Data sheet Thermostatic expansion valves for ammonia Type TEA Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat. Therefore the valves are especially suitable for liquid injection in dry evaporators where the superheat at the evaporator outlet follows the evaporator load proportionally. Features Large temperature range: 50 to +0 C Can be used in both freezing and refrigeration systems. Interchangeable orifice assemblies Interchangeable thermostatic element Rated capacities from.5 to 295 kw, to 85 tons (TR). External superheat setting Can be matched to all evaporators to give optimum evaporator utilization. Patented double contact bulb Fast and easy to install. Good temperature transfer from tube to bulb. Classification: DNV, CRN, BV, EAC etc. To get an updated list of certification on the products please contact your local Danfoss Sales Company. Materials Valve housing made of GGG40. Gaskets are non asbestos Technical data Refrigerant R77 (Ammonia) Evaporating temperature range D: 50 to 0 C P: 20 to +0 C Capillary tube length 5 m Connection for external pressure equalization 4 in. or 6.5 / 0 mm weld nipple. An 8 mm self-cutting union can also be used. Max. bulb temperature 00 C Max. working pressure PS/MWP = 9 bar Max. test pressure 2 bar Danfoss DCS (MWA) 209 DKRCI.PD.AJ0.A.02 520H7428
Identification The thermostatic element has a white label attached to its top. The colour refers to the refrigerant for which the valve is designed: R 77 (Ammonia). Element label Orifice assembly marking The orifice assembly is marked with valve type (TEA 20) rated capacity (8 TR = 28 kw) refrigerant R77 (NH ) date stamp Ordering Type and rated capacity in tons Rated capacity ) Connection weld flanges (TR) kw in. in. TEA 20, range: 50 to 0 C TEA 20- TEA 20-.5 7 0.5 28 42 70 TEA 20, range : 20 to +0 C TEA 20- TEA 20-.5 7 0.5 28 42 70 TEA 85, range: 50 to 0 C TEA85-5 90 295 TEA 85, range: 20 to +0 C TEA85-5 90 295 Inlet Outlet Assembled valve 068G6000 068G600 068G6002 068G600 068G6004 068G6005 068G6006 068G67 068G6 068G64 068G68 068G69 068G640 068G65 068G6007 068G6008 068G6009 068G64 068G642 068G64 Separate strainer 2 ) 006-0042 006-0042 006-0048 006-0048 Code no. Separate orifice assembly 068G2050 068G205 068G2052 068G205 068G2054 068G2055 068G2056 068G2050 068G205 068G2052 068G205 068G2054 068G2055 068G2056 068G2057 068G2058 068G2059 068G2057 068G2058 068G2059 ) The rated capacity is the valve capacity at 5 C evaporating temperature and +2 C condensing temperature. The capacities are based on approx. 4 K subcooling ahead of valve. 2 ) The filter is supplied with gaskets, bolts and nuts. Separate thermostatic element 068G250 068G252 068G250 068G252 Note: Subcooling of the liquid in front of the valve is essential for the function of the valve. Lack of subcooling will lead to malfunction of the valve, and increased wear on the orifice. Danfoss DCS (MWA) 209 DKRCI.PD.AJ0.A.02 520H7428 2
