Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Similar documents
Reusable Laryngoscope Blades and Handles

All Truphatek's products:

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Cleaning & Sterilization

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Instructions for Use: Fiberscope and LED Light Source

FLASH PAK STERILIZATION CONTAINER SYSTEM

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

STERITITE INSTRUCTIONS FOR USE

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

CLEANING INSTRUCTIONS

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

H5i disinfection guide

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Table of Contents. English

I.F.U Re/Processing Reusable Medical Devices

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

X99 Series. Dental Handpiece. Instruction For Use

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

1 Intended Use of the Breas HA 01 Humidifier

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

SteriTite - The Container System of Choice SteriTite

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

RECOMMENDATIONS FOR CLEANING DEVICES

Cleaning and Sterilization for Instruments & Posts

RAP-hip Hip stem extraction set

Operating / User Manual

Instructions for Use Spinal Punches IFU

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Cleaning and Sterilisation for Burs, accessories and filling material

Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

SteriTite - The Container System of Choice SteriTite

Packing. Euronda Spa t (+39) m euronda.com

idrive Ultra Powered Stapling System

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Guidelines for cleaning, disinfection, and sterilization of the biopsy adaptor, water bag, coupler, and magnetic sensor securing adaptor

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

THE BASICS OF DECONTAMINATION

Does your equipment meet your needs and the operational capacity stated by the manufacturer?

Aesculap Implant Systems

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Recommendations for cleaning, decontamination and sterilisation. devices

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Tornado Flusher disinfector

Processing Instructions. Cleaning so easy.

BIOVAC 500 SMOKE EVACUATOR

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Invacare Propad. General. Cushion User Manual. General information. Warranty. Standards and regulations. Symbols in this user manual.

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Operating Instructions

Cleaning and disinfecting

A new wave in instrument washing and disinfection Introducing the new HYDRIM c61wd G4 series

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

Cavitron Systems, Sterilizable Handpieces and Reservoir Bottles INFECTION CONTROL PROCEDURES

Decon Scrubber Owner s Manual

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

System One Heated Humidifier USER MANUAL

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

PORTABLE DOG BATH TOOL

Cavitator Ultrasonic Cleaner Instruction Manual

Flusher disinfectors for hospitals and nursing houses

301-P2000. Humidifier Heater, 115V. Instructions for Use. Pegasus Research Corporation, 1518 E Edinger Ave., Unit A, Santa Ana, CA 92705

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

When you sterilize an instrument set, you know what the standards are.

STERIS Instrument Cleaning Chemistries

INSTALLATION AND OPERATION MANUAL

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

Transcription:

Video Laryngoscope Operator s Manual ( Instructions for use ) Doc no: 100-160-000 Revision 1.1 8th January 2013 Aircraft Medical Ltd 2012 www.aircraftmedical.com

Contents 1 Introduction 2 1.1 Description 2 1.2 Accessories and Part Numbers 3 1.3 Specifications 3 1.4 Regulatory 4 1.5 Environment 4 2 Functional 5 2.1 Unpacking and Inspection 5 2.2 Battery 6 2.3 Blade Fitting 7 2.4 Using the Laryngoscope 8 3 Maintenance and Decontamination 9 3.1 Decontamination 9 3.2 Cleaning 10 3.3 Rapid Disinfection 12 3.4 High Level Disinfection 13 3.5 Sterilization 14 4 Storage and Transportation 15 5 Troubleshooting 16 6 Warranty 17 1

1 Introduction 1.1 Description The McGRATH MAC EMS Video Laryngoscope (McGRATH MAC EMS or the device) is a tool used to aid the intubation of the trachea. As a rigid McGRATH MAC EMS video laryngoscope (the device) Monitor hinge 45 Monitor laryngoscope it holds and shapes the anatomy allowing a clear view of the LCD screen larynx and entrance to the trachea. The need to provide a secure airway is fundamental to an anesthesiologist s role prior to a surgical procedure. Paramedics, Handle emergency physicians and general practitioners may also be required to insert a tracheal tube in an emergency to keep the airway open where an Camera & light source Clip Heel area unconscious patient is undergoing cardio-pulmonary resuscitation. CameraStick The device incorporates a light source (LED) and miniature camera (camera) to view the larynx during the procedure of laryngoscopy. The image is displayed on an LCD screen (screen) contained within a monitor mounted to the handle of the device. A McGRATH 3.6V EMS battery (battery) mounted within the handle powers the screen, camera, and LED. The McGRATH MAC disposable laryngoscope blade (blade) range covers the camera and LED assembly (CameraStick ) to prevent direct patient contact. The McGRATH MAC blades are supplied sterile and are single use. McGRATH 3.6V EMS Battery (battery) McGRATH MAC disposable laryngoscope blade (blade) SUPPLIED SEPARATELY Power button Tab Blade clip Blade 2

