AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Similar documents
WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh

MERIT SERIES Downflow

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

ELITE SERIES Downflow - High Efficiency Blower Motor

13 GEP A L P - 1 A

RGE 13 A T - 1 A

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

8+* Bulletin No November 1997

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

G34M Bulletin #69/ August 2003

High efficiency, cast-iron gas boiler

Product Data BW9 WATER BOILER SERIES B

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

MERIT SERIES Downflow

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

Replacement parts EG/PEG

Peerless Boilers. Series MI. Residential Gas Boilers

DIVISION FINNED WATER-TUBE BOILERS

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER. Models INSTALLATION, OPERATION & MAINTENANCE MANUAL

DIVISION FINNED WATER-TUBE BOILERS

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

CSD-1 COMMERCIAL BOILER CONTROLS

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

DIVISION FINNED WATER-TUBE BOILERS

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

Suggested Specifications Prestige Excellence 110

DXL SERIES II. Models CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER INSTALLATION, OPERATION & MAINTENANCE MANUAL

DIVISION FINNED WATER-TUBE WATER HEATERS

FSB Series Gas-Fired Hot Water

DIVISION FINNED WATER-TUBE WATER HEATERS

INSTALLATION INSTRUCTIONS PLYMOUTH XTREME GAS-FIRED HOT WATER BOILERS

Raypak Residential Products

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

INSTALLATION INSTRUCTIONS

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

U n i t H e at e r s

LGB Gas fired boiler

FINNED WATER-TUBE POOL HEATERS

INSTALLATION INSTRUCTIONS

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

GSR21Q PULSE21 SERIES

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

SECTION HEATING BOILERS

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

FINNED WATER-TUBE POOL HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

MERIT Series R-410A - Upflow / Horizontal

DIVISION FINNED WATER-TUBE BOILERS

Utica Boilers MAC Submittal

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

MERIT SERIES Upflow / Horizontal

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

RG7D 1-Stage Heat Series

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

WPSB SERIES II GAS-FIRED HOT WATER BOILERS

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

MERIT SERIES Downflow

WPSB SERIES II. Models WPSB-3D WPSB-3DP WPSB-4D WPSB-4DP WPSB-5D WPSB-5DP WPSB-6D WPSB-6DP WPSB-7D WPSB-7DP WPSB-8D WPSB-8DP WPSB-9D WPSB-9DP

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

ADF/ADFH 300 and 500

Transcription:

HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION Series GWB = Gas-Fired Hot Water Boiler AFUE Mininum Efficiency - 8 = 8% GWB 8-075 E - 3 Revision Number 3 = 3rd Generation Ignition E = Electronic Ignition Capacity (Input) 050 = 50,000 Btuh 075 = 75,000 Btuh 00 = 00,000 Btuh 5 = 5,000 Btuh 50 = 50,000 Btuh 70 = 70,000 Btuh 00 = 00,000 Btuh 6 = 6,000 Btuh 99 = 99,000 Btuh FEATURES CONTENTS Dimensions... 7 Features... High Altitude Derate... 6 Installation Clearances... 6 Model Number Identification... Specifications... 5 WARRANTY Cast iron boiler assembly - Limited twenty-year warranty in residential applications only. All other covered components - Limited five-year warranty in residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details.

