XM-18D. Operation Instruction

Similar documents
EST User Manual. (Please read this manual carefully before using)

720P HD Wireless Doorbell Instruction

USER GUIDE Heat Index Psychrometer

INSTALLATION CHART Guangli Spray booth Model: GL1

HUMIDITY IN INCUBATION

Model 5190-F Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

USER MANUAL Digital CO Monitor Model CO30

HATCHERY. ROSS TECH Hatchery Maintenance. August 2011

Halogen Moisture Analyzer

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Infrared Moisture Balance (FD-660)

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Black Body Calibration Source User Manual

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

SPECIFICATIONS. HCA131A-High Accuracy 4 directions Control Switch(Switch Output) Item No.:HCA131A

Operations Manual DS 220. Docking Station for Micro IV

Refrigerated Incubators / Environmental Testing Chambers

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

ENVAIR lab CO2 Tri-Gas Incubator

Advance Humidity Pump with Octagon 20 and 40 Advance EX Upgrade

Mark 25 Ultrapure Water Conductivity Analyzer

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Read the instructions before use!

DOs & DON Ts: for your safety and the safety of your incubator:

2-wire Passive Intelligent Loop (LED) Display Meter

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

Advance Humidity Pump

USER MANUAL USB Multi-Function Datalogger Model RHT35

Next press Date and Time

STABILITY TEST CHAMBERS

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Netbiter Tank Sensor

University of Minnesota Nano Fabrication Center

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

HUM-M2 Humidity Sensor Module Description

esense CO2 Transmitter and Alarm

Solutions for a WORRY FREE HATCHERY. HatchVAC. No one knows HVAC like

2-wire Passive Intelligent Loop (LED) Display Meter

YanCheng STG Safety Equipment Co.,Ltd 1

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Constant climate chamber with ICH-compliant illumination

SimpleVIS Viscometer Reference Guide P

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

OVA-EASY ADVANCE. HATCHER User Instructions

Warranty Registration

Read the instructions before use!

APC BC300 Series 40kW 208/450/480V User Guide

Parts introduction FRONT BACK

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

Analog Room Pressure Monitor RPC Series

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

atten Color ^ Back to Top Clients Login Username: Password: Home About Us Products News Video Service Support Join Us Contact Us

Welcome to Shenzhen Keweitai Enterprise Development Co,.ltd. Safety, Professional, Easy, Long endurance, Long distance

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

CONTENTS INSTALLATION 21 USING THE SIGNAL KEY 10 SPECIFICATION 23

Constant climate chambers

Viper Climate and Production Computer

REFRIGERATOR P H A R M A C Y.

Constant climate chamber with humidity

ZL-7901A Intelligent temperature and humidity controller Instruction Manual A1.0

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Introduction. OM-THA2

FLOW CONTROLLER TYPE S/601

S/601 Controller Installation Manual

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Installation & Calibration Guide

GMH 285 / GMH 285-BNC

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Manual Vane Anemometer PCE-VA 20

Duct Mount. Installation Instructions

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Counting Scales. HC-i Series.

Portable type of Carbon Dioxide Detector Model: GT220

HUMIDITY MANAGEMENT MODULE TYPE H122 Digital USER INSTRUCTIONS

ELECTRONIC HUMIDISTAT: H200

Infrared Moisture Balance (FD-800)

Models: 370/371 and 380/381

Constant climate chambers

CB-CW-1 Cool/Warm Mattress Owner s Manual. Contents

Model gffoz Process Ozone Sensor (In-Line)

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

MEAS PICTAIL PLUS FOR MICROCHIP EXPLORER 16

LogTag TICT - is0 Tag

INCUBATOR MOD 25-C PDS

Commodity Description

settings and adjustments

Desicators & Dry Cabinets

How to use Medi-Therm III hyper/hypothermia system

Transcription:

Intelligent Hatch Controller XM-18D Operation Instruction

The automatic multi-function incubator researched and produced by our company uses the more popular microcomputer-based technology (using the latest micro-electronics technology and new components), equiping with the imported digital temperature sensor and France moisture sensitive capacitance humidity sensor, which makes this instrument miniaturization, intelligent, high measurement accuracy. This incubator is stable and reliable, time-saving, labor-saving, and easy-to-use. It is the ideal incubation equipment for propagation of poultry and rare birds and small and medium-sized hatchery. 一 Main Technical Index: 1.Temperature Measuring Range: 0-99 2.Temperature Measurement Accuracy: ±0.1 3.Humidity Measurement Range: 099%RH 4.Humidity Accuracy: ±3%RH 5.Number of signal-output: 7, (over-temperature, temperature control, insufficient temperature, egg left-turning, egg right-turning, humidity control, alarm) 6.The maximum output load current: temperature control, insufficient temperature 8A/AC220V, over-temperature, egg left-turning, egg right-turning, humidity control, alarm 1A / AC22 7.Number of egg-turning: the maximum record is 999 times. 8.cycle of egg-turning: adjustment of 0 999 minutes (the factory default is 90 minutes) 9.egg-turning time: adjustment from 0 to 999 seconds (the factory default is 180 seconds) 10.ventilation cycle: from 0 to 999 minutes (the factory default is 120 minutes) 11.ventilation time: from 0 to 999 seconds (the factory default is 30 seconds) 12.Temperature measurement length: About 2 meters 二 Working Condition: 1.Working Voltage: AC 160V - 240V,50HZ 2.Relative Humidity: less than 85% RH 3.Environment Temperature: -10-60 三 Temperature and humidity settings instance: This method is very simple, as long as you set up both points of temperature and humidity, others will generate automatically. For example, a incubation control room needs that the temperature is 38, humidity is 60% RH. 1

During normal working, press SET and lift your hand, a row of led will display on the lower side of the controller. If you need to change the temperature value, t t press to adjust, till to display the temperature 38 you required. And then pressok and raise your hand, the led will display on the lower side of the controller. If you need to change the humidity value, please press H H to adjust untill the required humidity 60% RH shows. And then press the keyok OK, the controller will automatically calculate and fill the parameters of temperature and humidity, and finally return to normal working state. 四 Arbitrary temperature and humidity settings example (which may change and automatically generate interval, but generally do not use it) During normal operation, press the key SET and don t raise your hand, and then press the key untill display parameters: rs: P 1 and then raise your hand, set up the following Set up over-temperature alarm: led display as shown in right figure: P1 is the over-temperature alarm value, the alarm will be given if the temperature reaches this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up over-temperature value: led display as P 1 P 2 shown in right figure: P2 is the over-temperature value, the exhaust fan will be started up when the temperature reaches this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up upper limit value of temperature P 3 2

control: led display as shown in right figure: P3 is the upper limit of temperature control. The heating will stop when the temperature reaches this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up lower limit value of temperature P 4 control: led display as shown in right figure: P4 is the lower limit of temperature control. The heating will start up when the temperature droppes to this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up low temperature value: led display as shown in right figure: P5 is the low temperature value. The standby heating will start up when the temperature droppes to this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up insufficient-temperature alarm value: P 6 led display as shown in right figure: P6 is the insufficient-temperature alarm value. The alarm will be given if the temperature droppes to this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up over-humidity alarm: led display as shown in right figure: P7 is the over-humidity alarm value. The alarm will be given if the humidity reaches this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up upper limit value of humidity control: P 5 P 7 P 8 3