1.2 Accessories and Part Numbers UNDER NO CIRCUMSTANCES SHOULD ANY OTHER TYPE OF LARYNGOSCOPE BLADE BE USED WITH THIS MEDICAL DEVICE DO NOT OPEN ANY SEALED PART OF THE DEVICE UNDER ANY CIRCUMSTANCES. TO DO SO WILL IMPAIR THE PERFORMANCE OF THE DEVICE AND PATIENT SAFETY AND VOID WARRANTY The device is supplied with a battery. Blades and additional batteries can be purchased separately from your Aircraft Medical agent or distributor. McGRATH MAC EMS Video Laryngoscope 300-200-000 McGRATH 3.6V EMS Battery 340-200-000 McGRATH MAC 2 Disposable Laryngoscope Blades (Carton of 50) 350-017-000 McGRATH MAC 3 Disposable Laryngoscope Blades (Carton of 50) 350-005-000 McGRATH MAC 4 Disposable Laryngoscope Blades (Carton of 50) 350-013-000 McGRATH MAC EMS Quick Start Guide 300-248-000 McGRATH MAC EMS Instructions for Use (CD) 300-249-000 McGRATH MAC EMS Product Box including Instructions for Use (CD) and Quick Start Guide 300-240-000 1.3 Specifications Laryngoscope Assembly Size Weight Power Light source Display Camera Materials 180mm x 68mm x 110mm 0.200kg Proprietary 3.6V Lithium Battery *Giving 250 minutes of use typically High intensity LED 2.5 LCD colour display CMOS Durable medical grade thermoplastics with reinforced structural alloy core. The device and packaging are latex free * WHERE THE AMBIENT TEMPERATURE IS 20 C. BATTERY LIFE MAY VARY WHERE THE AMBIENT TEMPERATURE IS HIGHER OR LOWER Disposable Laryngoscope Blade The device can be used only with McGRATH MAC disposable laryngoscope blades Material Packaging Medical grade optical polymer Packaged sterile for single use only This device and packaging are latex free 3

1.4 Regulatory This product complies with EN 60601-1 and EN 60601-1-2 safety standards. The CE mark indicates that it meets the requirements of European Council Directives 93/42/EEC and 2007/47/EC concerning medical devices. The McGRATH MAC Disposable Laryngoscope Blades are classified as type BF applied parts in accordance with section 8.3 of EN60601-1:2006 The user must contact their Aircraft Medical agent or distributor to arrange responsible disposal and compliance with Waste Electrical and Electronic Equipment regulations applicable, and any similar future environmental regulation applicable (including but not limited to Directives 2002/95/EC and 2002/96/EC as implemented in the country of use). The device is regulated in the USA under FDA Regulation Number 868.5540 and device listed under the name McGRATH MAC. McGRATH is a registered trademark of Aircraft Medical Limited. Aircraft is a registered trademark of Aircraft Medical Limited. CameraStick is a trademark of Aircraft Medical Limited. Only personnel trained in and licensed to perform intubation with a laryngoscope may use this device. CAUTION : FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A LICENSED PRACTITIONER 1.5 Environmental Operating Conditions: Storage & Transport Conditions: 4

2 Functional 2.1 Unpacking and Inspection Unpack the device and check for any visible signs of damage that may have occurred during shipment. In the event of signs of damage, do not use the device and inform your Aircraft Medical agent or distributor. Both the device and battery unit are supplied in a non-sterile state. It will be necessary to decontaminate the device before use on a patient. Refer to Section 3 of this manual. The laryngoscope blade is supplied in a sterile state. Ensure that handling precautions are taken in accordance with local, national and harmonised standards. (Please note that the McGRATH MAC disposable laryngoscope blades are not supplied with the device. These are packed and purchased separately). 5

2.2 Battery The device will only accept the McGRATH 3.6V EMS battery. Push the battery unit into the cavity of the handle as illustrated. Power The device turns on and off by a single push of the Power button. The life of the battery unit is displayed on the bottom right hand corner of the screen. This counts down from 250 as each unit of power is consumed. When the counter reaches 5, the battery icon will flash. Replace the battery unit when this happens. Tab Remove the battery unit by pulling the tab and dispose of under local regulations for disposal of batteries. If the device is not to be used for an extended period of time (more than 1 month) remove the battery unit before storage. Flashing 6

