Proceedings Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor

Similar documents
Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Proceedings Enhanced Characteristics of Nondispersive Infrared CO2 Gas Sensor by Deposition of Hydrophobic Thin Film

which allows for precise measurements of the fiber dimensions. Supplementary

LAMINATION AND CHARACTERIZATION OF A POLYETHYLENETEREPHTHALATE FLEXIBLE MICRO HEAT PIPE

Proceedings Soft Triboelectric Band for Sensing of and Energy Scavenging From Body Motion

Development of the Micro Capillary Pumped Loop for Electronic Cooling

ENHANCED VISION - INFRARED 1

On the Influence of Shade in Improving Thermal Comfort in Courtyards

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

SILICON SENSOR ACTIVITIES AT SINTEF MINALAB. Marco Povoli, Angela Kok, Ozhan Koybasi

The Design of MLX90621 Based Intelligent Lighting Control System Hui-jiao Wang*, Meng-meng Liu and Cong-cong Shi

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Thermal Performance of a Loop Thermosyphon

New emerging technologies for smart textile application

Separation of the Pyro- and Piezoelectric Response of Electroactive Polymers for Sensor Applications

IMB-CNM Presentation. Instituto de Microelectrónica de Barcelona. Centro Nacional de Microelectrónica IMB-CNM (CSIC)

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

SILICON V-GROOVE ALIGNMENT BENCH FOR OPTICAL COMPONENT ASSEMBLY

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Overview of VTT s activities in photonics, semicon, MEMS and printed intelligence

Keywords: ECM, suction tool, auxiliary electrode, current density, machining characteristics

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer

March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

A Method for Predicting the Matric Suction of Unsaturated Soils with Soil Color Recognition

New Generation of UV, IR and γ - ray sensors with Carbon Nano-Tubes (CNT)

Heated tools. Semiconductor equipment

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

Available online at ScienceDirect. Physics Procedia 67 (2015 )

MITSUBISHI ELECTRIC ANNOUNCES DEVELOPMENT OF 5.6 W 213 nm DEEP ULTRAVIOLET SOLID STATE LASER

Thermal analysis of flat evacuated glass enclosure for building integrated solar applications

Design of Gear Defect Detection System Based on Machine Vision

Multi-sensor System For Indoor Environment Monitoring Zheng-yu Wanga, and Xiao-ru Zhangb

HARSH ENVIRONMENT ELECTRONICS AND SENSORS APPLICATIONS

Features of Shinko advanced package and Optical sensor developed with Fraunhofer ENAS. Yuichiro Shimizu SHINKO ELECTRIC INDUSTRIES CO., LTD.

Experimentation of Heat Pipe Used In Nano-Fluids

Development of a Capacitive Ice Sensor to Measure Ice Growth in Real Time

EXPERIMENTAL STUDY ON THE LOOP HEAT PIPE OPERATING UNDER HORIZONTAL ORIENTATION

PRESS RELEASE. K 2016: 20th International Trade Fair for Plastics and Rubber WACKER Presents New Applications for Silicone Films.

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

A New Micromachined Sensor Platform. Debra J. Deininger Synkera Technologies Inc. June 6, 2007

Pushing the limits in R2R production of Printed Electronics. Andrea Glawe / Frank Schäfer KROENERT GmbH & Co KG

Research of High Sensitivity Uncooled Infrared Detector Array

MEMS THERMAL MASS FLOW METERS FOR HUMIDIFIED GASES

Design of Humidity Monitoring System Based on Virtual Instrument

GAS FREE REFRIGERATOR USING PELTIER MODULE

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Microspectrometers, which read color and the results

Photolithography SOPs

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

HOT BAR REFLOW SOLDERING FUNDAMENTALS by Amada Miyachi Europe A high quality Selective Soldering Technology

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Thin-film Micro-Heater for Fusion Bonding of Teflon-FEP Foils

VTT silicon photonics driving new business growth in Finland

Micromegas in a Bulk

EFFECTS OF AIR VELOCITY AND CLOTHING COMBINATION ON HEATING EFFICIENCY OF AN ELECTRICALLY HEATED VEST (EHV): A PILOT STUDY

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

ams Company overview Alexander Everke, CEO March 2018

To investigate the surface properties for increasing efficiency of solar water heater

