BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

Similar documents
Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

FIRE PREVENTION AND PROTECTION FACT SHEET

Risk Management Resources

Model Policy On Portable Fire Extinguishers (Ontario Version)

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Fire Safety. Version 1.0

Fire Prevention Plan Program

FIRE PROTECTION PROGRAM

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Board Policy 6819 Fire Safety and Prevention Plan

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

GUILFORD COUNTY SCHOOLS

WSU-TFREC Fire Safety Training

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1

2010 FIRE CODE OF NEW YORK STATE

ADMINISTRATIVE SERVICES MANUAL

Fire Safety Safety Program

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Safety Manual Section 7 Fire/Life Safety

Emergency Action Plan Leading the Fight

HAWAII ADMINISTRATIVE RULES DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH GENERAL INDUSTRY STANDARDS

INSPECTOR I SKILLS ADMINISTRATION

Safety Manual: Emergency Response

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP

FIRE SAFETY PRACTICES AND PROCEDURES

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Stillwater Area Community Services Center Inc.

Fire Prevention Program

Document Number: HSP Prepared by: Jim Landry Manager Approval: Hillary Garner HEALTH AND SAFETY PROGRAM HSP 506 FIRE PREVENTION PLAN

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

Institute for Plasma Research Welcomes you all on

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Emergency Action and Fire Prevention

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

SERT FIRE ELEMENTS & HAZ MAT

Fire Prevention Plan

Fire Prevention Plan

Emergency Planning and Preparedness

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

Risk Management Department. Fire Extinguishers

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Fire Prevention Plan for Campus Services Building 1630 Musketeer Drive

Fire Prevention Plan

Emergency Evacuation Plan South Patterson Building (SPB)

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

A Safe Workplace A Workplace Safety and Health Manual for Your Community Section: II-B Subject:

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

Fire Prevention Plan for Residence Life 1625 Musketeer Drive

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

E4218 Fire Extinguisher Basic Training. Leader s Guide

Fire Safety Plan Information. For Construction and Demolition Sites

SCALES NW EMERGENCY ACTION PLAN

Evacuation Fire Safety Program

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Fire Prevention Plan for Bellarmine Parish Center 3832 Ledgewood Avenue

Agency for Health Care Administration

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Family Foster Home Fire Safety Evaluation Checklist Instructions

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

2. How to trace out fault in an electrical circuit? Step 1 - Power Down

Emergency Action Plans and Fire Prevention Plans. Are employers required to have Emergency Action Plans and/or Fire Prevention Plans?

FIRE SAFETY FOR OFFICE WORKERS

INFORMATION BULLETIN

Emergency Evacuation Plan. Kettering Labs. School of Engineering

ABSTRACT. State adoption is not required, See Paragraph V. Directorate of Compliance Programs. 200 Constitution Avenue, NW Washington, DC 20210

CHAPTER 9 FIRE PROTECTION AND PREVENTION PROGRAM

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

Fire Prevention Plan for Cintas Center 1624 Musketeer Drive

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

Fire Prevention Plan for Xavier Armory 3908 Winding Way

Progressive Safety Services LLC 2

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Fire Safety Handbook

Element 14.7 Fire Prevention and Control 2018

Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

Portable Fire Extinguishers

Fire Prevention Plan for

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Transcription:

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 1. Purpose This policy sets forth requirements for preventing and detecting fires, sounding an alarm, and suppressing fires. Fire protection requirements may vary from one location to another based on location size, type of equipment available, local jurisdictional requirements, and capability of fire departments and local mutual aid. 2. Scope This policy applies to all personnel and covers safety requirements for fire emergencies, such as OSHA Emergency Action Plans, OSHA Fire Prevention Plans, and requirements for fire detection and extinguishing systems. Excluded are inspection, testing, and maintenance requirements which are contained in USPL STP 32-102, Inspection and Testing of Systems. The following sections of the safety manual contain related policies and should be consulted for additional requirements and guidance: Combustible and Flammable Liquid Storage and Handling Housekeeping Hazard Communication (HAZCOM) Smoking HAZWOPER Hot Work Bulletin Board Postings 3. Minimum Requirements Minimum Requirements Supporting Documentation 1. Under no circumstances shall personnel be required to perform fire fighting. Section 6 2. Employees shall immediately report all fire emergencies as instructed in the location s response plan. 3. Emergency telephone numbers shall be posted near telephones or on bulletin boards at each facility. Section 6 Section 9 4. All portable fire extinguishers shall be readily accessible in conspicuous locations. Section 10 5. Employees who are designated to use fire fighting equipment shall be provided with training in the use of the appropriate equipment. Section 10