FEATURES APPROVALS Low pressure, sectional cast iron boilers are design certified by CSA for use with natural gas or LPG/ Propane. Annual Fuel Utilization Efficiencies are based on US DOE test procedures and FTC labeling regulations. Units are certified by AHRI. Boiler heat exchanger assemblies are constructed and hydrostatically tested in accordance with American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section IV Standards for cast iron heating boilers.. APPLICATIONS Heating inputs of 50,000 to 99,000 Btuh. AFUE s of up to 83.9%. Natural gas or LPG/Propane (LPG with optional conversion kit). Boiler applications include radiant floor heating, baseboard heating and zoned heating systems. Compact size allows easy installation in a basement or utility room. All units are completely factory assembled with all controls installed and wired. Each unit is factory test operated to ensure dependable performance. HEATING SYSTEM Cast Iron Boiler Assembly Boiler sections and push nipples are constructed of long life cast iron. Boiler sections and push nipples expand and contract together, providing positive watertight seal. Boiler components are easily accessible for cleaning and servicing. Electronic Ignition Electronic spark igniter provides positive ignition of pilot burner on each operating cycle. Pilot gas is ignited and burns during each running cycle of the boiler. Main burners and pilot gas are extinguished during the off cycle. Ignition system permits main gas valve to open only when the pilot burner is proven to be lit. Should flame fail to ignite, control will continue to reattempt ignition. Pilot operation is fully automatic on demand for heat. Should a loss of flame occur, the main valve closes, shutting down the unit. Automatic Gas Control Silent operating gas controls provide 00% safety shut off. 4 volt redundant combination gas control valve combines automatic safety pilot, manual shut off option (On-Off), pilot filtration, automatic electric valve (dual) and gas pressure regulation into a compact combination control. Dual valve design provides double assurance of 00% close off of gas to the pilot and main burners on each off cycle. Stainless Steel Burners (050 to 00 Models) Each burner has rows of continuous ports which result in quiet and clean combustion. Titanium Burners (6 and 99 Models) Titanium composite burners resist corrosion and oxidation. Slotted port design results in quiet, clean combustion. Superior strength and longevity. Circulating Pump Heavy duty pump is constructed of cast iron. Pump motor is impedance protected. Motor and impeller is removeable as a single unit for servicing. Pump is shipped separately for field installation. Relief Valve Furnished as standard and factory installed on 50 to 00 models. Field installed on top of cabinet on 60 and 99 models. Valve provides for pressure relief of heating system in case of abnormal operating conditions. Valve opens at 30 psig and is approved by ASME. Combination Temperature/Pressure Gauge Gauge monitors system for safe and reliable operation. Brass Drain Valve 3/4 in. brass drain valve is furnished as standard and factory installed in drain outlet on side of cabinet on 50 to 00 models. Filed installed on 60 and 300 models. See dimension drawing for location. Optional Accessories LPG/Propane Conversion Kit Conversion kit required for field changeover from natural gas. Kits available for standard and high altitude operation. See Specifications tables. GWB8-E / Page

FEATURES IGNITION CONTROL MODULE Control module provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot spark ignition heating system. BOILER CONTROL MODULE On-board microprocessor saves fuel by adjusting boiler temperature based on heating demand. Easy dial-in settings for low/high temperature limits and economy settings. Installed external to the boiler cabinet in durable protective housing with display window. Thermal Targeting Microprocessor-based algorithm monitors thermostat activity and continually evaluates how much heat the house requires. When it is very cold outside, heat demand is high and the control raises the boiler Target Temperature to provide needed heat to the house. When the outside temperature is milder, heat demand is lower. During these periods, the control lowers the boiler Target Temperature - saving fuel - while continuing to provide comfort to the house. Thermal Pre-Purge Enhances boiler efficiency by supplying latent heat that may remain in the boiler from a previous run cycle to the heating zone requiring heat. The control activates the burner only when it determines that the latent heat will not be adequate to satisfy the heating demand. Enhanced Condensing Protection (Optional Setting) Allows the boiler to heat to 5 F before energizing the circulating pump, reducing the potential for condensing. Once activated, the control continues to monitor boiler temperature and interrupts the pump if it drops below 5 F. Display LEDs Three, seven segment LEDs continually displays boiler temperature. Instantly changes to display control settings when any dial is adjusted. Indicator light for heating call. Fahrenheit or Celsius display. LED Status Lights Status lights on top of control continually indicates which functions are active and if the control is holding the burner off for any reason. TEMP ACTIVE Indicates the control is powered and the temperature function is active. HI TEMP Illuminates any time the burner is off as a result of the boiler reaching the high limit setting. LWCO ACTIVE Illuminates when the control is providing low water cut-off protection. LOW Indicates a low water condition in the boiler. ECONOMY ACTIVE Indicates that the Economy dial is turned on and that Thermal Targeting function is active. TARGET Illuminates any time the burner is off as a result of the boiler reaching the Target temperature determined by Thermal Targeting. TEST SETTINGS BUTTON Automatic or Manual reset mode. and test settings for initial control setup. ADDITIONAL CONTROLS Flame Rollout Switch Temperature sensitive fusible-link device is furnished and factory installed on the boiler base just outside of the burner box. Prevents unit operation in the event combustion products passageway through the flueway is reduced or blocked. Junction Box Furnished in Control Module housing for easy field wiring. Limit Sensor Factory installed immersion type limit sensor provides protection against abnormal operating conditions. Transformer 40VA transformer furnished for control module operation. Optional Accessories Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. GWB8-E / Page 3