Research Article Development of the Noncontact Temperature Sensor Using the Infrared Optical Fiber Coated with Antifog Solution

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Fabrication and characterisation of slim flat vacuum panels suitable for solar applications

Passive cooling of telecommunication outdoor cabinets for mobile base station

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Fabrication and Characterization of a Packaged MEMS Gas Flow Sensor

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

Testing a capacitive humidity sensor

(HR) Heating Resistors

Operating Instructions for the STS ICP Metal Etcher

Bourns Thick Film Resistive Heaters

CiS Institut für Mikrosensorik ggmbh. Haarbergstraße 61 D Erfurt

A study of Transient Performance of A Cascade Heat Pump System

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Process Technologies for High-Resolution Infrared Detectors based on LiTaO 3

Load-Carrying Capacity of Stone Column Encased with Geotextile. Anil Kumar Sahu 1 and Ishan Shankar 2

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Induction heating with the ring effect for injection molding plates

Technological advances within the field of micro multisensors: A Nordic perspective

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

2.2. General view of Microchannel Heat Exchangers

Operating Instructions for the SAMCO RIE800iPB

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

Experiment #6 Photolithography: Microprocessing Technology Fabrication of the microstructures with SPR photoresist

SAES Group March 26, making innovation happen, together

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

The effect of write current on thermal flying height control sliders with dual heater/insulator elements

Research on Evaluation of Fire Detection Algorithms

Transcription:

Proceedings Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor Yusuke Suganuma 1, Minoru Sasaki 2, Takahiro Nakayama 3, Masanori Muroyama 4 and Yutaka Nonomura 1, * 1 Meijo University, Nagoya, Japan; 173432011@ccalumni.meijo-u.ac.jp 2 Toyota Technological Institute, Nagoya, Japan; mnr-sasaki@toyota-ti.ac.jp 3 Toyota Motor Corporation, Nagoya, Japan; takahiro_nakayama_aa@mail.toyota.co.jp 4 Tohoku University, Sendai, Japan; muroyama@mems.mech.tohoku.ac.jp * Correspondence: nonomura@meijo-u.ac.jp Presented at the Eurosensors 2017 Conference, Paris, France, 3 6 September 2017. Published: 11 August 2017 Abstract: Tactile sensing is required for assistant robots. A new stacked sensor head was proposed which detects forces and thermal sensations with a nerve-net LSI chip. To measure temperatures and heat flows, the sensor head required a thin and small heater to heat up the sensor head. The features of the polyimide heater are compact, low heat capacity, low power consumption and ease of attaching it to the LSI chip. The polyimide heater consisted of Au 10 nm/cu 200 nm/cr 20 nm thickness layers on a polyimide film. The surface of the sensor head heated up to 60 C by the polyimide heater with 0.3 W. By the Cu thin film polyimide heater, the small stacked sensor head with the nerve-net LSI chip is enable to detect forces, temperatures, and heat flows, simultaneously. Keywords: tactile; sensor; robot; heater; polyimide; thin film; nerve-net 1. Introduction It is required for upcoming aging society to realize next generation robots such as assistant robots for housework, business work and nursing. The robots will coexist with parsons and assist them. Tactile sensors make the robots to detect contacts with parsons and things, and to grasp and hold them gently and safely. If tactile sensors detect human-like thermal sensing, they are useful for material estimation. The robots are enable to estimate materials of things, such as metals, glasses, clothes and human bodies by contact. And the robots will be able to feel health of patients. Beside an infrared thermo-camera, the tactile sensors detect temperatures of behind objects contiguously. The tactile sensors should cover whole the hands, arms and body of the robots for them to work well. A special nerve-net LSI chip has advantages in reducing number of wiring and simultaneous measurement with various sensors [1,2] (Figures 1 and 2). The LSI chip was packaged in ceramics for good thermal conductivity and durability (Figure 3). A stacked sensor head with the LSI chip shown in Figure 4 was proposed for detecting forces and thermal sensations. The sensor head was designed to be installed in fingertips of the robots and to detect forces, temperatures, and heat flows by fingertip contacts. For accurate heat flow measurement, a heat insulator covers the sensor head except a carbon sheet top. As the heat flow detection is required to estimate materials, a heater installed into the sensor head is required to make the heat flow. For the heater of the stacked sensor head, the followings are important. The heater is compact as small as 8.5 mm square, low heat capacity, low power consumption, and ease to mount it into the sensor head. Conventional product heaters were not suitable for the above requirements. Compared to silicon substrate, polyimide film is superior to thermal isolation, low heat capacity and flexibility. Therefore, the thin film heater on the polyimide Proceedings 2017, 1, 303; doi:10.3390/proceedings1040303 www.mdpi.com/journal/proceedings