Capacity in kw, range 50 to 0 C Type and rated capacity in tons (TR) R 77 (NH ) 2 4 6 8 0 2 4 6 2 4 6 8 0 2 4 6 TEA 20- TEA 20- TEA 85-2. 4. 5.9 0.5 5.7 40.7 69. 4 80 8. 4. 22.. 5 92.8 5 28 Evaporating temperature 0 C. 6.5 6.7 9.5 66. 0 80 285.7.2 29.7 4 7 22 204 20 4. 8. 2. 20.2 2.0 48. 80.9 4 22 4 4..0 2.5 4. 5.8 86. 45 28 66 9.0.5 22.4 6. 54.7 90.2 5 250 84 9. 4.0 2. 7.2 56.4 9.7 57 95 2.7 7.8.4 5.8 8 45 22 Evaporating temperature 0 C.0 6.0 9. 5. 60.5 0 69. 6.8 0. 7. 86 29.6.2 0.2 4 75. 22 204 4 4.0 2.0 20.0.7 47.7 79. 4 22 7 8. 20.8. 50.0 8. 40 2 55.0 2.5 4. 52. 8 45 244 72 TEA 20- TEA 20- TEA 85-2.2 4. 6.5.0 2 4 72. 6 80 Evaporating temperature 20 C 0.8 8 45 22 57.6 9 6 244. 6.2 2 7.2 0 74 267. 0.0 6.5 9.5 65.7 09 80 279.5 6.9 0.4 7.2 27. 4 86 29.7 7. 0.6 7.7 4.0 72. 6 92 02 Evaporating temperature 0 C 2.0 4. 6.2 0. 6. 2 40.7 4 74 2.2 6.9. 45.4 7 28 92 2.4 2. 9.8 0.2 4 80.9 40 209 7.9..4 52. 8 45 22 2.8 5.5 8..7 22. 54.7 90.2 5 2 4..7 57.0 9 57 244 TEA 20- TEA 20- TEA 85- Evaporating temperature 40 C.. 2.8 9.2 2.0 52. 86.8 4.7.5 4.0 5.5 58.2 96.5 5.9.8 5.7 5. 8.4 04 6 2.0 4.0 6.0 0. 6. 40.7 65. 0 74 2.2 6.4 0.6 6.9 4.0 6 80 2..0 27. 4 72. 22 86 Evaporating temperature 50 C.2 2.4.7 6.0 9. 9.5 66. 04. 2.7 4. 0.5 5.7 4.6 72..4 2.8 4. 7..0 6.9 46.5 77.8 22.5.0 7.6.6 29.7 4 8.9 28.6. 7.9 2.2 9.2.4 5.8 86. 4.7. 8. 2.8 54. 89.6 40 ) Subcooling t = 4K ahead of the valve. Example Given: Refrigerant = R 77 (NH ) Evaporator capacity Q e = 265 kw (75. TR) Evaporating temperature t e = 20 C (~p e =.9 bar) Condensing temperature t c = +2 C (~p c = 2.4 bar) Subcooling t = 4K If the pressure drop p across pipelines, etc. is calculated, for example, as 0.5 bar, the effective pressure drop across the thermostatic valve becomes p = p c p e p p = 2.4.9 0.5 = 0 bar. Now, from the capacity table at an evaporating temperature t e = 20 C and p = 0 bar, the capacity is 267 kw. The column on the far left of this point gives the valve designation:. The ordering table gives the code no. for : 068G6009. Generally, the maximum capacity of a valve is approx. 20% higher than the value given in the table. If a different capacity is subsequently required, a separate orifice assembly with a suitable rated capacity can be ordered to replace the one fitted in the installed valve. Danfoss DCS (MWA) 209 DKRCI.PD.AJ0.A.02 520H7428
Capacity in kw, range 20 to +0 C Type and rated capacity in tons (TR) R 77 (NH ) 2 4 6 8 0 2 4 6 2 4 6 8 0 2 4 6 TEA 20- TEA 20- TEA 85-4.7.6 29. 4 4 96.4 6.5 7.8 6.0 27. 9.6 66.2 06 79 257 Evaporating temperature +0 C.9 9. 9.0. 45. 74.6 22 205 297 4. 8. 0.4 49.2 8. 222 28 4.6.4 22.2 52.2 86.4 4 26 5 9.2 2.2 2.4 5 90.9 50 248 74 9.6 2 40. 57.7 9 58 259 92.5 25.4 59.8 98. 64 268 408 2.7 5.9 2. 20.7 0.2 50.7 8 7 200.4 6.5 28. 40.2 65.9 06 8 258 Evaporating temperature +20 C.9 9.6 9..5 4 7.8 20 202 296 8. 