2.3 Blade Fitting To fit the blade, open the peel pouch and slide the blade over the CameraStick portion of the device. The blade is fully located when the blade clip is firmly latched to the CameraStick. To remove the blade lift the clip and pull the blade off. McGRATH MAC DISPOSABLE LARYNGOSCOPE BLADES ARE SINGLE USE AND MUST BE DISPOSED OF AFTER EACH PATIENT USE ENSURE THAT LOCAL HANDLING PROCEDURES ARE FOLLOWED AT ALL TIMES WHILE HANDLING DISINFECTED DEVICES McGRATH MAC BLADES MUST ONLY BE USED WITH McGRATH MAC VIDEO LARYNGOSCOPES. CHECK THAT THE BLADE IS CORRECTLY FITTED TO THE CAMERASTICK BEFORE USING ON A PATIENT DO NOT ATTEMPT TO USE ANY OTHER LARYNGOSCOPE BLADES WITH THE DEVICE IF THERE IS ANY EVIDENCE THAT THE BLADE PACKAGING HAS BEEN BREACHED, DO NOT USE THE BLADE 7

McGRATH MAC McGRATH MAC McGRATH MAC 2.4 Using the Laryngoscope 1 If possible, position the patient in the optimal position for direct laryngoscopy. Look into the mouth; insert the blade into the right side of the mouth, moving the device to a central position while sweeping the tongue to the left. 2 Advance the blade into the vallecula. 3 Visualize the epiglottis on the screen. Lift the anatomy forwards and upwards to expose a direct and indirect view of the glottis. 4 When the device is in the optimal position the glottis should be viewed in the central upper section of the screen. 5 Advance the tube gently and atraumatically through the vocal cords. Tube placement can be performed either by looking directly in the 6 7 8 mouth, indirectly on the screen or a combination of both. If a direct pathway for the tube was not created by sweeping the tongue or aligning the airway axes a stylet or a bougie may need to be used. Indirectly visualize the tube placement through the vocal cords. The screen view can be used to confirm the correct insertion depth of the endotracheal tube. 8

3 Maintenance and Decontamination 3.1 Decontamination The device should be decontaminated immediately after each patient use. Decontamination should be carried out in accordance with local regulations. Follow hospital policy and protocol when handling and cleaning soiled items. The following methods of decontamination were developed using standard equipment and practices common to global healthcare facilities and according to regulatory requirements using the guidance given in AAMI TIR 12 (Designing, Testing, Labelling Reusable Medical Devices for Reprocessing in Health Care Facilities: A Guide for Device Manufacturers) and ISO 17664:2004 (Sterilization of medical devices Information to be provided by the manufacturer for the processing of resterilizable medical devices). The instructions provided have been validated by Aircraft Medical as being capable of preparing the device for re-use. It remains the responsibility of the processor to ensure that the reprocessing as actually performed using equipment, materials and personnel in the reprocessing facility achieve the desired result. This normally requires validation and routine monitoring of the process. Thorough cleaning and rinsing are vital for the decontamination of the device. The purpose of cleaning and rinsing is to remove soiling and to reduce the number of microbiological agents. Thorough rinsing is important for removing any residual cleaning agents from the medical device. The following methods have been approved by Aircraft Medical: PRODUCT CLEANING RAPID DISINFECTION* McGRATH MAC Disposable Laryngoscope Blade McGRATH MAC EMS with McGRATH 3.6V EMS Battery fitted McGRATH MAC EMS with McGRATH 3.6V EMS Battery removed McGRATH 3.6V EMS Battery Supplied Sterile Do Not Reprocess Cleaning (Manual) - Non-Immersive Cleaning (Manual) - Immersive Cleaning (Manual) - Non-Immersive Supplied Sterile Do Not Reprocess Disinfectant Wipe Disinfectant Wipe Disinfectant Wipe HIGH LEVEL DISINFECTION Supplied Sterile Do Not Reprocess High Level Disinfectant Immersion / Chemical Disinfector *Wherever practical a High Level Disinfection or Sterilization is preferred to a wipe-based process. STERILIZATION Supplied Sterile Do Not Reprocess STERRAD 50/100S/200/ NX/ 100NX STERRAD 50/100S/200/ NX/ 100NX Ethylene Oxide Sterilization 9