Proceedings 2017, 1, 303 2 of 6 film is suitable for the sensor head. In the previous studies of polyimide heaters [3,4], gold and platinum films were used in practice. However, they were expensive and difficult to be products. We have designed and produced new heaters on a 125 μm thickness polyimide film. Cr and Cu films were compared as the heater material. The electric resistances and TCRs (resistance temperature coefficient) of the heaters were measured. Heating up the sensor head to 60 C and down to 20 C experiments were done with the heater. The heater materials and structures were evaluated to get the good thin film heater for the nerve-net tactile sensor [5,6]. Figure 1. Image of nerve-net tactile sensing in robot. Figure 2. Nerve-net tactile sensing systems. Figure 3. Nerve-net LSI chip packaged in ceramics.

Proceedings 2017, 1, 303 3 of 6 2. Design and Fabrication Figure 4. Structure of stacked sensor head. The small thin film heaters of Cr and Cu films were designed on the polyimide film for the sensor head. The required specifications of heaters are as follows. Area of the heater is smaller than the area of the LSI ceramic package Low power consumption to heat the sensor head surface up to 60 C Low heat capacity to get high thermal response of the sensor head Easy mounting on the surface of the LSI ceramic package The heaters were designed as 8.5 mm square. For low power consumption, low thermal capacity, and easy mounting, the polyimide film of 125 μm in thickness was selected as the heater substrate. The polyimide film is low thermal conductivity and flexible material. Cr and Cu films were compared as the heater material. The compositions of both film resistors are shown in Table 1. Line widths of heater patterns were changed from 400 μm to 800 μm. A fabrication process of the heater was as follows. Firstly, the polyimide film was glued on a silicon wafer with wax and photoresist was coated. Heater patterns of the photoresist on the polyimide film were made by photolithography with a glass mask. The glass mask of the heater is shown in Figure 5. Secondly, metal layers for the resistors and electrodes were formed by a vacuum evaporation as shown in Table 1 and Figure 6. Thirdly, after the heaters on the polyimide film were detached from the silicon wafer, a polyimide tape of 55 μm in thickness was pasted on the both surfaces of the heaters for protection. Table 1. Compositions of Cr and Cu film heaters. Style Cr film resistor Cu film resistor Common electrode Heater line width Composition of Film Au 10 nm/cr 300 nm/polyimide 125 μm Au 10 nm/cu 200 nm/cr 20 nm/polyimide 125 μm Au 10 nm/cu 200 nm/cr 20 nm 400 μm, 600 μm, 700 μm, 800 μm Figure 5. Glass mask of photolithography.

Proceedings 2017, 1, 303 4 of 6 3. Results Figure 6. Metal layers on polyimide film. 3.1. Thin Film Morphology and Electric Reistance Results A photograph of the heater with line width 400 μm is shown in Figure 7. Photomicrographs of the Cr and Cu film heater surfaces are shown in Figure 8. A lot of scratches and particle like dots were seen on the both surface films. Especially, the Cr film heater was damaged by scratches and particle like dots. The Cr film heaters had problems as electrical breaking of wire or very high resistance. The Cu film heaters worked well. Electric resistances of the Cu film heaters were presented in Table 2 in order of patterns as shown in Figure 5. The obtained electrical resistances of the Cu film heaters were about 7 times larger than calculated resistances which were estimated from a reported electrical resistivity of Cu bulk. By the four probes measurement, 90% of the total resistance of the heater was the resistance of the Cu thin film and 10% of the one was an interface resistance between the heater layer and electrode layers. Figure 7. Photograph of the polyimide heater. Figure 8. Photomicrographs of the Cr film heater (A) and the Cu film heater (B).