led display as shown in right figure: P8 is the upper limit value of humidity control. The humidification will stop when the humidity reaches this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up lower limit value of humidity control: P 9 led display as shown in right figure: P9 is the lower limit of humidity control. The humidification will start when the humidity droppes to this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up low humidity alarm value: led P P display as shown in right figure: PP is the low humidity alarm. The alarm will be given if the humidity droppes to this value. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. 五 Egg-turning and calibration parameter setting During normal operation, press the key SET and don t raise your hand, and then press the key till display and then raise your hand, set up the following parameters: rs: Set up egg-turning interval: as shown: "F1" is two successive egg-turning interval (unit: minute), if any change is nedded, please press untill it displays the value you required. And press OK and then lift your hand to save data, and automatically move to the next parameter setting. Set up egg-turning time: led display as F 2 shown in right figure: "F2" is the egg-turning time (unit: second), F 1 F 1 F 1 4

which represents the time of turning eggs, if any change is necessary, please press untill it displays the number you required. And press OK and then lift your hand to save data, and automatically move to the next parameter setting. Set up ventilation interval: led display as F 3 shown in right figure: F3 is the ventilation interval time (unit: second), if any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up ventilation time: led display as shown F 4 in right figure: F4 is the ventilation time (unit: second), if any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up temperature calibration: led F 5 display as shown in right figure: F5 is the temperature calibration value, this parameter may revise the temperature deviation brought about by improper selection of temperature measuring point. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Set up humidity calibration: led display as F 6 shown in right figure: F6 is the humidity calibration, this parameter may amend the humidity deviation caused by improper selection of humidity measuring point. If any change is needed, please press untill it displays the value you required. And press OK and then raise your hand to save data, and automatically move into the next parameter setting. Number of egg-turning: led display as F 7 shown in right figure: F7 is the number of egg-turning, press the key OK and then raise your hand to return to the normal working state. 六 Egg-turning and Silencing Description 5

Egg-turning Mode: Automatic egg-turning: Turn eggs automatically in accordance with the set egg-turning interval and egg-turing time, turn left interval turn right interval turn left...... alternation of egg-turning. The number of egg-turning will display on the parameter F7, and will be zero if the controller power is cut off. In order to ensure normal egg-turing, please switch to the state of automatic egg-turing. Manual egg-turning: Press the key and do not lift your hand, the controller will enter into the state of manual egg-turing after2 seconds. You're your hand when it is adjusted to the desired location, the controller will get into the state of automatic egg-turing. The computer wil define automatically the direction of egg-turning. Silencing function: when the controller give an alarm, press the key and lift your hand, to remove the buzzer sound and alarm output, but then the alarm indicator lamp still lights up; press the key again and raise your hand, to restore buzzer sound and alarm output control. 七 Restore Factory Settings Press both keys of at the same time for more than three seconds, the controller will display zero. Raise hand immediately after hearing Di from the buzzer, the controller will automatically restore the factory settings. Factory Settings: Reference temperature: 38.0 ; reference humidity: 60% RH; cycle of egg-turning: 90-minute; time of egg-turning: 180 seconds; ventilation cycle: 120 minutes; ventilation time: 30 seconds; egg-turning state: automatic egg-turning 6

八 Controller Wiring Diagram: Welcome to use our automatic incubator by computer! Please pay attention to the following aspects in use: 1.The micro-computer controller has been made adjustment for temperature, humidity, egg-turing, exhaust, etc. before leaving factory, which meets settings required by incubation ion. Under normal circumstances, you do not need to set up and may use it by connecting the power supply. Factory settings: temperature 38, humidity 60% RH; cycle of egg-turning: 90-minute, time of egg-turning: 180 seconds; ventilation cycle: 120 minutes; ventilation time: 30 seconds; egg-turning state: automatic egg-turning. 2.If you need only to change the temperature and humidity parameters, please refer to Section III in page 2 of this Manual. Please do not set up other parameters in order to avoid operation errors which may affect your usage and bring you f unnecessary losses. 3.Temperature and humidity sensors are made of high precise and micro-molecular materials, please do not make the sensor come into contact with the water directly. The dust must be regularly cleared on the surface of the sensor, or it will affect the measurement accuracy. 4.The manufacturer should only assume the obligation for products selled to users, but not undertake users other losses caused by product failure. 7