ENSURE THE DEVICE IS COMPLETELY DRY BEFORE USING DO NOT AUTOCLAVE THE DEVICE DO NOT REPROCESS THIS DEVICE IN AN ULTRASONIC CLEANER When decontaminating the McGRATH MAC EMS with the battery unit installed, disinfection or sterilization claims will only apply to exposed surfaces of the McGRATH MAC EMS or McGRATH 3.6V EMS Battery. When the battery unit has been removed, newly exposed surfaces should be treated as contaminated. Dispose of chemicals & detergents in accordance with local regulations and hospital policy. 3.2 Cleaning Aircraft Medical used Endozime and Cidezyme Enzymatic Medical Device Detergents when validating the processes below. Seek approval from your Aircraft Medical agent or distributor before using other detergents. Always follow the detergent manufacturer s instructions. CLEANING (MANUAL) NON-IMMERSIVE McGRATH MAC EMS with McGRATH 3.6V EMS Battery fitted Prepare Clean Rinse Repeat Dry Ensure cleaning containers, soft brushes and cloths have been decontaminated and are in good condition. Prepare a container of detergent in accordance with the detergent manufacturer s instructions. Hold the device above the container, and use soft cleaning brushes to remove soil from all exposed surfaces, taking care not to scratch optical surfaces. Using a microfiber cloth, wipe all surfaces thoroughly ensuring that detergent solution comes into contact with all surfaces. Periodically rinse the cloth and repeat. Scrub crevices and around hinged/mating surfaces with the soft brush. Hold the device over a large volume of rinse water and wipe down to remove all traces of detergent. The cleaning and rinsing steps should be repeated if the device was heavily soiled or if visible soiling remains after cleaning. Carefully hand-dry using clean, absorbent, non-shedding cloth. 10

3.2 Cleaning CLEANING (MANUAL) NON-IMMERSIVE McGRATH 3.6V EMS Battery Prepare Clean Rinse Repeat Dry Ensure cleaning containers, soft brushes and cloths have been decontaminated and are in good condition. Prepare a container of detergent in accordance with the detergent manufacturer s instructions. Hold the battery unit above the container, and use soft cleaning brushes to remove soil from all exposed surfaces. Using a microfiber cloth, wipe external surfaces thoroughly ensuring that detergent solution comes into contact with the surfaces. Periodically rinse the cloth and repeat. The battery unit is NOT immersible. Do not saturate the electrical contacts or the cavities surrounding the retaining clips with detergent or rinse water. If the battery unit is heavily soiled do not re-use. Discard accordingly. Hold the battery unit over a large volume of rinse water and wipe down to remove all traces of detergent. Again, take care not to saturate the electrical contacts and cavities surrounding the retaining clips with water. The cleaning and rinsing steps should be repeated if visible soiling remains after cleaning. Carefully hand-dry using clean, absorbent, non-shedding cloth. CLEANING (MANUAL) - IMMERSIVE McGRATH MAC EMS with McGRATH 3.6V EMS Battery removed Prepare Ensure cleaning containers or sinks, soft brushes and cloths have been decontaminated and are in good condition. Prepare a container of detergent in accordance with the detergent manufacturer s instructions. Pre Clean If visible soiling is present, immerse the device for a minimum of 5 minutes in enzymatic detergent solution prior to cleaning. Clean Rinse Repeat Dry Immerse the device for 5 minutes in fresh enzymatic detergent solution. Then, keeping the device immersed, use soft cleaning brushes to remove additional soil from challenging design features. Take care not to scratch optical surfaces. Scrub crevices and around hinged/mating surfaces with a soft brush. Remove the device from the solution and drain over the detergent solution before transferring to a clean-rinse receptacle or sink. Rinse device thoroughly with clean water, ensuring that it is fully immersed. Remove device from rinse water. The cleaning and rinsing steps should be repeated if the device was heavily soiled or if visible soiling remains after cleaning. Carefully hand-dry using clean, absorbent, non-shedding cloth. 11

3.3 Rapid Disinfection A low level disinfection process should only be considered where High Level Disinfection and Sterilization processes are not practical. DISINFECTANT WIPE (LOW LEVEL DISINFECTION) - McGRATH MAC EMS with McGRATH 3.6V EMS Battery removed - McGRATH MAC EMS with McGRATH 3.6V EMS Battery fitted - McGRATH 3.6V EMS Battery A Chemical Compatibility List is available which lists wipes that have been approved by Aircraft Medical as compatible and will cause no physical degradation to the McGRATH MAC EMS. Aircraft Medical make no claims regarding the efficacy of any of the disinfectants listed. Please consult the disinfectant manufacturer s instructions and guidelines. Ensure that the chemicals are not harmful to the patient or user and that they have been approved by the relevant decontamination authority. Ensure that all surfaces of the device are covered, even if no visible soiling is present. Systematically work from top to bottom: 1. Monitor 1. Monitor: Ensure the wipe gets into the various grooves around the screen. 2. Monitor Hinge 2. Monitor Hinge: Rotate the monitor to the upright position. Feed the wipe into the space between the monitor and handle to ensure effective penetration. Rotate the monitor to its opposite position and repeat. 3. Battery Cover: Ensure that the join between the battery module and the handle are thoroughly treated with the wipe. 4. Heel Area: Take particular care in ensuring that the small metal clip feature is clean, in particular the internal corner between the clip and the surrounding plastic body. 5. Camera: locally scrub around the camera lens to ensure that the interface between the metal CameraStick TM and the camera lens is clean. 3. Battery Cover 5. Camera 4. Heel Area 12