Proceedings 2017, 1, 303 5 of 6 Table 2. Resistance of the Cu film heater due to linewidth of heater pattern. Electric Resistance [Ω] 400 μm 800 μm 600 μm 700 μm Row 1 157 36 48 45 Row 2 136 34 44 42 Row 3 130 34 45 40 Row 4 128 33 43 39 Average Value 138 34 45 41 Calculated Value 18.4 5.1 6.7 5.8 Average/Calculated Ratio 749% 679% 673% 717% 3.2. Heater Performance Results The TCRs of the Cu film heater of line width 800 μm were measured and results were shown in Figure 9. Alumel-chromel thermocouples of 0.1 mm in diameter were used for temperature measurement of the heaters. It was found that the TCR of the heater was about 2.2 10 3 / C (<60 C) and almost no hysteresis property was obtained. The heater was attached to the LSI ceramics package and temperatures were measured with a setup as shown in Figure 10, while an experiment of heating up and down. The Cu film heater was successfully achieved a required target temperature of above 60 C at the sensor head surface with only 0.3 W as shown in Figure 11. Figure 9. TCR measurement of Cu film heater. Figure 10. Heating up and down experimental setup.

Proceedings 2017, 1, 303 6 of 6 4. Conclusions Figure 11. Heating up temperatures vs applied power. It was realized that the Cu thin film heater on the polyimide heated up the stacked sensor head successfully. The heater was fabricated with flexible in 8.5 mm square and about 0.2 mm thickness. The obtained electrical resistances of the heater were about 7 times larger than calculated resistances which were estimated from a reported electrical resistivity of Cu bulk. It was found that the TCR of the heater was about 2.2 10 3 / C (<60 C). The heater achieved target temperature 60 C at the sensor head surface with only 0.3 W, and obtained almost no hysteresis properties. The small sensor head with the nerve-net LSI chip is enable to detect forces, temperatures, and heat flows, simultaneously. The thin film heater and small temperature sensors will be combined to create ultra-small sensor head for robot fingers and artificial robot skin. Acknowledgments: A part of this work was supported by Toyota Technological Institute Nano Technology Hub in Nanotechnology Platform Project sponsored by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan. The present study is supported in part regarding the experiments of thermal sensing by the New Energy and Industrial Technology Development Organization (NEDO). The development of the sensor platform LSI and the integration technology was performed in R&D Center of Excellence for Integrated Microsystems, Tohoku University under the program Formation of Innovation Center for Fusion of Advanced Technologies supported by Special Coordination Funds for Promoting Science and Technology with collaboration with Toyota Motor Corporation and Toyota Central R&D Labs., Inc. Conflicts of Interest: The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results. References 1. Muroyama, M.; Makihata, M.; Nakano, Y.; Matsuzaki, S.; Yamada, H.; Yamaguchi, U.; Nakayama, T.; Nonomura, Y.; Fujiyoshi, M.; Tanaka, S.; et al. Development of an LSI for Tactile Sensor Systems on the Whole-Body of Robots. IEEJ Trans. Sens. Micromach. 2011, 131, 302 309. 2. Muroyama, M.; Nakayama, T.; Hata, Y.; Nonomura, Y.; Bartley, T.; Tanaka, S. A CMOS-LSI for a Sensor Network Platform of Social Robot Applications. In Proceedings of the Smart Systems Integration 2016, Munich, Germany, 9 10 March 2016; pp. 320 327. 3. Yu, S.; Wang, S.; Lu, M.; Zuo, L. A novel polyimide based micro heater with high temperature uniformity. Sens. Actuators A 2017, 257, 58 64. 4. Han, J.S.; Tan, Z.Y.; Sato, K.; Shikida, M. Thermal characterization of micro heater arrays on a polyimide film substrate for fingerprint sensing applications. J. Micromech. Microeng. 2004, 15, 282 289. 5. Yamadera, H.; Sugimoto, N.; Kageyama, Y. Preparation of MEMS Thin Film Heater by All Dry Processes and Application to GAS Sensor. IEEJ Trans. Sens. Micromach. 2011, 131, 246 250. 6. Kawato, Y.; Arimura, H.; Kudo, T. Sintering of Conductive Cu Nano Ink by Photo-sintering Process and Observation of Interface between Cu Film and PI. J. Smart Proc. 2013, 2, 173 177. 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).