0.8 48.8 80.0 2 29 26.7 22.2 6.5 52.0 8 4 2 5 9. 2.5 2.4 8.4 5 89.7 49 245 72 9.5.2 40. 57.2 9.7 56 90 5..9 25.4 4.6 59. 97.2 6 265 406 Evaporating temperature +0 C Evaporating temperature 0 C TEA 20- TEA 20- TEA 85-5. 6. 2.5 2. 0.9 84.0 40 200. 8. 7.0 27.8 9.5 6 04 78 255.8 9.8 9.. 4 72. 8 98 292.0 20.7.7 47.9 78.2 29 24 2 2.0 22.0 6.0 5. 8.4 9 228 46 4.7 9.0 2.8 2.2 7.9 5.9 8 47 24 67 9.5.5 24. 9.6 56. 92.0 5 25 85 4. 2 5 9 60 26 40 6. 2.8.4 5.7 82.0 9 96.2 6.4 6.8 27. 8.4 62. 0 72 248.7 7.2 0.0 0. 4 69.8 4 92 285 4. 7.9.2 20..0 46.7 76.0 26 208 4 4. 8.4 2. 2.7 4 8. 5 22 9 4.6 8.9 2 7.2 52.7 85.9 4 25 60.6 9.0 5 90.0 5 246 78 9.7 2 40.5 5 9.7 57 95 TEA 20- TEA 20- TEA 85-. 6. 24.7 6.9 59.7 97.0 65 29 Evaporating temperature 0 C.6 6.9 0.0 27.8 67. 85 276.9.2 9. 0.4 45. 7.6 22 202 06 8. 2. 4 79.0 26 4.6 5.5 40 229 52 4.6 9.0.5 6. 54.0 87.9 47 24 7 4. 7.8 56. 9.7 54 25 88 5.4 8.4.6 2.0 2.2 56.9 92.0 58 20 Evaporating temperature 20 C.2 6.2 5.4 24.0 6.7 64.6 07 78 267.5 6.8.0 7.0 26.5 40.4 7.0 8 96 297.8 7..9 8. 2 7 28 2 2 4.0 7.8 2.5 0.4 46. 8.4 6 224 45 8.2.0 2.0 4 8 44 25 64.4 2..4 50.9 89.5 50 245 8 ) Subcooling t = 4K ahead of the valve. Danfoss DCS (MWA) 209 DKRCI.PD.AJ0.A.02 520H7428 4
Design/ Function TEA 20 / TEA 85. Thermostatic element (diaphragm) 2. Orifice assembly. Valve body 4. Superheat setting spindle (see Instructions ) 5. Ext. pressure equalizing connection 0. Separate outlet orifice (for TEA 20- only) Danfoss 68G68 General TEA is equipped with interchangeable orifice assembly and thermostatic element. TEA is built up of three interchangeable main components: Thermostatic element () Orifice assembly (2) Valve body (), with flange connections The valve has external equalization. A separate outlet orifice assembly (0) is for use with TEA 20- (.5 kw) only. The double contact bulb gives fast and precise reaction to temperature changes in the evaporator suction line, even with much reduced evaporator load. It also makes fitting the bulb quick and easy. The valves are able to withstand the effects that normally occur with hot gas defrosting. The movement of the setting spindle is transferred by a gearwheel mechanism that ensures smooth superheat setting. The throttling section of the orifice assembly has a long operating life, the valve cone and seat being made of a special alloy steel with particularly good wear qualities. Note: The TEA is not able to close completely tight. Consequently a solenoid valve is needed to shut off liquid supply when systems stops. Dimensions and weights Danfoss 68G69 Type H H 2 H H 4 L B Weight Excl. strainer Incl. strainer Excl. strainer Incl. strainer mm mm mm mm mm mm mm kg kg TEA 20 94 8 25 96 0 64 80 2..0 TEA 85 04 7 5 06 25 99 95.0 Danfoss DCS (MWA) 209 DKRCI.PD.AJ0.A.02 520H7428 5
Danfoss DCS (MWA) 209 DKRCI.PD.AJ0.A.02 520H7428 6