Page 2 of 6 BP U.S. Pipelines and Logistics (USPL) Safety Manual 4. Definitions Class A fire Fire in ordinary combustible materials, such as wood, cloth, paper, rubber, and many plastics. Class B fire Fires in flammable liquids, combustible liquids, petroleum greases, tars, oils, oil-based paints, solvents, lacquers, alcohols, and flammable gases. Class C fire Fires that involve energized electrical equipment. Class D fire Fires in combustible metals, such as magnesium, titanium, zirconium, sodium, lithium, and potassium. Detection equipment Equipment that automatically detects heat, flame, UV light, products of combustion, or other conditions which may indicate the presence of a fire or explosion hazard, and causes automatic actuation of alarm or suppression systems.. Emergency Response Plan Guidelines to quickly, safely, and effectively respond to a spill. USPL uses this term to generally refer to plans prepared for geographic pipeline areas. Facility Response Plan A facility-specific procedure for prevention of, preparedness for, and response to oil discharges. USPL uses this term to generally refer to plans prepared for terminals and facilities. Fire alarm system A system of components and circuits arranged to monitor and annunciate the status of signal initiating devices and to initiate the appropriate response to those signals. Fire protection Measures and practices for preventing or reducing injury and loss of life or property by fire. Fixed extinguishing system A permanently installed system that either extinguishes or controls a fire at the location of the system. The system may include fire detection (e.g. manual or automatic), activation devices, delivery equipment (e.g. pumps, piping, foam chambers, spray nozzles), and an extinguishing agent (e.g. water, foam, dry chemical, gas). Incipient stage The beginning stage of a fire when it can be controlled or extinguished by portable fire extinguishers or standpipe or small hose systems without the need for protective clothing or breathing apparatus. Sprinkler system A network of overhead piping to which sprinklers are attached in a systematic pattern for the purpose of automatically discharging water or foam upon detection of fire, usually from heat or optical detectors. Standpipe system An arrangement of piping, valves, and hose connections located in such a manner that water can be discharged in streams or spray patterns through attached hose and nozzles, for the purpose of extinguishing a fire. Structural fire-fighting The activities of rescue, fire suppression, and conservation of property from fires involving buildings, structures, vehicles, vessels, aircraft, or other large objects. 5. Roles and Responsibilities 5.1. Supervisor A. Confirm that all fire protection equipment on site is maintained per the requirements of USPL STP 32-102. B. Provide instruction to employees for reporting emergencies. C. Schedule drills and exercises, document the performance, and address noted deficiencies.

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 3 of 6 D. Confirm that the elements of the OSHA Fire Prevention Plan are included in the facility response plan, emergency response plan, or other similar plan and that the plan is reviewed annually at a minimum and updated if necessary. Note that updates to the plan should occur following any modification to the fire protection system. E. Conduct emergency evacuation drills at least annually. 6. General Requirements 6.1 Personnel Requirements A. Under no circumstances shall personnel be required to perform fire fighting. 1. If an employee chooses to fight a fire, it shall only be attempted while the fire is in its incipient stage. B. Employees response to fires shall be in accordance with the site emergency response plan. At a minimum, employees shall immediately report all fire emergencies as instructed in the location s response plan. 6.2. Means of Egress A. Each exit shall be clearly visible and marked by a sign reading Exit. B. Exit routes shall be free and unobstructed. No material or equipment may be placed, either permanently or temporarily, within the exit route. C. No lock or fastening shall be permitted that prevents free escape from the inside of any building while occupied. D. Each doorway or passage along an exit access that could be mistaken for an exit shall be marked Not an Exit or similar designation, or be identified by a sign indicating its actual use (e.g. closet). E. Each exit route door shall be free of decorations or signs that obscure the visibility of the exit route door. F. Each exit route shall be adequately lighted so that an employee with normal vision can see along the exit route. 7. OSHA Fire Prevention Plan A. An OSHA fire prevention plan shall be in writing, be kept in the workplace, and be made available to employees for review. B. The minimum elements of the plan shall include: 1. A list of all major fire hazards, proper handling and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard. 2. Procedures to control accumulations of flammable and combustible waste materials. 3. Procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent the accidental ignition of combustible materials. 4. The name or job title of employees responsible for maintaining equipment to prevent or control sources of ignition or fires.

