer right to make und evtl. any Fehler changes sind or vorbehalten mistakes.

APPLICATIONS ACCESS AREA Safeguarding of door clearance is a classical light curtain domain. The LT40 complies with the European standards EN81-20 and EN 81-70:» Detecting of objects from 50 mm.» Reporting sensor faults to the elevator control system.» Integration of door monitoring into the system test. PRESENCE SENSING Specifically in elevators which provide access to protected or private floors, the detection of persons or devices in the cabin is very important. The flexibility and functionality of our light grids ensure gapless surveillance. CABIN ROOF AND SERVICE AREA MONITORING Due to increasingly important safety aspects, the monitoring of hoistway and cabin roof gains in importance. With our high quality light curtains we are a trusted, long-term partner of the leading elevator manufacturers. measure detect

LT40-LIGHT CURTAINS The LT40 was specifically developed for use in elevators, doors and gates. It is very easy to install, cost-efficient and available in the typical monitoring heights. The LT40 complies with the EN81-70 and EN81-20 requirements. Through use of parallel beams, the detection of objects equal to or greater than 50 mm is ensured over the whole monitoring area. The LT40 is fully compatible to its predecessor and can easily be used to modernize existing elevator systems that already utilize DUOmetric products. OPTICAL DATA Monitoring height 1794 mm Range 0,7 5,0 m Number of beams 40 Beam spacing 46 mm Light source IR-LED 880 nm Base cycle time 4 ms Per beam cycle time 1 ms Controller integrated ELECTRICAL DATA Operating voltage Power consumption output logic 24 VDC (18... 30 VDC) 10% ripple nominal: 3,1 W Semiconductor short circuit-proof PNP/NPN (push-pull) ENVIRONMENTAL DATA Ambient temperature -30 +55 C (operational) Humidity <90% relative / non-condensing Protection class IP54 Compliance EN 81-20 & EN 81-70 ROHS / REACH / CE

LI / LVB-SYSTEM LI-LIGHT GRIDS These light grids have been optimized for fast and reliable object detection. They are connected to an external controller which results in minimal blind spots in the monitoring area and various system options. Through configuration the system functions can be changed and adapted to your specific requirements. OPTICAL DATA Monitoring height Range Beam spacing Light source IR-LED Per beam cycle time Controller 35... 5812 mm 0,4... 6 m 2,5... 112 mm 880 nm please refer to Controller external: LVE / LVX / LVB / LVR ENVIRONMENTAL DATA Ambient temperature -30... +55 C (operational) -20 +40 C (ccsaus-version) Humidity < 90 % relativ / non-condensing Protection class IP54 / (IP65) Compliance ROHS / REACH / ccsaus / CE

LVB-CONTROLLER This controller is the ideal addition to our LI light grids. The LVB is designed as an external controller with a plastic enclosure. It has output relays with forcibly guided contacts. The controller can be configured with different parameters according to your applications. The special configurations allow compliance with local requirements. SYSTEM DATA Profile pairs 1 Number of beams (physical) max. 500 Number of beams (logical) max. 500 Per beam cycle time ab 80 µs Interface RS232 Interface parameters 115200 bps / 8n1 ELECTRICAL DATA Power supply LVB: 230 VAC (+5%.- 10%) LVB-24: 24 VDC (18...30 V) Power consumption ~3,6 W (mit Leisten) Connections spring clamp Relay contacts closed with free monitoring area Switching current min.10 ma / max. 5 A Switching capacity min. 0,1 VA / max. 2000 VA bzw. 0,1 W / 200 W ENVIRONMENTAL DATA Ambient temperature 0 +40 C (operational) Humidity < 90 % relative / non condensing Protection class IP20 (inside) Compliance ROHS / REACH / ccsaus (LVB-24 V) / CE

ABOUT US We work in close cooperation with our customers and consider the demanding requirements of various industries to provide flexible solutions for your applications. Development Know-how new and innovative products emerge from the heads of our engineering and development team. Manufacturing Implement ideas - the heart of DUOmetric works with precision manufacturing to ensure the high German quality standard. Service You can count on us - helping hands are ready to support you in the consulting, planning and implementation phase. You need a customized light grid? No problem! We incorporate your demands. The DUOmetric portfolio is waiting to be explored by you. DUOmetric AG Weberstraße 8 86836 Graben Germany +49 8232 959 79-0 +49 8232 959 79-29 info@duometric.de www.duometric.de