3.4 High-Level Disinfection AUTOMATED CHEMICAL DISINFECTOR McGRATH MAC EMS with McGRATH 3.6V EMS Battery removed The McGRATH MAC EMS is suitable for reprocessing in STERIS SYSTEM 1E. Follow STERIS instructions for processing using SYSTEM 1E. HIGH-LEVEL DISINFECTANT IMMERSION McGRATH MAC EMS with McGRATH 3.6V EMS Battery removed Ensure that the device has been thoroughly cleaned, rinsed and dried prior to disinfection. Disinfect the device in accordance with the high-level disinfectant manufacturer s instructions The process below has been approved by Aircraft Medical using ASP Cidex OPA: protective equipment, fill the receptacle with sufficient prepared disinfectant solution so as to ensure complete immersion of the device. Carefully immerse the device in the solution in such a way as to displace any trapped air within the device; it is important to ensure that the solution reaches all surfaces. Place the lid on the receptacle and leave for 12 minutes. rinse receptacle. Rinse thoroughly with sterile water of suitable microbiological quality. Remove device from rinse solution and drain. A Chemical Compatibility List is available which lists other high-level disinfectants that have been approved by Aircraft Medical as compatible and will cause no physical degradation to the McGRATH MAC EMS. Aircraft Medical make no claims regarding the efficacy of the other disinfectants listed. Please consult the disinfectant manufacturer s instructions and guidelines. Ensure that the chemicals are not harmful to the patient or user and that they have been approved by the relevant decontamination authority. 13

3.5 Sterilization STERRAD McGRATH MAC EMS with McGRATH 3.6V EMS Battery removed McGRATH MAC EMS with McGRATH 3.6V EMS Battery fitted The McGRATH MAC EMS is suitable for reprocessing in STERRAD 50/100S/200/NX/100NX. Follow Advanced Sterilization Products instructions for processing using STERRAD ETHYLENE OXIDE McGRATH 3.6V EMS Battery The McGRATH 3.6V EMS Battery is suitable for reprocessing by Ethylene Oxide sterilization (EtO). Use local guidelines for EtO processing where available. If local guidelines do not exist or for further information on Ethylene Oxide sterilization, refer to ISO11135-1 for guidance. 14

4 Storage and Transportation The following precautions should be taken when storing and transporting the device: Ensure that contaminated devices are placed individually in suitable containers in accordance with local hospital practice. Containers used to transport devices should be durable and suitable for decontamination. Decontaminated devices should be packaged immediately upon completion of the drying phase and should be stored in accordance with local guidelines. 15

5 Troubleshooting IF ANY COMPONENTS BECOME LOOSE, PHYSICALLY DAMAGED OR FIT POORLY, UNDER NO CIRCUMSTANCES USE THE EQUIPMENT. INSTEAD RETURN IT TO YOUR AIRCRAFT MEDICAL AGENT OR DISTRIBUTOR FOR REPAIR OR REPLACEMENT. No image shown on screen If when switched on, there is no display on the screen Poor picture quality If the image displayed on the screen is blurred or fuzzy of the CameraStick with a clean, soft wipe. If none of the above achieves positive results, return the unit to your Aircraft Medical agent or distributor for diagnostics and repair. 16

6 Warranty The McGRATH MAC EMS is supplied with a 12 month manufacturer s warranty. the manufacturer s warranty. procedures documented in the Operator s Manual. disinfection state before transportation. For full terms of warranty, please contact your Aircraft Medical agent or distributor. 17

Registered Office: 10 Saint Andrew Square Edinburgh EH2 2AF United Kingdom www.aircraftmedical.com McGrath and Aircraft are registered trademarks of Aircraft Medical Ltd CameraStick is a trademark of Aircraft Medical Ltd International patents pending. Aircraft Medical Ltd 2013