Page 4 of 6 BP U.S. Pipelines and Logistics (USPL) Safety Manual 5. The name or job title of employees responsible for the control of fuel source hazards. C. These required elements may be contained within other plans such as the Facility Response Plan. 8. OSHA Emergency Action Plan The requirements of the OSHA Emergency Action Plan are included in the facility response plan, emergency response plan, or spill response plan. 9. Fixed Fire Detection and Extinguishing Systems All fixed fire detection and extinguishing systems shall be inspected and tested in accordance with USPL s STP 32-102, Inspection and Testing of Systems. 9.1. Emergency Alarm Systems A. The need for fire alarm systems shall be in accordance with local requirements. Consideration should include the NFPA requirement In every building of such size, arrangement, or occupancy that a fire itself could not provide adequate occupant warning, fire alarm systems shall be provided where necessary to warn occupants of the existence of fire. B. Supervisors shall explain to employees the preferred means for reporting emergencies (e.g., manual alarm, radio, telephone, verbal, etc.) typically during Facility Response Plan reviews. C. Emergency telephone numbers shall be posted near telephones or on bulletin boards at each facility. 9.2. Fire Drills for Locations with Standpipe and Hose Systems A. Locations with a water-based fire protection system shall conduct regular fire drills, scheduled at least annually. Consider including local responders in drills. B. The drills shall simulate the various procedures to be implemented by personnel in an actual fire or other emergency. Drills and related training exercises shall cover, at a minimum, the following topics: 1. Capabilities and limitations of the standpipe system and its components. 2. Fire pump operation and water deliverability. 3. Personal protective equipment. 4. Foam-making requirements, supplies, and limitations where foam is available. 5. Manpower allocations to fight fire. 6. Fire situation chain of command. 7. Use of monitors and stationary equipment. C. The Supervisor shall prepare a written report that critiques the performance of participants in the drill, noting strengths and weaknesses.

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 5 of 6 10. Portable Fire Extinguishers 10.1. Placement and Marking 11. Training A. All portable fire extinguishers shall be readily accessible in conspicuous locations. 1. In areas where extinguishers are blocked from view, their locations shall be marked with conspicuous signs or symbols. B. Portable fire extinguishers for employee use shall be selected and distributed based on the classes of anticipated workplace fires and on the size and degree of hazard that would affect their use. Note: The requirements for placement of extinguishers are for inside buildings. Placement of extinguishers outside buildings is at USPL s discretion unless required by local jurisdictions. 1. Class A rated extinguishers shall be placed so that no point in the protected area is more than 75 feet from an extinguisher. 2. Class B rated extinguishers shall be placed so that no point in the protected area is more than 50 feet from an extinguisher. 3. Class C rated extinguishers shall be available in areas where energized electrical equipment is located. C. Portable hand extinguishers shall be placed along normal paths of travel for immediate availability in case of fire. D. Portable wheeled fire extinguishers, e.g. 125 lb. Purple-K, are recommended to be placed near gasoline loading racks where other fire suppression systems are not present. E. Portable extinguishing equipment maintained in a separate housing shall be accessible year round through good housekeeping practices. F. Fire fighting foam supplies shall be stored above their freezing point. G. Extinguishers for automobiles and trucks shall be conveniently installed inside the car or cab. Exception: Extinguishers weighing more than 4 pounds should be mounted outside the truck cab (e.g., in the truck bed or on the rear end of the trailer). Note: Extinguishers for vehicles, equipment, or other locations subject to vibrations that may cause packing of dry chemical agents should be mounted in a horizontal position so that the hose is on the upper side of the shell. H. Extinguishers subject to temperatures below 20 F shall be cartridge-operated only. The expellant in the cartridge shall be nitrogen if these temperatures are to be expected. I. Fire extinguishers, once used, shall be recharged as soon as possible and returned to their original location. 1. While an extinguisher is being recharged, a spare extinguisher shall be temporarily installed until the regular extinguisher is returned to service. A. Where portable fire extinguishers are provided, employees will be provided an educational program to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.

Page 6 of 6 BP U.S. Pipelines and Logistics (USPL) Safety Manual B. Where portable fire extinguishers are provided and employees are designated to use them, hands-on fire extinguisher training shall be provided. Note: Virtual fire extinguisher training can fulfill this requirement. C. Employees who are designated with roles in the operation and maintenance of fire protection equipment shall be provided with training in the use and maintenance of the equipment as required by the manufacturer. D. Employees designated with roles in Fire Prevention and Emergency Action plans shall receive training on those responsibilities. 12. References 1. National Agency, NFPA 10, 13. 2. Occupational Safety and Health Administration, Department of Labor, 29 CFR 1910.35 (Compliance with NFPA 101-2000, Life Safety Code), 1910.37 (Maintenance, safeguards, and operational features for exit routes), 1910.38 (Emergency action plans), 1910.39 (Fire Prevention Plans), 1910.156 157, 1910.164 (Fire Detection Systems), 1910.165 (Employee Alarm Systems).