SPECIFICATIONS. Contents List

Similar documents
EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Illuminated Stopper Station Push Button

Addendum for STI-6406 with Dual Access Control

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Exit Stopper. STI-6400 Series

MANUAL RESET ALARM RELEASE

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Exit Stopper. STI-6400 Series

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

TS93 EMF SERIES. INSPK NO Rev.03/10

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

! WARNING. Before using product, read and understand instructions.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MANUAL RESET ALARM RELEASE

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

INSTALLATION INSTRUCTIONS

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Stopper II Heated Enclosure

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

ENERVEX RSV CHIMNEY FAN

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

ISIS SAFETY SYSTEM Installation guide

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

SC Installation, Operation & Application Guide

Powers Controls Low Temperature Detection Thermostat

Booster Power Supply Manual

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

FireNET Fire Alarm Control Panel Installation Manual

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Magna-Sygg Model K Operations and Maintenance Manual

ELECTRONIC COMMUNICATING THERMOSTAT

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

Installation Instructions Air Pump

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

OptiStile 220. Swinging Barrier Arm Optical Turnstile

Installation Instructions

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

Panasonic KV-S5046H/S5076H Scanner Maintenance

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Installation Instructions for W2H Series Signals

MBCE-110/230UV Flame Sensor Module

TS93 EMR WITH SMOKE DETECTOR

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SC Installation, Operation & Application Guide

180 Degree Ceiling Mounted Occupancy Sensors

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Installation Guide for models:

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

CM800 Emergency Call System

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

DH100ACDCI Ionization Air Duct Smoke Detector

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

TYPE C: RETURN AIR UNDER POSITIVE PRESSURE FROM SEPARATE BLOWER

Installation Guide for models:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

FPC-02 Series. Installation and Operating manual

MANUAL RESET ALARM RELEASE BOX

DH100ACDCI Ionization Air Duct Smoke Detector

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Powers TM Controls ET 134 Line Voltage Room Thermostats

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Installation Instructions

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SC Installation, Operation & Application Guide

TS40 Product Assembly & Service Information Manual

Transcription:

INSTALLATION INSTRUCTIONS FOR PB-SA PUSH BUTTON SYSTEM ABORT The information contained in this installation instruction is a quick reference guide. For detailed system information refer to the panel manufacturers installation manual. This instruction is generic and will not address specific programming procedures. I. INSTALLATION NOTE: This push button has been tested according to UL2017. It is important to read, understand and follow all instructions provided with this product. Non-fire alarm initiating devices are listed in UL category UEHX. It is the installer s responsibility to comply with NFPA72 and 101, NEC, mounting specifications according to ADA and other applicable fire and electrical codes. To avoid electrical shock, DO NOT attempt to install this product when power is on. To avoid possible confusion with fire alarm initiating devices, do not mount a red stopper station near a manual fire alarm initiating device. ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 ½ ft.) or greater than 1.37m (4 ½ ft.) above finished floor service. After installation and testing are completed, provide a copy of this manual to all personnel responsible for testing and maintenance of this product. II. SPECIFICATION & CONTENT LIST: SPECIFICATIONS Switch Rating (2 Form C contacts) 3Amps @ 30VDC 10Amps @ 125/250 VAC, ½ HP 6Amps @ 30VDC Dimensions 3.25"W X 4.87"H X 1.62"D (with back box included: 3.18"D) Weight Approximately 9.6 ounces Contents List Quantity: Descriptions: 1 Button and Switch Assembly 1 Reset Key 1 Allen Head Screw #8-32 x 3/8 1 Allen Wrench 2/32 4 Screw 3.5mm x 13mm 2 Screw #6-32 x 1 1 Ground Screw 4 #6 x 1 ¼ SS SMS 4 Plastic Screw Anchor 1 Surface Backbox III. INSTRUCTIONS: Housing Removal... Page 2 Backbox Preparation... Page 3 Wire Connections... Page 4 Installation.. Page 5 Key Reset Procedure.. Page 6 Product Dimensions... Page 7 Page 1 of 7

Housing Removal BUTTON AND SWITCH ASSEMBLY SWITCH HOUSING SCRREW ALLEN HEAD #8-32 X 3/8 ALLEN WRENCH Remove screw. Pull bottom of housing out and lift up until tabs are released from slots in the button and switch assembly. Page 2 of 7

Backbox Preparation 1.5.75 FIELD DRILLING FOR CONDUIT ENTRY IS REQUIRED. LOCATIONS SHOWN ALSO APPLY TO OPPOSITE, PARALLEL SIDE. 2.375.75 TOP BOX MUST BE INSTALLED WITH TOP FACING UPWARD AS SHOWN H J H SWITCH BACKPLATE MOUNTING BOSS H (4 PLACES J GROUND SCREW BOSS J H J THESE (4) HOLES MUST BE DRILLED OUT USING A 3/16 DRILL BIT H Page 3 of 7

Wire Connections COM NC NO CONTACT SET 1 CONTACT SET 1 CONTACT SET 2 COM NC NO CONTACT SET 2 STRIP 3/8 CORRECT METHOD OF INSERTING MULTIPLE LEADS (1 WIRE EACH SIDE OF SCREW) INCORRECT METHOD OF INSERTING MULTIPLE LEADS (BOTH WIRE ON ONE SIDE OF SCREW) Page 4 of 7

Installation SURFACE BOX SCREW #6 X 1 ¼ (4) PROVIDED DRILL (4) 5/32 DIA. HOLES ANCHOR (4) PROVIDED GROUND SCREW BUTTON AND SWITCH ASSEMBLY SCREW SELF TAPPING (4) PROVIDED GROUND SCREW TYPICAL FLUSCH MOUNT SINGLE GANG OUTLET BOX #6-32 X 1 SCREW (2) PROVIDED BUTTON AND SWITCH ASSEMBLY Page 5 of 7

Key Reset Procedure KEY-TO-RESET SLOT LOCATED UNDER BUTTON VIEW IN DIRECTION OF ARROW PUSH IN UNTIL BUTTON POPPS UP ALIGN SLOT IN KEY (CONCAVE SIDE UP) WITHY 2 SLOTS UNDER BUTTON TURN-TO-RESET PROCEDURE TO RESET, TURN BUTTON IN DIRECTION OF ARROW UNTIL BUTTON POPS UP Page 6 of 7

Dimension INSTALLATION NOTE: ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 ½ ft.) or greater than 1.37m (4 ½ ft.) above finished floor service 3.25 1.62 1.25 4.87 3.25 1.62 4.87 1.56 3.18 Page 7 of 7