FEATURES VENTING Blocked Vent Shutoff Sensor Temperature Switch prevents unit operation in case of flue blockage. Sensor is furnished as standard and factory installed at the relief opening of the draft diverter. Integral Draft Hood Reduces the overall height and footprint of the boiler making it ideal for low clearance/space limited installations. Vent Damper Motorized vent damper electrically interlocks with the gas ignition system to increase efficiency of heating system by reducing loss of heated air up the chimney after burner shut off. Also reduces chimney infiltration during boiler off cycle. Furnished as standard for field installation. CABINET Constructed of heavy gauge steel with a baked-on enamel paint finish. Cabinet is fully insulated with fiberglass insulation, keeping cabinet surface temperatures low. Hole for drain valve (furnished) is furnished on left side of cabinet for 6 and 99 models only. Controls are shipped factory installed on right side of cabinet. Burner access panel is easily removed for servicing. Integral draft diverter is part of unit cabinet. GWB8-E / Page 4

SPECIFICATIONS Gas Heating Performance Model No. GWB8-050E-3 GWB8-075E-3 GWB8-00E-3 GWB8-5E-3 GWB8-50E-3 Heating capacity input - Btuh 50,000 75,000 00,000 5,000 50,000 Heating capacity output - Btuh 4,000 63,000 83,000 04,000 4,000 Net AHRI I=B=R rating - Btuh 37,000 55,000 7,000 90,000 08,000 AFUE 83.5% 83.% 83.0% 8.0% 83.0% Boiler Data Number of boiler sections 3 3 4 4 Connections in. Gas piping size I.P.S. Electrical characteristics Boiler capacity - U.S. gallons.4 4.0 4.0 5.6 5.6 Flue Size diameter (round) 4 5 6 6 7 Natural gas / NPT / NPT / NPT / NPT / NPT LPG/Propane / NPT / NPT / NPT / NPT / NPT Water supply and return size -/4 NPT -/4 NPT -/4 NPT -/4 NPT -/4 NPT Drain connection size 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 0 volts - 60 hertz - phase (less than amps) Shipping Data lbs. - package 05 53 53 35 35 OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories LPG/Propane Conversion Kit 68E0 76E0 68E0 7E0 68E0 Net AHRI water ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control. Ratings based on an allowance of.5 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute. Selection of boiler size should be based on Net I=B=R Rating being equal to or greater than the calculated heat loss of the building. Annual Fuel Utilization Efficiency based on US DOE test procedures and FTC labeling regulations. SPECIFICATIONS Gas Heating Performance Model No. GWB8-70E-3 GWB8-00E-3 GWB8-6E-3 GWB8-99E-3 Heating capacity input - Btuh 70,000 00,000 6,000 99,000 Heating capacity output - Btuh 39,000 65,000 0,000 5,000 Net I=B=R rating - Btuh,000 43,000 9,000 8,000 AFUE 8.0% 8.0% 83.9% 83.7% Boiler Data Number of boiler sections 5 5 8 9 Connections in. Boiler capacity - U.S. gallons 7. 7..7 4.4 Flue Size diameter (round) 7 8 7 7 Gas piping size I.P.S. Electrical characteristics Natural gas / NPT / NPT 3/4 NPT 3/4 NPT LPG/Propane / NPT / NPT / NPT / NPT Water supply and return size -/4 NPT -/4 NPT -/4 NPT -/4 NPT Drain connection size 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 0 volts - 60 hertz - phase (less than amps) Shipping Data lbs. - package 377 377 55 66 OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories LPG/Propane Conversion Kit 7E0 68E0 7E0 74E0 Net AHRI water ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control. Ratings based on an allowance of.5 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute. Selection of boiler size should be based on Net I=B=R Rating being equal to or greater than the calculated heat loss of the building. Annual Fuel Utilization Efficiency based on US DOE test procedures and FTC labeling regulations. GWB8-E / Page 5

HIGH ALTITUDE DERATE CSA certified units for the U.S. must be derated when installed at an elevation of more than 000 feet above sea level. If unit is installed at an altitude higher than 000 feet, the unit must be derated 4% for every 000 feet above sea level. Thus, at an altitude of 4000 feet, the unit would require a derate of 6%. CSA certified units for Canada must be derated when installed at an elevation of more than 000 feet above sea level. If unit is installed at an altitude higher than 000 feet, the unit must be derated 0% for elevations between 000 feet and 4500 feet above sea level. NOTE This is the only permissible derate for these units. INSTALLATION CLEARANCES - INCHES (MM) Size 050 to 00 Models 6 to 99 Models Left Side 3 (76) 6 (5) Right Side Gas Supply/Control Side 9 (9) 7 (78) Top 8 (457) 6 (5) Front Alcove Alcove Rear 4 (0 6 (5) Service Clearance (Front and Right Side) 4 (60) 4 (60) Floor Non-Combustible Non-Combustible Flue Pipe Vertical 6 (5) 6 (5) Horizontal 6 (5) 6 (5) Type B vent pipe (vertical venting only) (5) (5) Hot Water Piping (5) (5) NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ ANSI-Z3.) or the National Standard of Canada CAN/CSA-B49. Natural Gas and Propane Installation Code. NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z3.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B49.. Definition of Alcove is a three-sided space with no wall in front of boiler. ANSI standard for alcove is 8 inches (457 mm) from front of appliance to leading edge of side walls. Clearance for installation on combustible floor if combustible flooring base (field supplied) is installed between the boiler and the combustible floor. GWB8-E / Page 6

DIMENSIONS - INCHES (MM) - 050 TO 00 MODELS D VENT DAMPER (Furnished) C A 7 (686) 3-/ 5-/ (89) (40) BOILER SUPPLY CONTROL MODULE 3 (76) B 4 (356) BLOCKED VENT SENSOR ROLLOUT SWITCH RETURN 30-3/4 DRAIN (78) VALVE (Furnished) IGNITION CONTROL MODULE RELIEF VALVE TEMPERATURE/ PRESSURE GAUGE RETURN 4-/4 (08) GAS VALVE LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW NOTE - Pump is shipped separately with unit for field installation. Model No. A B C D in. mm in. mm in. mm in. mm GWB8-050E-3 -/8 83 36-/4 9 5-/ 40 5-3/4 46 GWB8-075E-3 5 38 37-3/4 959 7-/ 9 5-3/4 46 GWB8-00E-3 5 38 37-/4 946 7-/ 9 6 5 GWB8-5E-3 8-7/8 479 37-/4 946 9-/ 4 6 5 GWB8-50E-3 8-7/8 479 37-3/4 959 9-/ 4 6-3/4 7 GWB8-70E-3-3/4 578 38-3/4 984 -/ 9 6-3/4 7 GWB8-00E-3-3/4 578 38-3/4 984 -/ 9 7-3/4 97 NOTE - Add 6 (5 mm) to height for Vent Damper. DIMENSIONS - INCHES (MM) - 6 TO 99 MODELS 9 (737) RELIEF VALVE VENT DAMPER (Furnished) -/4 (3) DRAIN VALVE (Furnished) ROLLOUT SWITCH SUPPLY A 6-/ (673) BLOCKED VENT SENSOR TEMPERATURE/ PRESSURE GAUGE (Furnished, Field Installed) RETURN 5-3/8 (37) 36-3/8 (94) 4-3/4 () BOILER CONTROL MODULE IGNITION CONTROL MODULE GAS VALVE SUPPLY RETURN LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW NOTE - Pump is shipped separately with unit for field installation. Minimum acceptable height for low water cutoff probe. Model No. A in. mm GWB8-6E-3 7-/ 699 GWB8-99E-3 30-3/4 78 NOTE - Add 7 (78 mm) to height for Vent Damper. GWB8-E / Page 7

REVISIONS Section Features Description New Boiler Control Module. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 06 Lennox Industries, Inc.